TY - BOOK A1 - Wosnitza, Franz A1 - Hilgers, Hans Gerd T1 - Energieeffizienz und Energiemanagement : ein Überblick heutiger Möglichkeiten und Notwendigkeiten Y1 - 2012 SN - 978-3-8348-1941-3 N1 - eISBN 978-3-8348-8671-2 PB - Springer Spektrum CY - Wiesbaden ER - TY - BOOK A1 - Wosnitza, Franz A1 - Hilgers, Hans Gerd T1 - Energieeffizienz und Energiemanagement : Ein Überblick heutiger Möglichkeiten und Notwendigkeiten Y1 - 2012 SN - 978-3-8348-8671-2 PB - Vieweg + Teubner CY - Wiesbaden ER - TY - JOUR A1 - Grande, Marion A1 - Meffert, Elisabeth A1 - Schoenberger, Eva A1 - Jung, Stefanie A1 - Frauenrath, Tobias A1 - Huber, Walter A1 - Hussmann, Katja A1 - Moormann, Mareike A1 - Heim, Stefan T1 - From a concept to a word in a syntactically complete sentence: An fMRI study on spontaneous language production in an overt picture description task JF - NeuroImage N2 - Spontaneous language has rarely been subjected to neuroimaging studies. This study therefore introduces a newly developed method for the analysis of linguistic phenomena observed in continuous language production during fMRI. Most neuroimaging studies investigating language have so far focussed on single word or — to a smaller extent — sentence processing, mostly due to methodological considerations. Natural language production, however, is far more than the mere combination of words to larger units. Therefore, the present study aimed at relating brain activation to linguistic phenomena like word-finding difficulties or syntactic completeness in a continuous language fMRI paradigm. A picture description task with special constraints was used to provoke hesitation phenomena and speech errors. The transcribed speech sample was segmented into events of one second and each event was assigned to one category of a complex schema especially developed for this purpose. The main results were: conceptual planning engages bilateral activation of the precuneus. Successful lexical retrieval is accompanied – particularly in comparison to unsolved word-finding difficulties – by the left middle and superior temporal gyrus. Syntactic completeness is reflected in activation of the left inferior frontal gyrus (IFG) (area 44). In sum, the method has proven to be useful for investigating the neural correlates of lexical and syntactic phenomena in an overt picture description task. This opens up new prospects for the analysis of spontaneous language production during fMRI. Y1 - 2012 U6 - https://doi.org/10.1016/j.neuroimage.2012.03.087 SN - 1522-2586 VL - 61 IS - 3 SP - 702 EP - 714 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Ritz, Thomas A1 - Terhaar, Kristin A1 - Wallenborn, Ramona ED - Reiterer, Harald T1 - HMI für eCarSharing : ein Baustein für nachhaltige Mobilität T2 - Mensch & Computer 2012 - Workshopband : 12. Fachübergreifende Konferenz für interaktive und kooperative Medien ; interaktiv informiert - allgegenwärtig und allumfassend!? Y1 - 2012 SN - 978-3-486-71990-1 (Print) SN - 978-3-486-71991-8 (E-Book) U6 - https://doi.org/10.1524/9783486719918.341 N1 - Workshop Automotive HMI SP - 381 EP - 388 PB - Oldenbourg CY - München ER - TY - JOUR A1 - Kobus, Thiele A1 - Bitz, Andreas A1 - Uden, Mark J. van A1 - Lagemaat, Miram W. A1 - Rothgang, Eva A1 - Orzada, Stephan A1 - Heerschap, Arend A1 - Scheenen, Tom W. J. T1 - In vivo 31P MR spectroscopic imaging of the human prostate at 7 T: safety and feasibility JF - Magnetic Resonance in Medicine N2 - 31P MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D 31P MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a 31P endorectal coil was developed and combined with an eight-channel 1H body-array coil to relate metabolic information to anatomical location. An extensive safety validation was performed to evaluate the specific absorption rate, the radiofrequency field distribution, and the temperature distribution of both coils. This validation consisted of detailed Finite Integration Technique simulations, confirmed by MR thermometry and Burn:x-wiley:07403194:media:MRM24175:tex2gif-stack-1 measurements in a phantom and in vivo temperature measurements. The safety studies demonstrated that the presence of the 31P endorectal coil had no influence on the specific absorption rate levels and temperature distribution of the external eight-channel 1H array coil. To stay within a 10 g averaged local specific absorption rate of 10 W/kg, a maximum time-averaged input power of 33 W for the 1H array coil was allowed. For transmitting with the 31P endorectal coil, our safety limit of less than 1°C temperature increase in vivo during a 15-min MR spectroscopic imaging experiment was reached at a time-averaged input power of 1.9 W. With this power setting, a second in vivo measurement was performed on a healthy volunteer. Using adiabatic excitation, 3D 31P MR spectroscopic imaging produced spectra from the entire prostate in 18 min with a spatial resolution of 4 cm3. The spectral resolution enabled the separate detection of phosphocholine, phosphoethanolamine, inorganic phosphate, and other metabolites that could play an important role in the characterization of prostate cancer. Y1 - 2012 U6 - https://doi.org/10.1002/mrm.24175 SN - 1522-2594 VL - 68 IS - 6 SP - 1683 EP - 1695 PB - Wiley-Liss CY - New York ER - TY - CHAP A1 - Nötzold, K. A1 - Uphues, A. A1 - Wegener, R. A1 - Soter, S. A1 - Fink, K. A1 - Bragard, Michael A1 - Griessel, R. T1 - Inverter based test setup for LVRT verification of a full-scale 2 MW wind power converter T2 - EPE Joint Wind Energy and T&D Chapters Seminar : 28th and 29th of June 2012, in the Utzon Centre, Aalborg, Denmark ; papers, posters, presentations. - Session 2: Grid connection, compliance Y1 - 2012 PB - EPE Association CY - Brussels ER - TY - GEN A1 - Frauenrath, Tobias A1 - Pfeiffer, Harald A1 - Hezel, Fabian A1 - Dieringer, Matthias A. A1 - Winter, Lukas A1 - Gräßl, Andreas A1 - Santoro, Davide A1 - Özerdem, Celal A1 - Renz, Wolfgang A1 - Greiser, Andreas A1 - Niendorf, Thoralf T1 - Lessons learned from cardiac MRI at 7.0 T: LV function assessment at 3.0 T using local multi-channel transceiver coil arrays T2 - 2012 ISMRM Annual Meeting Proceedings N2 - Cardiac MR (CMR) is of proven clinical value but also an area of vigorous ongoing research since image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Recent developments of CMR at 7.0 T have been driven by pioneering explorations into novel multichannel transmit and receive coil array technology to tackle the challenges B1+-field inhomogeneities, to offset specific-absorption rate (SAR) constraints and to reduce banding artifacts in SSFP imaging. For this study, recognition of the benefits and performance of local surface Tx/Rx-array structures recently established at 7.0 T inspired migration to 3.0 T, where RF inhomogeneities and SAR limitations encountered in routine clinical CMR, though somewhat reduced versus the 7.0 T situation, remain significant. For all these reasons, this study was designed to build and examine the feasibility of a local four channel Tx/Rx cardiac coil array for anatomical and functional cardiac imaging at 3.0 T. For comparison, a homebuilt 4 channel Rx cardiac coil array exhibiting the same geometry as the Tx/Rx coil and a Rx surface coil array were used. Y1 - 2012 SN - 1545-4428 N1 - ISMRM 20th Annual Meeting & Exhibition, 5-11 May 2012, Melbourne, Australia ER - TY - PAT A1 - Frauenrath, Tobias A1 - Niendorf, Thoralf T1 - MRT-Vorrichtung und Verfahren zum Betreiben einer MRT-Vorrichtung T1 - Magnetic resonance tomography (MRT) apparatus and method of operating a magnetic resonance (MR) apparatus T1 - Appareil de tomographie par résonance magnétique et procédé de fonctionnement d'un appareil à résonance magnétique N2 - A magnetic resonance tomography (MRT) apparatus (1) for the examination of a body (14) comprises parameter acquisition devices (13) for the acquisition of cardiovascular parameters of the body (14) and a control device (15) in communication with the parameter acquisition devices (13) for synchronizing the imaging, wherein the control device (15) is adapted to analyse the data of at least two parameter acquisition devices (13) and to output a control signal based on the analysis. Y1 - 2012 ER - TY - CHAP A1 - Hüning, Felix ED - Schmitz, Günter T1 - PowerMOSFETs für Elektromotoren im Automobil : Vom Fensterheber zum EPS T2 - Elektronik im Kraftfahrzeug : Innovationen bei Systemen und Komponenten ; mit 7 Tabellen Y1 - 2012 SN - 978-3-8169-3110-2 N1 - Haus der Technik Fachbuchreihe ; 123 SP - 71 EP - 81 PB - Expert Verlag CY - Renningen ER - TY - CHAP A1 - Engels, Elmar A1 - Schnabel, Holger T1 - Rapid-control-prototyping of industrial drives for the sercos automation bus T2 - 13th International Workshop on Mechatronics (MECATRONICS), 2012 9th France-Japan & 7th Europe-Asia Congress on and Research and Education in Mechatronics (REM) N2 - This article describes the functionality of a MATLAB® library that can be used to develop motion-logic applications in MATLAB programming language for industrial drive and control systems using the well known sercos automation bus. Therewith MATLAB's functionality is extended to designing automation applications from single axis machines up to multi-kinematic robots. KW - MATLAB , MLPI , Motion control , Open Core , industrial drives , rapid control prototypin , sercos automation bus Y1 - 2012 UR - http://dx.doi.org/10.1109/MECATRONICS.2012.6451005 SN - 978-1-4673-4771-6 SP - 177 EP - 181 ER -