TY - CHAP A1 - Pomp, Stefan A1 - Schwarzbözl, Peter A1 - Koll, Gerrit A1 - Hennecke, Klaus A1 - Schmitz, Mark A1 - Hoffschmidt, Bernhard T1 - Advanced concept for a solar thermal power plant with open volumetric air receiver T2 - SolarPACES 2010 : the CSP Conference: electricity, fuels and clean water from concentrated solar energy ; 21 to 24 September 2010, Perpignan, France Y1 - 2010 SP - 97 EP - 98 PB - Soc. OSC CY - Saint Maur ER - TY - JOUR A1 - Jacobs, Stephan T1 - Agilität in Großprojekten durch „Integration Driven Design“ : ein Erfahrungsbericht JF - Softwaretechnik-Trends (STT) N2 - Der folgende Bericht fasst Erfahrungen zusammen, die in großen Entwicklungsprojekten der Firma Ericsson über mehrere Jahre gesammelt wurden. Ziel war dabei nicht, agile Methoden und Techniken einzusetzen - Agilität war zu der Zeit noch kein Hype-Thema. Vielmehr wurden Schwächen in den eigenen Projekten identifiziert und verbessert. Der Erfahrungsbericht vergleicht Verbesserungen in diesen Projekten mit den Ansätzen der agilen Entwicklung. Als Ergebnis werden folgende Punkte festgehalten: Erstens, einige Praktiken und Werte der agilen Entwicklung lassen sich auch in Großprojekten einsetzen. Zweitens, bei der Skalierung für Großprojekte werden diese Praktiken langsamer getaktet. Drittens, agile Entwicklung ist nicht nur eine Reihe von Praktiken und Werten, agile Entwicklung ist vielmehr auch eine Frage der Entwicklungs- und Projektkultur. Diese kulturelle Änderung lässt sich in Großprojekten deutlich langsamer umsetzen. Y1 - 2010 SN - 0720-8928 VL - 30 IS - 3 PB - GI - Gesellschaft für Informatik CY - Bonn ER - TY - CHAP A1 - Baumann, Torsten A1 - Teixeira Boura, Cristiano José A1 - Göttsche, Joachim A1 - Hoffschmidt, Bernhard A1 - O'Connell, Bryan A1 - Schmitz, Stefan A1 - Zunft, Stefan T1 - Air/Sand heat exchanger design and materials for solar thermal power plant applications T2 - SolarPACES 2010 : the CSP Conference: electricity, fuels and clean water from concentrated solar energy ; 21 to 24 September 2010, Perpignan, France Y1 - 2010 SP - 146 EP - 147 PB - Soc. OSC CY - Saint Maur ER - TY - JOUR A1 - Gronsfeld, Richard A1 - Sparla, Peter A1 - Weinnhold, Wolfgang T1 - Airborne und terrestrisches Laserscanning - neue Tools für den Talsperrenbetreiber? JF - Wasserwirtschaft Y1 - 2010 U6 - https://doi.org/10.1007/BF03241621 SN - 0043-0978 VL - 100 IS - 4 SP - 80 EP - 82 PB - Springer Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Ziolko, C. A1 - Schmitz, M. A1 - Sattler, Johannes Christoph A1 - Khedim, Ahmed A1 - Hoffschmidt, Bernhard T1 - AlSol - the open volumetric receiver technology moves to Africa T2 - SolarPACES 2010 : the CSP Conference: electricity, fuels and clean water from concentrated solar energy ; 21 to 24 September 2010, Perpignan, France Y1 - 2010 SP - 93 EP - 94 PB - Soc. OSC CY - Saint Maur ER - TY - CHAP A1 - Pfaff, Raphael A1 - Larkowski, Tomasz A1 - Burnham, Keith J. T1 - An approach to adaptive control in the behavioural framework T2 - UKACC International Conference on Control 2010 (CONTROL 2010) : Coventry, United Kingdom, 7 - 10 September 2010 ; Vol. 2. (IET seminar digest ; 2010/004) Y1 - 2010 SN - 978-1-62748-119-9 SP - 833 EP - 838 PB - Curran CY - Red Hook, NY ER - TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Dammann, Philipp A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T JF - Medical Physics N2 - Purpose: MRI plays a leading diagnostic role in assessing the musculoskeletal (MSK) system and is well established for most questions at clinically used field strengths (up to 3 T). However, there are still limitations in imaging early stages of cartilage degeneration, very fine tendons and ligaments, or in locating nerve lesions, for example. 7 T MRI of the knee has already received increasing attention in the current published literature, but there is a strong need to develop new radiofrequency (RF) coils to assess more regions of the MSK system. In this work, an eight-channel transmit/receive RF array was built as a multipurpose coil for imaging some of the thus far neglected regions. An extensive coil characterization protocol and first in vivo results of the human wrist, shoulder, elbow, knee, and ankle imaged at 7 T will be presented. Methods: Eight surface loop coils with a dimension ofurn:x-wiley:00942405:media:mp7176:mp7176-math-0001 were machined from FR4 circuit board material. To facilitate easy positioning, two coil clusters, each with four loop elements, were combined to one RF transmit/receive array. An overlapped and shifted arrangement of the coil elements was chosen to reduce the mutual inductance between neighboring coils. A phantom made of body-simulating liquid was used for tuning and matching on the bench. Afterward, the S-parameters were verified on a human wrist, elbow, and shoulder. For safety validation, a detailed compliance test was performed including full wave simulations of the RF field distribution and the corresponding specific absorption rate (SAR) for all joints. In vivo images of four volunteers were assessed with gradient echo and spin echo sequences modified to obtain optimal image contrast, full anatomic coverage, and the highest spatial resolution within a reasonable acquisition time. The performance of the RF coil was additionally evaluated by in vivo B1 mapping. Results: A comparison of B1 per unit power, flip angle distribution, and anatomic images showed a fairly homogeneous excitation for the smaller joints (elbow, wrist, and ankle), while for the larger joints, the shoulder and especially the knee, B1 inhomogeneities and limited penetration depth were more pronounced. However, the greater part of the shoulder joint could be imaged.In vivo images rendered very fine anatomic details such as fascicles of the median nerve and the branching of the nerve bundles. High-resolution images of cartilage, labrum, and tendons could be acquired. Additionally, turbo spin echo (TSE) and inversion recovery sequences performed very well. Conclusions: This study demonstrates that the concept of two four-channel transmit/receive RF arrays can be used as a multipurpose coil for high-resolutionin vivo MR imaging of the musculoskeletal system at 7 T. Not only gradient echo but also typical clinical and SAR-intensive sequences such as STIR and TSE performed well. Imaging of small structures and peripheral nerves could in particular benefit from this technique. Y1 - 2010 U6 - https://doi.org/10.1118/1.3517176 SN - 2473-4209 VL - 37 IS - 12 SP - 6368 EP - 6376 PB - Wiley CY - Hoboken, NJ ER - TY - CHAP A1 - Magnor, D. A1 - Soltau, N. A1 - Bragard, Michael A1 - Schmiegel, A. A1 - De Doncker, R. W. A1 - Sauer, D. U. ED - de Santi, Giovanni Frederigo T1 - Analysis of the model dynamics for the battery and battery converter in a grid-connected 5 kW photovoltaic system T2 - Proceedings / 25th European Photovoltaic Solar Energy Conference and Exhibition ; 5th World Conference on Photovoltaic Energy Conversion ; Feria Valencia, Convention & Exhibition Centre, Valencia, Spain, conference 6 - 10 September 2010, exhibition 6 - 9 September 2010 ; Joint World Conference of: 25th European Photovoltic Solar Energy Conference and Exhibition, 36th US IEEE Photovoltaic Specialists Conference, 20th Asia/Pacific PV Science and Engineering Conference Y1 - 2010 SN - 3-936338-26-4 (DVD-ROM) N1 - EU PVSEC WCPEC PB - WIP Renewable Energies CY - [München] ER - TY - JOUR A1 - Siqueira, José R. Jr. A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Associating biosensing properties with the morphological structure of multilayers containing carbon nanotubes on field-effect devices JF - Physica Status Solidi (A) N2 - The control of molecular architecture provided by the layer-by-layer (LbL) technique has led to enhanced biosensors, in which advantageous features of distinct materials can be combined. Full optimization of biosensing performance, however, is only reached if the film morphology is suitable for the principle of detection of a specific biosensor. In this paper, we report a detailed morphology analysis of LbL films made with alternating layers of single-walled carbon nanotubes (SWNTs) and polyamidoamine (PAMAM) dendrimers, which were then covered with a layer of penicillinase (PEN). An optimized performance to detect penicillin G was obtained with 6-bilayer SWNT/PAMAM LbL films deposited on p-Si-SiO2-Ta2O5 chips, used in biosensors based on a capacitive electrolyte-insulator-semiconductor (EIS) and a light-addressable potentiometric sensor (LAPS) structure, respectively. Field-emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM) images indicated that the LbL films were porous, with a large surface area due to interconnection of SWNT into PAMAM layers. This morphology was instrumental for the adsorption of a larger quantity of PEN, with the resulting LbL film being highly stable. The experiments to detect penicillin were performed with constant-capacitance (ConCap) and constant-current (CC) measurements for EIS and LAPS sensors, respectively, which revealed an enhanced detection signal and sensitivity of ca. 100 mV/decade for the field-effect sensors modified with the PAMAM/SWNT LbL film. It is concluded that controlling film morphology is essential for an enhanced performance of biosensors, not only in terms of sensitivity but also stability and response time. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983301 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 781 EP - 786 PB - Wiley-VCH CY - Berlin ER - TY - GEN A1 - Pasteur, A. A1 - Ludwig, B. A1 - Tippkötter, Nils A1 - Diller, R. A1 - Kampeis, P. A1 - Ulber, Roland T1 - Aufarbeitung von β-Lactamantibiotika mittels selektiver, magnetischer Adsorbermaterialien T2 - Chemie Ingenieur Technik N2 - b-Lactame gehören zu den wirkungsvollsten Antibiotika, jedoch lassen sich viele nur schwierig fermentativ erzeugen. Ein Problem bei der fermentativen Produktion ist die Hydrolyse des Lactamrings im wässrigen Milieu. Das Ziel des von der DBU geförderten Projekts ist die selektive In-situ-Adsorption der b-Lactamantibiotika unter anschließender magnetischer Separation. Durch die Isolation im Hochgradientenmagnetseparator (HGMS) ist eine Fest-fest-flüssig-Trennung und somit ein erheblicher Zeitgewinn im Downstreamprozess möglich. Zusätzlich kommt es zur Einsparung an Lösungsmittel und Energie, was neben Reduzierung der Antibiotikahydrolyse auch in ökologischer Hinsicht einen interessanten Aspekt darstellt. Als Trägermaterial für die Adsorbermatrix werden magnetisierbare Eisenoxidpartikel eingesetzt, die in einer Silikamatrix eingebettet sind. Diese Adsorber sollen auf Selektivität in Wasser und verschiedenen Medien getestet werden. Zusätzlich werden die Abbauprodukte des b-Lactams analysiert, um eine Aussage über die Stabilisierung des Antibiotikums durch die selektiven Adsorber treffen zu können. Diese Ergebnisse werden mit kommerziell erhältlichen Adsorbern verglichen. Die Aufreinigung der Antibiotika soll direkt aus der Fermentationsbrühe erfolgen. Um die Trennung der magnetischen, selektiven Adsorber von der Biomasse zu gewährleisten, soll der HGMS in die Fermentation integriert werden. Das filamentöse Wachstum des Mikroorganismus erfordert eine Neuauslegung der Filtermatrix. KW - β-Lactame KW - Magnetische Adsorbermaterialien Y1 - 2010 U6 - https://doi.org/10.1002/cite.201050270 N1 - ProcessNet-Jahrestagung 2010 und 28. DECHEMA-Jahrestagung der Biotechnologen, 21. - 23. September 2010, Eurogress Aachen VL - 82 IS - 9 SP - 1587 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Wollert, Jörg A1 - Leidinger, Rafael T1 - Automation trifft Automotive : SPS in der Fahrzeugtechnik JF - Elektronik automotive : Magazin für Entwicklungen in der Kfz-Elektronik und Telematik N2 - Eine SPS im Kraftfahrzeug? Das geht ja gar nicht – da gibt es doch all die Hersteller für Kfz-Steuergeräte, die konfigurierbare Hardware anbieten. Im Prinzip ja, aber leider sind gerade die Sensoren oder Aktoren nicht ansteuerbar, die der Entwickler genau für sein aktuelles Projekt benötigt. Dieser Beitrag gibt einen kleinen Einblick in neue Möglichkeiten des Rapid Prototyping für mechatronische Systeme auf der Basis von Speicherprogrammierbaren Steuerungen (SPS). Y1 - 2010 SN - 1614-0125 IS - 4/5 SP - 44 EP - 48 PB - WEKA Fachmedien CY - Haar ER - TY - JOUR A1 - Poghossian, Arshak A1 - Wagner, Holger A1 - Schöning, Michael Josef T1 - Automatisiertes „wafer level“-Testsystem zur Charakterisierung von siliziumbasierten Chemo- und Biosensoren JF - Tagungsband: Sensoren und Messsysteme 2010 N2 - Es wurde ein automatisiertes, computerunterstütztes Testsystem für die Funktionsprüfung und Charakterisierung von (bio-)chemischen Sensoren auf Waferebene entwickelt und in einen konventionellen Spitzenmessplatz integriert. Das System ermöglicht die Charakterisierung und Identifizierung „funktionstauglicher“ Sensoren bereits auf Waferebene zwischen den einzelnen Herstellungsschritten, wodurch weitere, bisher übliche Verarbeitungsschritte wie das Fixieren, Bonden und Verkapseln für die defekten oder nicht funktionstauglichen Sensorstrukturen entfällt. Außerdem bietet eine speziell entworfene miniaturisierte Durchflussmesszelle die Möglichkeit, bereits auf Waferlevel die Sensitivität, Drift, Hysterese und Ansprechzeit der (bio-)chemischen Sensoren zu charakterisieren. Das System wurde exemplarisch mit kapazitiven, pH-sensitiven EIS- (Elektrolyt-Isolator-Silizium) Strukturen und ISFET- (ionensensitiver Feldeffekttransistor) Strukturen mit verschiedenen Geometrien und Gate-Layouts getestet. Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Sensoren und Messsysteme 2010 - 15. ITG/GMA-Fachtagung, 18.05.2010 - 19.05.2010 in Nürnberg SP - 89 EP - 92 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Christen, Marc A1 - Bartelt, Perry A1 - Kowalski, Julia T1 - Back calculation of the In den Arelen avalanche with RAMMS: Interpretation of model results JF - Annals of Glaciology N2 - Two- and three-dimensional avalanche dynamics models are being increasingly used in hazard-mitigation studies. These models can provide improved and more accurate results for hazard mapping than the simple one-dimensional models presently used in practice. However, two- and three-dimensional models generate an extensive amount of output data, making the interpretation of simulation results more difficult. To perform a simulation in three-dimensional terrain, numerical models require a digital elevation model, specification of avalanche release areas (spatial extent and volume), selection of solution methods, finding an adequate calculation resolution and, finally, the choice of friction parameters. In this paper, the importance and difficulty of correctly setting up and analysing the results of a numerical avalanche dynamics simulation is discussed. We apply the two-dimensional simulation program RAMMS to the 1968 extreme avalanche event In den Arelen. We show the effect of model input variations on simulation results and the dangers and complexities in their interpretation. KW - avalanche Y1 - 2010 SN - 1727-5644 U6 - https://doi.org/10.3189/172756410791386553 VL - 51 IS - 54 SP - 161 EP - 168 PB - Cambridge University Press CY - Cambridge ER - TY - BOOK A1 - Müller, Karsten T1 - Bedarfsorientierte Instandhaltung von Kanalisationen Y1 - 2010 SN - 978-3-8167-8060-1 PB - IRB Verl. CY - Stuttgart ER - TY - JOUR A1 - Gossla, Ulrich A1 - Buttel, Luc A1 - Wahrmund, Holger A1 - Mehlig, Bernd T1 - Bemessung, Anwendung und Qualitätssicherung von Stahlfaserspritzbeton im Tunnelbau JF - Beton- und Stahlbetonbau N2 - Die Spritzbetonbauweise hat sich im Tunnelbau seit Jahren bewährt. Spritzbeton wird als unbewehrter Beton, in Verbindung mit Bewehrung sowie als Stahlfaserspritzbeton eingesetzt. Bei den meisten Tunnelschalen aus Stahlfaserspritzbeton werden Stahlfasern derzeit nur als konstruktive Bewehrung verwendet. Die Faserzugabe führt zu einer nennenswerten Erhöhung der Bruchenergie und somit zu einer höheren Zähigkeit des sonst spröden Materials und damit zu einer höheren Sicherheit. Stahlfaserspritzbeton kann auch anstelle von Spritzbeton mit statisch erforderlicher Mattenbewehrung eingesetzt werden. Die Bemessung erfolgt dann unter Berücksichtigung der Nachrisszugfestigkeit. Diese kann wie bei Stahlfaserbeton an Biegebalken ermittelt werden, die aus größeren Proben herausgesägt werden. Anhand von verschiedenen Beispielen werden die unterschiedlichen Anwendungen aufgezeigt und die dafür erforderlichen Prüfungen vorgestellt. Y1 - 2010 U6 - https://doi.org/10.1002/best.200900688 SN - 0005-9900 VL - 105 IS - 2 SP - 92 EP - 101 PB - Ernst & Sohn CY - Berlin ER - TY - CHAP A1 - Damm, Sebastian A1 - Ritz, Thomas A1 - Strauch, Jakob ED - Klink, Stefan T1 - Benutzerzentrierte Anforderungsanalyse für die Produktlinien-Entwicklung mobiler Unternehmenssoftware T2 - EMISA 2010 : Einflussfaktoren auf die Entwicklung flexibler, integrierter Informationssysteme ; Beiträge des Workshops der GI-Fachgruppe Entwicklungsmethoden für Informationssysteme und deren Anwendung (EMISA), 07. - 08.10.2010 in Karlsruhe, Germany. - (GI-Edition : Proceedings ; 172) Y1 - 2010 SN - 978-3-88579-266-6 SP - 117 EP - 130 PB - Ges. für Informatik CY - Bonn ER - TY - BOOK A1 - Barnat, Miriam T1 - Beobachtungskommunikation Y1 - 2010 N1 - Research Report / Technische Universität Hamburg-Harburg, Institut für Technik und Gesellschaft, 18; Deposit Licence - Keine Weiterverbreitung, keine Bearbeitung ER - TY - JOUR A1 - Stefan, Middendorf A1 - Olbertz, Klaus T1 - Betriebsratswahlen 2010 JF - NWB - Steuer- und Wirtschaftsrecht N2 - Die nächsten regelmäßigen Wahlen zum Betriebsrat (BR) stehen vor der Tür. Sie finden in der Zeit vom 1.3.2010 bis 31.5.2010 statt. Die Wahlen sind zwar vornehmlich Sache der Arbeitnehmer, allerdings sollten auch die Arbeitgeber darauf achten, dass die Wahlen korrekt ablaufen, schließlich haben die Arbeitgeber die Kosten der Wahlen zu tragen. Kommt es hierbei zu Fehlern, die schlimmstenfalls eine Wiederholung der Wahlen erfordern, hat auch für die hierdurch zusätzlich entstehenden Kosten der Arbeitgeber aufzukommen. Zudem bietet die aktive und unterstützende Begleitung der Wahlen für die Arbeitgeber die Chance, die Grundlagen für eine konstruktive Zusammenarbeit mit dem künftigen Betriebsrat zu legen. Der vorliegende Beitrag erläutert die wesentlichen Abläufe des Wahlverfahrens sowie die hierbei zwingend zu beachtenden Fristen. Y1 - 2018 SN - 1860-9449 IS - 4 SP - 290 EP - 297 PB - NWB-Verlag CY - Herne ER - TY - JOUR A1 - Butenweg, Christoph T1 - Bewertung der Erdbebensicherheit von bestehenden Bauwerken JF - Österreichische Ingenieur- und Architekten-Zeitschrift : ÖIAZ ; Zeitschr. d. ÖIAV / Österreichischer Ingenieur- und Architekten-Verein Y1 - 2010 SN - 0721-9415 VL - 155 IS - 1-3 und 4-6 SP - 11 EP - 17 PB - ÖAIV CY - Wien ER - TY - BOOK A1 - Timme, Michael T1 - BGB Crashkurs : der sichere Weg durch die Prüfung ; [Fall für Fall durch das Privatrecht] Y1 - 2010 SN - 978-3-406-60803-2 N1 - Beck kompakt PB - Beck CY - München ER - TY - JOUR A1 - Benzel, Ute A1 - Linzbach, Meike T1 - Bilanzierung und Offenlegung von Ertragsteuerrisiken – Quo vadis? Unsichere Steuerpositionen in der Rechnungslegung nach IFRS, US-GAAP und HGB JF - IRZ - Zeitschrift für Internationale Rechnungslegung N2 - In den letzten drei bis vier Jahren unterlag der Bereich der Bilanzierung und Offenlegung von unsicheren Steuerpositionen im IFRS- und US-GAAP-Abschluss einem stetigen Wandel. Sowohl nach US-GAAP als auch nach IFRS nehmen die Anforderungen an die Bilanzierung und Offenlegung beständig zu. Schon allein dies zeigt die Bedeutung, die dem Themenbereich der Steuerrisiken beigemessen wird. Aber nicht nur im Rahmen der Berichterstattung im Jahresabschluss stehen Steuerrisiken oben auf der Agenda, auch der amerikanische Internal Revenue Service (IRS) verfolgt das Thema sehr konsequent und plant, bestimmte Unternehmen zu Angaben von Steuerrisiken im Rahmen der Steuererklärungen zu verpflichten. Der Aufsatz befasst sich mit den neueren Entwicklungen im Bereich der Bilanzierung und Offenlegung von unsicheren Steuerpositionen in der Rechnungslegung nach IFRS, US-GAAP und HGB und der Offenlegung von Steuerrisiken im Rahmen der Steuererklärung. Y1 - 2010 SN - 1862-5533 IS - 11 SP - 475 EP - 523 ER - TY - JOUR A1 - Olbertz, Klaus A1 - Thiergart, Kirsten T1 - Börsengang leicht gemacht? Gesellschafts- und arbeitsrechtliche Aspekte bei Übernahme und Verschmelzung eines Zielunternehmens auf die SPAC in der Rechtsform der SE JF - Betriebs-Berater: BB ; Recht, Wirtschaft, Steuern N2 - Die SPAC-SE ist börsenfähig und damit eine für eine SPAC grundsätzlich geeignete Rechtsform. Die Tatsache, dass es sich hierbei (zunächst) um eine leere, arbeitnehmerlose Hülle handelt, ändert hieran nichts. Die Gründung einer solchen Vorrats-SE ist trotz fehlender Arbeitnehmerbeteiligung unter teleologischer Reduktion von Art. 12 II SE-VO zulässig. Im Gegenzug muss die Arbeitnehmerbeteiligung gemaß § 18 III SEBG analog nachgeholt werden, wenn das später erworbene Zielunternehmen auf die SPAC-SE verschmolzen werden soll. Aus gesellschaftsrechtlicher Sicht ist zu beachten, dass die SPAC-SE mit Sitz in Deutschland, welche auch den deutschen, aktienrechtlichen Bestimmungen unterliegt, nur bedingt für eine SPAC geeignet erscheint. Das deutsche Aktienrecht enthält strenge Regelungen, die der für eine SPAC-SE erforderlichen Flexibilität entgegenstehen können. Dies gilt insbesondere für das Erfordernis der Zustimmung der Hauptversammlung zur Akquisition des Zielunternehmens, die Rückzahlung des Treuhandvermögens an Aktionäre, die der Akquisition nicht zugestimmt haben und die Liquidation der SPAC-SE im Falle des Scheiterns des Erwerbs des Zielobjektes. Y1 - 2018 SN - 0340-7918 SP - 1547 PB - Beck CY - München ER - TY - JOUR A1 - Ribitsch, Doris A1 - Karl, Wolfgang A1 - Birner-Gruenberger, R. A1 - Gruber, K. A1 - Eiteljoerg, I. A1 - Remler, Peter A1 - Wieland, S. A1 - Siegert, Petra A1 - Maurer, Karl-Heinz A1 - Schwab, H. T1 - C-terminal truncation of a metagenome-derived detergent protease for effective expression in E. coli JF - Journal of biotechnology N2 - Recently, a new alkaline protease named HP70 showing highest homology to extracellular serine proteases of Stenotrophomonas maltophilia and Xanthomonas campestris was found in the course of a metagenome screening for detergent proteases (Niehaus et al., submitted for publication). Attempts to efficiently express the enzyme in common expression hosts had failed. This study reports on the realization of overexpression in Escherichia coli after structural modification of HP70. Modelling of HP70 resulted in a two-domain structure, comprising the catalytic domain and a C-terminal domain which includes about 100 amino acids. On the basis of the modelled structure the enzyme was truncated by deletion of most of the C-terminal domain yielding HP70-C477. This structural modification allowed effective expression of active enzyme using E. coli BL21-Gold as the host. Specific activity of HP70-C477 determined with suc-l-Ala-l-Ala-l-Pro-l-Phe-p-nitroanilide as the substrate was 30 ± 5 U/mg compared to 8 ± 1 U/mg of the native enzyme. HP70-C477 was most active at 40 °C and pH 7–11; these conditions are prerequisite for a potential application as detergent enzyme. Determination of kinetic parameters at 40 °C and pH = 9.5 resulted in KM = 0.23 ± 0.01 mM and kcat = 167.5 ± 3.6 s⁻¹. MS-analysis of peptide fragments obtained from incubation of HP70 and HP70-C477 with insulin B indicated that the C-terminal domain influences the cleavage preferences of the enzyme. Washing experiments confirmed the high potential of HP70-C477 as detergent protease. Y1 - 2010 U6 - https://doi.org/10.1016/j.jbiotec.2010.09.947 SN - 1873-4863 (E-Journal); 0168-1656 (Print) VL - 150 IS - 3 SP - 408 EP - 416 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Siqueira, José R. Jr. A1 - Oliveira, Osvaldo N. Jr. A1 - Moritz, Werner A1 - Schöning, Michael Josef T1 - Capacitive electrolyte-insulator-semiconductor structures functionalised with a polyelectrolyte/enzyme multilayer: New strategy for enhanced field-effect biosensing JF - Physica Status Solidi (A) N2 - A novel strategy for enhanced field-effect biosensing using capacitive electrolyte–insulator–semiconductor (EIS) structures functionalised with pH-responsive weak polyelectrolyte/enzyme or dendrimer/enzyme multilayers is presented. The feasibility of the proposed approach is exemplarily demonstrated by realising a penicillin biosensor based on a capacitive p-Si–SiO2 EIS structure functionalised with a poly(allylamine hydrochloride) (PAH)/penicillinase and a poly(amidoamine) dendrimer/penicillinase multilayer. The developed sensors response to changes in both the local pH value near the gate surface and the charge of macromolecules induced via enzymatic reaction, resulting in a higher sensitivity. For comparison, an EIS penicillin biosensor with adsorptively immobilised penicillinase has been also studied. The highest penicillin sensitivity of 100 mV/dec has been observed for the EIS sensor functionalised with the PAH/penicillinase multilayer. The lower and upper detection limit was around 20 µM and 10 mM, respectively. In addition, an incorporation of enzymes in a multilayer prepared by layer-by-layer technique provides a larger amount of immobilised enzymes per sensor area, reduces enzyme leaching effects and thus, enhances the biosensor lifetime (the loss of penicillin sensitivity after 2 months was 10–12%). Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983317 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 884 EP - 890 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Wenmackers, Sylvia A1 - Janssens, Stoffel D. A1 - Haenen, Ken A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Capacitive field-effect (bio-)chemical sensors based on nanocrystalline diamond films JF - MRS Online Proceedings Library N2 - Capacitive field-effect electrolyte-diamond-insulator-semiconductor (EDIS) structures with O-terminated nanocrystalline diamond (NCD) as sensitive gate material have been realized and investigated for the detection of pH, penicillin concentration, and layer-by-layer adsorption of polyelectrolytes. The surface oxidizing procedure of NCD thin films as well as the seeding and NCD growth process on a Si-SiO2 substrate have been improved to provide high pH-sensitive, non-porous thin films without damage of the underlying SiO2 layer and with a high coverage of O-terminated sites. The NCD surface topography, roughness, and coverage of the surface groups have been characterized by SEM, AFM and XPS methods. The EDIS sensors with O-terminated NCD film treated in oxidizing boiling mixture for 45 min show a pH sensitivity of about 50 mV/pH. The pH-sensitive properties of the NCD have been used to develop an EDIS-based penicillin biosensor with high sensitivity (65-70 mV/decade in the concentration range of 0.25-2.5 mM penicillin G) and low detection limit (5 μM). The results of label-free electrical detection of layer-by-layer adsorption of charged polyelectrolytes are presented, too. Y1 - 2010 SN - 1946-4274 VL - 1203 PB - MRS CY - Warrendale ER - TY - JOUR A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Frauenrath, Tobias A1 - Prothmann, Marcel A1 - Dieringer, Matthias A. A1 - Hezel, Fabian A1 - Renz, Wolfgang A1 - Kretschel, Kerstin A1 - Niendorf, Thoralf A1 - Schulz-Menger, Jeanette T1 - Cardiac chamber quantification using magnetic resonance imaging at 7 Tesla—a pilot study N2 - Objectives Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T. Methods A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated. Results All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm. Conclusions This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T. Y1 - 2010 U6 - https://doi.org/10.1007/s00330-010-1888-2 SN - 0938-7994 VL - 20 SP - 2844 EP - 2852 PB - Springer CY - Berlin, Heidelberg ER - TY - JOUR A1 - Mukherjee, Krishnendu A1 - Prahl, Ulrich A1 - Bleck, Wolfgang A1 - Reisgen, Uwe A1 - Schleser, Markus A1 - Abdurakhmanov, Aydemir T1 - Characterization and modelling techniques for gas metal arc welding of DP 600 sheet steels JF - Materialwissenschaft und Werkstofftechnik N2 - The objectives of the present work are to characterize the Gas Metal Arc Welding process of DP 600 sheet steel and to summarize the modelling techniques. The time-temperature evolution during the welding cycle was measured experimentally and modelled with the softwaretool SimWeld. To model the phase transformations during the welding cycle dilatometer tests were done to quantify the parameters for phase field modelling by MICRESS®. The important input parameters are interface mobility, nucleation density, etc. A contribution was made to include austenite to bainite transformation in MICRESS®. This is useful to predict the microstructure in the fast cooling segments. The phase transformation model is capable to predict the microstructure along the heating and cooling cycles of welding. Tensile tests have shown the evidence of failure at the heat affected zone, which has the ferrite-tempered martensite microstructure. Y1 - 2010 U6 - https://doi.org/10.1002/mawe.201000692 SN - 1521-4052 VL - 41 IS - 11 SP - 972 EP - 983 PB - Wiley-VCH CY - Weinheim ER - TY - CHAP A1 - Muffler, Kai A1 - Tippkötter, Nils A1 - Ulber, Roland ED - Timmis, Kenneth N. T1 - Chemical feedstocks and fine chemicals from other substrates T2 - Handbook of hydrocarbon and lipid microbiology. Volume 4: Consequences of microbial interactions with hydrocarbons, oils and lipids. - (Springer reference) Y1 - 2010 SN - 978-3-540-77588-1 U6 - https://doi.org/10.1007%2F978-3-540-77587-4_214 SP - 2891 EP - 2902 PB - Springer CY - Berlin [u.a.] ER - TY - GEN A1 - Staub, C. A1 - Tippkötter, Nils A1 - Suck, K. A1 - Sohling, U. A1 - Ulber, Roland T1 - Chromatographische Aufarbeitung von Molkekonzentrat mittels mineralischer Granulate T2 - Chemie Ingenieur Technik N2 - Molke fällt im Rahmen der Käseherstellung allein in Deutschland in Mengen von über 11 Mio. Tonnen jährlich an. Dieses Nebenprodukt wurde trotz seines Reichtums an Milchzucker und Proteinen lange Zeit kaum industriell weiterverarbeitet und stellte ein bedeutendes Problem bei der Abwasserreinigung dar. Derzeit kommen meist kosten- und reinigungsintensive Membranfiltrationsverfahren bei der Auftrennung von Molke in ihre Hauptkomponenten Lactose und Molkenprotein zum Einsatz. Die Produkte finden vorwiegend in der Nahrungsmittelindustrie Anwendung als Süßungsmittel, Proteinzusatz oder Texturbildner. Die Mehrheit des Proteins wird dabei als Konzentrat bzw. Proteinpulver verarbeitet. Wegen der antibakteriellen, antiviralen und weiteren wertvollen physiologischen Eigenschaften der Molkeproteine stellt eine weitere Aufreinigung der einzelnen Molkeproteine für die pharmazeutische Industrie einen naheliegenden zusätzlichen Wertschöpfungsschritt dar. In Kooperation mit der Süd Chemie AG wurde damit begonnen, ein Verfahren zu entwickeln, das kostengünstige mineralische Adsorbentien verwendet. Bisher konnte die Abtrennung von Lactose von den Molkenproteinen aus verdünntem Molkekonzentrat in einem Verfahrensschritt ohne Vorbehandlung des Rohstoffs erfolgreich realisiert werden. Aktuelle Arbeiten beschäftigen sich mit der Verbesserung der Proteinbindekapazitätund chromatographischen Proteinauftrennung sowie dem Upscaling zum direkten Einsatz von Molkekonzentrat ohne Vorverdünnung. KW - Adsorbentien KW - Molkenprotein Y1 - 2010 U6 - https://doi.org/10.1002/cite.201050322 SN - 0009-286X SN - 1522-2640 (eISSN) N1 - ProcessNet-Jahrestagung 2010 und 28. DECHEMA-Jahrestagung der Biotechnologen, 21. - 23. September 2010, Eurogress Aachen VL - 82 IS - 9 SP - 1588 EP - 1589 PB - Wiley-VCH CY - Weinheim ER - TY - RPRT A1 - Lanz, Marco A1 - Fricke, Barbara A1 - Anthrakidis, Anette A1 - Genter, Mirjam A1 - Hoffschmidt, Bernhard A1 - Faber, Christian A1 - Hauser, Eva A1 - Klann, Uwe A1 - Leprich, Uwe A1 - Bauknecht, Dierk A1 - Koch, Matthias A1 - Peter, Stefan T1 - CO2-Emissionsminderung durch Ausbau, informationstechnische Vernetzung und Netzoptimierung von Anlagen dezentraler, fluktuierender und erneuerbarer Energieerzeugung in Deutschland : Endbericht zum Vorhaben ; Kurzbezeichnung: CO2DEZ. Forschungsbericht / Umweltbundesamt. Bd. 1550. Förderkennzeichen: UFOPLAN 3707 46 100 Y1 - 2010 ER - TY - JOUR A1 - Balakrishnan, Karthikeyan A1 - Andrei-Selmer, Luminita-Cornelia A1 - Selmer, Thorsten A1 - Bacher, Michael A1 - Dodel, Richard T1 - Comparison of intravenous immunoglobulins for naturally occurring autoantibodies against amyloid-β JF - Journal of Alzheimer's Disease N2 - Intravenous immunoglobulins (IVIG) are currently used for therapeutic purposes in autoimmune disorders. Recently, we demonstrated the presence of naturally occurring antibodies against amyloid- β (nAbs-Aβ) within the pool of IVIG. In this study, we compared different brands of IVIG for nAbs-Aβ and have found differences in the specificity of the nAbs-Aβ towards Aβ1–40 and Aβ1–42 . We analyzed the influence of a pH-shift over the course of antibody storage using ELISA and investigated antibody dimerization at acidic and neutral pH as well as differences in the IgG subclass distributions among the IVIG using both HPLC and a nephelometric assay. Furthermore, we investigated the epitope region of purified nAbs-Aβ. The differences found in Aβ specificity are not directly proportionate to the binding nature of these antibodies when administered in vivo. This information, however, may serve as a guide when choosing the commercial source of IVIG for therapeutic applications in Alzheimer's disease Y1 - 2010 U6 - https://doi.org/10.3233/JAD-2010-1353 SN - 1387-2877 VL - 20 IS - 1 SP - 135 EP - 143 PB - IOS Press CY - Amsterdam ER - TY - GEN A1 - Frauenrath, Tobias A1 - Becker, Meike A1 - Hezel, Fabian A1 - Krombach, Gabriele A. A1 - Kremer, Ute A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Comparison of Left Function Assessment Using Phonocardiogram and Electrocardiogram Triggered 2D SSFP CINE MR Imaging at 1.5 T and 3.0 T T2 - 2010 ISMRM-ESMRMB joint annual meeting N2 - As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to distortions and mistriggering increases and with it the motivation for a cardiac triggering alternative. Hence, this study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects at 1.5T and 3.0T. Y1 - 2010 SN - 1545-4428 N1 - ISMRM-ESMRMB joint annual meeting, 1 - 7 May 2010, Stockholm, Sweden ER - TY - JOUR A1 - Becker, Meike A1 - Frauenrath, Tobias A1 - Hezel, Fabian A1 - Krombach, Gabriele A. A1 - Kremer, Ute A1 - Koppers, Benedikt A1 - Butenweg, Christoph A1 - Goemmel, Andreas A1 - Utting, Jane F. A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T JF - European Radiology N2 - Objective: As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n=14). Methods: Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT’s performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Results: Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct Rwave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects—even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), endsystolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived fromVCG-triggered acquisitions (1.5 T: ESVVCG=(56± 17) ml, EDVVCG=(151±32)ml, LVMVCG=(97±27) g, SVVCG=(94± 19)ml, EFVCG=(63±5)% cf. ESVACT= (56±18) ml, EDVACT=(147±36) ml, LVMACT=(102±29) g, SVACT=(91± 22) ml, EFACT=(62±6)%; 3.0 T: ESVVCG=(55±21) ml, EDVVCG=(151±32) ml, LVMVCG=(101±27) g, SVVCG=(96±15) ml, EFVCG=(65±7)% cf. ESVACT=(54±20) ml, EDVACT=(146±35) ml, LVMACT= (101±30) g, SVACT=(92±17) ml, EFACT=(64±6)%). Conclusions: ACT’s intrinsic insensitivity to interference from electromagnetic fields renders KW - Magnetic resonance imaging (MRI) KW - MR-stethoscope KW - Magnetic field strength KW - Left ventriular function KW - Cardiovascular MRI Y1 - 2010 U6 - https://doi.org/10.1007/s00330-009-1676-z SN - 1432-1084 (Onlineausgabe) SN - 0938-7994 (Druckausgabe) VL - 20 SP - 1344 EP - 1355 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kurz, R. A1 - Linder, Peter A1 - Trzewik, Jürgen A1 - Rüffer, M. A1 - Artmann, Gerhard A1 - Digel, Ilya A1 - Rothermel, A. A1 - Robitzki, A. A1 - Temiz Artmann, Aysegül T1 - Contractile tension and beating rates of self-exciting monolayers and 3D-tissue constructs of neonatal rat cardiomyocytes JF - Medical and Biological Engineering and Computing N2 - The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocytes. Cells were grown either within flexible, circular collagen gels or as monolayer on top of respective 1-mum thin silicone membranes. Membrane and cells were bulged outwards by air pressure. This biaxial strain distribution is rather similar the beating, blood-filled heart. The setup allowed presetting the mechanical residual stress level externally by adjusting the centre deflection, thus, mimicking hypertension in vitro. Tension was measured as oscillating differential pressure change between chamber and environment. A 0.5-mm thick collagen-cardiac myocyte tissue construct induced after 2 days of culturing (initial cell density 2 x 10(4) cells/ml), a mechanical tension of 1.62 +/- 0.17 microN/mm(2). Mechanical load is an important growth regulator in the developing heart, and the orientation and alignment of cardiomyocytes is stress sensitive. Therefore, it was necessary to develop the CellDrum technology with its biaxial stress-strain distribution and defined mechanical boundary conditions. Cells were exposed to strain in two directions, radially and circumferentially, which is similar to biaxial loading in real heart tissues. Thus, from a biomechanical point of view, the system is preferable to previous setups based on uniaxial stretching. Y1 - 2010 U6 - https://doi.org/10.1007/s11517-009-0552-y SN - 1741-0444 VL - 48 IS - 1 SP - 59 EP - 65 PB - Springer Nature CY - Cham ER - TY - JOUR A1 - Börner, Sebastian A1 - Funke, Harald A1 - Hendrick, P. A1 - Recker, E. T1 - Control system modifications for a hydrogen fuelled gas-turbine JF - Proceedings of ISROMAC 13 Y1 - 2010 SN - 978-1-617-38848-4 N1 - 13th International Symposium on Transport Phenomena and Dynamics of Rotating Machinery 2010 (ISROMAC-13), Honolulu, Hawaii, USA, April 4-7, 2010 SP - 665 EP - 670 PB - Curran CY - Red Hook, NY ER - TY - BOOK A1 - Gebhardt, Wolfram A1 - Wollert, Jörg T1 - Das Funkbuch : Evolution und Kommunikation / [hrsg. von der Steute Schaltgeräte GmbH & Co. KG, Löhne, Geschäftsbereich Wireless. Autoren: Wolfram Gebhardt und Jörg F. Wollert] Y1 - 2010 SN - 978-3-00-032905-0 PB - Steute CY - Löhne ER - TY - JOUR A1 - Frings, Michael T1 - Das neue Recht der Zahlungsdienste JF - NWB Steuer- und Wirtschaftsrecht Y1 - 2010 SN - 0028-3460 SP - 1151 EP - 1159 PB - NWB-Verlag CY - Herne ER - TY - JOUR A1 - Frings, Michael T1 - Das neue Recht des Verbraucherkredits JF - NWB Steuer- und Wirtschaftsrecht Y1 - 2010 SN - 0028-3460 IS - 20 SP - 1608 EP - 1617 PB - NWB-Verlag CY - Herne ER - TY - CHAP A1 - Schmiegel, A. A1 - Koch, K. A1 - Dittmer, M. A1 - Braun, M. A1 - Landau, M. A1 - Dick, C. A1 - Bragard, Michael A1 - Bücenbender, K. A1 - De Doncker, R.W. T1 - Das Sol-ion System : ein System zur Optimierung des Eigenverbrauchs von PV-Strom T2 - Photovoltaische Solarenergie : 25. Symposium ; 03. - 05. März 2010, Kloster Banz, Bad Staffelstein. - (Wissen für Profis) Y1 - 2010 SN - 978-3-941785-23-6 SP - 354 EP - 359 PB - OTTI, Ostbayerisches Technologie-Transfer-Inst. CY - Regensburg ER - TY - CHAP A1 - Stieglitz, Kristian A1 - Wollert, Jörg T1 - Database driven modernization and expansion of storage systems T2 - Proceedings : the 3rd International Multi-Conference on Engineering and Technological Innovation : June 29th - July 2nd, 2010, Orlando, Florida, USA ; vol. 2 Y1 - 2010 SN - 978-1-936338-03-0 SP - 180 EP - 183 PB - IIIS CY - Winter Garden, Fla. ER - TY - JOUR A1 - Biener, Ernst A1 - Sasse, Torsten A1 - Wemhoff, Thomas ED - Egloffstein, Thomas T1 - Deponie auf Deponie - Technische und genehmigungsrechtliche Aspekte JF - Band 19: Abschluss und Rekultivierung von Deponien und Altlasten 2010 : Die Umsetzung der neuen Deponieverordnung - praktische Erfahrungen im Vollzug und erste Änderungsverordnung zur neuen DepV ; Beiträge zum Seminar am 13. und 14. Oktober 2010 in Karlsruhe Y1 - 2010 SN - 978-3-939662-08-2 N1 - Seminar 2010.10.13-14, Karlsruhe SP - 73 EP - 84 PB - ICP-Eigenverlag CY - Karlsruhe ER - TY - CHAP A1 - Becker, Jörg A1 - Eggert, Mathias A1 - Knackstedt, Ralf T1 - Der Beitrag der Referenzmodellierung zur Compliance im Reporting des Finanzsektors T2 - Business Intelligence Operational Structures: Towards the Design of a Reference Process Map Y1 - 2010 N1 - Zweites Forschungskolloquium Business Intelligence (FKBI 10) der GI-Fachgruppe Management Support Systems in Zusammenarbeit mit dem Competence Center for Business Intelligence an der Technischen Universität Dresden am 17. und 18. September 2010 in Dresden SP - 11 EP - 18 ER - TY - CHAP A1 - Bragard, Michael A1 - Soltau, N. A1 - De Doncker, R. W. A1 - Schmiegel, A. T1 - Design and implementation of a 5 kW photovoltaic system with li-ion battery and additional DC-DC converter T2 - 2010 IEEE Energy Conversion Congress and Exposition (ECCE 2010) : Atlanta, Georgia, USA, 12 - 16 September 2010 / [sponsored by the IEEE Power Electronics and Industry Applications Societies] Y1 - 2010 SN - 978-1-4244-5286-6 (Print) SN - 978-1-4244-5287-3 (Online) U6 - https://doi.org/10.1109/ECCE.2010.5618220 SP - 2944 EP - 2949 PB - IEEE CY - Piscataway, NJ ER - TY - JOUR A1 - Beer, S. A1 - Streun, M. A1 - Hombach, T. A1 - Buehler, J. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants JF - Physics in Medicine and Biology N2 - Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements. Y1 - 2010 U6 - https://doi.org/10.1088/0031-9155/55/3/006 SN - 1361-6560 VL - 55 IS - 3 SP - 635 EP - 646 PB - IOP CY - Bristol ER - TY - JOUR A1 - Funke, Harald A1 - Robinson, A. E. A1 - Hendrick, P. A1 - Wagemakers, R. T1 - Design and Testing of a Micromix Combustor With Recuperative Wall Cooling for a Hydrogen Fuelled µ-Scale Gas Turbine JF - Proceedings of the ASME Turbo Expo 2010 : presented at the 2010 ASME Turbo Expo, June 14 - 18, 2010, Glasgow, UK / sponsored by the International Gas Turbine Institute / Vol. 5: Industrial and cogeneration ; microturbines and small turbomachinery ; oil and gas applications ; wind turbine technology Y1 - 2010 SN - 978-0-7918-4400-7 N1 - GT2010-23453 ; ASME Turbo Expo ; (Glasgow) : 2010.06.14-18 SP - 587 EP - 596 PB - ASME CY - New York, NY ER - TY - JOUR A1 - Niemüller, Tim A1 - Ferrein, Alexander A1 - Beck, Daniel A1 - Lakemeyer, Gerhard T1 - Design Principles of the Component-Based Robot Software Framework Fawkes JF - Simulation, Modeling, and Programming for Autonomous Robots Y1 - 2010 N1 - Lecture Notes in Computer Science ; 6472 ; Second International Conference, SIMPAR 2010, Darmstadt, Germany, November 15-18, 2010. Proceedings SP - 300 EP - 311 ER - TY - CHAP A1 - Uibel, Thomas A1 - Blaß, Hans Joachim ED - Cecotti, A. T1 - Determining Suitable Spacings and Distances for Self-tapping Screws by Experimental and Numerical Studies T2 - Proceedings of the 11th World Conference on Timber Engineering, WCTE 2010 : World Conference on Timber Engineering; [June 20 - 24, 2010, Riva del Garda, Trento, Italy] . Vol. III, Riva del Garda, Italy 2010 Y1 - 2010 N1 - Extended abstract. Full paper: DVD, Session 55, ID 108, 9 Seiten SP - 669 EP - 670 ER - TY - CHAP A1 - Buck, R. A1 - Wurmhöringer, K. A1 - Lehle, R. A1 - Pfahl, A. A1 - Göttsche, Joachim A1 - Meyr, T. T1 - Development of a 30m2 heliostat with hydraulic drive T2 - SolarPACES 2010 : the CSP Conference: electricity, fuels and clean water from concentrated solar energy ; 21 to 24 September 2010, Perpignan, France Y1 - 2010 SP - 74 EP - 75 PB - Soc. OSC CY - Saint Maur ER - TY - JOUR A1 - Reisert, Steffen A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schäfer, Daniel A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Schöning, Michael Josef T1 - Development of a handheld sensor system for the online measurement of hydrogen peroxide in aseptic filling systems JF - Physica Status Solidi (A) N2 - A handheld sensor system for the online measurement of hydrogen peroxide (H2O2) in aseptic sterilisation processes has been developed. It is based on a calorimetric-type gas sensor that consists of a differential set-up of two temperature sensors, of which one is catalytically activated and the second one is passivated and used as reference. The sensor principle relies in detecting a rise in temperature on the active sensor due to the exothermic reaction of H2O2 on the catalytic surface. To characterise the sensor system towards H2O2 sensitivity and other influencing factors, measurements have been carried out both at an experimental set-up and a manufacturer's sterilisation machine. Physical sensor characterisation was done by means of the optical microscopy. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983304 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 913 EP - 918 PB - Wiley-VCH CY - Berlin ER - TY - CHAP A1 - Reimer, Lars A1 - Braun, Carsten A1 - Wellmer, Georg A1 - Behr, Marek A1 - Ballmann, Josef T1 - Development of a modular method for computational aero-structural analysis of aircraft T2 - Summary of flow modulation and fluid-structure interaction findings. Results of the Collaborative Research Center SFB 401 at the RWTH Aachen University, Aachen, Germany, 1997-2008 / ed.: Wolfgang Schröder. Notes on numerical fluid mechanics and multidisciplinary design. Vol. 109 Y1 - 2010 SN - 978-3-642-04087-0 SP - 205 EP - 238 PB - Springer CY - Berlin ER -