TY - CHAP A1 - Kirsch, Ansgar T1 - Numerical investigation of the face stability of shallow tunnels in sand T2 - Numerical methods in geotechnical engineering : (NUMGE 2010) : proceedings of the seventh European Conference on Numerical Methods in Geotechnical Engineering, Trondheim, Norway, 2 - 4 June 2010 / ed. by Thomas Benz ... Y1 - 2010 SN - 978-0-415-59239-0 SP - 779 EP - 784 PB - Taylor and Francis CY - London ER - TY - JOUR A1 - Kirsch, Ansgar T1 - Experimental investigation of the face stability of shallow tunnels in sand JF - Acta Geotechnica N2 - Various models have been proposed for the prediction of the necessary support pressure at the face of a shallow tunnel. To assess their quality, the collapse of a tunnel face was modelled with small-scale model tests at single gravity. The development of the failure mechanism and the support force at the face in dry sand were investigated. The observed displacement patterns show a negligible influence of overburden on the extent and evolution of the failure zone. The latter is significantly influenced, though, by the initial density of the sand: in dense sand a chimney-wedge-type collapse mechanism developed, which propagated towards the soil surface. Initially, loose sand did not show any discrete collapse mechanism. The necessary support force was neither influenced by the overburden nor the initial density. A comparison with quantitative predictions by several theoretical models showed that the measured necessary support pressure is overestimated by most of the models. Those by Vermeer/Ruse and Léca/Dormieux showed the best agreement to the measurements. Y1 - 2010 U6 - https://doi.org/10.1007/s11440-010-0110-7 SN - 1861-1125 VL - 5 IS - 1 SP - 43 EP - 62 PB - Springer CY - Berlin ER - TY - CHAP A1 - Kirchner, Patrick A1 - Spelthahn, Heiko A1 - Schöning, Michael Josef A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Friedrich, Peter A1 - Kolstad, Jens A1 - Berger, Jörg T1 - Realisierung eines Polyimid-basierten kalorimetrischen Gassensors zur Inline-Überwachung der H2O2-Konzentration in aseptischen Abfüllsystemen T2 - Tagungsband: Sensoren und Messsysteme 2010 N2 - In aseptischen Abfüllsystemen wird Wasserstoffperoxid in der Gasphase aufgrund der stark oxidativen Wirkung zur Packstoffentkeimung eingesetzt. Dabei wird die Effizienz der Entkeimung im Wesentlichen von der vorliegenden H2O2-Konzentration im Packstoff bestimmt. Zur Inline-Überwachung der H2O2-Konzentration wurde ein kalorimetrischer Gassensor auf Basis einer flexiblen Polyimidfolie aus temperatursensitiven Dünnschicht-Widerständen und Mangan(IV)-oxid als katalytische Transducerschicht realisiert. Der Sensor weist ein lineares Ansprechverhalten mit einer Sensitivität von 7,15 °C/Vol.-% in einem H2O2-Konzentrationsbereich von 0 bis 8 Vol.-% auf. Weiterhin wurde zur Auslesung des Sensorsignals eine RFID-Elektronik, bestehend aus einem Sensor-Tag und einer Sende-/Empfangseinheit ausgelegt, sowie eine Abfolge des Messzyklus aufgestellt. Im weiteren Verlauf soll der kalorimetrische Gassensor mit der RFID-Elektronik gekoppelt und in eine Testverpackung zur Inline-Überwachung der H2O2-Konzentration in aseptischen Abfüllsystemen implementiert werden. Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Sensoren und Messsysteme 2010 - 15. ITG/GMA-Fachtagung, 18.05.2010 - 19.05.2010 in Nürnberg SP - 607 EP - 612 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Friedrich, Peter A1 - Rysstad, Gunnar A1 - Berger, Jörg A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Realization of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry JF - Procedia Engineering N2 - A calorimetric gas sensor is presented for the monitoring of gas-phase H2O2 at elevated temperature during sterilization processes in aseptic food industry. The sensor consists of two temperature-sensitive thin-film resistances built up on a polyimide foil with a thickness of 25 μm, which are passivated with a layer of SU-8 photo resist and catalytically activated with manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilizes the elevated temperature of an evaporated H2O2 aerosol. In an experimental set-up, the sensor has shown a sensitivity of 4.78 °C/(%v/v) in a H2O2 concentration range of 0 to 10% v/v at an evaporation temperature of 240 ∘C. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied evaporation temperatures of the gas stream. The sensor characterization demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of sterilization processes. Y1 - 2010 U6 - https://doi.org/10.1016/j.proeng.2010.09.098 SN - 1877-7058 N1 - Eurosensor XXIV Conference, 5-8 September 2010, Linz, Austria VL - 5 SP - 264 EP - 267 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Kerpen, N. B. A1 - Bung, Daniel Bernhard A1 - Schlurmann, Torsten ED - Janssen, Robert T1 - Physical model investigations of ships passing through a lock T2 - Hydraulic structures: useful water harvesting systems or relics? : Third International Junior Researcher and Engineer Workshop on Hydraulic Structures (IJREWHS'10) : Edinburgh, Scotland, U.K., 2-3 May 2010 Y1 - 2010 SN - 9781742720159 SP - 93 EP - 100 PB - School of Civil Engineeering, The University of Queensland CY - Brisbane ER - TY - CHAP A1 - Kerpen, N. B. A1 - Bung, Daniel Bernhard A1 - Schlurmann, Torsten T1 - Physical model investigations of pressure distributions next to ships passing through a lock T2 - 5th Chinese-German Joint Symposium on Hydraulic and Ocean Engineering : CG JOINT 2010 Y1 - 2010 SN - 978-7-5618-3671-2 SP - 514 EP - 519 PB - Univ. Press CY - Tianjin ER - TY - CHAP A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Probability of lightning strikes to air-terminations of structures using the electro-geometrical model theory and the statistics of lightning current parameters N2 - Planning the air-terminations for a structure to be protected the use of the rolling-sphere method (electro-geometrical model) is the best way from the physics of lightning point-of-view. Therefore, international standards prefer this method. However, using the rolling-sphere method only results in possible point-of-strikes on a structure without giving information about the probability of strikes at the individual points compared to others. KW - atmospheric modeling KW - probability distribution KW - lightning protection KW - standards KW - planning Y1 - 2010 SN - 978-88-905519-0-1 U6 - https://doi.org/10.1109/ICLP.2010.7845757 N1 - 2010 30th International Conference on Lightning Protection (ICLP), 13-17 Sept. 2010, Cagliari, Italy SP - 750-1 EP - 750-8 PB - IEEE CY - New York ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Die dynamische Blitzkugel : Wahrscheinlichkeitsberechnung für Blitzeinschläge in Gebäude JF - de - Fachzeitschrift für das Elektrohandwerk Y1 - 2010 SN - 2509-517X IS - 13-14 SP - 24 EP - 29 PB - Hüthig CY - Heidelberg ER - TY - JOUR A1 - Kern, Alexander A1 - Klöters, Georg A1 - Pferdemenges, Jörg T1 - Optimised protection against lightning for the signalling and safety systems of level crossings on non-electrified railway lines JF - RTR : European Rail Technology Review Y1 - 2010 SN - 0079-9548 VL - 50 IS - 2 PB - DVV Media Group CY - Hamburg ER - TY - CHAP A1 - Kern, Alexander A1 - Frentzel, Ralf A1 - Behrens, Jörg T1 - Simulation of the transient voltages in the auxiliary power network of a large power plant in case of a direct lightning strike to the high-voltage overhead transmission line N2 - Large power plants can be endangered by lightning strikes with possible consequences regarding their safety and availability. A special scenario is a lightning strike to the HV overhead transmission line close to the power plant's connection to the power grid. If then additionally a so-called shielding failure of the overhead ground wire on top of the overhead transmission line is assumed, i.e. the lightning strikes directly into a phase conductor, this is an extreme electromagnetic disturbance. The paper deals with the numerical simulation of such a lightning strike and the consequences on the components of the power plant's auxiliary power network connected to different voltage levels. KW - power generation KW - surges KW - conductors KW - arresters KW - power transmission lines KW - lightning Y1 - 2010 SN - 978-88-905519-0-1 U6 - https://doi.org/10.1109/ICLP.2010.7845756 N1 - 2010 30th International Conference on Lightning Protection (ICLP), 13-17 Sept. 2010, Cagliari, Italy SP - 749-1 EP - 749-7 PB - IEEE CY - New York ER -