TY - JOUR A1 - Turek, Monik A1 - Heiden, Wolfgang A1 - Guo, Sharon A1 - Riesen, Alfred A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Krüger, Peter A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Simultaneous detection of cyanide and heavy metals for environmental analysis by means of µISEs JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 817 EP - 823 ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 7 ER - TY - JOUR A1 - Aggeloussis, Nickos A1 - Giannakou, Erasmia A1 - Albracht, Kirsten A1 - Arampatzis, Adamantios T1 - Reproducibility of fascicle length and pennation angle of gastrocnemius medialis in human gait in vivo JF - Gait and Posture N2 - The purpose of the current study was to examine the reproducibility of fascicle length and pennation angle of gastrocnemius medialis while human walking. To the best of our knowledge, this is the first study of the reproducibility of fascicle length and pennation angle of gastrocnemius medialis in vivo during human gait. Twelve males performed 10 gait trials on a treadmill, in 2 separate days. B-mode ultrasonography, with the ultrasound probe firmly adjusted in the transverse and frontal planes using a special cast, was used to measure the fascicle length and the pennation angle of the gastrocnemius medialis (GM). A Vicon 624 system with three cameras operating at 120 Hz was also used to record the ankle and knee joint angles. The results showed that measurements of fascicle length and pennation angle showed high reproducibility during the gait cycle, both within the same day and between different days. Moreover, the root mean square differences between the repeated waveforms of both variables were very small, compared with their ranges (fascicle length: RMS = ∼3 mm, range: 38–63 mm; pennation angle: RMS = ∼1.5°, range: 22–32°). However, their reproducibility was lower compared to the joint angles. It was found that representative data have to be derived by a wide number of gait trials (fascicle length ∼six trials, pennation angle more than 10 trials), to assure the reliability of the fascicle length and pennation angle in human gait. Y1 - 2010 U6 - http://dx.doi.org/10.1016/j.gaitpost.2009.08.249 SN - 0966-6362 VL - 31 IS - 1 SP - 73 EP - 77 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Friedrich, Peter A1 - Rysstad, G. A1 - Berger, J. A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Realization of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference SP - 264 EP - 267 ER - TY - JOUR A1 - Kirchner, Patrick A1 - Spelthahn, H. A1 - Schöning, Michael Josef A1 - Henkel, H. A1 - Schneider, A. A1 - Friedrich, P. A1 - Kolstad, J. A1 - Berger, J. T1 - Realisierung eines Polyimid-basierten kalorimetrischen Gassensors zur Inline-Überwachung der H2O2-Konzentration in aseptischen Abfüllanlagen JF - Sensoren und Messsysteme 2010 [Elektronische Ressource] : Vorträge der 15. ITG/GMA-Fachtagung vom 18. bis 19. Mai 2010 in Nürnberg / Informationstechnische Gesellschaft im VDE (ITG); VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA) Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Fachtagung Sensoren und Messsysteme 15, 2010, Nürnberg ; Gesellschaft Mess- und Automatisierungstechnik SP - 607 EP - 612 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Bohrn, U. A1 - Stütz, E. A1 - Fleischer, M. A1 - Schöning, Michael Josef T1 - Real-time detection of CO by eukaryotic cells JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference SP - 17 EP - 20 ER - TY - JOUR A1 - Wiescher, A. A1 - Kotliar, Konstantin A1 - Neuhann, T. A1 - Lanzl, Ines M. T1 - Rasch progrediente Visusminderung beider Augen bei einem jungen Patienten JF - Der Ophthalmologe N2 - Ein 34-jähriger männlicher Patient stellte sich zur Abklärung einer seit dem 9. Lebensjahr bestehenden und im letzten Jahr rasch progredienten Visusminderung beider Augen bei uns vor. Er beschrieb eine subjektiv zunehmende, im Spiegel für ihn selbst sichtbare, weißliche Trübung in der Pupille beidseits und eine starke Blendempfindlichkeit. Nebenbefundlich gab er rezidivierende Konjunktivitiden und morgens verklebte Lider an. Eine Allergie auf Gräserpollen und eine Unverträglichkeit auf Alkohol sowie mehrere Lebensmittel seien ebenfalls bekannt. Zusätzlich leidet der Patient an stark ausgeprägtem atopischem Ekzem. Dieses wurde nie systemisch, sondern nur bei Bedarf mit kortisonhaltiger Salbe therapiert. Y1 - 2010 U6 - http://dx.doi.org/10.1007/s00347-007-1586-x SN - 1433-0423 VL - 105 IS - 4 SP - 389 EP - 392 PB - Springer CY - Berlin ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Peper, Andreas A1 - Bierbaum, Stefanie A1 - Albracht, Kirsten T1 - Plasticity of human Achilles tendon mechanical and morphological properties in response to cyclic strain JF - Journal of Biomechanics N2 - The purpose of the current study in combination with our previous published data (Arampatzis et al., 2007) was to examine the effects of a controlled modulation of strain magnitude and strain frequency applied to the Achilles tendon on the plasticity of tendon mechanical and morphological properties. Eleven male adults (23.9±2.2 yr) participated in the study. The participants exercised one leg at low magnitude tendon strain (2.97±0.47%), and the other leg at high tendon strain magnitude (4.72±1.08%) of similar frequency (0.5 Hz, 1 s loading, 1 s relaxation) and exercise volume (integral of the plantar flexion moment over time) for 14 weeks, 4 days per week, 5 sets per session. The exercise volume was similar to the intervention of our earlier study (0.17 Hz frequency; 3 s loading, 3 s relaxation) allowing a direct comparison of the results. Before and after the intervention ankle joint moment has been measured by a dynamometer, tendon–aponeurosis elongation by ultrasound and cross-sectional area of the Achilles tendon by magnet resonance images (MRI). We found a decrease in strain at a given tendon force, an increase in tendon–aponeurosis stiffness and tendon elastic modulus of the Achilles tendon only in the leg exercised at high strain magnitude. The cross-sectional area (CSA) of the Achilles tendon did not show any statistically significant (P>0.05) differences to the pre-exercise values in both legs. The results indicate a superior improvement in tendon properties (stiffness, elastic modulus and CSA) at the low frequency (0.17 Hz) compared to the high strain frequency (0.5 Hz) protocol. These findings provide evidence that the strain magnitude applied to the Achilles tendon should exceed the value, which occurs during habitual activities to trigger adaptational effects and that higher tendon strain duration per contraction leads to superior tendon adaptational responses. Y1 - 2010 U6 - http://dx.doi.org/10.1016/j.jbiomech.2010.08.014 SN - 0021-9290 VL - 43 IS - 16 SP - 3073 EP - 3079 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Buniatyan, Vahe V. A1 - Abouzar, Maryam H. A1 - Martirosyan, Norayr W. A1 - Schubert, Jürgen A1 - Gevorgian, Spartak A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - pH-sensitive properties of barium strontium titanate (BST) thin films prepared by pulsed laser deposition technique JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 824 EP - 830 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Probst, M. A1 - Mai, A. A1 - Behr, M. A1 - Tran, L. A1 - Vonderstein, K. A1 - Mottaghy, K. T1 - Numerical Prediction of Blood Damage in Biomedical Devices Y1 - 2010 N1 - Posterpresentation ; Biomedica Congress, Aachen, March 17-18, 2010 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Mai, A. A1 - Waluga, C. A1 - Bergmann, B. A1 - Tran, L. A1 - Vonderstein, K. A1 - Behr, M. A1 - Mottaghy, K. T1 - Numerical Modeling of Flow-Related Thrombus Formation under Physiological and Non-Physiological Flow Conditions JF - Acta Physiologica Y1 - 2010 SN - 1748-1716 N1 - Joint Congress of the Scandinavian and German Physiological Societies, Copenhagen, Denmark, March 27-30, 2010 VL - 198 IS - Supplement 677 SP - 185 ER - TY - JOUR A1 - Grajewski, Matthias A1 - Köster, Michael A1 - Turek, Stefam T1 - Numerical analysis and implementational aspects of a new multilevel grid deformation method JF - Applied Numerical Mathematics N2 - Recently, we introduced and mathematically analysed a new method for grid deformation (Grajewski et al., 2009) [15] we call basic deformation method (BDM) here. It generalises the method proposed by Liao et al. (Bochev et al., 1996; Cai et al., 2004; Liao and Anderson, 1992) [4], [6], [20]. In this article, we employ the BDM as core of a new multilevel deformation method (MDM) which leads to vast improvements regarding robustness, accuracy and speed. We achieve this by splitting up the deformation process in a sequence of easier subproblems and by exploiting grid hierarchy. Being of optimal asymptotic complexity, we experience speed-ups up to a factor of 15 in our test cases compared to the BDM. This gives our MDM the potential for tackling large grids and time-dependent problems, where possibly the grid must be dynamically deformed once per time step according to the user's needs. Moreover, we elaborate on implementational aspects, in particular efficient grid searching, which is a key ingredient of the BDM. Y1 - 2010 U6 - http://dx.doi.org/10.1016/j.apnum.2010.03.017 SN - 0168-9274 VL - 60 IS - 8 SP - 767 EP - 781 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Wagner, Torsten A1 - Miyamoto, Ko-ichiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Novel combination of digital light processing (DLP) and light-addressable potentiometric sensors (LAPS) for flexible chemical imaging JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference SP - 520 EP - 523 ER - TY - JOUR A1 - Nam, J. A1 - Arora, D. A1 - Behbahani, Mehdi A1 - Probst, M. A1 - Benkowski, R. A1 - Behr, M. A1 - Pasquali, M. T1 - New computational method in hemolysis analysis for artificial heart pump Y1 - 2010 N1 - Posterpresentation ; American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 ER - TY - JOUR A1 - Werner, Frederik A1 - Spelthahn, H. A1 - Schöning, Michael Josef A1 - Krumbe, C. A1 - Wagner, Torsten A1 - Yoshinobu, T. A1 - Keusgen, M. T1 - Neue Ansteuerungselektronik für LAPS-basierte Biosensoren zur gleichzeitig ortsaufgelösten Messung der pH-Konzentration JF - Sensoren und Messsysteme 2010 [Elektronische Ressource] : Vorträge der 15. ITG/GMA-Fachtagung vom 18. bis 19. Mai 2010 in Nürnberg / Informationstechnische Gesellschaft im VDE (ITG); VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA) Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Fachtagung Sensoren und Messsysteme 15, 2010, Nürnberg ; Gesellschaft Mess- und Automatisierungstechnik SP - 109 EP - 114 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Mai, A. A1 - Bergmann, B. A1 - Waluga, C. A1 - Behr, M. A1 - Tran, L. A1 - Vonderstein, K. A1 - Mottaghy, K. T1 - Modeling and Numerical Simulation of Blood Damage Y1 - 2010 N1 - Posterpresentation ; Umbrella Symposium "Modelling and Simulation in Medicine, Engineering and Sciences", Forschungszentrum Jülich, January 18-20, 2010 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Nam, J. A1 - Waluga, C. A1 - Behr, M. A1 - Pasquali, M. A1 - Mottaghy, K. T1 - Modeling and Numerical Analysis of Platelet Activation, Adhesion and Aggregation in Artificial Organs Y1 - 2010 U6 - http://dx.doi.org/10.1097/01.mat.0000369377.65122.a3 N1 - Posterpresentation American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Kaneko, Kazumi A1 - Matsuo, Akira A1 - Wagner, Torsten A1 - Kanoh, Shin`ichiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Miniaturized chemical imaging sensor system using an OLED display panel JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference SP - 516 EP - 519 ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Nagel, Edgar A1 - Vilser, Walthard A1 - Seidova, Seid-Fatima A1 - Lanzl, Ines T1 - Microstructural alterations of retinal arterial blood column along the vessel axis in systemic hypertension JF - Investigative Ophthalmology & Visual Science, IOVS N2 - Purpose: Image analysis by the retinal vessel analyzer (RVA) observes retinal vessels in their dynamic state online noninvasively along a chosen vessel segment. It has been found that high-frequency diameter changes in the retinal artery blood column along the vessel increase significantly in anamnestically healthy volunteers with increasing age and in patients with glaucoma during vascular dilation. This study was undertaken to investigate whether longitudinal sections of the retinal artery blood column are altered in systemic hypertension. Methods: Retinal arteries of 15 untreated patients with essential arterial hypertension (age, 50.9 ± 11.9 years) and of 15 age-matched anamnestically healthy volunteers were examined by RVA. After baseline assessment, a monochromatic luminance flicker (530–600 nm; 12.5 Hz; 20 s) was applied to evoke retinal vasodilation. Differences in amplitude and frequency of spatial artery blood column diameter change along segments (longitudinal arterial profiles) of 1 mm in length were measured and analyzed using Fourier transformation. Results: In the control group, average reduced power spectra (ARPS) of longitudinal arterial profiles did not differ when arteries changed from constriction to dilation. In the systemic hypertension group, ARPS during constriction, baseline, and restoration were identical and differed from ARPS during dilation (P < 0.05). Longitudinal arterial profiles in both groups showed significant dissimilitude at baseline and restoration (P < 0.05). Conclusions: The retinal artery blood column demonstrates microstructural alterations in systemic hypertension and is less irregular along the vessel axis during vessel dilation. These microstructural changes may be an indication of alterations in vessel wall rigidity, vascular endothelial function, and smooth muscle cells in this disease, leading to impaired perfusion and regulation. Y1 - 2010 U6 - http://dx.doi.org/10.1167/iovs.09-3649 SN - 0146-0404 VL - 51 IS - 4 SP - 2165 EP - 2172 PB - ARVO CY - Rockville, Md. ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Pedraza, A. M. A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Label-free DNA hybridization and denaturation detection by means of field-effect nanoplate SOI capacitors functionalized with gold nanoparticles JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Proc. Eurosensors XXIV, September 5–8, 2010, Linz, Austria SP - 918 EP - 921 ER -