TY - CHAP A1 - Rendon, Carlos A1 - Dieckmann, Simon A1 - Weidle, Mathias A1 - Dersch, Jürgen A1 - Teixeira Boura, Cristiano José A1 - Polklas, Thomas A1 - Kuschel, Marcus A1 - Herrmann, Ulf T1 - Retrofitting of existing parabolic trough collector power plants with molten salt tower systems T2 - AIP Conference Proceedings Y1 - 2018 U6 - http://dx.doi.org/10.1063/1.5067030 VL - 2033 IS - 1 SP - 030014-1 EP - 030014-8 ER - TY - CHAP A1 - Herrmann, Ulf A1 - Graeter, F. A1 - Nava, P. ED - Ramos, C. T1 - Performance of the SKAL-ET Collector Loop at KJC Operating Company T2 - 12th International Symposium Solar Power and Chemical Energy Systems, October 6-8, 2004, Oaxaca Mexico ; SolarPACES International Symposium, 12 Y1 - 2004 SN - 968-6114-18-1 PB - Instituto de Investigaciones Electricas CY - [s.l.] ER - TY - CHAP A1 - Anthrakidis, Anette A1 - Herrmann, Ulf A1 - Mirza, M. F. A1 - Schorn, Christian A1 - Schwarzer, Klemens A1 - Wedding, Philipp A1 - Weis, Fabian T1 - Parabolrinnenentwicklung und Qualifizierung am Solar-Institut Jülich T2 - Thermische Solarenergie : 24. Symposium ; 7. bis 9. Mai 2014, Kloster Banz, Bad Staffelstein Y1 - 2014 SN - 978-3-943891-35-5 SP - 242 EP - 243 PB - OTTI CY - Regensburg ER - TY - CHAP A1 - Kelly, Bruce A1 - Herrmann, Ulf A1 - Hale, M.-J. T1 - Optimization Studies for Integrated Solar Combined Cycle Systems T2 - Solar engineering 2001 : proceedings of the International Solar Energy Conference ; presented at the 2001 International Solar Energy Conference, a part of Forum 2001 - Solar energy: the power to choose, April 21 - 25, 2001, Washington, D.C. Y1 - 2001 SN - 0-7918-1670-2 N1 - International Solar Energy Conference SP - 393 EP - 398 PB - ASME CY - New York, NY ER - TY - CHAP A1 - Sattler, Johannes, Christoph A1 - Caminos, Ricardo Alexander Chico A1 - Ürlings, Nicolas A1 - Dutta, Siddharth A1 - Ruiz, Victor A1 - Kalogirou, Soteris A1 - Ktistis, Panayiotis A1 - Agathokleous, Rafaela A1 - Jung, Christian A1 - Alexopoulos, Spiros A1 - Atti, Vikrama Nagababu A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Operational experience and behaviour of a parabolic trough collector system with concrete thermal energy storage for process steam generation in Cyprus T2 - AIP Conference Proceedings Y1 - 2020 U6 - http://dx.doi.org/10.1063/5.0029278 IS - 2303 SP - 140004-1 EP - 140004-10 ER - TY - CHAP A1 - Duran Paredes, Ludwin A1 - Mottaghy, Darius A1 - Herrmann, Ulf A1 - Groß, Rolf Fritz T1 - Online ground temperature and soil moisture monitoring of a shallow geothermal system with non-conventional components T2 - EGU General Assembly 2020 N2 - We present first results from a newly developed monitoring station for a closed loop geothermal heat pump test installation at our campus, consisting of helix coils and plate heat exchangers, as well as an ice-store system. There are more than 40 temperature sensors and several soil moisture content sensors distributed around the system, allowing a detailed monitoring under different operating conditions.In the view of the modern development of renewable energies along with the newly concepts known as Internet of Things and Industry 4.0 (high-tech strategy from the German government), we created a user-friendly web application, which will connect the things (sensors) with the open network (www). Besides other advantages, this allows a continuous remote monitoring of the data from the numerous sensors at an arbitrary sampling rate.Based on the recorded data, we will also present first results from numerical simulations, taking into account all relevant heat transport processes.The aim is to improve the understanding of these processes and their influence on the thermal behavior of shallow geothermal systems in the unsaturated zone. This will in turn facilitate the prediction of the performance of these systems and therefore yield an improvement in their dimensioning when designing a specific shallow geothermal installation. Y1 - 2020 N1 - Online 4–8 May 2020 [Session ERE2.8] EGU2020-19052 ER - TY - CHAP A1 - Mahdi, Zahra A1 - Rendón, Carlos A1 - Schwager, Christian A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Novel concept for indirect solar-heated methane reforming T2 - AIP Conference Proceedings Y1 - 2019 U6 - http://dx.doi.org/10.1063/1.5117694 SN - 0094-243X VL - 2126 SP - 180014-1 EP - 180014-7 PB - AIP Publishing CY - Melville, NY ER - TY - CHAP A1 - Blake, D. A1 - Moens, L. A1 - Hale, M.-J. A1 - Price, Henry A1 - Keaney, David W. A1 - Herrmann, Ulf ED - Steinfeld, Aldo T1 - New heat transfer and storage fluids for parabolic trough solar thermal electric plants T2 - Proceedings of the 11th SolarPACES International Symposium on Concentrated Solar Power and Chemical Energy Technologies : September 4 - 6, 2002, Zurich, Switzerland / Paul Scherrer Institut, PSI; ETH, Eidgenössische Technische Hochschule Zürich Y1 - 2002 SN - 3-9521409-3-7 SP - 63 EP - 66 PB - Paul Scherrer Inst. CY - Villingen ER - TY - CHAP A1 - Zahra, Mahdi A1 - Phani Srujan, Merige A1 - Caminos, Ricardo Alexander Chico A1 - Schmitz, Pascal A1 - Herrmann, Ulf A1 - Teixeira Boura, Cristiano José A1 - Schmitz, Mark A1 - Gielen, Hans A1 - Gedle, Yibekal A1 - Dersch, Jürgen T1 - Modeling the thermal behavior of solar salt in electrical resistance heaters for the application in PV-CSP hybrid power plants T2 - SOLARPACES 2020 N2 - Concentrated Solar Power (CSP) systems are able to store energy cost-effectively in their integrated thermal energy storage (TES). By intelligently combining Photovoltaics (PV) systems with CSP, a further cost reduction of solar power plants is expected, as well as an increase in dispatchability and flexibility of power generation. PV-powered Resistance Heaters (RH) can be deployed to raise the temperature of the molten salt hot storage from 385 °C up to 565 °C in a Parabolic Trough Collector (PTC) plant. To avoid freezing and decomposition of molten salt, the temperature distribution in the electrical resistance heater is investigated in the present study. For this purpose, a RH has been modeled and CFD simulations have been performed. The simulation results show that the hottest regions occur on the electric rod surface behind the last baffle. A technical optimization was performed by adjusting three parameters: Shell-baffle clearance, electric rod-baffle clearance and number of baffles. After the technical optimization was carried out, the temperature difference between the maximum temperature and the average outlet temperature of the salt is within the acceptable limits, thus critical salt decomposition has been avoided. Additionally, the CFD simulations results were analyzed and compared with results obtained with a one-dimensional model in Modelica. KW - Solar thermal technologies KW - Hybrid energy system KW - Concentrated solar power KW - Energy storage KW - Photovoltaics Y1 - 2022 SN - 978-0-7354-4195-8 U6 - http://dx.doi.org/10.1063/5.0086268 SN - 1551-7616 (online) SN - 0094-243X (print) N1 - 26th International Conference on Concentrating Solar Power and Chemical Energy Systems 28 September–2 October 2020 Freiburg, Germany IS - 2445 / 1 PB - AIP conference proceedings / American Institute of Physics CY - Melville, NY ER - TY - CHAP A1 - Rendon, Carlos A1 - Schwager, Christian A1 - Ghiasi, Mona A1 - Schmitz, Pascal A1 - Bohang, Fakhri A1 - Caminos, Ricardo Alexander Chico A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Modeling and upscaling of a pilot bayonettube reactor for indirect solar mixed methane reforming T2 - AIP Conference Proceedings Y1 - 2020 U6 - http://dx.doi.org/10.1063/5.0029974 IS - 2303 SP - 170012-1 EP - 170012-9 ER -