TY - CHAP A1 - Pauksztat, Anja A1 - Kuperjans, Isabel A1 - de Hesselle, M. T1 - Referenzformeln für Energiebedarf und CO2-Emissionen in der Glasindustrie T2 - Energieeffizienz - Chancen für die Zukunft : Tagung Berlin, 14. und 15. November 2006. - (VDI-Berichte ; 1951) Y1 - 2006 SN - 3-18-091951-5 SP - 179 EP - 190 PB - VDI-Verl. CY - Düsseldorf ET - Nichtred. Ms.-Dr. ER - TY - CHAP A1 - Küppers, Christine A1 - Groebel, Simone A1 - Kuperjans, Isabel A1 - Dielmann, Klaus-Peter T1 - Molekulargenetische Analysen zur Optimierung der Biogasgewinnung T2 - Biogas 2011 : 4. Innovationskongress ; Effizienzsteigerung von Biogasanlagen ; Vorstellung der 17 besten Biogas-Innovationen der letzten 12 Monate ; 12. - 13. Mai 2011, im ZUK der Deutschen Bundesstiftung Umwelt ; Tagungsband Y1 - 2011 SN - 978-3-9813776-1-3 SP - 45 EP - 48 PB - Profair Consult+Project CY - Hildesheim ER - TY - CHAP A1 - Kaspar, K. A1 - Groebel, Simone A1 - Kuperjans, Isabel A1 - Dielmann, Klaus-Peter A1 - Selmer, Thorsten T1 - Charakterisierung der Biozönose von Biogasfermentern in Abhängigkeit verschiedener Substrate T2 - Biogas 2013 : 6. Innovationskongress, 23. - 24.05.2013, Osnabrück, Tagungsband Y1 - 2013 SN - 978-3-9813776-3-7 SP - 69 EP - 74 PB - Profair Consult+Project CY - Hildesheim ER - TY - CHAP A1 - Scheibe, K. A1 - Kern, Alexander T1 - Stand der Normung für Überspannungsschutzgeräte T2 - 10. VDE, VBB-Blitzschutztagung : Vorträge der 10. VDE, ABB-Fachtagung vom 24. bis 25. Oktober 2013 in Neu-Ulm. (VDE-Fachbericht ; 70) Y1 - 2013 SN - 978-3-8007-3540-2 SP - 23 EP - 27 PB - VDE-Verl. CY - Berlin ER - TY - CHAP A1 - Kern, Alexander T1 - Die neue DIN EN 62305-2 (VDE 0185-305-2) Ed.2:2013-02 - Änderungen zur Ed.l und zugehörige Beiblätter T2 - 10. VDE, VBB-Blitzschutztagung : Vorträge der 10. VDE, ABB-Fachtagung vom 24. bis 25. Oktober 2013 in Neu-Ulm. (VDE-Fachbericht ; 70) Y1 - 2013 SN - 978-3-8007-3540-2 SP - 9 EP - 16 PB - VDE-Verl. CY - Berlin ER - TY - CHAP A1 - Kumaran, P. A1 - Gopinathan, M. A1 - Razali, N. M. A1 - Kuperjans, Isabel A1 - Hariffin, B. A1 - Hamdan, H. T1 - Preliminary evaluation of atomization characteristics of improved biodiesel for gas turbine application T2 - IOP Conference Series: Earth and Environmental Science (EES) Y1 - 2013 U6 - http://dx.doi.org/10.1088/1755-1315/16/1/012014 SN - 1755-1315 VL - 16 IS - 1 SP - 012014/1 EP - 012014/4 PB - Institute of Physics Publishing (IOP) CY - London [u.a.] ER - TY - CHAP A1 - Rens, Gavin A1 - Ferrein, Alexander A1 - Poel, Etienne van der T1 - Extending DTGolog to deal with POMD-Ps T2 - Proceedings of the Nineteenth Annual Symposium of the Pattern Recognition Association of South Africa (PRASA 2008) Y1 - 2008 SP - 49 EP - 54 ER - TY - CHAP A1 - Pieper, Martin A1 - Konopka, Mahnaz T1 - Umgestaltung der Mathematik Anfängervorlesungen im Fachbereich Energietechnik T2 - Mathematik im Übergang Schule/Hochschule und im ersten Studienjahr : extended abstracts zur 2. khdm-Arbeitstagung 20.02. - 23.02.2013. (khdm-Report ; 13-01) Y1 - 2013 SP - 115 EP - 116 ER - TY - CHAP A1 - Hellmanns, Mark A1 - Hesse, Joachim T1 - Geräuschminderung und Leichtbau in Leistungsgetrieben durch den Einsatz von Werkstoffverbunden T2 - Hybride Maschinenkonzepte und intelligente Verfahren zur Fertigung von High-Tech-Produkten : Erfolgsbeispiele zur Standortsicherung in Hochlohnländern : InnoNet Kolloquium am 7. und 8.11.2007, Technologiezentrum am Europaplatz Aachen Y1 - 2007 SP - 1 EP - 46 ER - TY - CHAP A1 - Feldhusen, Jörg A1 - Brezing, Alexander Nikolaus A1 - Pütz, Claus A1 - Wählisch, Georg T1 - Multi-system CAD-teaching in large classes T2 - When design education and design research meet : proceedings of the 12th International Conference on Engineering and Product Design Education, Norwegian University of Science and Technology (NTNU) Trondheim, Norway, 2nd - 3rd September 2010 ; [E&PDE] Y1 - 2010 SN - 978-1-904670-19-3 SP - 204 EP - 209 PB - Design Society CY - Glasgow ER - TY - CHAP A1 - Takenaga, Shoko A1 - Herrera, Cony F. A1 - Werner, Frederik A1 - Biselli, Manfred A1 - Schnitzler, Thomas A1 - Schöning, Michael Josef A1 - Öhlschläger, Peter A1 - Wagner, Torsten T1 - Detection of the metabolic activity of cells by differential measurements based on a single light-addressable potentiometric sensor chip T2 - 11. Dresdner Sensor-Symposium : 9.-11.12.2013 Y1 - 2013 SN - 978-3-9813484-5-3 SP - 63 EP - 67 ER - TY - CHAP A1 - Stollenwerk, Dominik A1 - Kuvarakul, T. A1 - Kuperjans, Isabel T1 - Renewable energy supply for power dominated, energy intense production processes - a systematic conversion approach for the anodizing process T2 - IOP conference series: Earth and environmental science (EES) Y1 - 2013 SN - 1755-1315 SN - 1755-1307 VL - Vol. 16 IS - H. 1 SP - 012142/1 EP - 012142/4 ER - TY - CHAP A1 - Goldbach, Daniel A1 - Ament, Christoph ED - Scharff, Peter T1 - Stabilized reversing with vehicle trailer combinations T2 - Crossing borders within the ABC : automation, biomedical engineering and computer science; proceedings; 55. IWK Internationales Wissenschaftliches Kolloquium; 13 - 17 September 2010, Ilmenau Y1 - 2010 SN - 978-3-938843-53-6 SP - 352 EP - 357 PB - Verl. ISLE CY - Ilmenau ER - TY - CHAP A1 - Goldbach, Daniel T1 - Management der funktionalen Sicherheit einer Entwicklung eines sicherheitskritischen Systems im Bereich Nutzfahrzeuge T2 - Commercial vehicle technology 2010 : proceedings of the 1st Commercial Vehicle Technology Symposium (CVT 2010), March 16 - 18, 2010, Kaiserslautern / K. Berns ... (ed.) Y1 - 2010 SN - 978-3-8322-9040-5 SP - 487 EP - 495 PB - Shaker CY - Aachen ER - TY - CHAP A1 - Hellmanns, Mark A1 - Fischer, F. A1 - Dilger, Klaus T1 - Applikation und Einsatz von faserverstärkten Klebstoffen im Bauwesen T2 - Tagungsband / 13. Kolloquium Gemeinsame Forschung in der Klebtechnik : 26. und 27. Februar 2013, Frankfurt am Main Y1 - 2013 SP - 61 EP - 62 PB - DECHEMA CY - Frankfurt a.M. ER - TY - CHAP A1 - Hellmanns, Mark A1 - Hartung, I. A1 - Dilger, Klaus A1 - Böhm, Stefan T1 - Quality assurance of manual guided joining and welding devices T2 - Proceedings of the IIW International Conference on Advances in Welding and Allied Technologies : July 16 - 17, 2009, Singapore Y1 - 2009 SN - 9789810832605 SP - 219 EP - 222 PB - International Institute of Welding CY - Roissy ER - TY - CHAP A1 - Böhm, Stefan A1 - Hellmanns, Mark A1 - Backes, Andreas A1 - Dilger, Klaus T1 - Lock-in thermography based NDT of automotive parts T2 - Proceedings of the 3rd World Congress on Adhesion and Related Phenomena : WCARP-III, October 15 -18, 2006, Beijing, China Y1 - 2006 SP - 382 EP - 384 PB - Beijing Adhesion Society of China CY - Beijing ER - TY - CHAP A1 - Hellmanns, Mark A1 - Böhm, Stefan A1 - Dilger, Klaus T1 - Progress of the manual application of adhesives T2 - Proceedings of the 3rd World Congress on Adhesion and Related Phenomena : WCARP-III, October 15 -18, 2006, Beijing, China Y1 - 2006 SP - 275 EP - 277 PB - Beijing Adhesion Society of China CY - Beijing ER - TY - CHAP A1 - Hellmanns, Mark A1 - Böhm, Stefan A1 - Dilger, Klaus A1 - Welters, T. T1 - Neue Möglichkeiten der Klebstoffverarbeitung durch geschwindigkeitsproportionalen Handauftrag T2 - Adhesive bonding and hybrid bonding in body-in-white shop and assembly : proceedings, 25/26 April 2006, Bad Nauheim/Frankfurt Y1 - 2006 SP - 81 PB - Technik & Kommunikation Verl.-GmbH CY - Berlin ER - TY - CHAP A1 - Hellmanns, Mark A1 - Böhm, Stefan A1 - Dilger, Klaus T1 - Implementation of a velocity controlled manual applicator for adhesives and sealants in the automotive industry in consideration of quality control T2 - Proceedings of the 29th annual meeting of the Adhesion Society : 19. - 22.2.2006, Jacksonville, Florida Y1 - 2006 SN - 1086-9506 SP - 68 EP - 70 PB - Adhesion Society CY - Blacksburg, Va. ER - TY - CHAP A1 - Hellmanns, Mark A1 - Böhm, Stefan A1 - Dilger, Klaus T1 - Weight and noise reduction in power transmissions through epoxy resin foams T2 - Proceedings of the 31st annual meeting of the Adhesion Society : 17. - 20.2.2008, Austin, Texas Y1 - 2008 SP - 291 EP - 293 PB - Adhesion Society CY - Blacksburg ER - TY - CHAP A1 - Hartung, I. A1 - Dilger, Klaus A1 - Hellmanns, Mark A1 - Böhme, Stefan T1 - Repair of non-weldable steel structures to extend the life cycle T2 - Proceedings of the IIW International Conference on Advances in Welding and Allied Technologies : July 16 - 17, 2009, Singapore. (Welding in the world ; 53.2009, special issue) Y1 - 2009 SN - 978-981-08-3259-9 SP - 569 EP - 574 PB - Springer CY - Berlin [u.a.] ER - TY - CHAP A1 - Werner, Frederik A1 - Mansour, Ahmed A1 - Rateike, Franz-Matthias A1 - Schusser, Sebastian A1 - Wagner, Torsten A1 - Yoshinobu, Tatsuo A1 - Keusgen, Michael A1 - Schöning, Michael Josef ED - Gerlach, Gerald T1 - Kompakter Aufbau eines lichtadressierbaren potentiometrischen Sensors mit verfahrbarem Diodenlaser T2 - 10. Dresdner Sensor-Symposium : Dresden, 5. - 7. Dezember 2011 ; miniaturisierte analytische Verfahren, Hochtemperatur-Sensoren, Sensoren für Bioprozess- und Verfahrenstechnik, Sensoren für die Medizin, Chemische Verfahrenstechnik, Lebensmittelanalytik, innovative Sensorlösungen, Sensoren für die Wasserqualität, Selbstüberwachung / Gerald Gerlach ... (Hg.) Dresdner Beiträge zur Sensorik. 43 Y1 - 2011 SN - 978-3-942710-53-4 SP - 277 EP - 280 PB - TUDpress CY - Dresden ER - TY - CHAP A1 - Gerling, Ulrich A1 - Vogelsang, D. T1 - Temperaturfeldberechnungen mit ASKA unter Berücksichtigung des Phasenübergangs fest/flüssig T2 - FEM '89 Congress : International FEM-Congress, Baden-Baden, Federal Republic of Germany, 20./21. November 1989 Y1 - 1989 SP - 295 EP - 314 PB - IKOSS CY - Stuttgart ER - TY - CHAP A1 - Pfundt, H. A1 - Vogelsang, D. A1 - Gerling, Ulrich T1 - Calculation of the crust profile in aluminium reduction cells by thermal computer modelling T2 - Light metals 1989 : 118th annual meeting of the Minerals, Metals and Materials Society, Las Vegas, NV, Feb. 27 - Mar. 03. 1989 Y1 - 1988 SP - 371 EP - 377 PB - Minerals, Metals and Materials Soc. CY - Warrendale, Pa. ER - TY - CHAP A1 - Martin, S. A1 - Berg, G. A1 - Hardt, Arno A1 - Hürlimann, W. A1 - Köhler, M. A1 - Meißberger, J. A1 - Sagefka, T. A1 - Schult, O. W. B. ED - Sanderson, N. E. T1 - First experience with the magnet spectrometer 'BIG KARL' T2 - Use of magnetic spectrometers in nuclear physics : proceedings of the Daresbury study weekend 10 - 11 March 1979 Y1 - 1979 SP - 38 EP - 42 PB - Daresbury Lab. CY - Daresbury ER - TY - CHAP A1 - Haissig, M. A1 - Dören, Horst-Peter A1 - Stadler, P. T1 - The horizontal continuous casting process of steel - a contribution to the economic production of unalloyed, alloyed and high alloyed steel T2 - VOEST-Alpine Continuous Casting Conference : 12.-15. 10.1981, Johannes-Keppler-Universität Linz Y1 - 1981 SP - Vortrag 21 CY - Linz ER - TY - CHAP A1 - Dören, Horst-Peter T1 - The examination of surfaces of cold rolled wire for gas-shielded arc-welding T2 - WAI/BISPA joint conference : proceedings. Joint conference of Wire Association International and the British Independent Steel Producers Association (WAI/BISPA) : 26 - 27. 09. 1988, Stratford-upon-Avon Y1 - 1988 SP - 102 EP - 112 CY - Guilford, Conn. ER - TY - CHAP A1 - Dören, Horst-Peter A1 - Kröschel, R. ED - Dilthey, Ulrich T1 - Plasma-Spritzen T2 - Schweisszusatzwerkstoffe : Fortschritte, Erfahrungen, Tendenzen. 2. Aachener Schweisstechnik-Kolloquium, 7. bis 8. März 1991 Y1 - 1991 SN - 3-18-140802-6 SP - 147 EP - 167 PB - VDI-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Dören, Horst-Peter A1 - Molitor, M. A1 - Ertl, Karl-Heinz ED - Lugscheider, Erich T1 - Problematik der Härtemessung an pulverflammgespritzten Verschleißschutzschichten mit Hilfe mobiler, dynamischer Härteprüfverfahren T2 - Thermische Spritzkonferenz : TS 96 ; Vorträge und Posterbeiträge. Essen 6. bis 8. März 1996. DVS-Berichte. Bd. 175 Y1 - 1996 SN - 3-87155-480-4 SP - 249 EP - 254 PB - DVS-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Dören, Horst-Peter A1 - Lohrmann, G. R. A1 - Wernicke, K. T1 - Plasma-Auftragschweißen mit Metallpulvern und Einsatzmöglichkeiten in der Kerntechnik T2 - Schweissen in der Kerntechnik : Vorträge : internationales Kolloquium. 5 = Welding in nuclear engineering: international conference. 5 = Le soudage dans la technique nucleaire: colloque international. 5 : Nürnberg, 26.11.86-28.11.86. DVS-Berichte. Bd. 106 Y1 - 1986 SN - 3-87155-411-1 SP - 129 EP - 133 PB - Dt. Verl. für Schweißtechnik CY - Düsseldorf ER - TY - CHAP A1 - Dören, Horst-Peter A1 - Wernicke, K. T1 - Auftragen von verschleißfesten stranggegossenen Hartlegierungen auf Kobaltbasis durch das WIG- und Gasschweißen T2 - Schweißen und Schneiden '83 = Welding and Cutting '83. Vorträge der Großen Schweißtechnischen Tagung in Aachen vom 28. bis 30. September 1983. Veranst.: Deutscher Verband für Schweißtechnik (DVS). DVS-Berichte. 83 Y1 - 1983 SN - 3-87155-388-3 SP - 109 EP - 113 PB - Dt. Verl. für Schweißtechnik CY - Düsseldorf ER - TY - CHAP A1 - Hardt, Arno A1 - Abdel-Gawad, A A1 - Martin, S. A1 - Reich, J. T1 - Design procedures for the Juelich QQDDQ high resolution spectrometer T2 - Proceedings, 5th International Conference on Magnet Technology (MT-5) : Rome, Italy, April 21-25, 1975 Y1 - 1975 SP - 45 EP - 51 ER - TY - CHAP A1 - Behrens, Jörg A1 - Frentzel, Ralf A1 - Kern, Alexander T1 - Simulation der transienten Spannungsverläufe im Eigenbedarfsnetz eines Großkraftwerks bei einem kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung T1 - Simulation of transient voltage curve of a house-load operation net-work of large power plant by a lightning strike in a high-voltage over-head line closed to the power plant N2 - 8. VDE/ABB-Blitzschutztagung, 29. - 30. Oktober 2009 in Neu-Ulm. Blitzschutztagung <8, 2009, Neu-Ulm> Berlin : VDE Verl. 2009 Großkraftwerke können durch Blitzentladungen mit potentiellen Auswirkungen auf deren Verfügbarkeit und Sicherheit gefährdet werden. Ein sehr spezielles Szenario, welches aus aktuellem Anlass zu untersuchen war, betrifft den kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung am Netzanschluss der Anlage. Wird nun noch ein sogenannter Schirmfehler unterstellt, d.h. der direkte Blitzeinschlag erfolgt in ein Leiterseil des Hoch- bzw. Höchstspannungsnetzes und nicht in das darüber gespannte Erdseil, so bedeutet dies eine extreme elektromagnetische Einwirkung. Der vorliegende Beitrag befasst sich mit der Simulation eines solchen Blitzeinschlages und dessen Auswirkungen auf den Netzanschluss und die Komponenten der elektrischen Eigenbedarfsanlagen eines Kraftwerks auf den unterlagerten Spannungsebenen. Die dabei gewonnenen Erkenntnisse lassen sich ohne Einschränkungen auf Industrieanlagen mit Mittelspannungs-Netzanschluss und ohne eigener Stromversorgung übertragen. N2 - Lightning discharge can endanger large power plants with potential influence on their availability and reliability. A very special scenario, which was currently to analyse, is the lightning strike close to the high-voltage overhead line at the grid of the power plant. Supposing a failure of shielding and that the lightning strike goes directly into the line then the elec-tromagnetic effect is extremely high. The following article gives attention to the simulation of lightning strike and their effects to the connection with the grid and the components of the house-load operation of a large power plant especially to the lower voltage level sections. These results are transferable to industrial plants which have no own power supply. KW - Blitzschutz KW - Blitzeinschlag KW - lightning strike Y1 - 2009 SN - 978-3-8007-3197-8 ER - TY - CHAP A1 - Kern, Alexander A1 - Beierl, Ottmar A1 - Zischank, Wolfgang T1 - Calculation of the separation distance according to IEC 62305-3: 2006-10 - Remarks for the application and simplified methods N2 - [Paper of the X International Symposium on Lightning Protection 9th - 13th November, 2009 - Curitiba, Brazil. 6 pages] The international standard IEC 62305-3, published in 2006, requires as an integral part of the lightning protection system (LPS) the consideration of a separation distance between the conductors of the LPS and metal and electrical installations inside the structure to be protected. IEC 62305-3 gives two different methods for this calculation: a standard, simplified approach and a more detailed approach, which differ especially regarding the treatment of the current sharing effect on the LPS conductors. Hence, different results for the separation distance are possible, leading to some discrepancies in the use of the standard. The standard approach defined in the main part (Clause 6.3) and in Annex C of the standard in some cases may lead to a severe oversizing of the required separation distance. The detailed approach described in Annex E naturally gives more correct results. However, a calculation of the current sharing amongst all parts of the air-termination and downconductor network is necessary, in many cases requiring the use of network analysis programs. In this paper simplified methods for the assessment of the current sharing are presented, which are easy to use as well as sufficiently adequate. KW - Blitzschutz KW - Lightning protection Y1 - 2009 N1 - Paper in: [10. International Symposium on Lightning Protection 9. 13. November 2009, Curitiba, Brasilien. 6 Seiten] ER - TY - CHAP A1 - Kern, Alexander A1 - Dikta, Gerhard T1 - Probability of damage of electrical and electronic systems due to indirect lightning flashes - investigation of data from German insurance companies N2 - In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not. KW - Blitzschutz KW - lightning flash Y1 - 2009 ER - TY - CHAP A1 - Brüssermann, Klaus A1 - Deuster, M. T1 - Temperature measurement to optimise the burning process N2 - One of the most important parameters in a burning chamber - in power stations, in waste to energy plants - is the temperature. This temperature is in the range of 700-1500 °C - one of the most advanced measuring methods being the acoustic pyrometry with the possibility of producing temperature mapping in one level of the burning chamber - comparable to computer tomography. The results of these measurements discussed in the presentation can be used - to fulfil the legal requirements in the FRG or in the EU - to equalise the temperature in one level of the burning chamber to optimise the steam production (better efficiency of the plant) and to minimise the production of temperature controlled flue gas components (NO, CO a. o.) - to control the SNCR-process if used. KW - Pyrometrie KW - Temperaturmessung KW - temperature measurement KW - acoustic pyrometry KW - steam production KW - flue gas components Y1 - 2005 ER - TY - CHAP A1 - Brüssermann, Klaus T1 - Platform of Excellence in "Energy and Environment" N2 - The Ministry of Science and Research in North Rhine-Westphalia created eight platforms of excellence, one in the research area „Energy and Environment“ in 2002 at ACUAS. This platform concentrates the research and development of 13 professors in Jülich and Aachen and of two scientific institutes with different topics: – NOWUM-Energy with emphasis on efficient and economic energy conversion – The Solar Institute Jülich – SIJ – being the largest research institute in the field of renewables at a University of Applied Sciences in Germany With this platform each possible energy conversion – nuclear, fossil, renewable- can be dealt with to help solving the two most important problems of mankind, energy and potable water. At the CSE are presented the historical development, some research results and the combined master studies in „Energy Systems“ and „Nuclear Applications“ KW - Energietechnik KW - Kernenergie KW - Umwelt KW - Energy KW - environment KW - Energy Systems KW - Nuclear Applications Y1 - 2005 ER - TY - CHAP A1 - Dielmann, Klaus-Peter A1 - Schieke, Wolf T1 - Mikrogasturbinen - Aufbau und Anwendungen N2 - Mikrogasturbinen: Funktion, Aufbau, Hersteller, Bauformen, Rekuperatorparameter, Besonderheit der Konstruktion, Regelung, Regelbarkeit, Vergleich mit anderen Systemen, Wirkungs- und Nutzungsgrade, Schadstoffemissionen, Nutzung in Kraft-Wärme-Kopplung, Kraft-Wärme-Kälte-Kopplung KW - Gasturbine KW - Mikrogasturbine KW - Micro turbine Y1 - 2000 ER - TY - CHAP A1 - Dielmann, Klaus-Peter T1 - Umsetzung Strom-/Gasmarkt nach der Liberalisierung N2 - Neues Energierecht Strom Neues Energierecht Gas Emissionshandel in Europa - ein interessanter Markt? KW - Energierecht KW - Elektrizität KW - Gas KW - Emissionshandel Y1 - 2001 ER - TY - CHAP A1 - Dielmann, Klaus-Peter T1 - Darstellung des Erneuerbaren Energiegesetzes (EEG) und dessen Auswirkungen N2 - Erneuerbares Energien-Gesetz: Anwendungsbereich, Abnahme- und Vergütungspflicht, Vergütungssätze, Netzkosten, Ausgleichsregelungen Auswirkungen des EEG: Photovoltaik, Windkraft, Biomasse, Wasserkraft, Klär-, Deponie- und Grubengas, Geothermie Zusammenfassung und Ausblick KW - Energierecht KW - Erneuerbares Energiengesetz Y1 - 2002 ER - TY - CHAP A1 - Dielmann, Klaus-Peter A1 - Peters, Bernhard T1 - Micro Turbine Using Different Gases and Liquid Fuels N2 - Micro turbine using different gases and liquid fuels KW - Gasturbine KW - Mikrogasturbine KW - Micro turbine Y1 - 2002 ER - TY - CHAP A1 - Dielmann, Klaus-Peter A1 - Velden, Alwin van der T1 - Virtuelle Kraftwerke - Stand der Technik N2 - Ausgangslage, Funktionsprinzip des virtuellen Kraftwerkes, Energiemanagementsysteme (EMS), Einsatzgebiete, Anlagesysteme eines VKW's, Einsatzbereich der verschiedenen dezentralen Energieanlagen, Vorteile des virtuellen Kraftwerkes, Auswirkungen auf das elektrische Netz, Wirtschaftliche Aspekte, Beispielprojekte KW - Virtuelle Kraftwerke Y1 - 2003 ER - TY - CHAP A1 - Dielmann, Klaus-Peter A1 - Cudina, Boris T1 - Emissionsrechtehandel in Europa - ein neues Instrument für den Umweltschutz N2 - Funktionsprinzip Emissionsrechtehandel, Betroffene Anlagen und Branchen, Erstverteilung der Emissionsrechte, Bereits erbrachte Emissionsreduktionen (early actions), Ausstieg von betroffenen Unternehmen (opt-out), Teilnahme von nicht betroffenen Unternehmen, Einsatz von Biobrennstoffen, Erfassung und Dokumentation der Emissionen KW - Umweltzertifikathandel KW - Emissionsrechtehandel Y1 - 2003 ER - TY - CHAP A1 - Kern, Alexander T1 - Risikomanagement : Abschätzung des Schadensrisikos für bauliche Anlagen - Die neue Vornorm DIN V VDE V 0185 Teil 2 : 2002 N2 - Alle Unternehmen sind vielfältigen Risiken ausgesetzt, die Finanz- und Betriebsbereiche einschließlich Dienstleistungen betreffen können. Die Firmen müssen üblicherweise Risiken eingehen, um im Wettbewerb bestehen zu können. Entscheidend ist, dass man sich über die Risiken bewusst ist, diese einschätzen und kontrollieren kann. Falsche Einschätzungen, Versäumnisse und Fehlentscheidungen können empfindliche finanzielle Schäden bis hin zum Totalverlust nach sich ziehen. Ein effektives Risikomanagement ist heute als wichtiger Sicherheitsfaktor anzusehen und sollte zur strategischen Unternehmensführung gehören. Ein vorausschauendes Risikomanagement beinhaltet, Risiken für das Unternehmen zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent, welche Risiken sinnvollerweise über Versicherungen abgedeckt werden sollten. Beim Versicherungsmanagement ist jedoch zu bedenken, dass zur Erreichung bestimmter Ziele Versicherungen nicht geeignet sind (z.B. Erhaltung der Lieferfähigkeit). Eintrittswahrscheinlichkeiten bestimmter Risiken lassen sich durch Versicherungen nicht verändern. Bei Unternehmen, die mit umfangreichen elektronischen Einrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Berücksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nicht-Verfügbarkeit der elektronischen Einrichtungen und damit der Produktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardware-Schaden an der betroffenen Anlage oft bei weitem übersteigt. Im Blitzschutz gewinnt innovatives Denken in Schadensrisiken langsam an Bedeutung. Risikoanalysen haben die Objektivierung und Quantifizierung der Gefährdung von baulichen Anlagen und ihrer Inhalte durch direkte und indirekte Blitzeinschläge zum Ziel. Seinen Niederschlag hat dieses neue Denken in der neuen deutschen Norm DIN V 0185-2 VDE V 0185 Teil 2 gefunden. Die hier vorgegebene Risikoanalyse gewährleistet, dass ein für alle Beteiligten nachvollziehbares Blitzschutz-Konzept erstellt werden kann, das technisch und wirtschaftlich optimiert ist, d.h. bei möglichst geringem Aufwand den notwendigen Schutz gewährleisten kann. Die sich aus der Risikoanalyse ergebenden Schutzmaßnahmen sind dann in den weiteren Normenteilen der neuen Reihe VDE V 0185 detailliert beschrieben. KW - Blitzschutz KW - Risikomanagement KW - Risikoabschätzung KW - Versicherung KW - Lightning protection KW - Risk management KW - Risk assessment ; Insurance Y1 - 2002 ER - TY - CHAP A1 - Kern, Alexander T1 - Abschätzung des Blitzschadensrisikos für bauliche Anlagen - Die neue Bestimmung DIN V VDE V 0185 Teil 2 : 2002 - Allgemeines, Abschätzungsverfahren, Berechnungsbeispiele N2 - Ein vorausschauendes Risikomanagement beinhaltet, Risiken für das Unternehmen zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent, welche Risiken sinnvollerweise über Versicherungen abgedeckt werden sollten. Beim Versicherungsmanagement ist jedoch zu bedenken, dass zur Erreichung bestimmter Ziele Versicherungen nicht immer geeignet sind (z.B. Erhaltung der Lieferfähigkeit). Eintrittswahrscheinlichkeiten bestimmter Risiken lassen sich durch Versicherungen nicht verändern. Bei Unternehmen, die mit umfangreichen elektronischen Einrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Berücksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nicht-Verfügbarkeit der elektronischen Einrichtungen und damit der Produktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardware-Schaden an der betroffenen Anlage oft bei weitem übersteigt. Im Blitzschutz gewinnt innovatives Denken in Schadensrisiken langsam an Bedeutung. Risikoanalysen haben die Objektivierung und Quantifizierung der Gefährdung von baulichen Anlagen und ihrer Inhalte durch direkte und indirekte Blitzeinschläge zum Ziel. Seinen Niederschlag hat dieses neue Denken in der neuen deutschen Vornorm DIN V 0185-2 VDE V 0185 Teil 2 [1] gefunden. Die hier vorgegebene Risikoanalyse gewährleistet, dass ein für alle Beteiligten nachvollziehbares Blitzschutz-Konzept erstellt werden kann, das technisch und wirtschaftlich optimiert ist, d.h. bei möglichst geringem Aufwand den notwendigen Schutz gewährleisten kann. Die sich aus der Risikoanalyse ergebenden Schutzmaßnahmen sind dann in den weiteren Normenteilen der neuen Reihe VDE V 0185 [2, 3] detailliert beschrieben. KW - Blitzschutz KW - Risikomanagement KW - Risikoabschätzung KW - Lightning protection KW - Risk management KW - Risk assessment Y1 - 2003 ER - TY - CHAP A1 - Zischank, Wolfgang J. A1 - Kern, Alexander A1 - Frentzel, Ralf A1 - Heidler, Fridolin A1 - Seevers, M. T1 - Assessment of the lightning transient coupling to control cables interconnecting structures in large industrial facilities and power plants N2 - Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I&C-cables. KW - Blitzschutz KW - Elektromagnetische Kopplung KW - Überspannung KW - Kraftwerke KW - Industrieanlagen KW - Lightning KW - current distribution KW - electromagnetic coupling KW - overvoltages Y1 - 2000 ER - TY - CHAP A1 - Kern, Alexander A1 - Krichel, Frank A1 - Müller, Klaus-Peter T1 - Lightning protection design of a renewable energy hybrid-system without power mains connection N2 - In the year 2000 a direct lightning strike to the hybridsystem without power mains connection VATALI on the Greek island Crete results in the destruction and damage of some mechanical and electrical components. The hybrid-system VATALI was not lightning protected at that time. The hardware damage costs are approx. 60,000 €. The exposed site of the hybrid-system on top of a mountain was and still is the reason for a high risk of lightning strikes. Also in the future further lightning strikes have to be taken into consideration. In the paper a fundamental lightning protection design concept for renewable energy hybrid-systems without power mains connection and protection measures against direct strikes and overvoltages are shown in detail. The design concept was realized exemplarily for the hybrid-system VATALI. The hardware costs for the protection measures were about 15,000 €. About 50% of the costs are due to protection measures against direct strikes, 50% are due to overvoltage protection. Future extensions, new installations, or modifications have to be included into the lightning protection design concept of the hybrid-system. KW - Blitzschutz KW - Erneuerbare Energien KW - Hybridsystem KW - Lightning protection KW - Renewable energy KW - hybrid-system Y1 - 2001 ER - TY - CHAP A1 - Kern, Alexander A1 - Neskakis, Apostolos A1 - Müller, Klaus-Peter T1 - Blitzschutzkonzept für eine netz-autarke Hybridanlage am Beispiel der Anlage VATALI auf Kreta N2 - Netz-autarke Anlagen bestehen üblicherweise aus einer oder mehreren Photovoltaik- (PV-) Anlagen, ggf. auch Solarthermie- (ST-) Anlagen und einem oder mehreren kleineren Windgeneratoren (sie werden deshalb auch als Hybridanlagen bezeichnet) und werden vor allem in Gegenden mit sehr schlechter öffentlicher Energieversorgung eingesetzt, d.h. insbesondere in rel. dünn bewohnten Gebieten und in Entwicklungsländern. Der Blitzschutz von netz-autarken Hybridanlagen ist ein bislang noch vergleichsweise unzureichend bearbeitetes Fachgebiet. Für große Windenergie-Anlagen (WEA) wurde in den letzten Jahren eine Zahl von FuE-Projekten durchgeführt, zum Großteil finanziert durch die öffentliche Hand, zum kleineren Teil auch durch die Industrie, d.h. die WEAHersteller. Dabei wurden bestehende Defizite im Design der WEA festgestellt und Maßnahmen vorgeschlagen, die vor den mechanischen Zerstörungen insbesondere des Rotors und vor den Störungen und Zerstörungen an den elektrischen / elektronischen Systemen der WEA weitgehend Schutz bieten [1, 2, 3]. Der Stand-der- Normung ist im Entwurf DIN VDE 0127 Teil 24 „Blitzschutz für Windenergieanlagen“ (dt. Übersetzung des internationalen Drafts IEC 61400-24 „Wind turbine generator systems; Part 24: Lightning Protection“) dokumentiert [4]. Die Maßnahmen sind allerdings insbesondere für größere WEA vorgesehen; im Falle kleinerer WEA lassen sie sich nur bedingt umsetzen. Trotzdem sind auch kleinere WEA rel. stark blitzeinschlaggefährdet, wenn sie auf einer Bergkuppe o.ä. platziert werden. Für solche kleinere WEA, wie sie bei Hybridanlagen üblicherweise Verwendung finden, müssen die Blitzschutzmaßnahmen aus der DIN VDE 0127 Teil 24 angepasst werden. Für PV- und ST-Anlagen ist eine entsprechende Blitzschutz-Norm noch nicht in Sicht. Hier ist vor allem der Schutz gegen direkte Blitzeinschläge in die Anlage bzw. die Gebäude noch nicht ausreichend beachtet. Blitzfangeinrichtungen sind oft nicht vorgesehen. In aller Regel hat man dabei bisher eine Ausführungsform des Blitzschutzes realisiert, die primär einen Ferneinschlag berücksichtigt und die dabei entstehenden induzierten, rel. energieschwachen Überspannungen durch schwächere Schutzelemente wie Rückstromdioden, Bypassdioden und zum Teil thermisch überwachte Varistoren begrenzt [5, 6, 7]. Diese Schutzelemente können allerdings bei Naheinschlägen bzw. Direkteinschlägen überlastet und damit zerstört werden. Darüber hinaus können Nahoder Direkteinschläge auch zur Schwächung der elektrischen Festigkeit der PVModulisolierung führen. Die Folge davon sind lokale extreme Wärmeentwicklungen, die sogar ein Schmelzen von Glas (sekundärer Langzeiteffekt) hervorrufen könnten. Bei einem Blitzeinschlag in die netz-autarke Hybridanlage VATALI auf Kreta im Jahre 2000 wurden sowohl einige mechanische wie auch elektrische Komponenten der Anlage zerstört bzw. zum Teil schwer beschädigt. Die Anlage VATALI besaß zum Zeitpunkt des Blitzeinschlags keinen wirksamen Blitzschutz. Der Gesamtschaden der Hardware belief sich auf ca. 60.000,- EURO. Die exponierte Stellung der Anlage auf einer Bergspitze stellte und stellt nach wie vor ein enormes Blitzeinschlag-Risiko dar, so dass auch zukünftig mit Blitzeinwirkungen gerechnet werden muss. Die Anlage wurde inspiziert, blitzschutz-technische Erfordernisse definiert und daraus Ertüchtigungsmaßnahmen abgeleitet, die mit überschaubarem Aufwand realisierbar sind. KW - Blitzschutz KW - Hybridanlage KW - Regenerative Energieanlagen KW - Lightning protection KW - renewable energy KW - hybrid system Y1 - 2001 ER - TY - CHAP A1 - Kern, Alexander A1 - Meppelink, Jan T1 - Neue Möglichkeiten elektrischer Anschlüsse an die Bewehrung und Untersuchung der Wirkung von Blitzströmen in bewehrtem Beton N2 - Im Rahmen eines modernen Blitzschutzsystems für Stahlbeton-Bauten bietet es sich an, die Betonbewehrung zu benutzen: - Sie kann die Funktionen der Ableitungseinrichtungen und des Blitzschutz- Potentialausgleichs bei einem klassischen Gebäude-Blitzschutz übernehmen [1]; - Sie kann, ggf. bei entsprechender Ergänzung, als ein geschlossener Käfig ausgebildet werden und damit eine deutliche Reduzierung der Belastung elektrischer / elektronischer Systeme durch blitzinduzierte elektromagnetische Felder erbringen (LEMP-Schutz [2]). Die Nutzung der Bewehrung ist dabei grundsätzlich gleichermaßen bei Neubauten wie auch bei Ertüchtigungen möglich und sinnvoll. So stellt die Nutzung der Bewehrung beispielsweise im Bereich von Großkraftwerken eine wesentliche Ertüchtigungsmaßnahme für den Blitzschutz elektrischer und elektronischer Einrichtungen dar: - Einerseits wird der Blitzschutz-Potentialausgleich durch den Anschluss metallener Einrichtungen wie Elektronik-Schränke, Kabeltrag-Konstruktionen, Rohrleitungen, etc. an die Bewehrung deutlich verbessert. - Andererseits kann bei größeren Gebäuden die elektromagnetische Schirmwirkung durch die elektrische Überbrückung von vorhandenen Dehnfugen bei Stahlbetonbauten optimiert werden. Diese Dehnfugen sind teilweise nur unzureichend überbrückt, so dass bei Blitzeinschlag in das betreffende oder ein benachbartes Gebäude an Kabelstrecken, die über die Dehnfuge hinwegführen, rel. hohe Spannungen induziert werden können [2, 3]. Die sich um das gesamte Gebäude herumziehende oder zwischen zwei Gebäuden befindliche Dehnfuge muss deshalb im Abstand von maximal einigen Metern überbrückt werden. Im Falle von Blitzschutz-Ertüchtigungen in vorhandenen Gebäuden wird bisher an jeder geplanten Anschlussstelle die Bewehrung großflächig (∅ wenige 10 cm) freigelegt, dort ein elektrischer Anschluss zu dem Bewehrungsstab hergestellt, z.B. mittels eines Erdungsfestpunkts, und dann die Betonoberfläche wieder geschlossen. Je nach prognostizierter Strombelastung wird teilweise versucht, den über den Anschluss fließenden Strom bereits auf mehrere Bewehrungsstäbe zu verteilen. Dazu sind entweder die kreuzenden Stäbe zu verschweißen oder es sind direkt Anschlüsse an zwei Bewehrungsstäbe herzustellen. All dieses bedeutet einen hohen Aufwand bei der Freilegung der Bewehrung und auch wieder bei der Schließung der entstandenen Betonlöcher. Es soll deshalb hier untersucht werden, ob es beispielsweise zum Zwecke des Blitzschutz-Potentialausgleichs und auch zur Überbrückung von Dehnfugen ausreichend ist, den Anschluss an die Bewehrung nach einfachen Verfahren nur jeweils an einen Bewehrungsstab herzustellen. Damit würde der finanzielle und administrative Aufwand an Betonarbeiten deutlich reduziert. Die hier dargestellten Verfahren sind dabei insbesondere für den Einsatz bei Blitzschutz-Ertüchtigungen in bestehenden Gebäuden vorgesehen. Abschließend sollen deshalb die Möglichkeiten zur Prüfung korrekter Anschlüsse, die Grenzen der Verfahren sowie auch die Grenzen der Anwendbarkeit bei Neuanlagen diskutiert werden. KW - Blitzschutz KW - Stahlbetonkonstruktion KW - Lightning Protection KW - reinforced concrete Y1 - 2001 ER -