TY - JOUR A1 - Schopp, Christoph A1 - Doll, Timo A1 - Gräser, Ulrich A1 - Harzheim, Thomas A1 - Heuermann, Holger A1 - Kling, Rainer A1 - Marso, Michael T1 - Capacitively Coupled High-Pressure Lamp Using Coaxial Line Networks JF - IEEE Transactions on Microwave Theory and Techniques N2 - This paper describes the development of a capacitively coupled high-pressure lamp with input power between 20 and 43 W at 2.45 GHz, using a coaxial line network. Compared with other electrodeless lamp systems, no cavity has to be used and a reduction in the input power is achieved. Therefore, this lamp is an alternative to the halogen incandescent lamp for domestic lighting. To serve the demands of domestic lighting, the filling of the lamp is optimized over all other resulting requirements, such as high efficacy at low induced powers and fast startups. A workflow to develop RF-driven plasma applications is presented, which makes use of the hot S-parameter technique. Descriptions of the fitting process inside a circuit and FEM simulator are given. Results of the combined ignition and operation network from simulations and measurements are compared. An initial prototype is built and measurements of the lamp's lighting properties are presented along with an investigation of the efficacy optimizations using large signal amplitude modulation. With this lamp, an efficacy of 135 lmW -1 is achieved. Y1 - 2016 U6 - https://doi.org/10.1109/TMTT.2016.2600326 SN - 0018-9480 VL - 64 IS - 10 SP - 3363 EP - 3368 PB - IEEE CY - New York, NY ER - TY - JOUR A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Frauenrath, Tobias A1 - Prothmann, Marcel A1 - Dieringer, Matthias A. A1 - Hezel, Fabian A1 - Renz, Wolfgang A1 - Kretschel, Kerstin A1 - Niendorf, Thoralf A1 - Schulz-Menger, Jeanette T1 - Cardiac chamber quantification using magnetic resonance imaging at 7 Tesla—a pilot study N2 - Objectives Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T. Methods A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated. Results All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm. Conclusions This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T. Y1 - 2010 U6 - https://doi.org/10.1007/s00330-010-1888-2 SN - 0938-7994 VL - 20 SP - 2844 EP - 2852 PB - Springer CY - Berlin, Heidelberg ER - TY - GEN A1 - Lindel, Tomasz Dawid A1 - Greiser, Andreas A1 - Waxman, Patrick A1 - Dietterle, Martin A1 - Seifert, Frank A1 - Fontius, Ulrich A1 - Renz, Wolfgang A1 - Dieringer, Matthias A. A1 - Frauenrath, Tobias A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf A1 - Ittermann, Bernd T1 - Cardiac CINE MRI at 7 T using a transmit array T2 - 2012 ISMRM Annual Meeting Proceedings N2 - With its need for high SNR and short acquisition times, Cardiac MRI (CMR) is an intriguing target application for ultrahigh field MRI. Due to the sheer size of the upper torso, however, the known RF issues of 7T MRI are also most prominent in CMR. Recent years brought substantial progress but the full potential of the ultrahigh field for CMR is yet to be exploited. Parallel transmission (pTx) is a promising approach in this context and several groups have already reported B1 shimming for 7T CMR. In such a static pTx application amplitudes and phases of all Tx channels are adjusted individually but otherwise imaging techniques established in current clinical practice 1.5 T and 3 T are applied. More advanced forms of pTx as spatially selective excitation (SSE) using Transmit SENSE promise additional benefits like faster imaging with reduced fields of view or improved SAR control. SSE requires the full dynamic capabilities of pTx, however, and for the majority of today's implemented pTx hardware the internal synchronization of the Tx array does not easily permit external triggering as needed for CMR. Here we report a software solution to this problem and demonstrate the feasibility of CINE CMR at 7 T using a Tx array. Y1 - 2012 SN - 1545-4428 N1 - ISMRM 20th Annual Meeting & Exhibition, 5-11 May 2012, Melbourne, Australia ER - TY - GEN A1 - Tkachenko, Valeriy A1 - von Knobelsdorff-Brenkenhoff, Florian A1 - Kleindienst, Denise A1 - Winter, Lukas A1 - Rieger, Jan A1 - Frauenrath, Tobias A1 - Dieringer, Matthias A. A1 - Santoro, Davide A1 - Niendorf, Thoralf A1 - Schulz-Menger, Jeanette T1 - Cardiovasular MR at 7Tesla: assessment of the right ventricle T2 - 2012 ISMRM Annual Meeting Proceedings N2 - The assessment of the right ventricle (RV) is a challenge in today's cardiology, but of growing clinical impact regarding patient prognosis in different cardiac diseases. The detection and differentiation of small wall motion abnormalities may help to enhance the differentiation of cardiomyopathies including Arrhythmogenic Rightventricular Cardiomyopathy. Cardiovascular magnetic resonance (CMR) at 1.5T is the accepted gold standard for RV quantification. The higher spatial resolution achievable at ultrahigh field strength (UHF) offers the potential to gain new insights into the structure and function of the RV. To approach this goal accurate RV chamber quantification at 7T has to be proven. Consequently this study examines the feasibility of assessment of RV dimensions and function at 7T using improved spatial resolution enabled by the intrinsic sensitivity gain of UHF CMR. For this purpose, a dedicated 16 channel TX/RX RF coil array is used together with 2D CINE fast gradient echo (FGRE) imaging. For comparison RV chamber quantification is conducted at 1.5T using a SSFP based state of the art clinical protocol. Y1 - 2012 SN - 1545-4428 N1 - ISMRM 20th Annual Meeting & Exhibition, 5-11 May 2012, Melbourne, Australia ER - TY - PAT A1 - Nötzold, K. A1 - Bragard, Michael A1 - Fink, K. A1 - Griessel, R. A1 - Wegener, R. T1 - Cascaded H-bridge converter with transformer based cell power balancing in each voltage level : [Patentschrift] Y1 - 2014 N1 - Titel des US-Patents: Bypassed cascaded cell converter : [patent of invention]. - Außerdem veröffentlicht als CN103997231 (A) PB - Europäisches Patentamt / United States Patent and Trademark Office [u.a.] CY - Den Haag / Alexandria, VA ER - TY - CHAP A1 - Schiffer, Fabian A1 - Bragard, Michael T1 - Cascaded LQ and Field-Oriented Control of a Mobile Inverse Pendulum (Segway) with Permanent Magnet Synchronous Machines T2 - 2019 20th International Conference on Research and Education in Mechatronics (REM) Y1 - 2019 SN - 978-1-5386-9257-8 U6 - https://doi.org/10.1109/REM.2019.8744101 SP - 1 EP - 8 ER - TY - JOUR A1 - Hagemann, Hans-Jürgen A1 - Hennings, D. A1 - Wernicke, R. T1 - Ceramic multilayer capacitors. Hagemann, H. J.; Hennings, D.; Wernicke, R. JF - Philips' technical review / Philips' Gloeilampenfabrieken. Philips' Gloeilampenfabrieken . 41 (1984) Y1 - 1984 SN - 0031-7926 SP - 89 EP - 98 ER - TY - JOUR A1 - Haag, S. A1 - Zontar, D. A1 - Schleupen, Josef A1 - Müller, T. A1 - Brecher, C. T1 - Chain of refined perception in self-optimizing assembly of micro-optical systems JF - Journal of sensors and sensor systems N2 - Today, the assembly of laser systems requires a large share of manual operations due to its complexity regarding the optimal alignment of optics. Although the feasibility of automated alignment of laser optics has been shown in research labs, the development effort for the automation of assembly does not meet economic requirements – especially for low-volume laser production. This paper presents a model-based and sensor-integrated assembly execution approach for flexible assembly cells consisting of a macro-positioner covering a large workspace and a compact micromanipulator with camera attached to the positioner. In order to make full use of available models from computer-aided design (CAD) and optical simulation, sensor systems at different levels of accuracy are used for matching perceived information with model data. This approach is named "chain of refined perception", and it allows for automated planning of complex assembly tasks along all major phases of assembly such as collision-free path planning, part feeding, and active and passive alignment. The focus of the paper is put on the in-process image-based metrology and information extraction used for identifying and calibrating local coordinate systems as well as the exploitation of that information for a part feeding process for micro-optics. Results will be presented regarding the processes of automated calibration of the robot camera as well as the local coordinate systems of part feeding area and robot base. Y1 - 2014 U6 - https://doi.org/10.5194/jsss-3-87-2014 SN - 2194-878X VL - 3 IS - 1 SP - 87 EP - 95 PB - Copernicus Publ. CY - Göttingen ER - TY - JOUR A1 - Serror, Martin A1 - Hack, Sacha A1 - Henze, Martin A1 - Schuba, Marko A1 - Wehrle, Klaus T1 - Challenges and Opportunities in Securing the Industrial Internet of Things JF - IEEE Transactions on Industrial Informatics Y1 - 2021 U6 - https://doi.org/10.1109/TII.2020.3023507 SN - 1941-0050 VL - 17 IS - 5 SP - 2985 EP - 2996 PB - IEEE CY - New York ER - TY - JOUR A1 - Scholl, Ingrid A1 - Aach, Til A1 - Deserno, Thomas M. A1 - Kuhlen, Torsten T1 - Challenges of medical image processing JF - Computer Science - Research and Development Y1 - 2011 SN - 1865-2042 VL - 26 IS - 1-2 SP - 5 EP - 13 PB - Springer CY - Berlin ER - TY - JOUR A1 - Holtrup, S. A1 - Sadeghfam, Arash A1 - Heuermann, Holger A1 - Awakowicz, P. T1 - Characterization and optimization technique for microwave-driven high-intensity discharge lamps using hot S-parameters JF - IEEE transactions on microwave theories and techniques N2 - High-intensity discharge lamps can be driven by radio-frequency signals in the ISM frequency band at 2.45 GHz, using a matching network to transform the impedance of the plasma to the source impedance. To achieve an optimal operating condition, a good characterization of the lamp in terms of radio frequency equivalent circuits under operating conditions is necessary, enabling the design of an efficient matching network. This paper presents the characterization technique for such lamps and presents the design of the required matching network. For the characterization, a high-intensity discharge lamp was driven by a monofrequent large signal at 2.45 GHz, whereas a frequency sweep over 300 MHz was performed across this signal to measure so-called small-signal hot S-parameters using a vector network analyzer. These parameters are then used as an equivalent load in a circuit simulator to design an appropriate matching network. Using the measured data as a black-box model in the simulation results in a quick and efficient method to simulate and design efficient matching networks in spite of the complex plasma behavior. Furthermore, photometric analysis of high-intensity discharge lamps are carried out, comparing microwave operation to conventional operation. Y1 - 2014 U6 - https://doi.org/10.1109/TMTT.2014.2342652 SN - 0018-9480 VL - 62 IS - 10 SP - 2471 EP - 2480 PB - IEEE CY - New York ER - TY - CHAP A1 - Buxbaum, Bernd A1 - Schwarte, Rudolf A1 - Xu, Zhanping A1 - Ringbeck, Thorsten A1 - [u.a.], T1 - Charge Transfer Simulation in PMD-Structures T2 - Sensor 99 : proceedings / 9th Int'l Fair and Conference for Sensors, Transducers & Systems, May 18 - 20, 1999, Exhibition Centre Nürnberg/Germany. - Vol. 2 Y1 - 1999 N1 - International Fair and Conference for Sensors, Transducers and Systems <9, 1999, Nürnberg> ; Internationale Messe mit Kongress für Sensoren, Messaufnehmer und Systeme <9, 1999, Nürnberg> SP - 427 EP - 432 PB - AMA Service GmbH CY - Wunsdorf ER - TY - JOUR A1 - Prume, Klaus A1 - Tyholdt, F. A1 - Calame, F. A1 - Raeder, H. T1 - Chemically derived seeding layer for {100}-textured PZT thin films / Tyholdt, F. ; Calame, F. ; Prume, K. ; Raeder, H. ; Muralt, P. JF - Journal of Electroceramics. 19 (2007), H. 4 Y1 - 2007 SN - 1385-3449 SP - 311 EP - 314 ER - TY - JOUR A1 - Siepmann, Thomas A1 - Rupietta, D. T1 - Closer to the customer with computerized product support JF - Technische Mitteilungen Krupp (1993) Y1 - 1993 CY - Essen ER - TY - CHAP A1 - Dey, Thomas A1 - Elsen, Ingo A1 - Ferrein, Alexander A1 - Frauenrath, Tobias A1 - Reke, Michael A1 - Schiffer, Stefan ED - Makedon, Fillia T1 - CO2 Meter: a do-it-yourself carbon dioxide measuring device for the classroom T2 - PETRA '21: Proceedings of the 14th Pervasive Technologies Related to Assistive Environments Conference N2 - In this paper we report on CO2 Meter, a do-it-yourself carbon dioxide measuring device for the classroom. Part of the current measures for dealing with the SARS-CoV-2 pandemic is proper ventilation in indoor settings. This is especially important in schools with students coming back to the classroom even with high incidents rates. Static ventilation patterns do not consider the individual situation for a particular class. Influencing factors like the type of activity, the physical structure or the room occupancy are not incorporated. Also, existing devices are rather expensive and often provide only limited information and only locally without any networking. This leaves the potential of analysing the situation across different settings untapped. Carbon dioxide level can be used as an indicator of air quality, in general, and of aerosol load in particular. Since, according to the latest findings, SARS-CoV-2 can be transmitted primarily in the form of aerosols, carbon dioxide may be used as a proxy for the risk of a virus infection. Hence, schools could improve the indoor air quality and potentially reduce the infection risk if they actually had measuring devices available in the classroom. Our device supports schools in ventilation and it allows for collecting data over the Internet to enable a detailed data analysis and model generation. First deployments in schools at different levels were received very positively. A pilot installation with a larger data collection and analysis is underway. KW - embedded hardware KW - sensor networks KW - information systems KW - education KW - do-it-yourself Y1 - 2021 SN - 9781450387927 U6 - https://doi.org/10.1145/3453892.3462697 N1 - PETRA '21: The 14th PErvasive Technologies Related to Assistive Environments Conference Corfu Greece 29 June 2021- 2 July 2021 SP - 292 EP - 299 PB - Association for Computing Machinery CY - New York ER - TY - JOUR A1 - Hartung, Frank A1 - Horn, U. T1 - Codierung digitaler Videosignale nach dem MPEG-Standard / Hartung, F. ; Horn, U. JF - Mikroelektronik + Mikrosystemtechnik. 9 (1995) Y1 - 1995 N1 - gedruckte Ausgabe in der Bereichsbibliothek Jülich vorhanden SP - 18 EP - 23 ER - TY - CHAP A1 - Steinbauer, Gerald A1 - Ferrein, Alexander T1 - CogRob 2018 : Cognitive Robotics Workshop. Proceedings of the 11th Cognitive Robotics Workshop 2018 co-located with 16th International Conference on Principles of Knowledge Representation and Reasoning (KR 2018). Tempe, AZ, USA, October 27th, 2018. T2 - CEUR workshop proceedings Y1 - 2019 SN - 1613-0073 N1 - edited by Gerald Steinbauer, Alexander Ferrein IS - Vol-2325 ER - TY - CHAP A1 - Lindenlauf, Simon A1 - Höfken, Hans-Wilhelm A1 - Schuba, Marko T1 - Cold Boot Attacks on DDR2 and DDR3 SDRAM T2 - 10th International Conference on Availability, Reliability and Security (ARES) 2015 Y1 - 2015 U6 - https://doi.org/10.1109/ARES.2015.28 SP - 287 EP - 292 ER - TY - JOUR A1 - Hagemann, Hans-Jürgen A1 - Backhaus, U. A1 - Goessner, S. T1 - Collaborative eLearning Concepts for University Level Online Laboratory Courses in Engineering. U. Backhaus, S. Goessner, H. J. Hagemann JF - Proceedings Online Educa Berlin: 8th International Conference on Technology Supported Learning & Training. 2002 Y1 - 2002 N1 - Online Educa <2002, Berlin> SP - 62 EP - 66 ER - TY - CHAP A1 - Bitz, Andreas A1 - Alaydrus, M. A1 - Streckert, J. A1 - Hansen, V. T1 - Combination of the hybrid/sup [2]/-method and the FDTD-method for solution of boundary value problems with electrically large and high-resolution bodies T2 - IEEE Antennas and Propagation Society International Symposium (IEEE Cat. No.02CH37313) 2002 : San Antonio, TX, USA, 16-21 June Y1 - 2002 SN - 0-7803-7330-8 U6 - https://doi.org/10.1109/APS.2002.1018209 SP - 278 EP - 281 PB - IEEE CY - Piscataway, NJ ER -