TY - BOOK A1 - Staat, Manfred A1 - Heitzer, Michael T1 - Numerical methods for limit and shakedown analysis. Deterministic and probabilistic problems. Y1 - 2003 SN - 3-00-010001-6 N1 - NIC Series Vol. 15 / Ed. by Staat, M; Heitzer, M. PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael ED - Staat, Manfred ED - Heitzer, Michael T1 - Probabilistic limit and shakedown problems T2 - Numerical methods for limit and shakedown analysis. Deterministic and probabilistic problems Y1 - 2003 SN - 3-00-010001-6 N1 - NIC Series VL - 15 SP - 217 EP - 268 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - CHAP A1 - Yoshinobu, T. A1 - Schöning, Michael Josef A1 - Finger, F. A1 - Moritz, W. A1 - Iwasaki, H. T1 - Thin-film a-Si LAPS : Preparation and pH sensitivity T2 - Eurosensors XVII : the 17th European Conference on Solid-State Transducers ; University of Minho, Guimarães, Portugal, September 21 - 24, 2003 Y1 - 2003 SP - 88 EP - 89 ER - TY - CHAP A1 - Ermelenko, Y. A1 - Yoshinobu, T. A1 - Mourzina, Y. A1 - Schöning, Michael Josef A1 - Vlasov, Y. A1 - Iwasaki, H. T1 - A multisensor based on laser scanned silicon transducer (LSST): development and properties T2 - Eurosensors XVII : the 17th European Conference on Solid-State Transducers ; University of Minho, Guimarães, Portugal, September 21 - 24, 2003 Y1 - 2003 SP - 72 EP - 73 ER - TY - CHAP A1 - Moritz, Werner A1 - Yoshinobu, Tatsuo A1 - Finger, Friedhelm A1 - Krause, Steffi A1 - Schöning, Michael Josef T1 - Amorphous silicon as semiconductor material for high resolution LAPS T2 - Eurosensors XVII : the 17th European Conference on Solid-State Transducers ; University of Minho, Guimarães, Portugal, September 21 - 24, 2003 Y1 - 2003 SP - 48 EP - 49 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - IEEE Transactions on Nuclear Science N2 - A feasible way to gain the depth of interaction information in a positron emission tomography scanner is the use of phoswich detectors. In general, the layer of interaction is identified from the pulse shape of the corresponding scintillator material. In this work, pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could be kept simple because of an additional slow component in the light decay of the LuYAP pulse. At the same time, the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 0018-9499 VL - 50 IS - 3 SP - 344 EP - 347 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - 2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A feasible way to gain the depth of interaction information in a PET scanner is the use of phoswich detectors. In general the layer of interaction is identified front the pulse shape of the corresponding scintillator material. In this work pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could he kept simple due to an additional slow component in the light decay of the LuYAP pulse. At the same time the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 1082-3654 SP - 1636 EP - 1639 ER - TY - JOUR A1 - Heinrichs, U. A1 - Pietrzyk, U. A1 - Ziemons, Karl T1 - Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3 JF - IEEE Transactions on Nuclear Science N2 - Within the Crystal Clear Collaboration (CCC), four centers are developing second generation high performance small animal positron emission tomography (PET) scanners for different kinds of animals and medical applications. The first prototypes are photomultiplier tube (PMT)-based systems including depth of interaction (DOI) detection by using a phoswich layer of lutetium oxyorthosilicate (LSO) and lutetium yttrium aluminum perovskite (LuYAP). The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in fields of view (FOVs) caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN, Geneva, Switzerland) was used. Y1 - 2003 SN - 0018-9499 VL - 50 IS - 5 SP - 1428 EP - 1432 ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Svetlova, O. V. A1 - Makarov, F. N. A1 - Zaseeva, M. V. T1 - Morfologicheskie i funktsional'nye osobennosti resnichnogo poiaska khrustalika kak kliuchevogo ispolnitel'nogo zvena v mekhanizme akkommodatsii glaza cheloveka = Morpho-functional characteristics of lens ciliary body as a key mechanism of accommodation in JF - Morfologiia (Saint Petersburg, Russia). 123 (2003), H. 3 Y1 - 2003 SN - 1026-3543 N1 - Original in Russisch, English abstract SP - 7 EP - 16 PB - - ER - TY - BOOK A1 - Laack, Walter van T1 - A better history of our world / Vol. 3. Death Y1 - 2003 SN - 978-3-936624-01-4 N1 - [Eine bessere Geschichte unserer Welt ] PB - van Laack CY - Aachen ER - TY - BOOK A1 - Grotendorst, Johannes T1 - ComputerMathematik mit Maple / 2. Aufl. Y1 - 2003 SN - 3-89336-354-8 N1 - Schriften des Forschungszentrums Jülich : Reihe Informationstechnik ; 5 PB - Forschungszentrum Jülich CY - Jülich ER - TY - BOOK A1 - Grotendorst, Johannes T1 - ComputerMathematik mit Maple Y1 - 2003 SN - 3-89336-325-4 PB - Forschungszentrum Jülich CY - Jülich ER - TY - JOUR A1 - Hekmat, Khosro A1 - Kanani, Reza A1 - Lauterbach, Gerhard A1 - Südkamp, Michael A1 - Ahmadpoor, Tooraj A1 - Weber, Hans-Joachim A1 - Mehlhorn, Uwe T1 - Moderne Herzschrittmachersysteme wenig störanfällig durch Mobilfunktelefone JF - Deutsches Ärzteblatt. 100 (2003), H. 38 Y1 - 2003 SP - A2438 EP - A2445 ER - TY - BOOK A1 - Sander, Volker T1 - Design and evaluation of a bandwidth broker that provides network quality of service for grid applications Y1 - 2003 SN - 3-00-010002-4 N1 - NIC series ; 16 ; Zugl. Aachen, Techn. Hochsch., Diss., 2002 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Cavdar, C. A1 - Yenicerioglu, Y. A1 - Caliskan, S. T1 - The effects of intravenous iron treatment on oxidant stress and erythrocyte deformability in haemodialysis patients. Cavdar, C.; Temiz, A.; Yenicerioglu, Y.; Caliskan, S.; Celik, A.; Sifil, A.; Onvural, B.; Camsari, T. JF - Scandinavian Journal of Urology and Nephrology. 37 (2003), H. 1 Y1 - 2003 SN - 0036-5599 SP - 77 EP - 82 ER - TY - JOUR A1 - Schöning, Michael Josef T1 - Silicon-based field-effect structures – From dielectrics to bioelectronics JF - Dielectrics in emerging technologies : proceedings of the international symposium ; [papers presented at the First International Symposium on Science and Technology of Dielectrics in Emerging Fields held from 27th April to 2nd May 2003 in Paris, France] / sponsoring divisions: Dielectric Science and Technology, Electronics. Ed.: D. Misra. Y1 - 2003 SN - 1-56677-346-6 N1 - International Symposium on Science and Technology of Dielectrics in Emerging Fields ; (1, 2003, Paris) SP - 31 EP - 37 PB - Electrochemical Society CY - Pennington, NJ ER - TY - JOUR A1 - Yoshinobu, T. A1 - Ermelenko, Y. A1 - Mourzina, Y. A1 - Schöning, Michael Josef A1 - Iwasaki, H. A1 - Vlasov, Y. T1 - Multi-component analysis based on the light-addressable potentiometric sensor (LAPS) JF - Proceedings : 11th international conference Sensor 2003; 13 - 15 May 2003, Exhibition Centre Nuremberg, Germany Y1 - 2003 N1 - Internationale Messe mit Kongress Sensor <11, 2003, Nürnberg> SP - 141 EP - 144 PB - AMA Service CY - Wunstorf ER - TY - JOUR A1 - Ermelenko, Y. A1 - Yoshinobu, T. A1 - Mourzina, Y. A1 - Schöning, Michael Josef A1 - Furuichi, K. A1 - Levichev, S. A1 - Vlasov, Y. A1 - Iwasaki, H. T1 - The double K+/Ca2+ sensor based on laser scanned silicon transducer (LSST) for multicomponent analysis JF - Talanta. 59 (2003), H. 4 Y1 - 2003 SN - 0039-9140 SP - 785 EP - 795 ER - TY - JOUR A1 - Wang, J. A1 - Krause, R. A1 - Block, K. A1 - Musameh, M. A1 - Mulchandani, A. A1 - Schöning, Michael Josef T1 - Flow injection amperometric detection of OP nerve agents based on organophosphorus-hydrolase biosensor detector JF - Biosensors & Bioelectronics. 18 (2003), H. 2-3 Y1 - 2003 SN - 0956-5663 SP - 255 EP - 260 ER - TY - JOUR A1 - Mourzina, Y. G. A1 - Ermelenko, Y. E. A1 - Yoshinobu, T. A1 - Vlasov, Y. A1 - Iwasaki, H. A1 - Schöning, Michael Josef T1 - Anionselective light-addressable potentiometric sensors (LAPS) for the determination of nitrate and suphate ions JF - Sensors and Actuators B. 91 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 32 EP - 38 ER - TY - JOUR A1 - Simonis, A. A1 - Ruge, C. A1 - Müller-Veggian, Mattea A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - A long-term stable macroporoustype EIS structure for electrochemical sensor applications JF - Sensors and Actuators B. 91 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 21 EP - 25 ER - TY - JOUR A1 - Keusgen, M. A1 - Jünger, M. A1 - Krest, I. A1 - Schöning, Michael Josef T1 - Development of a biosensor specific for cysteine sulfoxides JF - Biosensors & Bioelectronics. 18 (2003), H. 5-6 Y1 - 2003 SN - 0956-5663 SP - 805 EP - 812 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Arzdorf, M. A1 - Mulchandani, P. A1 - Chen, W. A1 - Mulchandani, A. T1 - A capacitive field-effect sensor for the direct determination of organophosphorus pesticides JF - Sensors and Actuators B. 91 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 92 EP - 97 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schultze, J. W. A1 - Schöning, Michael Josef T1 - Multi-parameter detection of (bio-)chemical and physical quantities using an identical transducer principle JF - Sensors and Actuators B. 91 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 83 EP - 91 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Yoshinobu, Tatsuo A1 - Schöning, Michael Josef T1 - Flow-velocity microsensors based on semiconductor field-effect structures JF - Sensors. 3 (2003), H. 7 Y1 - 2003 SN - 1424-8220 SP - 202 EP - 212 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Thust, M. T1 - Die „Zukunftswerkstatt Biosensorik“ – ein Netzwerk für Lehre, Forschungs und Wirtschaft JF - Fachblatt Fachhochschule Aachen (2003) Y1 - 2003 SN - 1430-7707 SP - 6 EP - 7 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Arzdorf, M. A1 - Mulchandani, P. A1 - Chen, W. A1 - Mulchandani, A. T1 - Towards a capacitive enzyme sensor for direct determination of organophosphorus pesticides: Fundamentals studies and aspects of development JF - Sensors. 3 (2003), H. 6 Y1 - 2003 SN - 1424-8220 SP - 119 EP - 127 ER - TY - JOUR A1 - Simonis, A. A1 - Lüth, H. A1 - Wang, J. A1 - Schöning, Michael Josef T1 - Strategies of miniaturised reference electrodes integrated in a silicon-based „one chip“ pH sensor JF - Sensors. 3 (2003), H. 9 Y1 - 2003 SN - 1424-8220 SP - 330 EP - 339 ER - TY - JOUR A1 - Mourzina, Y. A1 - Mai, T. A1 - Poghossian, Arshak A1 - Ermolenko, Y. A1 - Yoshinobu, T. A1 - Vlasov, Y. A1 - Iwasaki, H. A1 - Schöning, Michael Josef T1 - K+-selective field-effect sensors as transducers for bioelectronic applications JF - Electrochimica Acta. 48 (2003), H. 20-22 Y1 - 2003 SN - 0013-4686 SP - 3333 EP - 3339 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schultze, J. W. A1 - Schöning, Michael Josef T1 - Application of a (bio-)chemical sensor (ISFET) for the detection of physical parameters in liquids JF - Electrochimica Acta. 48 (2003), H. 20-22 Y1 - 2003 SP - 3289 EP - 3297 ER - TY - JOUR A1 - Bressel, A. A1 - Schultze, J.W. A1 - Khan, W. A1 - Wolfaardt, G. M. A1 - Rohns, H.-P. A1 - Irmscher, R. A1 - Schöning, Michael Josef T1 - High resolution gravimetric, optical and electrochemical investigations of microbial biofilm formation in aqueous systems JF - Electrochimica Acta. 48 (2003), H. 20-22 Y1 - 2003 SN - 0013-4686 SP - 3363 EP - 3372 ER - TY - JOUR A1 - Yoshinobu, T. A1 - Schöning, Michael Josef A1 - Otto, R. A1 - Furuichi, K. A1 - Mourzina, Y. A1 - Ermelenko, Y. A1 - Iwasaki, H. T1 - Portable light-addressable potentiometric sensor (LAPS) for multisensor applications JF - Sensors and Actuators B. 95 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 352 EP - 356 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Berndsen, Lars A1 - Schöning, Michael Josef T1 - Chemical sensor as physical sensor: ISFET-based flowvelocity, flow-direction and diffusion-coefficient sensor JF - Sensors and Actuators B. 95 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 384 EP - 390 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Krause, R. A1 - Block, K. A1 - Musahmeh, M. A1 - Mulchandani, A. A1 - Wang, J. T1 - A dual amperometric/potentiometric FIA-based biosensor for the distinctive detection of organophosphorus pesticides JF - Sensors and Actuators B. 95 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 291 EP - 296 ER - TY - JOUR A1 - Thust, Marion A1 - Mulchandani, Ashok A1 - Wang, Joseph A1 - Arzdorf, Michael A1 - Mulchandani, Priti A1 - Chen, Wilfried A1 - Schöning, Michael Josef T1 - Feldeffekt-Enzymsensor zur Detektion von Pestiziden JF - Technisches Messen. 70 (2003), H. 12 Y1 - 2003 SN - 0171-8096 SP - 561 EP - 564 ER - TY - JOUR A1 - Keusgen, Michael A1 - Jünger, Martina A1 - Krest, Ingo A1 - Schöning, Michael Josef T1 - Biosensoric detection of the cysteine sulphoxide alliin JF - Sensors and Actuators B. 95 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 297 EP - 302 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak A1 - Schultze, Joachim W. T1 - Measuring seven parameters by two ISFET modules in a microcell set-up JF - Int. Journal of Computational Engineering Science. 4 (2003), H. 2 Y1 - 2003 SN - 1465-8763 SP - 257 EP - 260 ER - TY - JOUR A1 - Thust, M. A1 - Schöning, Michael Josef A1 - Muchandani, A. A1 - Wang, J. A1 - Arzdorf, M. A1 - Mulchandani, P. A1 - Chen, W. T1 - Feldeffekt-Enzymsensor zur Detektion von Pestiziden JF - Sensoren für zukünftige Hochtechnologien und Neuentwicklungen für die Verfahrenstechnik / 6. Dresdner Sensor-Symposium, 8. - 10. Dezember 2003, Dresden. Jörg Peter Baselt; Gerald Gerlach (Hg.) Y1 - 2003 SN - 3-935712-92-8 SP - 125 EP - 128 PB - w.e.b.-Univ.-Verl. CY - Dresden ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - "High-order” hybrid FET module for (bio)chemical and physical sensing JF - Integrated analytical systems / ed. by Salvador Alegret Y1 - 2003 SN - 0-444-51037-0 SP - 587 EP - 623 PB - Elsevier CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Keusgen, M. A1 - Jünger, M. A1 - Knobbe, D.-T. A1 - Kloock, Joachim P. A1 - Schöning, Michael Josef T1 - Entwicklung eines potentiometrischen Cyanid-Biosensors auf der Basis von EIS-Strukturen JF - Sensoren für zukünftige Hochtechnologien und Neuentwicklungen für die Verfahrenstechnik / 6. Dresdner Sensor-Symposium, 8. - 10. Dezember 2003, Dresden. Jörg Peter Baselt; Gerald Gerlach (Hg.) Y1 - 2003 SN - 3-935712-92-8 SP - 235 EP - 238 PB - w.e.b.-Univ.-Verl. CY - Dresden ER - TY - JOUR A1 - Sponagel, Stefan A1 - Unger, J. A1 - Spies, K. H. T1 - Härtebegriff im Zusammenhang mit Vernetzung, Bruchdehnung und Dauerfestigkeit eines Elastomers JF - Kautschuk Gummi Kunststoffe. 56 (2003), H. 11 Y1 - 2003 SN - 0948-3276 SP - 608 EP - 613 ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Probabilistic limit and shakedown problems JF - Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M; Heitzer, M. Y1 - 2003 SN - 3-00-010001-6 SP - 217 EP - 268 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, M. T1 - Basis reduction technique for limit and shakedown problems T2 - Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M.; Heitzer, M. Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0001-2018112115 SN - 3-00-010001-6 SP - 1 EP - 55 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. A1 - Reiners, H. A1 - Schubert, F. T1 - Shakedown and ratchetting under tension–torsion loadings: analysis and experiments JF - Nuclear Engineering and Design. 225 (2003), H. 1 Y1 - 2003 SN - 0029-5493 SP - 11 EP - 26 ER - TY - JOUR A1 - Staat, Manfred A1 - Schwartz, M. A1 - Lang, H. A1 - Wirtz, K. A1 - Heitzer, M. T1 - Design by Analysis of Pressure Components by non-linear Optimization JF - The 10th International Conference on Pressure Vessel Technology, July 7-10, 2003, Vienna, Austria, Proceedings ICPVT-10 / Zeman, J. L. [ed] Y1 - 2003 SN - 3950152814 SP - 59 EP - 65 PB - ÖGS, Österreichische Gesellschaft für Schweißtechnik CY - Wien ER - TY - JOUR A1 - Schöning, Michael Josef T1 - Silicon-based biochemical sensors JF - CNI - The Center of Nanoelectronic Systems for Information Technology Y1 - 2003 SP - 165 EP - 170 PB - Foschungszentrum Jülich ER - TY - CHAP A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül A1 - Nojima, H. A1 - Artmann, Gerhard T1 - Some peculiarities of application of cluster ions generated by plasma in respect of indoor air purification :[abstract] N2 - Recently, the SHARP Corporation, Japan, has developed the world’s first "Plasma Cluster Ions (PCI)" air purification technology using plasma discharge to generate cluster ions. The new plasma cluster device releases positive and negative ions into the air, which are able to decompose and deactivate harmful airborne substances by chemical reactions. Because cluster ions consist of positive and negative ions that normally exist in the natural world, they are completely harmless and safe to humans. The amount of ozone generated by cluster ions is less than 0.01 ppm, which is significantly less than the 0.05-ppm standard for industrial operations and consumer electronics. This amount, thus, has no harming effects whatsoever on the human body. But particular properties and chemical processes in PCI treatment are still under study. It has been shown that PCI in most cases show strongly pronounced irreversible killing effects in respect of airborne microflora due to free-radical induced reactions and can be considered as a potent technology to disinfect both home, medical and industrial appliances. KW - Clusterion KW - Raumluft KW - Luftreiniger KW - Plasmacluster ion technology KW - Air purification Y1 - 2003 ER - TY - CHAP A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül A1 - Nojima, H. A1 - Artmann, Gerhard T1 - Effects of plasma generated ions on bacteria : [poster] N2 - Summary and Conclusions PCIs were clearly effective in terms of their antibacterial effects with the strains tested. This efficacy increased with the time the bacteries were exposed to PCIs. The bactericidal action has proved to be irreversible. PCIs were significantly less effective in shadowed areas. PCI exposure caused multiple protein damages as observed in SDS PAGE studies. There was no single but multiple molecular mechanism causing the bacterial death. KW - Clusterion KW - Bakterien KW - plasma generated ions Y1 - 2003 ER - TY - CHAP A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard A1 - Nojima, H. T1 - Plasma cluster ions (PCI) influence on microbial cells viability : [abstract] N2 - Recently, SHARP corporation has developed the world’s first “Plasma Cluster Ions (PCI)” air purification technology, which uses plasma discharge to generate cluster ions. The new plasma cluster device releases into the air positive and negative ions, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. A lot of phenomenological tests of the PCI air purification technology on microbial cells have been conducted. And, in most cases, it has been shown that PCI demonstrate strongly pronounced killing effect. Although, the particular mechanisms of PCI action are still not evident. We studied variations in resistance to PCI among gram-positive airborne microorganisms, as well as some dose-dependent, spatial, cultural and biochemical properties of PCI action in respect of Staphylococcus spp, Enterococcus spp, Micrococcus spp. KW - Clusterion KW - Raumluft KW - Luftreiniger KW - Plasmacluster ion technology KW - Air purification Y1 - 2003 ER - TY - CHAP A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül A1 - Nojima, H. A1 - Artmann, Gerhard T1 - Plasma-generated cluster ions' effects on indoor microflora : [abstract] N2 - Recently, SHARP corporation has developed the world’s first "Plasma Cluster Ions® (PCI)" air purification technology, which uses plasma discharge to generate cluster ions. The new Plasma Cluster Device releases positive and negative ions into the air, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. In the past, phenomenological tests on the efficacy of the PCI air purification technology on microbial cells have been conducted. In most cases, it has been shown that PCI demonstrated strongly pronounced killing effects on microorganisms. However, the particular mechanisms of PCI action still have to be uncovered. KW - Clusterion KW - Raumluft KW - Luftreiniger KW - Plasmacluster ion technology KW - Air purification Y1 - 2003 ER -