TY - CHAP A1 - Logen, Steffen A1 - Höfken, Hans A1 - Schuba, Marko T1 - Simplifying RAM Forensics : A GUI and Extensions for the Volatility Framework T2 - 2012 Seventh International Conference on Availability, Reliability and Security (ARES), 20-24 August 2012, Prague, Czech Republic N2 - The Volatility Framework is a collection of tools for the analysis of computer RAM. The framework offers a multitude of analysis options and is used by many investigators worldwide. Volatility currently comes with a command line interface only, which might be a hinderer for some investigators to use the tool. In this paper we present a GUI and extensions for the Volatility Framework, which on the one hand simplify the usage of the tool and on the other hand offer additional functionality like storage of results in a database, shortcuts for long Volatility Framework command sequences, and entirely new commands based on correlation of data stored in the database. Y1 - 2012 SN - 978-1-4673-2244-7 U6 - https://doi.org/10.1109/ARES.2012.12 SP - 620 EP - 624 PB - IEEE CY - New York ER - TY - BOOK A1 - Wosnitza, Franz A1 - Hilgers, Hans Gerd T1 - Energieeffizienz und Energiemanagement : ein Überblick heutiger Möglichkeiten und Notwendigkeiten Y1 - 2012 SN - 978-3-8348-1941-3 N1 - eISBN 978-3-8348-8671-2 PB - Springer Spektrum CY - Wiesbaden ER - TY - JOUR A1 - Hüning, Felix T1 - Using Trench PowerMOSFETs in Linear Mode JF - Power Electronics Europe (2012) N2 - If we think about applications for modern Power MOSFETs using trench technology, running them in linear mode may not be top of the priority list. Yet there are multiple uses for Trench Power MOSFETs in linear mode. In fact, even turning the device on and off in switching applications is a form of linear operation. Also, these components can be run in linear mode to protect the device against voltage surges. This article will illustrate the factors that need to be considered for linear operation and show how Trench Power MOSFETs are suited to it. Y1 - 2012 SN - 1748-3530 SP - 27 EP - 29 PB - DFA Media CY - Tonbridge ER - TY - CHAP A1 - Engels, Elmar A1 - Schnabel, Holger T1 - Rapid-control-prototyping of industrial drives for the sercos automation bus T2 - 13th International Workshop on Mechatronics (MECATRONICS), 2012 9th France-Japan & 7th Europe-Asia Congress on and Research and Education in Mechatronics (REM) N2 - This article describes the functionality of a MATLAB® library that can be used to develop motion-logic applications in MATLAB programming language for industrial drive and control systems using the well known sercos automation bus. Therewith MATLAB's functionality is extended to designing automation applications from single axis machines up to multi-kinematic robots. KW - MATLAB , MLPI , Motion control , Open Core , industrial drives , rapid control prototypin , sercos automation bus Y1 - 2012 UR - http://dx.doi.org/10.1109/MECATRONICS.2012.6451005 SN - 978-1-4673-4771-6 SP - 177 EP - 181 ER - TY - CHAP A1 - Nötzold, K. A1 - Uphues, A. A1 - Wegener, R. A1 - Soter, S. A1 - Fink, K. A1 - Bragard, Michael A1 - Griessel, R. T1 - Inverter based test setup for LVRT verification of a full-scale 2 MW wind power converter T2 - EPE Joint Wind Energy and T&D Chapters Seminar : 28th and 29th of June 2012, in the Utzon Centre, Aalborg, Denmark ; papers, posters, presentations. - Session 2: Grid connection, compliance Y1 - 2012 PB - EPE Association CY - Brussels ER - TY - JOUR A1 - Ferrein, Alexander A1 - Steinbauer, Gerald A1 - Vassos, Stavros T1 - Action-Based Imperative Programming with YAGI N2 - Many tasks for autonomous agents or robots are best described by a specification of the environment and a specification of the available actions the agent or robot can perform. Combining such a specification with the possibility to imperatively program a robot or agent is what we call the actionbased imperative programming. One of the most successful such approaches is Golog. In this paper, we draft a proposal for a new robot programming language YAGI, which is based on the action-based imperative programming paradigm. Our goal is to design a small, portable stand-alone YAGI interpreter. We combine the benefits of a principled domain specification with a clean, small and simple programming language, which does not exploit any side-effects from the implementation language. We discuss general requirements of action-based programming languages and outline YAGI, our action-based language approach which particularly aims at embeddability. Y1 - 2012 N1 - Cognitive Robotics AAAI Technical Report WS-12-06 SP - 24 EP - 31 ER - TY - CHAP A1 - Bitz, Andreas A1 - Kraff, O. A1 - Orzada, S. A1 - Maderwald, S. A1 - Brote, I. A1 - Johst, S. A1 - Ladd, E. T1 - Assessment of RF Safety of Transmit Coils at 7 Tesla by Experimental and Numerical Procedures (490.) T2 - 19th annual ISMRM scientific meeting and exhibition 2011 : Montreal, Quebec, Canada, 7 - 13 May 2011 Y1 - 2012 SN - 978-1-61839-284-8 IS - Volume 1 SP - 475 PB - Curran CY - Red Hook, NY ER - TY - JOUR A1 - Czarnecki, Christian A1 - Spiliopoulou, Myra T1 - A holistic framework for the implementation of a next generation network JF - International Journal of Business Information Systems N2 - As the potential of a next generation network (NGN) is recognised, telecommunication companies consider switching to it. Although the implementation of an NGN seems to be merely a modification of the network infrastructure, it may trigger or require changes in the whole company, because it builds upon the separation between service and transport, a flexible bundling of services to products and the streamlining of the IT infrastructure. We propose a holistic framework, structured into the layers ‘strategy’, ‘processes’ and ‘information systems’ and incorporate into each layer all concepts necessary for the implementation of an NGN, as well as the alignment of these concepts. As a first proof-of-concept for our framework we have performed a case study on the introduction of NGN in a large telecommunication company; we show that our framework captures all topics that are affected by an NGN implementation. KW - next generation network KW - telecommunication KW - NGN KW - IP-based networks KW - product bundling Y1 - 2012 U6 - https://doi.org/10.1504/IJBIS.2012.046291 SN - 1746-0972 VL - 9 IS - 4 SP - 385 EP - 401 PB - Inderscience Enterprises CY - Olney, Bucks ER - TY - JOUR A1 - Orzada, S. A1 - Maderwald, S. A1 - Poser, B. A. A1 - Johst, S. A1 - Kannengiesser, S. A1 - Ladd, M. E. A1 - Bitz, Andreas T1 - Time-interleaved acquisition of modes: an analysis of SAR and image contrast implications JF - Magnetic Resonance in Medicine N2 - s the magnetic field strength and therefore the operational frequency in MRI are increased, the radiofrequency wavelength approaches the size of the human head/body, resulting in wave effects which cause signal decreases and dropouts. Especially, whole-body imaging at 7 T and higher is therefore challenging. Recently, an acquisition scheme called time-interleaved acquisition of modes has been proposed to tackle the inhomogeneity problems in high-field MRI. The basic premise is to excite two (or more) different Burn:x-wiley:07403194:media:MRM23081:tex2gif-stack-1 modes using static radiofrequency shimming in an interleaved acquisition, where the complementary radiofrequency patterns of the two modes can be exploited to improve overall signal homogeneity. In this work, the impact of time-interleaved acquisition of mode on image contrast as well as on time-averaged specific absorption rate is addressed in detail. Time-interleaved acquisition of mode is superior in Burn:x-wiley:07403194:media:MRM23081:tex2gif-stack-2 homogeneity compared with conventional radiofrequency shimming while being highly specific absorption rate efficient. Time-interleaved acquisition of modes can enable almost homogeneous high-field imaging throughout the entire field of view in PD, T2, and T2*-weighted imaging and, if a specified homogeneity criterion is met, in T1-weighted imaging as well. Y1 - 2012 U6 - https://doi.org/10.1002/mrm.23081 SN - 1522-2594 VL - 67 IS - 4 SP - 1033 EP - 1041 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Kobus, Thiele A1 - Bitz, Andreas A1 - Uden, Mark J. van A1 - Lagemaat, Miram W. A1 - Rothgang, Eva A1 - Orzada, Stephan A1 - Heerschap, Arend A1 - Scheenen, Tom W. J. T1 - In vivo 31P MR spectroscopic imaging of the human prostate at 7 T: safety and feasibility JF - Magnetic Resonance in Medicine N2 - 31P MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D 31P MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a 31P endorectal coil was developed and combined with an eight-channel 1H body-array coil to relate metabolic information to anatomical location. An extensive safety validation was performed to evaluate the specific absorption rate, the radiofrequency field distribution, and the temperature distribution of both coils. This validation consisted of detailed Finite Integration Technique simulations, confirmed by MR thermometry and Burn:x-wiley:07403194:media:MRM24175:tex2gif-stack-1 measurements in a phantom and in vivo temperature measurements. The safety studies demonstrated that the presence of the 31P endorectal coil had no influence on the specific absorption rate levels and temperature distribution of the external eight-channel 1H array coil. To stay within a 10 g averaged local specific absorption rate of 10 W/kg, a maximum time-averaged input power of 33 W for the 1H array coil was allowed. For transmitting with the 31P endorectal coil, our safety limit of less than 1°C temperature increase in vivo during a 15-min MR spectroscopic imaging experiment was reached at a time-averaged input power of 1.9 W. With this power setting, a second in vivo measurement was performed on a healthy volunteer. Using adiabatic excitation, 3D 31P MR spectroscopic imaging produced spectra from the entire prostate in 18 min with a spatial resolution of 4 cm3. The spectral resolution enabled the separate detection of phosphocholine, phosphoethanolamine, inorganic phosphate, and other metabolites that could play an important role in the characterization of prostate cancer. Y1 - 2012 U6 - https://doi.org/10.1002/mrm.24175 SN - 1522-2594 VL - 68 IS - 6 SP - 1683 EP - 1695 PB - Wiley-Liss CY - New York ER -