TY - JOUR A1 - Stollenwerk, Dominik A1 - Reinkensmeier, Sebastian A1 - Georg, Jörg Heiner A1 - Jungbluth, Christian T1 - „Smartes“ Laden an öffentlich zugänglichen Ladesäulen – Teil 2: USER-Verhalten und -Erwartungen JF - Energiewirtschaftliche Tagesfragen : et ; Zeitschrift für Energiewirtschaft, Recht, Technik und Umwelt Y1 - 2021 SN - 0720-6240 SN - 0013-743X VL - 71 IS - 3 SP - 38 EP - 42 PB - ETV Energieverlag CY - Essen ER - TY - JOUR A1 - Georg, Jörg Heiner A1 - Stollenwerk, Dominik A1 - Reinkensmeier, Sebastian A1 - Jungbluth, Christian T1 - „Smartes“ Laden an öffentlich zugänglichen Ladesäulen – Teil 1: Quo vadis, Marktdesign? JF - Energiewirtschaftliche Tagesfragen : et ; Zeitschrift für Energiewirtschaft, Recht, Technik und Umwelt Y1 - 2021 SN - 0720-6240 SN - 0013-743X VL - 71 IS - 1/2 SP - 64 EP - 69 PB - ETV Energieverlag CY - Essen ER - TY - CHAP A1 - Butenweg, Christoph A1 - Sadegh-Azar, H. A1 - Meskouris, Konstantin T1 - Seismische Vulnerabilität von bestehenden Bauwerken T2 - 5. Forum und Gefahrentag : auf der Suche nach dem Risiko : ein aktuelles Symposium zu Fragen der Risikowahrnehmung und Katastrophenvorsorge in Deutschland, ZDF Mainz Lerchenberg, 13. - 14. Oktober, 2004 Y1 - 2004 SP - 1 ER - TY - CHAP A1 - Borchert, Jörg A1 - Heimann, Thorsten A1 - Schemm, Ralf T1 - Speicheroptimierung T2 - Gashandel und Gasbeschaffung N2 - In dieser Lektion wurden beginnend mit der Darstellung des fundamentalen Wandels des Gasmarktes die daraus folgenden Implikationen für die Einsatzweise von Gasspeichern abgeleitet. Anschließend wurden zwei Bewertungs- und Steuerungsverfahren für einen Gasspeicher an den beiden Marktstufen Termin- und Spotmarkt methodisch vorgestellt und anhand von Beispielrechnungen illustriert. Das Verfahren zur Bewertung und Steuerung im Terminmarkt stellt ein sehr robustes und methodisch einfaches Verfahren dar. Hierbei wird die Saisonalität der Forwardkurve bzw. deren Veränderungen arbitragefrei mithilfe des Speichers ausgenutzt. Dieses Verfahren kann nicht den gesamten Zeitwert des Speichers ausweisen. Es zieht in jedem Zeitpunkt nur die aktuellen Informationen der Forwardkurve zur Entscheidung heran. Es bildet aber keine bedingte Erwartung über zukünftige Erträge und deren Beeinflussung durch die aktuelle Speicherfahrweise, um hieraus eine optimale Entscheidung zu formulieren. Bei der Bewertung gegenüber dem Spotmarkt mithilfe der Least-Squares-Monte- Carlo-Simulation wird in einer stochastischen Optimierung dagegen der volle Zeitwert des Speichers und damit der gesamte Zusatznutzen der Flexibilität ermittelt. Hierdurch leiten sich auch wesentlich andere Hedging-Empfehlungen als im ersten Verfahren ab, um diesen zu sichern. Der Einsatz der beiden Verfahren im Alltag zur Bewirtschaftung des Speichers hängt insbesondere vom Know-how, den Speicherparametern und der Risikobereitschaft des Handels ab. Beide Strategien liefern hierzu Hedging-Empfehlungen ab, mit welchem der zugrunde liegende Wert gesichert werden kann. Risikoaverse Händler, die einen Großteil des inneren Wertes sichern wollen, könnten im Terminmarkt einen Großteil des Speichers mithilfe des „Intrinsic Rolling“-Verfahrens bewirtschaften. Sie würden hierdurch den saisonalen Spread in der Forwardkurve rollierend sichern. Gleichzeitig kann ein kleinerer Anteil mithilfe der stochastischen Optimierung und den damit verbundenen Ausübungsgrenzen gegenüber dem Spotmarkt bewirtschaftet werden. In einem liquiden vollständigen Markt wird eine Steuerung des Speichers allein gegenüber den vorhandenen Marktstufen vorgenommen und der Wert für alle Marktteilnehmer objektiv messbar. Für den Fall, dass der Markt illiquide ist und hierdurch z. B. eine Kundenlast nicht allein am Termin- und Spotmarkt jederzeit gedeckt werden kann, erscheint es notwendig, den Speicher im Kontext einer Portfoliooptimierung zu bewerten. Dies wird in der nächsten Lektion vorgenommen. Hierbei ist aber zu beachten, dass der Speicher dadurch eine individualisierte Wertkomponente erhält, die von der konkreten Ausgestaltung des jeweiligen Portfolios abhängt. Y1 - 2011 SP - 1 EP - 69 PB - Euroforum Verl. CY - Düsseldorf ER - TY - CHAP A1 - Hellmanns, Mark A1 - Hesse, Joachim T1 - Geräuschminderung und Leichtbau in Leistungsgetrieben durch den Einsatz von Werkstoffverbunden T2 - Hybride Maschinenkonzepte und intelligente Verfahren zur Fertigung von High-Tech-Produkten : Erfolgsbeispiele zur Standortsicherung in Hochlohnländern : InnoNet Kolloquium am 7. und 8.11.2007, Technologiezentrum am Europaplatz Aachen Y1 - 2007 SP - 1 EP - 46 ER - TY - CHAP A1 - Behrens, Jörg A1 - Frentzel, Ralf A1 - Kern, Alexander T1 - Simulation der transienten Spannungsverläufe im Eigenbedarfsnetz eines Großkraftwerks bei einem kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung T1 - Simulation of transient voltage curve of a house-load operation net-work of large power plant by a lightning strike in a high-voltage over-head line closed to the power plant N2 - 8. VDE/ABB-Blitzschutztagung, 29. - 30. Oktober 2009 in Neu-Ulm. Blitzschutztagung <8, 2009, Neu-Ulm> Berlin : VDE Verl. 2009 Großkraftwerke können durch Blitzentladungen mit potentiellen Auswirkungen auf deren Verfügbarkeit und Sicherheit gefährdet werden. Ein sehr spezielles Szenario, welches aus aktuellem Anlass zu untersuchen war, betrifft den kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung am Netzanschluss der Anlage. Wird nun noch ein sogenannter Schirmfehler unterstellt, d.h. der direkte Blitzeinschlag erfolgt in ein Leiterseil des Hoch- bzw. Höchstspannungsnetzes und nicht in das darüber gespannte Erdseil, so bedeutet dies eine extreme elektromagnetische Einwirkung. Der vorliegende Beitrag befasst sich mit der Simulation eines solchen Blitzeinschlages und dessen Auswirkungen auf den Netzanschluss und die Komponenten der elektrischen Eigenbedarfsanlagen eines Kraftwerks auf den unterlagerten Spannungsebenen. Die dabei gewonnenen Erkenntnisse lassen sich ohne Einschränkungen auf Industrieanlagen mit Mittelspannungs-Netzanschluss und ohne eigener Stromversorgung übertragen. N2 - Lightning discharge can endanger large power plants with potential influence on their availability and reliability. A very special scenario, which was currently to analyse, is the lightning strike close to the high-voltage overhead line at the grid of the power plant. Supposing a failure of shielding and that the lightning strike goes directly into the line then the elec-tromagnetic effect is extremely high. The following article gives attention to the simulation of lightning strike and their effects to the connection with the grid and the components of the house-load operation of a large power plant especially to the lower voltage level sections. These results are transferable to industrial plants which have no own power supply. KW - Blitzschutz KW - Blitzeinschlag KW - lightning strike Y1 - 2009 SN - 978-3-8007-3197-8 ER - TY - CHAP A1 - Kern, Alexander A1 - Beierl, Ottmar A1 - Zischank, Wolfgang T1 - Calculation of the separation distance according to IEC 62305-3: 2006-10 - Remarks for the application and simplified methods N2 - [Paper of the X International Symposium on Lightning Protection 9th - 13th November, 2009 - Curitiba, Brazil. 6 pages] The international standard IEC 62305-3, published in 2006, requires as an integral part of the lightning protection system (LPS) the consideration of a separation distance between the conductors of the LPS and metal and electrical installations inside the structure to be protected. IEC 62305-3 gives two different methods for this calculation: a standard, simplified approach and a more detailed approach, which differ especially regarding the treatment of the current sharing effect on the LPS conductors. Hence, different results for the separation distance are possible, leading to some discrepancies in the use of the standard. The standard approach defined in the main part (Clause 6.3) and in Annex C of the standard in some cases may lead to a severe oversizing of the required separation distance. The detailed approach described in Annex E naturally gives more correct results. However, a calculation of the current sharing amongst all parts of the air-termination and downconductor network is necessary, in many cases requiring the use of network analysis programs. In this paper simplified methods for the assessment of the current sharing are presented, which are easy to use as well as sufficiently adequate. KW - Blitzschutz KW - Lightning protection Y1 - 2009 N1 - Paper in: [10. International Symposium on Lightning Protection 9. 13. November 2009, Curitiba, Brasilien. 6 Seiten] ER - TY - JOUR A1 - Wettingfeld, Jürgen A1 - Kern, Alexander A1 - Krämer, Heinz-Josef A1 - Thormählen, Reyno T1 - International anerkannte Blitzschutznormen : Ausgewogener und sicherer Schutz N2 - Die Einleitung zur Norm DIN EN 62305-3 beschreibt klar und ein - deutig: Der vorliegende Teil der IEC 62305 behandelt den Schutz von baulichen Anlagen gegen materielle Schäden und den Schutz von Personen gegen Verletzungen durch Berührungs- und Schrittspannungen. Als das wesentlichste und effektivste Mittel zum Schutz von baulichen Anlagen gegen materielle Schäden gilt das Blitz - schutzsystem (LPS). KW - Blitzschutz KW - lightning protection Y1 - 2009 PB - Fachhochschule Aachen CY - Aachen ER - TY - GEN A1 - Kaster, Jan Mathis T1 - Untersuchungen zur Specklereduktion bei der Infrarot-Laser gestützten Ferndetektion von TNT-Oberflächenkontaminationen T1 - Studies on specklereduction in the infrared laser based remote detection of TNT surface contaminations N2 - Das Ziel der vorliegenden Arbeit ist die Specklereduktion bei der Infrarotlaser-gestützten abbildenden Ferndetektion von TNT-Oberflächenkontaminationen. Für die Detektion wird die Probenoberfläche mit einem abstimmbaren Quantenkaskadenlaser bei verschiedenen Wellenzahlen im Spektralbereich von 1340cm-1 bis 1380cm-1 bestrahlt, während eine Infrarot-Kamera Bilder der bestrahlten Fläche aufzeichnet. Diese Bilder werden dann so verarbeitet, dass im Ausgabebild die chemisch spezifische TNT-Absorption durch eine Änderung der Helligkeit örtlich aufgelöst erkennbar werden. Da kohärente Strahlung, welche beispielsweise an optisch rauen Oberflächen reflektiert wird, aufgrund der stochastischen Verteilung der Oberflächenrautiefe mit der einfallenden Strahlung lateral unterschiedlich interferiert, entsteht ein „Rauschen“ in der aufgezeichneten Strahlungsleistungsverteilung, das sog. Speckle-Phänomen. Die Empfindlichkeit der oben skizzierten Lasergestützten Messtechnik wird im Wesentlichen durch diesen Effekt limitiert. Um die durch Laserspeckles verursachten Rauschanteile zu reduzieren, gibt es verschiedene Möglichkeiten. Durch Reduktion von zeitlicher und räumlicher Kohärenz der Strahlung wird deren Interferenzfähigkeit reduziert und durch Variieren des Specklemusters während einer Bildaufzeichnung führen Mittelungen unkorrelierter Rauschanteile zu einer Specklekontrastreduktion. Letztere Möglichkeit resultiert daraus, dass Laserspeckles statistisch durch die Familie der Gammaverteilungen beschrieben werden können. Demnach verbessert sich das Signal-zu-Rausch-Verhältnis mit der Anzahl gemittelter, unkorrelierter Rauschmuster proportional zur Wurzel dieser Anzahl. Ein im MIR-Spektralbereich umsetzbarer Ansatz, der all diese Möglichkeiten berücksichtigt, wurde bereits 1971 von Lowenthal und Joyeaux vorgeschlagen und im Rahmen der vorliegenden Arbeit für den infraroten Spektralbereich adaptiert. Dazu wird die Strahlung mit zwei CVD-Diamant-Wafern moduliert; ein Wafer ist dabei stationär und der andere rotiert mit ca. 70Hz. In der vorliegenden Arbeit konnte mit diesem Ansatz eine Verbesserung des Signal-zu-Rausch-Verhältnisses in der betrachteten Strahlungsleistungs¬verteilung von ursprünglich 3 auf etwa 45 erzielt werden. So konnten erstmals TNT-Kontaminationen von bis zu 10µg/cm² in einem Abstand von 5m abbildend nachgewiesen werden. Dies entspricht der Kontamination durch einen mit TNT leicht verunreinigten Fingerabdruck. KW - Speckle KW - Infrarot-Reflexions-Absorptions-Spektroskopie KW - MIR-Spektroskopie KW - Infrarotmesstechnik KW - Quantenkaskadenlaser KW - Fernerkundung KW - Trinitrotol Y1 - 2009 ER - TY - CHAP A1 - Dielmann, Klaus-Peter A1 - Schieke, Wolf T1 - Mikrogasturbinen - Aufbau und Anwendungen N2 - Mikrogasturbinen: Funktion, Aufbau, Hersteller, Bauformen, Rekuperatorparameter, Besonderheit der Konstruktion, Regelung, Regelbarkeit, Vergleich mit anderen Systemen, Wirkungs- und Nutzungsgrade, Schadstoffemissionen, Nutzung in Kraft-Wärme-Kopplung, Kraft-Wärme-Kälte-Kopplung KW - Gasturbine KW - Mikrogasturbine KW - Micro turbine Y1 - 2000 ER -