TY - CHAP A1 - Butenweg, Christoph A1 - Holtschoppen, Britta T1 - Seismic design of industrial facilities in Germany T2 - Seismic Design of Industrial Facilities : proceedings of the International Conference on Seismic Design of Industrial Facilities (SeDIF-Conference) : Aachen, 26. - 27.9.2013 Y1 - 2014 SN - 978-3-658-02809-1 ; 3-658-02809-2 (Print) ; 978-3-658-02810-7 (E-Book) U6 - https://doi.org/10.1007/978-3-658-02810-7_6 SP - 63 EP - 74 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Vogt, C. A1 - Mottaghy, Darius A1 - Rath, V. A1 - Marquart, G. A1 - Dijkshoorn, L. A1 - Wolf, A. A1 - Clauser, C. T1 - Vertical variation in heat flow on the Kola Peninsula: palaeoclimate or fluid flow? JF - Geophysical Journal International N2 - Following earlier studies, we present forward and inverse simulations of heat and fluid transport of the upper crust using a local 3-D model of the Kola area. We provide best estimates for palaeotemperatures and permeabilities, their errors and their dependencies. Our results allow discriminating between the two mentioned processes to a certain extent, partly resolving the non-uniqueness of the problem. We find clear indications for a significant contribution of advective heat transport, which, in turn, imply only slightly lower ground surface temperatures during the last glacial maximum relative to the present value. These findings are consistent with the general background knowledge of (i) the fracture zones and the corresponding fluid movements in the bedrock and (ii) the glacial history of the Kola area. Y1 - 2014 U6 - https://doi.org/10.1093/gji/ggu282 SN - 1365-246X VL - 199 IS - 2 SP - 829 EP - 843 PB - Oxford University Press CY - Oxford ER - TY - JOUR A1 - Rath, V. A1 - Mottaghy, Darius T1 - Klimainformation aus dem Untergrund? JF - Geographische Rundschau Y1 - 2014 SN - 0016-7460 VL - 66 IS - 7-8 SP - 30 EP - 36 PB - Westermann CY - Braunschweig ER - TY - JOUR A1 - Kürten, Sylvia A1 - Mottaghy, Darius A1 - Ziegler, Martin T1 - Planung, Auslegung und Dimensionierung von thermo-aktiven Bauteilen am Beispiel thermo-aktiver Abdichtungselemente JF - Geothermie, Bohr- und Brunnentechnik Y1 - 2014 SP - 18 EP - 20 PB - Ernst & Sohn CY - Berlin ER - TY - CHAP A1 - Borchert, Jörg A1 - Bremen, Frank T1 - Geschäfts- und Organisationsmodelle für ein Strom- und Gas-Portfoliomanagement T2 - Optimierte Strom- und Gasbeschaffung in der Energiewirtschaftsbranche Y1 - 2014 SN - 978-3-9813142-9-8 SP - 11 EP - 28 PB - KS-Energy-Verl. CY - Berlin ER - TY - CHAP A1 - Goldbach, Daniel ED - Wahl, Michael T1 - Diagnosemaßnahmen im Umfeld der Funktionalen Sicherheit T2 - AmE 2014 - Automotive meets electronics [Elektronische Ressource] : Beiträge der 5. GMM-Fachtagung vom 18. bis 19. Februar 2014 in Dortmund / Veranst.: VDE/VDI-Gesellschaft Mikroelektronik, Mikrosystem- und Feinwerktechnik (GMM) Y1 - 2014 SN - 978-3-8007-3580-8 N1 - GMM-Fachbericht ; 78 SP - 172 EP - 179 PB - VDE-Verl. CY - Berlin ER - TY - CHAP A1 - Kern, Alexander A1 - Braun, Christian T1 - Risk management according to IEC 62305-2 edition 2: 2010–12 assessment of structures with a risk of explosion T2 - 2014 International Conference on Lightning Protection (ICLP), Shanghai, China N2 - Risk management for structures with a risk of explosion should be considered very carefully when performing a risk analysis according to IEC 62305-2. In contrast to the 2006 edition of the standard, the 2010 edition describes the topic “Structures with a risk of explosion” in more detail. Moreover, in Germany separate procedures and parameters are defined for the risk analysis of structures with a risk of explosion (Supplement 3 of the German DIN EN 62305-2 standard). This paper describes the contents and the relevant calculations of this Supplement 3, together with a numerical example. Y1 - 2014 SP - 1237 EP - 1242 ER - TY - CHAP A1 - Rousseau, Alain A1 - Kern, Alexander T1 - How to deal with environmental risk in IEC 62305-2 T2 - 2014 International Conference on Lightning Protection (ICLP), Shanghai, China N2 - The 2nd edition of the lightning risk management standard (IEC 62305-2) considers structures, which may endanger environment. In these cases, the loss is not limited to the structure itself, which is valid for usual structures. In the past (Edition 1) this danger was simply taken into account by a special hazard factor, multiplying the existing risk for the structure with a number. Now, in the edition 2, we add to the risk for the structure itself a “second risk” due to the losses outside the structure. The losses outside can be treated independently from what occurs inside. This is a major advantage to analyze the risk for sensitive structures, like chemical plants, nuclear plants, or structures containing explosives, etc. In this paper, the existing procedure given by the European version EN 62305-2 Ed.2 is further developed and applied to a few structures. Y1 - 2014 SP - 521 EP - 527 ER - TY - CHAP A1 - Hellmanns, Mark A1 - Fischer, F. A1 - Dilger, K. A1 - Wittor, B. A1 - Hildebrand, J. A1 - Werner, F. T1 - Applikation und Einsatz von faserverstärkten Klebstoffen im Bauwesen abgeschlossenes IGF-Projekt Nr. 16956 B (DVS 08.072, Laufzeit 01.02.2011 - 31.01.2013) T2 - Tagungsband / 14. Kolloquium Gemeinsame Forschung in der Klebtechnik : 18. und 19. Februar 2014, DECHEMA-Haus, Frankfurt am Main Y1 - 2014 SP - 26 EP - 27 ER - TY - BOOK A1 - Kern, Alexander A1 - Wettingfeld, Jürgen T1 - Blitzschutzsysteme 1 : allgemeine Grundsätze, Risikomanagement, Schutz von baulichen Anlagen und Personen ; Erläuterungen zu den Normen DIN EN 62305-1 (VDE 0185-305-1):2011-10, DIN EN 62305-2 (VDE 0185-305-2):2013-02, DIN EN 62305-3 (VDE 0185-305-3):2011-10. (VDE-Schriftenreihe Normen verständlich ; 44) Y1 - 2014 SN - 978-3-8007-3511-2 PB - VDE-Verl. CY - Berlin [u.a.] ER -