TY - JOUR A1 - Bäcker, Matthias A1 - Kowollik, Silvia A1 - Schnitzler, Thomas A1 - Wang, J. A1 - Poghossian, Arshak A1 - Zang, Werner A1 - Biselli, Manfred A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - Entwicklung eines festkörperbasierten Sensorsystems für die Bioprozessautomatisierung JF - 9. Dresdner Sensor-Symposium : Dresden, 07.-09. Dezember 2009 / Gerlach, Gerald ; Hauptmann, Peter [Hrsg.] Y1 - 2009 SN - 978-3-941298-44-6 N1 - Dresdner Sensor-Symposium ; (9, 2009, Dresden) SP - 197 EP - 200 PB - TUDpress CY - Dresden ER - TY - JOUR A1 - Kirchner, Patrick A1 - Li, B. A1 - Spelthahn, H. A1 - Henkel, H. A1 - Schneider, A. A1 - Kolstad, J. A1 - Friedrich, P. A1 - Schöning, Michael Josef T1 - Realisierung eines miniaturisierten Gassensors in Chiptechnologie basierend auf einer Dünnschicht-Thermosäule zur H2O2-Detektion in aseptischen Abfüllanlagen JF - 9. Dresdner Sensor-Symposium : Dresden, 07.-09. Dezember 2009 / Gerlach, Gerald ; Hauptmann, Peter [Hrsg.] Y1 - 2009 SN - 978-3-941298-44-6 N1 - Dresdner Sensor-Symposium ; (9, 2009, Dresden) SP - 293 EP - 296 PB - TUDpress CY - Dresden ER - TY - JOUR A1 - Reisert, Steffen A1 - Henkel, H. A1 - Schneider, A. A1 - Schäfer, Daniel A1 - Friedrich, P. A1 - Berger, Jörg A1 - Schöning, Michael Josef T1 - Entwicklung eines Handheld-Sensorsystems für die „On-line“-Messung der H2O2-Konzentration in aseptischen Entkeimungsprozessen JF - 9. Dresdner Sensor-Symposium : Dresden, 07.-09. Dezember 2009 / Gerlach, Gerald ; Hauptmann, Peter [Hrsg.] Y1 - 2009 SN - 978-3-941298-44-6 N1 - Dresdner Sensor-Symposium ; (9, 2009, Dresden) SP - 285 EP - 288 PB - TUDpress CY - Dresden ER - TY - JOUR A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Wenmackers, Sylvia A1 - Janssens, Stoffel D. A1 - Haenen, Ken A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Capacitive field-effect (bio-)chemical sensors based on nanocrystalline diamond films JF - MRS Online Proceedings Library N2 - Capacitive field-effect electrolyte-diamond-insulator-semiconductor (EDIS) structures with O-terminated nanocrystalline diamond (NCD) as sensitive gate material have been realized and investigated for the detection of pH, penicillin concentration, and layer-by-layer adsorption of polyelectrolytes. The surface oxidizing procedure of NCD thin films as well as the seeding and NCD growth process on a Si-SiO2 substrate have been improved to provide high pH-sensitive, non-porous thin films without damage of the underlying SiO2 layer and with a high coverage of O-terminated sites. The NCD surface topography, roughness, and coverage of the surface groups have been characterized by SEM, AFM and XPS methods. The EDIS sensors with O-terminated NCD film treated in oxidizing boiling mixture for 45 min show a pH sensitivity of about 50 mV/pH. The pH-sensitive properties of the NCD have been used to develop an EDIS-based penicillin biosensor with high sensitivity (65-70 mV/decade in the concentration range of 0.25-2.5 mM penicillin G) and low detection limit (5 μM). The results of label-free electrical detection of layer-by-layer adsorption of charged polyelectrolytes are presented, too. Y1 - 2010 SN - 1946-4274 VL - 1203 PB - MRS CY - Warrendale ER - TY - JOUR A1 - Beging, Stefan A1 - Mlynek, Daniela A1 - Hataihimakul, Sudkanung A1 - Poghossian, Arshak A1 - Baldsiefen, Gerhard A1 - Busch, Heinz A1 - Laube, Norbert A1 - Kleinen, Lisa A1 - Schöning, Michael Josef T1 - Field-effect calcium sensor for the determination of the risk of urinary stone formation JF - Sensors and Actuators B: Chemical N2 - Urinary stone formation has been evolved to a widespread disease during the last years. The reason for the formation of urinary stones are little crystals, mostly composed of calcium oxalate, which are formed in human kidneys. The early diagnosis of the risk for urinary stone formation of patients can be determined by the “Bonn-Risk-Index” method based on the potentiometric detection of the Ca2+-ion concentration and an optical determination of the triggered crystallisation of calcium oxalate in unprocessed urine. In this work, miniaturised capacitive field-effect EMIS (electrolyte-membrane-insulator-semiconductor) sensors have been developed for the determination of the Ca2+-ion concentration in human native urine. The Ca2+-sensitive EMIS sensors have been systematically characterised by impedance spectroscopy, capacitance–voltage and constant–capacitance method in terms of sensitivity, signal stability and response time in both CaCl2 solutions and in native urine. The obtained results demonstrate the suitability of EMIS sensors for the measurement of the Ca2+-ion concentration in native urine of patients. Y1 - 2010 U6 - https://doi.org/10.1016/j.snb.2008.12.012 SN - 0925-4005 N1 - 22nd International Conference on Eurosensors: Dresden, Germany, 7-10 September 2008 VL - 144 IS - 2 SP - 374 EP - 379 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Reisert, Steffen A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schäfer, Daniel A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Schöning, Michael Josef T1 - Development of a handheld sensor system for the online measurement of hydrogen peroxide in aseptic filling systems JF - Physica Status Solidi (A) N2 - A handheld sensor system for the online measurement of hydrogen peroxide (H2O2) in aseptic sterilisation processes has been developed. It is based on a calorimetric-type gas sensor that consists of a differential set-up of two temperature sensors, of which one is catalytically activated and the second one is passivated and used as reference. The sensor principle relies in detecting a rise in temperature on the active sensor due to the exothermic reaction of H2O2 on the catalytic surface. To characterise the sensor system towards H2O2 sensitivity and other influencing factors, measurements have been carried out both at an experimental set-up and a manufacturer's sterilisation machine. Physical sensor characterisation was done by means of the optical microscopy. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983304 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 913 EP - 918 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Sugawara, Yuri A1 - Kanoh, Shin´ichiro A1 - Yoshinobu, Tatsuo A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Image correction method for the chemical imaging sensor JF - Sensors and Actuators B: Chemical N2 - The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of chemical species. For the practical application of this sensor, artifacts in the chemical images due to defects of the semiconductor substrate and contamination of the sensing surface etc. have been a major problem. An image correction method was developed to eliminate the influence of nonuniformity of individual sensor plate. Y1 - 2010 U6 - https://doi.org/10.1016/j.snb.2008.10.069 SN - 0925-4005 N1 - 22nd International Conference on Eurosensors: Dresden, Germany, 7-10 September 2008 VL - 144 IS - 2 SP - 344 EP - 348 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Siqueira, José R. Jr. A1 - Oliveira, Osvaldo N. Jr. A1 - Moritz, Werner A1 - Schöning, Michael Josef T1 - Capacitive electrolyte-insulator-semiconductor structures functionalised with a polyelectrolyte/enzyme multilayer: New strategy for enhanced field-effect biosensing JF - Physica Status Solidi (A) N2 - A novel strategy for enhanced field-effect biosensing using capacitive electrolyte–insulator–semiconductor (EIS) structures functionalised with pH-responsive weak polyelectrolyte/enzyme or dendrimer/enzyme multilayers is presented. The feasibility of the proposed approach is exemplarily demonstrated by realising a penicillin biosensor based on a capacitive p-Si–SiO2 EIS structure functionalised with a poly(allylamine hydrochloride) (PAH)/penicillinase and a poly(amidoamine) dendrimer/penicillinase multilayer. The developed sensors response to changes in both the local pH value near the gate surface and the charge of macromolecules induced via enzymatic reaction, resulting in a higher sensitivity. For comparison, an EIS penicillin biosensor with adsorptively immobilised penicillinase has been also studied. The highest penicillin sensitivity of 100 mV/dec has been observed for the EIS sensor functionalised with the PAH/penicillinase multilayer. The lower and upper detection limit was around 20 µM and 10 mM, respectively. In addition, an incorporation of enzymes in a multilayer prepared by layer-by-layer technique provides a larger amount of immobilised enzymes per sensor area, reduces enzyme leaching effects and thus, enhances the biosensor lifetime (the loss of penicillin sensitivity after 2 months was 10–12%). Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983317 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 884 EP - 890 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kirchner, Patrick A1 - Ng, Yue Ann A1 - Spelthahn, Heiko A1 - Schneider, Andreas A1 - Henkel, Hartmut A1 - Friedrich, Peter A1 - Kolstad, Jens A1 - Berger, Jörg A1 - Keusgen, Michael T1 - Gas sensor investigation based on a catalytically activated thin-film thermopile for H2O2 detection JF - Physica Status Solidi (A) N2 - In aseptic filling systems, hydrogen peroxide vapour is commonly used for the reduction of microbial contaminations in carton packages. In this process, the germicidal efficiency of the vapour depends especially on the H₂O₂ concentration. To monitor the H₂O₂ concentration, a calorimetric H₂O₂ gas sensor based on a catalytically activated thin-film thermopile is investigated. Two different sensor layouts, namely a circular and a linear form, as well as two various material pairs such as tungsten/nickel and gold/nickel, have been examined for the realization of a thin-film thermopile. Additionally, manganese oxide and palladium particles have been compared as responsive catalysts towards H₂O₂. The thin-film sensors have been investigated at various H₂O₂ concentrations, gas temperatures and flow rates. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983309 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 787 EP - 792 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Buniatyan, Vahe V. A1 - Abouzar, Maryam H. A1 - Martirosyan, Norayr W. A1 - Schubert, Jürgen A1 - Gevorgian, Spartak A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - pH-sensitive properties of barium strontium titanate (BST) thin films prepared by pulsed laser deposition technique JF - Physica Status Solidi (A) N2 - pH-sensitive properties of barium strontium titanate (BST) high-k thin films as alternative gate material for field-effect capacitive (bio-)chemical sensors based on an electrolyte-insulator-semiconductor system have been investigated. The BST films of different compositions (Ba0.31Sr0.69TiO3, Ba0.25Sr0.75TiO3 and Mg-doped Ba0.8Sr0.2Mg0.1Ti0.9O3) were deposited by pulsed laser deposition technique from targets fabricated by self-propagating high-temperature synthesis. The realised sensors have been electrochemically characterised by means of impedance-spectroscopy, capacitance–voltage and constant-capacitance method. The sensors possess a Nernstian-like pH sensitivity in the concentration range between pH 3 and 11 with a response time of 5–10 s. An equivalent circuit model for the BST-based capacitive field-effect sensor is discussed. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983310 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 824 EP - 830 PB - Wiley-VCH CY - Berlin ER -