TY - GEN A1 - Frauenrath, Tobias A1 - Fuchs, Katharina A1 - Hezel, Fabian A1 - Dieringer, Matthias A. A1 - Rieger, Jan A1 - Niendorf, Thoralf T1 - Improved cardiac triggering by combining multiple physiological signals: a cardiac MR feasibility study at 7.0 T T2 - 2012 ISMRM Annual Meeting Proceedings N2 - In current clinical cardiovascular MR (CMR) practice cardiac motion is commonly dealt with using ECG based synchronization. However, ECG is corrupted by magneto-hydrodynamic (MHD) effects in magnetic fields. This leads to artifacts in the ECG trace and evokes severe T-wave elevations, which might be misinterpreted as R-waves resulting in erroneous triggering. At (ultra)high field strengths, the propensity of ECG recordings to MHD effects is further pronounced. Pulse oximetry (POX) being inherently sensitive to blood oxygenation provides an alternative approach for cardiac gating. However, due to the travel time of the blood the peak of maximum oxygenation and hence the trigger is delayed by approx. 300 ms with respect to the ECG's R-wave. Also the peak of maximum oxygenation shows a jitter of up to 65 ms. Alternative triggering approaches include acoustic cardiac triggering (ACT). In current clinical practice cardiac gating / triggering commonly relies on using single physiological signals only. Realizing this limitation this study proposes a combined triggering approach which exploits multiple physiological signals including ECG, POX or ACT to track cardiac activity. The feasibility of the coupled approach is examined for LV function assessment at 7.0 T. For this purpose, breath-held 2D-CINE imaging in conjunction with cardiac synchronization was performed paralleled by real time logging of physiological waveforms to track (mis)synchronization between the cardiac cycle and data acquisition. Combinations of the ECG, POX and ACT signals were evaluated and processed in real time to facilitate reliable trigger information. Y1 - 2012 SN - 1545-4428 N1 - ISMRM 20th Annual Meeting & Exhibition, 5-11 May 2012, Melbourne, Australia ER - TY - PAT A1 - Frauenrath, Tobias A1 - Niendorf, Thoralf T1 - MRT-Vorrichtung und Verfahren zum Betreiben einer MRT-Vorrichtung T1 - Magnetic resonance tomography (MRT) apparatus and method of operating a magnetic resonance (MR) apparatus T1 - Appareil de tomographie par résonance magnétique et procédé de fonctionnement d'un appareil à résonance magnétique N2 - A magnetic resonance tomography (MRT) apparatus (1) for the examination of a body (14) comprises parameter acquisition devices (13) for the acquisition of cardiovascular parameters of the body (14) and a control device (15) in communication with the parameter acquisition devices (13) for synchronizing the imaging, wherein the control device (15) is adapted to analyse the data of at least two parameter acquisition devices (13) and to output a control signal based on the analysis. Y1 - 2012 ER - TY - GEN A1 - Frauenrath, Tobias A1 - Pfeiffer, Harald A1 - Hezel, Fabian A1 - Dieringer, Matthias A. A1 - Winter, Lukas A1 - Gräßl, Andreas A1 - Santoro, Davide A1 - Özerdem, Celal A1 - Renz, Wolfgang A1 - Greiser, Andreas A1 - Niendorf, Thoralf T1 - Lessons learned from cardiac MRI at 7.0 T: LV function assessment at 3.0 T using local multi-channel transceiver coil arrays T2 - 2012 ISMRM Annual Meeting Proceedings N2 - Cardiac MR (CMR) is of proven clinical value but also an area of vigorous ongoing research since image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Recent developments of CMR at 7.0 T have been driven by pioneering explorations into novel multichannel transmit and receive coil array technology to tackle the challenges B1+-field inhomogeneities, to offset specific-absorption rate (SAR) constraints and to reduce banding artifacts in SSFP imaging. For this study, recognition of the benefits and performance of local surface Tx/Rx-array structures recently established at 7.0 T inspired migration to 3.0 T, where RF inhomogeneities and SAR limitations encountered in routine clinical CMR, though somewhat reduced versus the 7.0 T situation, remain significant. For all these reasons, this study was designed to build and examine the feasibility of a local four channel Tx/Rx cardiac coil array for anatomical and functional cardiac imaging at 3.0 T. For comparison, a homebuilt 4 channel Rx cardiac coil array exhibiting the same geometry as the Tx/Rx coil and a Rx surface coil array were used. Y1 - 2012 SN - 1545-4428 N1 - ISMRM 20th Annual Meeting & Exhibition, 5-11 May 2012, Melbourne, Australia ER - TY - CHAP A1 - Fredebeul-Krein, Markus A1 - Steingröver, Markus T1 - Wholesale Broadband Access to IPTV in an NGA environment : how to deal with it from a regulatory perspective? Y1 - 2012 N1 - Regional ITS Conference of the international Telecommunications Society , February 22-24, 2012 New Delhi, India SP - 1 EP - 16 ER - TY - CHAP A1 - Fricke, Barbara A1 - Ziolko, C. A1 - Anthrakidis, Anette A1 - Alexopoulos, Spiros A1 - Hoffschmidt, Bernhard A1 - Giese, F. A1 - Dillig, M. T1 - InnoSol - environmental aspects of the open volumetric receiver technology T2 - 30th ISES Biennial Solar World Congress 2011 : : Kassel, Germany, 28 August - 2 September 2011. Vol. 5 Y1 - 2012 SP - 3895 EP - 3900 PB - Curran CY - Red Hook, NY ER - TY - JOUR A1 - Frings, Michael T1 - Immobilienfinanzierung und Verbraucherkredit : Das neue Verbraucherkreditrecht nach der Verbraucherkreditrichtlinie JF - NWB : Steuer- und Wirtschaftsrecht N2 - Mit Gesetz vom 29.7.2009 (BGBl 2009 I S. 2355) hat der deutsche Gesetzgeber die EU-Verbraucherkreditrichtlinie 2008/48/EG vom 23.4.2008 NWB PAAAD-28762 in nationales Recht umgesetzt. In diesem Gesetz ist auch der Immobiliardarlehensvertrag neu geregelt worden. Auf diese besondere Kreditform sind grds. die Vorschriften zum Verbraucherkredit anzuwenden, so dass der Darlehensgeber auch im Fall einer Immobilienfinanzierung zu vorvertraglicher Information des Verbrauchers verpflichtet ist. Beim finanzierten Immobilienerwerb werden Veräußerer und kreditgebende Bank häufig in Abstimmung und Zusammenarbeit tätig, so dass für die Bank besondere Aufklärungspflichten gegenüber dem Verbraucher entstehen. Im Fall der Verletzung dieser Pflichten drohen ihr Schadensersatzansprüche oder ein Widerrufsrecht des Verbrauchers. Y1 - 2012 SN - 0028-3460 VL - 2012 IS - 15 SP - 1237 EP - 1247 PB - NWB-Verlag CY - Herne ER - TY - JOUR A1 - Frings, Michael T1 - Verbesserter Schutz vor Kostenfallen im elektronischen Geschäftsverkehr („Buttonlösung”) : Erster Schritt zur Umsetzung der neuen EU-Verbraucherrechterichtlinie JF - NWB : NWB-Steuer- und Wirtschaftsrecht N2 - Der Deutsche Bundestag und Bundesrat haben am 2.3.2012 bzw. 30.3.2012 das Gesetz gegen Kostenfallen im Internet verabschiedet, das am 1.8.2012 in Kraft treten wird. Hiermit hat der deutsche Gesetzgeber einen ersten Schritt getan, um die neue EU-Verbraucherrechterichtlinie vom 25.10.2011 (2011/83/EU, ABl L 304/64) in nationales Recht umzusetzen. Mit dieser Umsetzung ist das drängendste Problem der Kosten- und Abo-Fallen im elektronischen Geschäftsverkehr aus dem Gesamtpaket der Verbraucherrechterichtlinie herausgelöst und in dem neugefassten § 312g BGB behandelt worden. Eile bei der Umsetzung war hier geboten, weil unseriöse Unternehmen im elektronischen Rechtsverkehr zunehmend und in großem Umfang gegenüber ihren Kunden durch irreführende Gestaltungen ihrer Internetseiten verschleiern, dass die angebotenen Leistungen entgeltpflichtig sind. Y1 - 2012 SN - 0028-3460 N1 - Fundstelle BAAAE-10367 VL - 2012 IS - 23 SP - 1912 EP - 1918 PB - NWB-Verlag CY - Herne ER - TY - CHAP A1 - Frotscher, Ralf A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred ED - Holzapfel, Gerhard A. T1 - Effectiveness of the edge-based smoothed finite element method applied to soft biological tissues T2 - ESMC-2012 - 8th European Solid Mechanics Conference, Graz, Austria, July 9-13, 2012 Y1 - 2012 SN - 978-3-85125-223-1 PB - Verlag d. Technischen Universität Graz CY - Graz ER - TY - CHAP A1 - Frotscher, Ralf A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred ED - Eberhardsteiner, J. T1 - Application of an edge-based smoothed finite element method on geometrically non-linear plates of non-linear material T2 - Proceedings European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Y1 - 2012 N1 - 6th European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Vienna, Austria, September 10-14, 2012 ER - TY - CHAP A1 - Frühwald, Katja A1 - Peterson, Leif Arne A1 - Hasenstab, Andreas ED - Fouad, Nabil A. T1 - Prüfverfahren zur Begutachtung der Materialeigenschaften von Holztragwerken T2 - Bauphysik‐Kalender 2012: Schwerpunkt: Gebäudediagnostik N2 - Dieses Kapitel beinhaltet: - Einleitung - Ausgewählte typische Schäden an Holzbauwerken - Das Material Holz und seine Besonderheiten - Bestandserfassung - Labormethoden - Begutachtungsbeispiele - Zusammenfassung und Schlussfolgerungen - Literatur Y1 - 2012 SN - 9783433029862 (Print) SN - 9783433601235 (Online) U6 - https://doi.org/10.1002/9783433601235.ch4 SP - 103 EP - 155 PB - Ernst & Sohn CY - Berlin ER - TY - CHAP A1 - Fuchs, Britta A1 - Ritz, Thomas A1 - Strauch, Jakob ED - Obaidat, Mohammad S. T1 - Usability of mobile applications : dissemination of usability engineering in small and medium enterprises T2 - Proceedings of the International Conference on Data Communication Networking, e-Business and Optical Communication Systems : Rome, Italy, 24 - 27 July, 2012 ; [integrated in the ICETE (International Conference on e-Business and Telecommunications)] Y1 - 2012 SN - 978-989-8565-23-5 N1 - Nebentitel: DCNET; ICE-B; OPTICS SP - 272 EP - 277 PB - SciTePress CY - [Lissabon] ER - TY - CHAP A1 - Funke, Harald A1 - Börner, Sebastian A1 - Keinz, Jan A1 - Hendrick, P. A1 - Recker, E. T1 - Low NOx Hydrogen combustion chamber for industrial gas turbine applications“, 14th International Symposium on Transport Phenomena and Dynamics of Rotating Machinery T2 - ISROMAC-14 : the Forteenth International Symposium on Transport Phenomena and Dynamics of Rotating Machinery ; Honolulu, Hawaii, February 27 - March 02nd, 2012 Y1 - 2012 N1 - International Symposium on Transport Phenomena and Dynamics of Rotating Machinery ; (14 ; 2012.02.27-03.02 ; Honolulu, Hawaii) ER - TY - CHAP A1 - Funke, Harald A1 - Börner, Sebastian A1 - Keinz, Jan A1 - Kusterer, K. A1 - Kroninger, D. A1 - Kitajima, J. A1 - Kazari, M. A1 - Horikama, A. T1 - Numerical and experimental characterization of low NOx Micromix combustion principle for industrial hydrogen gas turbine applications T2 - Proceedings of ASME Turbo Expo 2012 Y1 - 2013 N1 - ASME Turbo Expo 2012, GT2012, June 11-15, 2012, Copenhagen, Denmark ER - TY - CHAP A1 - Ganegedara, H. A1 - Alahakoon, D. A1 - Mashford, J. A1 - Paplinski, A. A1 - Müller, Karsten A1 - Deserno, T. M. T1 - Self organising map based region of interest labelling for automated defect identification in large sewer pipe image collections T2 - The 2012 International Joint Conference on Neural Networks (IJCNN) : 10 - 15 June 2012, Brisbane, Australia ; [part of the] 2012 IEEE World Congress on Computational Intelligence (IEEE-WCCI 2012) Y1 - 2012 SN - 978-1-4673-1490-9 PB - IEEE CY - Piscataway, NJ ER - TY - BOOK A1 - Gell, Sebastian T1 - Determinants of earnings forecast error, earnings forecast revision and earnings forecast accuracy N2 - ​Earnings forecasts are ubiquitous in today’s financial markets. They are essential indicators of future firm performance and a starting point for firm valuation. Extremely inaccurate and overoptimistic forecasts during the most recent financial crisis have raised serious doubts regarding the reliability of such forecasts. This thesis therefore investigates new determinants of forecast errors and accuracy. In addition, new determinants of forecast revisions are examined. More specifically, the thesis answers the following questions: 1) How do analyst incentives lead to forecast errors? 2) How do changes in analyst incentives lead to forecast revisions?, and 3) What factors drive differences in forecast accuracy? Y1 - 2012 SN - 978-3-8349-3936-4 SN - 978-3-8349-3937-1 U6 - https://doi.org/10.1007/978-3-8349-3937-1 N1 - Titel in der Buchreihe: Quantitatives Controlling PB - Springer Gabler CY - Wiesbaden ER - TY - CHAP A1 - Gerhards, Michael A1 - Sander, Volker A1 - Belloum, Adam ED - Zimmermann, Wolf ED - Lee, Yong Woo ED - Demchenko, Yuri T1 - About the flexible Migration of Workflow Tasks to Clouds : Combining on- and off-premise Executions of Applications T2 - CLOUD COMPUTING 2012 : The Third International Conference on Cloud Computing, GRIDs, and Virtualization ; July 22-27, 2012 - Nice, France N2 - An increasing number of applications target their executions on specific hardware like general purpose Graphics Processing Units. Some Cloud Computing providers offer this specific hardware so that organizations can rent such resources. However, outsourcing the whole application to the Cloud causes avoidable costs if only some parts of the application benefit from the specific expensive hardware. A partial execution of applications in the Cloud is a tradeoff between costs and efficiency. This paper addresses the demand for a consistent framework that allows for a mixture of on- and off-premise calculations by migrating only specific parts to a Cloud. It uses the concept of workflows to present how individual workflow tasks can be migrated to the Cloud whereas the remaining tasks are executed on-premise. KW - Workflow Orchestration KW - Workflow KW - Grid Computing KW - Cloud Service Broker KW - Cloud Computing Y1 - 2012 SN - 978-1-61208-216-5 SP - 82 EP - 87 PB - IARIA Journals ER - TY - CHAP A1 - Goldbach, Daniel T1 - Zuverlässigkeitsanalyse zur Verifikation der Einhaltung von quantitativen Sicherheitsanforderungen. T2 - Diagnose in mechatronischen Fahrzeugsystemen V : neue Verfahren für Test, Prüfung und Diagnose von E/E-Systemen im Kfz ; [anlässlich der 6. Tagung "Diagnose in Mechatronischen Fahrzeugsystemen" in Dresden]. Bernard Bäker ... (Hrsg.) Y1 - 2012 SN - 978-3-8169-3149-2 SP - 116 EP - 132 PB - Expert Verlag CY - Renningen ER - TY - PAT A1 - Gollewski, Torsten A1 - Lange, Robert A1 - Ringbeck, Thorsten A1 - Hess, Holger A1 - Buxbaum, Bernd T1 - Verfahren und Vorrichtung zur Laufzeitsensitiven Messung eines Signals [Offenlegungsschrift / Europäische Patentschrift] T1 - Apparatus for delay-sensitive measurement of a signal T1 - Dispositif pour le mesurage sensitif au temps de transit d'un signal Y1 - 2006 PB - Deutsches Patent- und Markenamt / Europäisches Patentamt CY - München / Den Hague ER - TY - JOUR A1 - Grande, Marion A1 - Meffert, Elisabeth A1 - Schoenberger, Eva A1 - Jung, Stefanie A1 - Frauenrath, Tobias A1 - Huber, Walter A1 - Hussmann, Katja A1 - Moormann, Mareike A1 - Heim, Stefan T1 - From a concept to a word in a syntactically complete sentence: An fMRI study on spontaneous language production in an overt picture description task JF - NeuroImage N2 - Spontaneous language has rarely been subjected to neuroimaging studies. This study therefore introduces a newly developed method for the analysis of linguistic phenomena observed in continuous language production during fMRI. Most neuroimaging studies investigating language have so far focussed on single word or — to a smaller extent — sentence processing, mostly due to methodological considerations. Natural language production, however, is far more than the mere combination of words to larger units. Therefore, the present study aimed at relating brain activation to linguistic phenomena like word-finding difficulties or syntactic completeness in a continuous language fMRI paradigm. A picture description task with special constraints was used to provoke hesitation phenomena and speech errors. The transcribed speech sample was segmented into events of one second and each event was assigned to one category of a complex schema especially developed for this purpose. The main results were: conceptual planning engages bilateral activation of the precuneus. Successful lexical retrieval is accompanied – particularly in comparison to unsolved word-finding difficulties – by the left middle and superior temporal gyrus. Syntactic completeness is reflected in activation of the left inferior frontal gyrus (IFG) (area 44). In sum, the method has proven to be useful for investigating the neural correlates of lexical and syntactic phenomena in an overt picture description task. This opens up new prospects for the analysis of spontaneous language production during fMRI. Y1 - 2012 U6 - https://doi.org/10.1016/j.neuroimage.2012.03.087 SN - 1522-2586 VL - 61 IS - 3 SP - 702 EP - 714 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Grinsven, Bart van A1 - Bon, Natalie vanden A1 - Strauven, Hannelore A1 - Grieten, Lars A1 - Murib, Mohammed A1 - Jiménez Monroy, Kathia L. A1 - Janssens, Stoffel D. A1 - Haenen, Ken A1 - Schöning, Michael Josef A1 - Vermeeren, Veronique A1 - Ameloot, Marcel A1 - Michiels, Luc A1 - Thoelen, Ronald A1 - Ceuninck, Ward de A1 - Wagner, Patrick T1 - Heat-Transfer Resistance at Solid-Liquid Interfaces: A Tool for The Detection of Single Nucleotide Polymorphisms in DNA. JF - ACS Nano N2 - In this article, we report on the heat-transfer resistance at interfaces as a novel, denaturation-based method to detect single-nucleotide polymorphisms in DNA. We observed that a molecular brush of double-stranded DNA grafted onto synthetic diamond surfaces does not notably affect the heat-transfer resistance at the solid-to-liquid interface. In contrast to this, molecular brushes of single-stranded DNA cause, surprisingly, a substantially higher heat-transfer resistance and behave like a thermally insulating layer. This effect can be utilized to identify ds-DNA melting temperatures via the switching from low- to high heat-transfer resistance. The melting temperatures identified with this method for different DNA duplexes (29 base pairs without and with built-in mutations) correlate nicely with data calculated by modeling. The method is fast, label-free (without the need for fluorescent or radioactive markers), allows for repetitive measurements, and can also be extended toward array formats. Reference measurements by confocal fluorescence microscopy and impedance spectroscopy confirm that the switching of heat-transfer resistance upon denaturation is indeed related to the thermal on-chip denaturation of DNA. Y1 - 2012 U6 - https://doi.org/10.1021/nn300147e SN - 1936-086X VL - 6 IS - 3 SP - 2712 EP - 2721 PB - ACS Publications CY - Washington, DC ER - TY - BOOK A1 - Grotendorst, Johannes T1 - Hierarchical methods for dynamics in complex molecular systems : IAS Winter School, 5 - 9 March 2012, Forschungszentrum Jülich GmbH ; lecture notes / ed. by Johannes Grotendorst, Godehard Sutmann, Gerhard Gompper, Dominik Marx Y1 - 2012 SN - 978-3-89336-768-9 N1 - (Schriften des Forschungszentrums Jülich IAS Series 10) PB - Forschungszentrum Jülich CY - Jülich ER - TY - JOUR A1 - Grotendorst, Johannes T1 - Supercomputer programmieren - ein besonderes Studienangebot in Jülich JF - Junge Wissenschaft. 27 (2012), H. 94 Y1 - 2012 SN - 0179-8529 SP - 12 EP - 14 PB - - ER - TY - JOUR A1 - Grotendorst, Johannes T1 - IAS Winter School: Hierarchical Methods for Dynamics in Complex Molecular Systems JF - Innovatives Supercomputing in Deutschland : inSiDE. 10 (2012), H. 1 Y1 - 2012 SP - 104 PB - - ER - TY - GEN A1 - Gräßl, Andreas A1 - Renz, Wolfgang A1 - Hezel, Fabian A1 - Frauenrath, Tobias A1 - Pfeiffer, Harald A1 - Hoffmann, Werner A1 - Kellmann, Peter A1 - Martin, Conrad A1 - Niendorf, Thoralf T1 - Design, evaluation and application of a modular 32 channel transmit/receive surface coil array for cardiac MRI at 7T T2 - 2012 ISMRM Annual Meeting Proceedings N2 - Cardiac MR (CMR) at ultrahigh (≥7.0 T) fields is regarded as one of the most challenging MRI applications. At 7.0 T image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Detrimental effects bear the potential to spoil the signal-to-noise (SNR) and contrast-to-noise (CNR) benefits of cardiac MR (CMR) at 7.0 T. B₁⁺-inhomogeneities and signal voids represent the main challenges. Various pioneering coil concepts have been proposed to tackle these issues, enabling cardiac MRI at 7.0 T. This includes a trend towards an ever larger number of transmit and receive channels. This approach affords multi-dimensional B₁⁺ modulations to improve B₁⁺ shimming performance and to enhance RF efficiency. Also, parallel imaging benefits from a high number of receive channels enabling two-dimensional acceleration. Realizing the limitations of existing coil designs tailored for UHF CMR and recognizing the opportunities of a many element TX/RX channel architecture this work proposes a modular, two dimensional 32-channel transmit and receive array using loop elements and examines its efficacy for enhanced B¹+ homogeneity and improved parallel imaging performance. Y1 - 2012 SN - 1545-4428 N1 - ISMRM 20th Annual Meeting & Exhibition, 5-11 May 2012, Melbourne, Australia ER - TY - JOUR A1 - Gutheil, Inge A1 - Berg, Tommy A1 - Grotendorst, Johannes T1 - Performance Analysis of Parallel Eigensolvers of two Libraries on BlueGene/P JF - Journal of Mathematics and Systems Science N2 - Many applications in computational science and engineering require the computation of eigenvalues and vectors of dense symmetric or Hermitian matrices. For example, in DFT (density functional theory) calculations on modern supercomputers 10% to 30% of the eigenvalues and eigenvectors of huge dense matrices have to be calculated. Therefore, performance and parallel scaling of the used eigensolvers is of upmost interest. In this article different routines of the linear algebra packages ScaLAPACK and Elemental for parallel solution of the symmetric eigenvalue problem are compared concerning their performance on the BlueGene/P supercomputer. Parameters for performance optimization are adjusted for the different data distribution methods used in the two libraries. It is found that for all test cases the new library Elemental which uses a two-dimensional element by element distribution of the matrices to the processors shows better performance than the old ScaLAPACK library which uses a block-cyclic distribution. KW - performance analysis KW - Elemental KW - ScaLAPACK KW - eigensolvers KW - Numerical linear algebra Y1 - 2012 U6 - https://doi.org/10.17265/2159-5291/2012.04.003 SN - 2159-5291 VL - 2 IS - 4 SP - 231 EP - 236 PB - David Publishing CY - Libertyville ER - TY - CHAP A1 - Hartmann, Axel A1 - Kallweit, Stephan A1 - Feldusen, Antje A1 - Schröder, Wolfgang T1 - Detection of upstream propagating sound waves at buffet flow using high-speed PIV BT - 16th International Symposium on Applications of Laser Techniques to Fluid Mechanics ; 9th to 12th July 2012 Lisbon, Portugal Y1 - 2012 N1 - Aerodynamisches Institut ; International Symposium on Applications of Laser Techniques to Fluid Mechanics <16, 2012, Lissabon> ER - TY - JOUR A1 - Hasan, Istabrak A1 - Keil, Ludger A1 - Staat, Manfred A1 - Wahl, Gerhard A1 - Bourauel, Christoph T1 - Determination of the frictional coefficient of the implant-antler interface : experimental approach JF - Biomedical Engineering / Biomedizinische Technik N2 - The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5–0.7 and 0.3–0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens. Y1 - 2012 SN - 1862-278X VL - 57 IS - 5 SP - 359 EP - 363 PB - De Gruyter CY - Berlin ER - TY - BOOK A1 - Hayn, Sven A1 - Waldersee, Georg Graf A1 - Benzel, Ute A1 - Utzerath, Meike T1 - HGB und Steuerbilanz im Vergleich: synoptische Darstellung von Handels- und Steuerbilanzrecht / Sven Hayn, Georg Graf Waldersee, Ute Benzel unter Mitarb. von Meike Utzerath ... Y1 - 2012 SN - 978-3-7910-3222-1 N1 - 1. Aufl. u.d.T.:Hayn, Sven: HGB, HGB-BilMoG, Steuerbilanz im Vergleich PB - Schäffer-Poeschel CY - Stuttgart ET - 2., überarb. Aufl. ER - TY - THES A1 - Hellmanns, Mark T1 - Qualitätssicherung von handgeführten Applikationsprozessen durch Nachverfolgung der Handhabungseinheit. (Fortschrittsberichte aus der Produktionstechnik ; 1) Y1 - 2012 SN - 978-3-8440-1379-5 N1 - Zugl.: Kassel, Univ., Diss., 2012 PB - Aachen CY - Shaker ER - TY - CHAP A1 - Helsper, Christoph A1 - Dressler, Jörg ED - Gail, Lothar ED - Gommel, Udo ED - Hortig, Hans-Peter T1 - Partikelmesstechnik T2 - Reinraumtechnik N2 - Der Schutz von Produkten vor der Kontamination durch Partikel gilt als eine zentrale Aufgabe der Reinraumtechnik. Da es dabei um Kontaminationseffekte weit unterhalb der visuellen Wahrnehmbarkeit geht, braucht es leistungsfähige Verfahren, um die Messgröße „Partikelkontamination“ über den gesamten Bereich, den Anwender fordern, präzise zu bestimmen. Neben der Partikelhäufigkeit ist dabei die Größe der Partikel, die sowohl das Transportverhalten wie auch die mögliche Wirkung auf das Produkt beeinflusst, von entscheidender Bedeutung. Ferner kann es für die Ermittlung von Kontaminationsquellen von Interesse sein, die Form und die chemische Natur der Partikel zu bestimmen (z. B. textile Fasern, Metallabrieb, flüssige Tröpfchen). Die Partikelhäufigkeit wird üblicherweise als Konzentration, d. h. bezogen auf das analysierte Gasvolumen angegeben. Bei den in reinen Technologien üblichen niedrigen Konzentrationen dient als Häufigkeitsmaß die Partikelanzahlkonzentration, also die Partikelanzahl pro Volumeneinheit des Trägermediums. Y1 - 2012 SN - 978-3-642-19435-1 U6 - https://doi.org/10.1007/978-3-642-19435-1_3 VL - 2012 SP - 69 EP - 95 PB - Springer CY - Berlin ET - 3 ER - TY - JOUR A1 - Henken, F. E. A1 - Oosterhuis, K. A1 - Öhlschläger, Peter A1 - Bosch, L. A1 - Hooijberg, E. A1 - Haanen, J. B. A. G. A1 - Steenbergen, R. D. M. T1 - Preclinical safety evaluation of DNA vaccines encoding modified HPV16 E6 and E7 JF - Vaccine N2 - Persistent infection with high-risk human papillomaviruses (hrHPV) can result in the formation of anogenital cancers. As hrHPV proteins E6 and E7 are required for cancer initiation and maintenance, they are ideal targets for immunotherapeutic interventions. Previously, we have described the development of DNA vaccines for the induction of HPV16 E6 and E7 specific T cell immunity. These vaccines consist of ‘gene-shuffled’ (SH) versions of HPV16 E6 and E7 that were fused to Tetanus Toxin Fragment C domain 1 (TTFC) and were named TTFC-E6SH and TTFC-E7SH. Gene-shuffling was performed to avoid the risk of inducing malignant transformation at the vaccination site. Here, we describe the preclinical safety evaluation of these candidate vaccines by analysis of their transforming capacity in vitro using established murine fibroblasts (NIH 3T3 cells) and primary human foreskin keratinocytes (HFKs). We demonstrate that neither ectopic expression of TTFC-E6SH and TTFC-E7SH alone or in combination enabled NIH 3T3 cells to form colonies in soft agar. In contrast, expression of HPV16 E6WT and E7WT alone or in combination resulted in effective transformation. Similarly, retroviral transduction of HFKs from three independent donors with both TTFC-E6SH and TTFC-E7SH alone or in combination did not show any signs of immortalization. In contrast, the combined expression of E6WT and E7WT induced immortalization in HFKs from all donors. Based on these results we consider it justified to proceed to clinical evaluation of DNA vaccines encoding TTFC-E6SH and TTFC-E7SH in patients with HPV16 associated (pre)malignancies. Y1 - 2012 U6 - https://doi.org/10.1016/j.vaccine.2012.04.013 SN - 0264-410X VL - 30 IS - 28 SP - 4259 EP - 4266 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Herzwurm, Georg A1 - Krams, Benedikt A1 - Pietsch, Wolfram A1 - Schockert, Sixten T1 - Report from the 3rd international workshop on requirements prioritization for customer oriented software development (RePriCo’12) JF - ACM SIGSOFT Software Engineering Notes N2 - Prioritization is an essential task within requirements engineering to cope with complexity and to establish focus properly. The 3rd Workshop on Requirements Prioritization for customer oriented Software Development (RePriCo’12) focused on requirements prioritization and adjacent themes in the context of customer oriented development of bespoke and standard software. Five submissions have been accepted for the proceedings and for presentation. The report summarizes and points out key findings. KW - Requirements relations KW - Discourse ethics KW - Tool support KW - Consensus KW - Requirements prioritization Y1 - 2012 U6 - https://doi.org/10.1145/2237796.2237817 SN - 0163-5948 VL - 37 IS - 4 SP - 32 EP - 34 PB - Association for Computing Machinery CY - New York ER - TY - BOOK A1 - Hoepner, Gert A1 - Schminke, Lutz H. T1 - Dialog-Marketing und E-Commerce : ein anwendungsorientiertes und konzeptionelles Kompendium für Praxis und Ausbildung Y1 - 2012 SN - 978-3-942171-23-6 PB - Uni-ed. GmbH CY - Berlin ER - TY - CHAP A1 - Hoffschmidt, Bernhard A1 - Alexopoulos, Spiros T1 - Perspektiven für Solarthermische Kraftwerke im Sonnengürtel T2 - Energiewende : Aspekte, Optionen, Herausforderungen : Vorträge auf der DPG-Frühjahrstagung Arbeitskreis Energie in der Deutschen Physikalischen Gesellschaft Berlin, 26. bis 28. März 2012 / hrsg. von Hardo Bruhns Y1 - 2012 SP - 81 EP - 93 PB - DPG CY - Baf Honnef ER - TY - CHAP A1 - Hoffschmidt, Bernhard A1 - Alexopoulos, Spiros A1 - Göttsche, Joachim A1 - Sauerborn, Markus T1 - High concentration solar collectors T2 - Comprehensive renewable energy / ed. Ali Sayigh. Vol. 3: Solar thermal systems: components and applications N2 - Solar thermal concentrated power is an emerging technology that provides clean electricity for the growing energy market. To the solar thermal concentrated power plant systems belong the parabolic trough, the Fresnel collector, the solar dish, and the central receiver system. For high-concentration solar collector systems, optical and thermal analysis is essential. There exist a number of measurement techniques and systems for the optical and thermal characterization of the efficiency of solar thermal concentrated systems. For each system, structure, components, and specific characteristics types are described. The chapter presents additionally an outline for the calculation of system performance and operation and maintenance topics. One main focus is set to the models of components and their construction details as well as different types on the market. In the later part of this chapter, different criteria for the choice of technology are analyzed in detail. KW - Central receiver system KW - Concentrated solar collector KW - Fresnel collector KW - Optical and thermal analysis KW - Solar concentration Y1 - 2012 SN - 978-0-08-087873-7 U6 - https://doi.org/10.1016/B978-0-08-087872-0.00306-1 VL - 3 SP - 165 EP - 209 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Hoffschmidt, Bernhard A1 - Alexopoulos, Spiros A1 - Rau, Christoph A1 - Sattler, Johannes Christoph A1 - Anthrakidis, Anette A1 - Teixeira Boura, Cristiano José A1 - O'Connor, P. A1 - Hilger, Patrick T1 - Concentrating solar power T2 - Comprehensive renewable energy / ed. Ali Sayigh. Vol. 3: Solar thermal systems: components and applications Y1 - 2012 SN - 978-0-08-087872-0 U6 - https://doi.org/10.1016/B978-0-08-087872-0.00319-X VL - 3 SP - 595 EP - 636 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Combined amperometric/field-effect sensor for the detection of dissolved hydrogen JF - Sensors and actuators B: Chemical N2 - Real-time and reliable monitoring of the biogas process is crucial for a stable and efficient operation of biogas production in order to avoid digester breakdowns. The concentration of dissolved hydrogen (H₂) represents one of the key parameters for biogas process control. In this work, a one-chip integrated combined amperometric/field-effect sensor for monitoring the dissolved H₂ concentration has been developed for biogas applications. The combination of two different transducer principles might allow a more accurate and reliable measurement of dissolved H₂ as an early warning indicator of digester failures. The feasibility of the approach has been demonstrated by simultaneous amperometric/field-effect measurements of dissolved H₂ concentrations in electrolyte solutions. Both, the amperometric and the field-effect transducer show a linear response behaviour in the H₂ concentration range from 0.1 to 3% (v/v) with a slope of 198.4 ± 13.7 nA/% (v/v) and 14.9 ± 0.5 mV/% (v/v), respectively. Y1 - 2012 U6 - https://doi.org/10.1016/j.snb.2012.10.050 SN - 0925-4005 N1 - Part of special issue "Selected Papers from the 14th International Meeting on Chemical Sensors" VL - 187 SP - 168 EP - 173 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hötter, Jan-Steffen A1 - Fateri, Miranda A1 - Gebhardt, Andreas T1 - Prozessoptimierung des SLM-Prozesses mit hoch-reflektiven und thermisch sehr gut leitenden Materialien durch systematische Parameterfindung und begleitende Simulationen am Beispiel von Silber JF - RTejournal - Forum für Rapid Technologie N2 - Additive Manufacturing durch Aufschmelzen von Metallpulvern hat sich auf breiter Front als Herstellverfahren, auch für Endprodukte, etabliert. Besonders für die Variante des Selective Laser Melting (SLM) sind Anwendungen in der Zahntechnik bereits weit verbreitet und der Einsatz in sensitiven Branchen wie der Luftfahrt ist in greifbare Nähe gerückt. Deshalb werden auch vermehrt Anstrengungen unternommen, um bisher nicht verarbeitete Materialien zu qualifizieren. Dies sind vorzugsweise Nicht-Eisen- und Edelmetalle, die sowohl eine sehr hohe Reflektivität als auch eine sehr gute Wärmeleitfähigkeit aufweisen – beides Eigenschaften, die die Beherrschung des Laser-Schmelzprozesses erschweren und nur kleine Prozessfenster zulassen. Die Arbeitsgruppe SLM des Lehr- und Forschungsgebietes Hochleistungsverfahren der Fertigungstechnik hat sich unter der Randbedingung einer kleinen und mit geringer Laserleistung ausgestatteten SLM Maschine der Aufgabe gewidmet und am Beispiel von Silber die Parameterfelder für Einzelspuren und wenig komplexe Geometrien systematisch untersucht. Die Arbeiten wurden von FEM Simulationen begleitet und durch metallographische Untersuchungen verifiziert. Die Ergebnisse bilden die Grundlage zur schnellen Parameterfindung bei komplexen Geometrien und bei Veränderungen der Zusammensetzung, wie sie bei zukünftigen Legierungen zu erwarten sind. Die Ergebnisse werden exemplarisch auf unterschiedliche Geometrien angewandt und entsprechende Bauteile gezeigt. N2 - Additive manufacturing by melting of metal powders is a method that has been established even for the manufacturing of final products. In particular, Selective Laser Melting (SLM) is currently applied for prosthetic dentistry. In the near future, this technology will access sensitive industries like aerospace engineering. This leads to the need to process new materials. Therefore, especially non-ferrous metals and noble metals must be determined and qualified. These materials have in common a very high reflectivity and an excellent thermal conductivity. In general, these two properties counteract the control of the melt pool and contribute to very narrow process windows. The “SLM” research team of the Aachen University of Applied Science, AcUAS (FH Aachen) systematically investigated process parameter fields for silver. The work focused on a small SLM desktop machine with comparably low laser power. The results are verified using FEA and metallographic inspections and will support future set-ups for complex geometries. Furthermore, the obtained parameter fields are applied to make different geometric objects and to manufactured parts, which are presented. KW - SLM KW - Selektives Laser Schmelzen KW - Silber Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0009-2-33639 SN - 1614-0923 VL - 9 IS - 1 SP - 1 EP - 14 PB - Fachhoschule Aachen CY - Aachen ER - TY - JOUR A1 - Hötter, Jan-Steffen A1 - Fateri, Miranda A1 - Gebhardt, Andreas T1 - Selective laser melting of metals: desktop machines open up new chances even for small companies JF - Advanced materials research N2 - Additive manufacturing (AM) of metal parts by using Selective Laser Melting (SLM) has become a powerful tool mostly in the area of automotive, aerospace engineering and others. Especially in the field of dentistry, jewelry and related branches that require individualized or even one-of-a-kind products, the direct digital manufacturing process opens up new ways of design and manufacturing. In these fields, mostly small and medium sized businesses (SME) are operating which do not have sufficient human and economic resources to invest in this technology. But to stay competitive, the application of AM can be regarded as a necessity. In this situation a new desktop machine (Realizer SLM 50) was introduced that cost about 1/3 of a shop floor SLM machine and promises small quality parts. To find out whether the machine really is an alternative for SMEs the University of Applied Science, Aachen, Germany, designed, build and optimized typical parts from the dentistry and the jewelry branches using CoCr and silver material, the latter being new with this application. The paper describes the SLM procedure and how to find and optimize the most important parameters. The test is accompanied by digital simulation in order to verify the build parameters and to plan future builds. The procedure is shown as well as the resulting parts made from CoCr and silver material. Y1 - 2012 U6 - https://doi.org/10.4028/www.scientific.net/AMR.622-623.461 SN - 1662-8985 (E-Journal); 1022-6680 (Print) VL - 622-623 SP - 461 EP - 465 PB - Trans Tech Publ. CY - Baech ER - TY - CHAP A1 - Hüning, Felix ED - Schmitz, Günter T1 - PowerMOSFETs für Elektromotoren im Automobil : Vom Fensterheber zum EPS T2 - Elektronik im Kraftfahrzeug : Innovationen bei Systemen und Komponenten ; mit 7 Tabellen Y1 - 2012 SN - 978-3-8169-3110-2 N1 - Haus der Technik Fachbuchreihe ; 123 SP - 71 EP - 81 PB - Expert Verlag CY - Renningen ER - TY - JOUR A1 - Hüning, Felix T1 - Using Trench PowerMOSFETs in Linear Mode JF - Power Electronics Europe (2012) N2 - If we think about applications for modern Power MOSFETs using trench technology, running them in linear mode may not be top of the priority list. Yet there are multiple uses for Trench Power MOSFETs in linear mode. In fact, even turning the device on and off in switching applications is a form of linear operation. Also, these components can be run in linear mode to protect the device against voltage surges. This article will illustrate the factors that need to be considered for linear operation and show how Trench Power MOSFETs are suited to it. Y1 - 2012 SN - 1748-3530 SP - 27 EP - 29 PB - DFA Media CY - Tonbridge ER - TY - JOUR A1 - Iken, Heiko A1 - Kirsanov, D. A1 - Legin, A. A1 - Schöning, Michael Josef T1 - Novel Thin-Film Polymeric Materials for the Detection of Heavy Metals JF - Procedia Engineering N2 - A variety of transition metals, e.g., copper, zinc, cadmium, lead, etc. are widely used in industry as components for wires, coatings, alloys, batteries, paints and so on. The inevitable presence of transition metals in industrial processes implies the ambition of developing a proper analytical technique for their adequate monitoring. Most of these elements, especially lead and cadmium, are acutely toxic for biological organisms. Quantitative determination of these metals at low activity levels in different environmental and industrial samples is therefore a vital task. A promising approach to achieve an at-side or on-line monitoring on a miniaturized and cost efficient way is the combination of a common potentiometric sensor array with heavy metal-sensitive thin-film materials, like chalcogenide glasses and polymeric materials, respectively. Y1 - 2012 U6 - https://doi.org/10.1016/j.proeng.2012.09.148 SN - 1877-7058 N1 - Part of special issue "26th European Conference on Solid-State Transducers, EUROSENSOR 2012" IS - 47 SP - 322 EP - 325 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Immel, Timo A1 - Grützke, Martin A1 - Späte, Anne-Katrin A1 - Groth, Ulrich A1 - Öhlschläger, Peter A1 - Huhn, Thomas T1 - Synthesis and X-ray structure analysis of a heptacoordinate titanium(IV)-bis-chelate with enhanced in vivo antitumor efficacy JF - Chemical Communications N2 - Chelate stabilization of a titanium(IV)–salan alkoxide by ligand exchange with 2,6-pyridinedicarboxylic acid (dipic) resulted in heptacoordinate complex 3 which is not redox-active, stable on silica gel and has increased aqueous stability. 3 is highly toxic in HeLa S3 and Hep G2 and has enhanced antitumor efficacy in a mouse cervical-cancer model. Y1 - 2012 U6 - https://doi.org/10.1039/C2CC31624B SN - 1364-548X VL - 48 IS - 46 SP - 5790 EP - 5792 PB - Royal Society of Chemistry CY - Cambridge ER - TY - CHAP A1 - Jakobs, Helmut T1 - Vorwort T2 - Vielen Dank für Ihren Einkauf : Konsumkultur aus Sicht von Design, Kunst und Medien Y1 - 2012 SN - 978-3-8376-2170-9 SP - 7 PB - Transcript Verlag CY - Bielefeld ER - TY - BOOK A1 - Janser, Frank A1 - Havermann, Marc T1 - Inkompressible Strömungen Y1 - 2012 SN - 978-3-86130-446-3 N1 - Strömungslehre und Aerodynamik PB - Mainz CY - Aachen ER - TY - JOUR A1 - Jochim, Haldor E. T1 - Die Ostheidebahn - eine Alternative zur Y-Trasse JF - ETR - Eisenbahntechnische Rundschau Y1 - 2012 SN - 0013-2845 VL - 61 IS - 11 SP - 34 EP - 37 PB - DVV Media Group CY - Hamburg ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Detaillierte Berechnung der Einfangwirksamkeiten von Fangeinrichtungen JF - Elektro-Praktiker N2 - Im Beitrag wird zunächst das Verfahren eines dynamischen elektro-geometrischen Modells vorgestellt. Dieses arbeitet im Gegensatz zum klassischen Blitzkugel-Verfahren nicht mit konstanten Radien; vielmehr wird der Radius der Blitzkugel variiert. Dabei werden ausschließlich vorhandene und in internationalen Normen anerkannte Ergebnisse, blitzphysikalische Grundlagen und Untersuchungen verwendet, und auf deren Grundlage ein numerisches Verfahren erarbeitet. Mit dem dynamischen elektro-geometrischen Modell werden dann einige Beispiele des Schutzes mit Fangstangen, die gemäß dem klassischen Blitzkugel-Verfahren nach DIN EN 62305-3 für die Schutzklassen I – II – III – IV geplant sind, untersucht. Es wird gezeigt, dass die Einfangwirksamkeiten wesentlich höher sind als in der Normenreihe DIN EN 62305 selbst angegeben. Grund dafür ist die Tatsache, dass das Blitzkugel-Verfahren sehr konservativ aufgebaut ist und dem Planer von Blitzschutzsystemen nur die möglichen Stellen für einen Einschlag aufzeigt, ohne eine Bewertung der Einschlagshäufigkeit zu liefern. Andererseits bedeutet dies jedoch, dass man mit dem klassischen Blitzkugel-Verfahren stets auf der „sicheren Seite“ liegt. Y1 - 2012 SN - 0013-5569 VL - 66 IS - 4 PB - Huss Medien CY - Berlin ER - TY - CHAP A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Calculation of interception efficiencies for mesh-type air-terminations according to IEC 62305-3 using a dynamic electro-geometrical model T2 - International Conference on Lightning Protection (ICLP) : 2 - 7 Sept. 2012, Vienna Y1 - 2012 SN - 978-1-4673-1896-9 (E-Book) ; 978-1-4673-1898-3 (Print) SP - 1 EP - 6 PB - IEEE CY - Piscataway, NJ ER - TY - JOUR A1 - Kirchhof, Michael A1 - Kraft, Bodo T1 - Hybrides Vorgehensmodell : Agile und klassische Methoden im Projekt passend kombinieren JF - ProjektMagazin N2 - Agil ist im Trend und immer mehr Unternehmen, die ihre Projekte bisher nach klassischen Prinzipien durchführten, denken über den Einsatz agiler Methoden nach. Doch selbst wenn die Organisation bereits beide Philosophien unterstützt, gilt für ein Projekt meist die klare Vorgabe: agil oder klassisch. Es gibt aber noch einen anderen Ansatz, mit diesen "unterschiedlichen Welten" umzugehen: Und zwar die beiden Philosophien innerhalb eines Projekts zu kombinieren. Wie dies in der Praxis aussehen und gelingen kann, zeigen Dr. Michael Kirchhof und Prof. Dr. Bodo Kraft in diesem Beitrag. Y1 - 2012 IS - 11 SP - 11 S. PB - Berleb Media CY - Taufkirchen ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Rysstad, Gunnar A1 - Schöning, Michael Josef A1 - Keusgen, Michael T1 - Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry JF - Sensors and Actuators B: Chemical N2 - A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 μm) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 °C/(%, v/v) in a H2O2 concentration range of 0%, v/v to 8%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 °C and 270 °C of the gas stream. At flow rates of the gas stream from 8 m3/h to 12 m3/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m3/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes. KW - Sterilisation process KW - Hydrogen peroxide KW - Polyimide KW - Calorimetric gas sensor Y1 - 2012 U6 - https://doi.org/10.1016/j.snb.2011.01.032 SN - 0925-4005 N1 - Part of special issue "Eurosensors XXIV, 2010" VL - 170 SP - 60 EP - 66 PB - Elsevier CY - Amsterdam ER -