TY - CHAP A1 - Alexopoulos, Spiros A1 - Hoffschmidt, Bernhard A1 - Rau, Christoph A1 - Sattler, Johannes Christoph T1 - Choice of solar share of a hybrid power plant of a central receiver system and a biogas plant in dependency of the geographical latitude T2 - World Renewable Energy Congress-Sweden : 8 -13 May, 2011, Linköping, Sweden / ed.: Bahram Moshfegh Y1 - 2011 SN - 9789173930703 SP - 3710 EP - 3717 PB - Univ. Electronic Pr. CY - Linköping ER - TY - JOUR A1 - Digel, Ilya T1 - Primary thermosensory events in cells JF - Transient receptor potential channels / Md. Shahidul Islam, ed. Y1 - 2011 SN - 978-94-007-0264-6 N1 - (Advances in experimental medicine and biology ; 704) SP - 451 EP - 468 PB - Springer CY - Dordrecht [u.a.] ER - TY - CHAP A1 - Thenent, N. E. A1 - Dahmann, Peter T1 - Increasing aircraft design flexibility ‐ The development of a hydrostatic transmission for gliders with self‐launching capability T2 - Deutscher Luft- und Raumfahrtkongress 2011 : Bremen, 27. bis 29. September 2011 ; Tagungsband Y1 - 2011 SN - 978-3-9321-8274-7 SP - 865 EP - 883 PB - Dt. Gesellschaft für Luft- und Raumfahrt CY - Bonn ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Werner, Moritz A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Capacitance–voltage and impedance-spectroscopy characteristics of nanoplate EISOI capacitors JF - Physica status solidi (a) : applications and material science. 208 (2011), H. 6 Y1 - 2011 SN - 1862-6319 SP - 1327 EP - 1332 PB - Wiley-VCH CY - Berlin ER - TY - CHAP A1 - Artmann, Gerhard A1 - Digel, Ilya A1 - Linder, Peter A1 - Temiz Artmann, Aysegül T1 - Biophysical and Engineering Contributions to Plant Research N2 - Tests with palm tree leaves have just started yet and scan data are in the process to be analyzed. The final goal of future project for palm tree gender and species recognition will be to develop optical scanning technology to be applied to date palm tree leaves for in–situ screening purposes. Depending on the software used and the particular requirements of the users the technology potentially shall be able to identify palm tree diseases, palm tree gender, and species of young date palm trees by scanning leaves. KW - Pflanzenphysiologie KW - Dattel KW - Pflanzenscanner KW - plant scanner KW - date palm tree Y1 - 2011 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Malzahn, K. A1 - Abouzar, Maryam H. A1 - Mehndiratta, P. A1 - Katz, E. A1 - Schöning, Michael Josef T1 - Integration of biomolecular logic gates with field-effect transducers JF - Electrochimica Acta. 56 (2011), H. 26 Y1 - 2011 SN - 0013-4686 SP - 9661 EP - 9665 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Seifarth, Volker A1 - Schehl, D. A1 - Linder, Peter A1 - Gossmann, Matthias A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Porst, Dariusz A1 - Preiß, C. A1 - Kayser, Peter A1 - Pack, O. A1 - Temiz Artmann, Aysegül T1 - Ureplace: development of a bioreactor for in vitro culturing of cell seeded tubular vessels on collagen scaffolds N2 - The demand of replacements for inoperable organs exceeds the amount of available organ transplants. Therefore, tissue engineering developed as a multidisciplinary field of research for autologous in-vitro organs. Such three dimensional tissue constructs request the application of a bioreactor. The UREPLACE bioreactor is used to grow cells on tubular collagen scaffolds OPTIMAIX Sponge 1 with a maximal length of 7 cm, in order to culture in vitro an adequate ureter replacement. With a rotating unit, (urothelial) cells can be placed homogeneously on the inner scaffold surface. Furthermore, a stimulation is combined with this bioreactor resulting in an orientation of muscle cells. These culturing methods request a precise control of several parameters and actuators. A combination of a LabBox and the suitable software LabVision is used to set and conduct parameters like rotation angles, velocities, pressures and other important cell culture values. The bioreactor was tested waterproof successfully. Furthermore, the temperature controlling was adjusted to 37 °C and the CO2 - concentration regulated to 5 %. Additionally, the pH step responses of several substances showed a perfect functioning of the designed flow chamber. All used software was tested and remained stable for several days. KW - Tissue Engineering KW - Bioreaktor KW - Organkultur KW - Harnleiter Y1 - 2011 ER - TY - CHAP A1 - Bung, Daniel Bernhard T1 - Non-intrusive measuring of air-water flow properties in self-aerated stepped spillway flow T2 - Balance and uncertainty - water in a changing world : proceedings of the 34th IAHR world congress ; 33rd Hydrology and Water Resources Symposium ; 10th Conference on Hydraulics in Water Engineering ; 26 June - 1 July 2011, Brisbane, Australia Y1 - 2011 SN - 978-0-85825-868-6 SP - 2380 EP - 2387 ER - TY - JOUR A1 - Bäcker, Matthias A1 - Delle, L. A1 - Poghossian, Arshak A1 - Biselli, Manfred A1 - Zang, Werner A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - Electrochemical sensor array for bioprocess monitoring JF - Electrochimica Acta (2011) Y1 - 2011 VL - 56 IS - 26 SP - 9673 EP - 9678 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schiffer, Stefan A1 - Ferrein, Alexander A1 - Lakemeyer, Gerhard T1 - Reasoning with Qualitative Positional Information for Domestic Domains in the Situation Calculus JF - Journal of Intelligent & Robotic Systems Y1 - 2011 SN - 0921-0296 VL - 63 IS - 2 SP - 273 EP - 300 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kurulgan Demirci, Eylem A1 - Demirci, T. A1 - Trzewik, Jürgen A1 - Linder, Peter A1 - Karakulah, G. A1 - Artmann, Gerhard A1 - Sakizli, M. A1 - Temiz Artmann, Aysegül T1 - Genome-Wide Gene Expression Analysis of NIH 3T3 Cell Line Under Mechanical Stimulation JF - Cellular and molecular bioengineering. 4 (2011), H. 1 Y1 - 2011 SN - 1865-5025 SP - 46 EP - 55 PB - Springer CY - Berlin ER - TY - CHAP A1 - Achenbach, Timm A1 - Geimer, K. A1 - Göttsche, Joachim A1 - Hoffschmidt, Bernhard A1 - Lynen, A. A1 - Bauer, J. T1 - Simulation and flow measurements of volumetric high temperature absorbers for solar tower power plants T2 - SolarPACES 2011 : concentrating solar power and chemical energy systems : 20 - 23 September, 2011, Granada, Spain Y1 - 2011 CY - Granada ER - TY - CHAP A1 - Teixeira Boura, Cristiano José A1 - Eckstein, J. A1 - Felinks, J. A1 - Göttsche, Joachim A1 - Hoffschmidt, Bernhard A1 - Schmitz, S. T1 - 3-D CFD simulation of an air-sand heat exchanger T2 - SolarPACES 2011 : concentrating solar power and chemical energy systems : 20 - 23 September, 2011, Granada, Spain Y1 - 2011 CY - Granada ER - TY - CHAP A1 - Achenbach, Timm A1 - Göttsche, Joachim A1 - Kaufhold, O. A1 - Hoffschmidt, Bernhard T1 - Development of an edge module for open volumetric receiver for the use of the radiation at the receiver boundary region T2 - SolarPACES 2011 : concentrating solar power and chemical energy systems : 20 - 23 September, 2011, Granada, Spain Y1 - 2011 CY - Granada ER - TY - CHAP A1 - Alexopoulos, Spiros A1 - Hoffschmidt, Bernhard A1 - Rau, Christoph T1 - Comparison of steady-state and transient simulations for solar tower power plants with open-volumetric receiver T2 - SolarPACES 2011 : concentrating solar power and chemical energy systems : 20 - 23 September, 2011, Granada, Spain Y1 - 2011 CY - Granada ER - TY - JOUR A1 - Huck, Christina A1 - Jolly, Christina A1 - Wagner, Patrick A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - One-chip integrated dual amperometric/field-effect sensor for the detection of dissolved hydrogen JF - Procedia Engineering. 25 (2011) Y1 - 2011 SN - 1877-7058 N1 - EurosensorsXXV ; Proc. Eurosensors XXV, September 4-7, 2011, Athens, Greece SP - 1161 EP - 1164 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poth, Sebastian A1 - Monzon, Magaly A1 - Tippkötter, Nils A1 - Ulber, Roland T1 - Lignocellulosic biorefinery: Process integration of hydrolysis and fermentation (SSF process) JF - Holzforschung N2 - The aim of the present work is the process integration and the optimization of the enzymatic hydrolysis of wood and the following fermentation of the products to ethanol. The substrate is a fiber fraction obtained by organosolv pre-treatment of beech wood. For the ethanol production, a co-fermentation by two different yeasts (Saccharomyces cerevisiae and Pachysolen tannophilus) was carried out to convert glucose as well as xylose. Two approaches has been followed: 1. A two step process, in which the hydrolysis of the fiber fraction and the fermentation to product are separated from each other. 2. A process, in which the hydrolysis and the fermentation are carried out in one single process step as simultaneous saccharification and fermentation (SSF). Following the first approach, a yield of about 0.15 g ethanol per gram substrate can be reached. Based on the SSF, one process step can be saved, and additionally, the gained yield can be raised up to 0.3 g ethanol per gram substrate. Y1 - 2011 N1 - 11th EWLP, Hamburg, Germany, August 16–19, 2010 VL - 65 IS - 5 SP - 633 EP - 637 PB - De Gruyter CY - Berlin ER - TY - CHAP A1 - Muffler, Kai A1 - Poth, Sabastian A1 - Sieker, Tim A1 - Tippkötter, Nils A1 - Ulber, Roland A1 - Sell, Dieter ED - Moo-Young, Murray T1 - Bio-feedstocks T2 - Comprehensive biotechnology : principles and practices in industry, agcriculture, medicine and the environment. Volume 2: Engineering fundamentals of biotechnology Y1 - 2011 SN - 978-0-444-53352-4 U6 - https://doi.org/10.1016/B978-0-08-088504-9.00088-X SP - 93 EP - 101 PB - Elsevier CY - Amsterdam ET - 2. edition ER - TY - CHAP A1 - Helmig, Ilka T1 - Friendship : editorial illustration T2 - Papercraft 2 : design and art with paper KW - Papierkunst KW - Illustration Y1 - 2011 SN - 978-3-89955-333-8 SP - 237 PB - Gestalten Verlag CY - Berlin ER - TY - CHAP A1 - Fabo, Sabine ED - Schmidt, Sabine Maria T1 - REMOTEWORDS – anticipating the big observer T2 - Hacking the city : Interventionen in urbanen und kommunikativen Räumen ; Museum Folkwang, [16. Juli - 26. September 2010] KW - Streetart KW - Öffentlicher Raum KW - Stadtgestaltung KW - Aktionskunst KW - Kommunikationsguerrilla Y1 - 2011 SN - 978-3-86930-187-7 N1 - http://www.hackingthecity.org SP - 134 EP - 137 PB - Steidl ; Edition Folkwang CY - Göttingen [u.a.] ER - TY - GEN A1 - Martin, Conrad Steven A1 - Frauenrath, Tobias A1 - Zerdem, Celal A1 - Renz, Wolfgang A1 - Niendorf, Thoralf T1 - Evaluation of Magneto Alert Sensor (MALSE) to Improve MR Safety by Decreasing the Incidence of Ferromagnetic Projectile Accidents T2 - 2011 ISMRM Annual Meeting Proceedings N2 - The magnetic forces of fringe magnetic fields of MR systems on ferromagnetic components can impose a severe patient, occupational health and safety hazard. MRI accidents are listed as number 9 of the top 10 risks in modern medicine. With the advent of ultrahigh field MR systems including passively shielded magnet versions, this risk, commonly known as the missile or projectile effect is even more pronounced. A strategy employing magnetic field sensors which can be attached to ferromagnetic objects that are commonly used in a clinical environment is conceptually appealing for the pursuit of reducing the risk of ferromagnetic projectile accidents. Y1 - 2011 SN - 1545-4428 N1 - ISMRM 19th Annual Meeting & Exhibition, 7-13 May 2011, Montreal, Quebec, Canada ER - TY - CHAP A1 - Bragard, Michael A1 - Ronge, C. A1 - De Doncker, R. W. T1 - Sandwich design of high-power thyristor based devices with integrated MOSFET structure T2 - Proceedings of the 2011 - 14th - European Conference on Power Electronics and Applications (EPE 2011) : Aug. 30, 2011 - Sept. 1, 2011, Birmingham, United Kingdom Y1 - 2011 SN - 978-1-61284-167-0 (Print) SN - 978-90-75815-15-3 (Online) PB - IEEE CY - Piscataway, NJ ER - TY - CHAP A1 - Bragard, Michael A1 - Gottschlich, J. A1 - De Doncker, R. W. T1 - Design and realization of a credit card size driver stage for high power thyristor based devices with integrated MOS structure T2 - 2011 IEEE 8th International Conference on Power Electronics and ECCE Asia (ICPE & ECCE 2011) : Jeju, South Korea, 30 May 2011 - 3 June 2011 / [co-sponsored by the Korean Institute of Power Electronics ...] Y1 - 2011 SN - 978-1-61284-958-4 (Print) SN - 978-1-61284-956-0 (Online) U6 - https://doi.org/10.1109/ICPE.2011.5944661 SP - 1182 EP - 1189 PB - IEEE CY - Piscataway, NJ ER - TY - JOUR A1 - Martin, Conrad A1 - Frauenrath, Tobias A1 - Özerdem, Celal A1 - Renz, Wolfgang A1 - Niendorf, Thoralf T1 - Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging JF - European Radiology N2 - Objective The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments. Methods MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR. Results The consistency with which individual reed sensors would activate at the same field strength was found to be 100% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated. Conclusions MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur. KW - MRI KW - MR safety KW - Magneto alert sensor KW - High field MRI KW - Uktrahigh field MRI Y1 - 2011 U6 - https://doi.org/10.1007/s00330-011-2153-z SN - 1432-1084 VL - 21 SP - 2187 EP - 2192 PB - Springer CY - Berlin, Heidelberg ER - TY - JOUR A1 - Dieringer, Matthias A. A1 - Renz, Wolfgang A1 - Lindel, Tomasz D. A1 - Seifert, Frank A1 - Frauenrath, Tobias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Waiczies, Helmar A1 - Hoffmann, Werner A1 - Rieger, Jan A1 - Pfeiffer, Harald A1 - Ittermann, Bernd A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Design and application of a four-channel transmit/receive surface coil for functional cardiac imaging at 7T JF - Journal of Magnetic Resonance Imaging N2 - Purpose To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T. Materials and Methods A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3. Results Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach. Conclusion A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated. Y1 - 2011 U6 - https://doi.org/10.1002/jmri.22451 SN - 1522-2586 VL - 33 IS - 3 SP - 736 EP - 741 PB - Wiley-Liss CY - New York ER - TY - GEN A1 - Frauenrath, Tobias A1 - Dieringer, Matthias A1 - Patel, Nishant A1 - Zerdem, Celal A1 - Hentschel, Jan A1 - Renz, Wolfgang A1 - Niendorf, Thoralf T1 - From Artifact to Merit: Cardiac Gated MRI at 7T & 3T using Magneto-Hydrodynamic Effects for Synchronization T2 - 2011 ISMRM Annual Meeting Proceedings N2 - ECG is corrupted by magneto-hydrodynamic effects at higher magnetic field strength. Artifacts in the ECG trace and severe T-wave elevation might be mis-interpreted as R-waves. MHD being inherently sensitive to blood flow and blood velocity provides an alternative approach for cardiac gating, even in peripheral target areas far away from the commonly used upper torso positions of ECG electrodes. This feature would be very beneficial to address traveling time induced motion artifacts and trigger latency related issues raised by ECG-gated peripheral MR angiography. For all those reasons, this work proposes the use of MHD-trigger for cardiac gated MR. Y1 - 2011 SN - 1545-4428 N1 - ISMRM 19th Annual Meeting & Exhibition, 7-13 May 2011, Montreal, Quebec, Canada ER - TY - CHAP A1 - Fuchs, Britta A1 - Ritz, Thomas A1 - Halbach, Bastian A1 - Hartl, Florian ED - Marca, David A. T1 - Blended shopping : interactivity and individualization T2 - Proceedings of the International Conference on e-Business : Seville, Spain, 18 - 21 July 2011 ; [... integrated in the ICETE (International Conference on e-Business and Telecommunications) joint conference] Y1 - 2011 SN - 978-989-8425-70-6 SP - 47 EP - 52 PB - SciTePress CY - [Lissabon] ER - TY - CHAP A1 - Hahn, Thomas A1 - Kelly, Svenja A1 - Muffler, Kai A1 - Tippkötter, Nils A1 - Ulber, Roland ED - Hans-Jörg, Bart ED - Pilz, Stephan T1 - Extraction of lignocellulose and algae for the production of bulk and fine chemicals T2 - Industrial scale natural products extraction Y1 - 2011 SN - 978-3-527-32504-7 (Print) SN - 978-3-527-63512-2 (Online) U6 - https://doi.org/10.1002/9783527635122 SP - 221 EP - 245 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Dachwald, Bernd A1 - Wurm, Patrick T1 - Mission analysis and performance comparison for an Advanced Solar Photon Thruster JF - Advances in Space Research Y1 - 2011 SN - 0273-1177 VL - 48 IS - 11 SP - 1858 EP - 1868 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Becker, Jörg A1 - Eggert, Mathias A1 - Winkelmann, Axel A1 - Knackstedt, Ralf T1 - Towards a Contingency Theory based Model of the Influence of Regulation on MIS T2 - Proceedings of the Seventeenth Americas Conference on Information Systems, Detroit, Michigan August 4th -7 th 2011 Y1 - 2011 ER - TY - JOUR A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül T1 - The emperor's new body : seeking for a blueprint of limb regeneration in humans JF - Stem cell engineering : principles and applications / Gerhard M. Artmann ... eds. Y1 - 2011 SN - 978-3-642-11864-7 SP - 3 EP - 37 PB - Springer CY - Berlin [u.a.] ER - TY - CHAP A1 - Thenent, N. E. A1 - Dahmann, Peter T1 - Hydrostatic propeller drive T2 - Proceedings of the conference : 18 - 20 May, 2011 Tampere, Finland / the Twelth Scandinavian International Conference on Fluid Power, SICFP'11. Ed.: Harri Sairiala ... Vol. 1 Y1 - 2011 SN - 978-952-15-2517-9 SP - 217 EP - 227 CY - Tampere ER - TY - JOUR A1 - Gasparyan, Ferdinand V. A1 - Poghossian, Arshak A1 - Vitusevich, Svetlana A. A1 - Petrychuk, Mykhaylo V. A1 - Sydoruk, Viktor A. A1 - Siqueira, José R. Jr. A1 - Oliveira, Osvaldo N. Jr. A1 - Offenhäusser, Andreas A1 - Schöning, Michael Josef T1 - Low-Frequency Noise in Field-Effect Devices Functionalized With Dendrimer/Carbon-Nanotube Multilayers JF - IEEE Sensors Journal. 11 (2011), H. 1 Y1 - 2011 SN - 1530-437X SP - 142 EP - 149 PB - IEEE CY - New York ER - TY - JOUR A1 - Gun, Jenny A1 - Gutkin, Vitaly A1 - Lev, Ovadia A1 - Boyen, Hans-Gerd A1 - Saitner, Marc A1 - Wagner, Patrick A1 - Olieslaeger, Marc D´ A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Tracing gold nanoparticle charge by electrolyte-insulator-semiconductor devices JF - Journal of Physical Chemistry C. 115 (2011), H. 11 Y1 - 2011 SN - 1932-7455 SP - 4439 EP - 4445 PB - American Cemical Society CY - Washington, DC ER - TY - JOUR A1 - Eilmann, Britta A1 - Zweifel, Roman A1 - Buchmann, Nina A1 - Graf Pannatier, Elisabeth A1 - Rigling, Andreas T1 - Drought alters timing, quantity, and quality of wood formation in Scots pine JF - Journal of Experimental Botany Y1 - 2011 U6 - https://doi.org/10.1093/jxb/erq443 SN - 1460-2431 (Online) SN - 0022-0957 (Print) VL - 62 IS - 8 SP - 2763 EP - 2771 PB - Oxford University Press CY - Oxford ER - TY - CHAP A1 - Damm, Sebastian A1 - Ritz, Thomas A1 - Strauch, Jakob T1 - Adaption of archetype patterns for mobile cloud-based business apps T2 - 2011 IEEE International Conference on Pervasive Computing and Communications workshops (PerCom workshops 2011) : Seattle, Washington, USA, 21 - 25 March 2011 Y1 - 2011 SN - 978-1-61284-938-6 (Print) SN - 978-1-61284-936-2 (E-Book) U6 - https://doi.org/10.1109/PERCOMW.2011.5766849 SP - 100 EP - 105 PB - IEEE Service Center CY - Piscataway, NJ ER - TY - GEN A1 - Frauenrath, Tobias A1 - de Geyer d'Orth, Thibaut A1 - Niendorf, Thoralf T1 - Assessment of Accuracy & Reproducibility of ECG, Pulse Oximetry & Phonocardiogram Gating of Cardiac MRI at 7T T2 - 2011 ISMRM Annual Meeting Proceedings N2 - At (ultra)high magnetic fields the artifact sensitivity of ECG recordings increases. This bears the risk of R-wave mis-registration which has been consistently reported for ECG triggered CMR at 7.0T. Realizing the constraints of conventional ECG, acoustic cardiac triggering (ACT) has been proposed. The clinical ACT has not been carefully examined yet. For this reason, this work scrutinizes the suitability, accuracy and reproducibility of ACT for CMR at 7.0T. For this purpose, the trigger reliability and trigger detection variance are examined together with an qualitative and quantitative assessment of image quality of the heart at 7.0T. Y1 - 2011 SN - 1545-4428 N1 - ISMRM 19th Annual Meeting & Exhibition, 7-13 May 2011, Montreal, Quebec, Canada ER - TY - JOUR A1 - Grinsven, Bart van A1 - Vanden Bon, Natalie A1 - Grieten, Lars A1 - Murib, Mohammed Sharif A1 - Janssen, Stoffel Dominique A1 - Haenen, Ken A1 - Schneider, E. A1 - Ingebrandt, Sven A1 - Schöning, Michael Josef A1 - Vermeeren, Veronique A1 - Ameloot, Marcel A1 - Michiels, Luc A1 - Thoelen, Ronald A1 - De Ceuninck, Ward A. A1 - Wagner, Patrick T1 - Rapid assessment of the stability of DNA duplexes by impedimetric real-time monitoring of chemically induced denaturation JF - Lab on a Chip Y1 - 2011 SN - 1473-0197 VL - 11 IS - 9 SP - 1656 EP - 1663 PB - Royal Society of Chemistry (RSC) CY - Cambridge ER - TY - JOUR A1 - Bialonski, Stephan A1 - Wendler, Martin A1 - Lehnertz, Klaus T1 - Unraveling spurious properties of interaction networks with tailored random networks JF - Plos one N2 - We investigate interaction networks that we derive from multivariate time series with methods frequently employed in diverse scientific fields such as biology, quantitative finance, physics, earth and climate sciences, and the neurosciences. Mimicking experimental situations, we generate time series with finite length and varying frequency content but from independent stochastic processes. Using the correlation coefficient and the maximum cross-correlation, we estimate interdependencies between these time series. With clustering coefficient and average shortest path length, we observe unweighted interaction networks, derived via thresholding the values of interdependence, to possess non-trivial topologies as compared to Erdös-Rényi networks, which would indicate small-world characteristics. These topologies reflect the mostly unavoidable finiteness of the data, which limits the reliability of typically used estimators of signal interdependence. We propose random networks that are tailored to the way interaction networks are derived from empirical data. Through an exemplary investigation of multichannel electroencephalographic recordings of epileptic seizures – known for their complex spatial and temporal dynamics – we show that such random networks help to distinguish network properties of interdependence structures related to seizure dynamics from those spuriously induced by the applied methods of analysis. Y1 - 2011 U6 - https://doi.org/10.1371/journal.pone.0022826 VL - 6 IS - 8 PB - Plos CY - San Francisco ER - TY - JOUR A1 - Niemüller, Tim A1 - Ferrein, Alexander A1 - Eckel, Gerhard A1 - Pirro, David A1 - Podbregar, Patrick A1 - Kellner, Tobias A1 - Rath, Christoph A1 - Steinbauer, Gerald T1 - Providing Ground-truth Data for the Nao Robot Platform JF - RoboCup 2010: Robot Soccer World Cup XIV Y1 - 2011 SN - 978-3-642-20217-9 N1 - Lecture Notes in Computer Science ; 6556 SP - 133 EP - 144 PB - Springer CY - Berlin ER - TY - JOUR A1 - Bragard, Michael A1 - Conrad, M. A1 - van Hoek, H. A1 - De Doncker, R. W. T1 - The integrated emitter turn-off thyristor (IETO) : an innovative thyristor-based high power semiconductor device using MOS assisted turn-off JF - IEEE transactions on industry applications Y1 - 2011 U6 - https://doi.org/10.1109/TIA.2011.2161432 SN - 0093-9994 VL - 47 IS - 5 SP - 2175 EP - 2182 PB - IEEE CY - New York ER - TY - JOUR A1 - Arida, Hassan A. A1 - Al-Haddad, Ameera A1 - Schöning, Michael Josef T1 - New Solid-State Organic Membrane Based Lead-Selective Micro-Electrode JF - International Journal of Electrochemical Science. 6 (2011), H. 9 Y1 - 2011 SN - 1452-3981 SP - 3858 EP - 3867 ER - TY - CHAP A1 - Schöning, Michael Josef A1 - Abdelghani, Adnane T1 - Nanoscale Science and Technology (NS&T’12) : Proceedings Book Humboldt Kolleg <2012, Tunisia> ; Tunisia, 17-19 March, 2012 / ed. by Michael J. Schöning ; Adnane Abdelghani N2 - Proceedings of the 2nd Humboldt Kolleg, Hammamet, Tunisia Organizer: Alexander von Humboldt Stiftung, Germany. pdf 184 p. Welcome Address Dear Participants, Welcome to the 2nd Humboldt Kolleg in “Nanoscale Science and Technology” (NS&T’12) in Tunisia, sponsored by the "Alexander von Humboldt" foundation. The NS&T’12 multidisciplinary scientific program includes seven "hot" topics dealing with "Nanoscale Science and Technology" covering basic and application-oriented research as well as industrial (market) aspects: - Molecular Biophyics, Spectroscopy Techniques, Imaging Microscopy - Nanomaterials Synthesis for Medicine and Bio-chemical Sensors - Nanostructures, Semiconductors, Photonics and Nanodevices - New Technologies in Market Industry - Environment, Electro-chemistry, Bio-polymers and Fuel Cells - Nanomaterials, Photovoltaic, Modelling, Quantum Physics - Microelectronics, Sensors Networks and Embedded Systems We are deeply indebted to all members of the Scientific Committee and General Chairs for joint Sessions and to all speakers and chairmen, who have dedicated invaluable time and efforts for the realization of this event. On behalf of the Organizing Committee, we are cordially inviting you to join the conference and hope that your stay will be fruitful, rewarding and enjoyable. Prof. Dr. Michael J. Schöning, Prof. Dr. Adnane Abdelghani KW - Biosensor KW - Nanotechnologie KW - Nanomaterial KW - Nano Materials KW - Bio-Sensors Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-3544 ER - TY - JOUR A1 - Werner, Frederik A1 - Wagner, Torsten A1 - Miyamoto, Ko-ichiro A1 - Yoshinobu, Tatsuo A1 - Schöning, Michael Josef T1 - High speed and high resolution chemical imaging based on a new type of OLED-LAPS set-up JF - Sensors and Actuators B: Chemical N2 - Light-addressable potentiometric sensors (LAPS) are field-effect-based sensors. A modulated light source is used to define the particular measurement spot to perform spatially resolved measurements of chemical species and to generate chemical images. In this work, an organic-LED (OLED) display has been chosen as a light source. This allows high measurement resolution and miniaturisation of the system. A new developed driving method for the OLED display optimised for LAPS-based measurements is demonstrated. The new method enables to define modulation frequencies between 1 kHz and 16 kHz and hence, reduces the measurement time of a chemical image by a factor of 40 compared to the traditional addressing of an OLED display. Y1 - 2012 U6 - https://doi.org/10.1016/j.snb.2011.12.102 SN - 0925-4005 N1 - Part of special issue "Selected Papers presented at Eurosensors XXV" VL - 175 SP - 118 EP - 122 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Wagner, Torsten A1 - Werner, Frederik A1 - Miyamoto, Ko-Ichiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Development and characterisation of a compact light-addressable potentiometric sensor (LAPS) based on the digital light processing (DLP) technology for flexible chemical imaging JF - Sensors and Actuators B: Chemical N2 - Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach to read out light-addressable potentiometric sensors (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device, which allows fast and flexible generation of light patterns. With the help of these light patterns, the sensor surface of the LAPS device can be addressed. The DLP approach has several advantages compared to conventional LAPS set-ups, e.g., the spot size and the shape of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of the measurement. In addition, the modulation frequency and intensity of the light beam are important parameters of the LAPS set-up. Within this work, the authors will discuss two different ways of light modulation by the DLP set-up, investigate the influence of different modulation frequencies and different light intensities as well as demonstrate the scanning capabilities of the new set-up by pH mapping on the sensor surface. Y1 - 2012 U6 - https://doi.org/10.1016/j.snb.2010.12.003 SN - 0925-4005 N1 - Part of special issue "Eurosensors XXIV, 2010" VL - 170 SP - 34 EP - 39 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Kaneko, Kazumi A1 - Matsuo, Akira A1 - Wagner, Torsten A1 - Kanoh, Shiníchiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Miniaturized chemical imaging sensor system using an OLED display panel JF - Sensors and Actuators B: Chemical N2 - The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the current–voltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated. KW - LAPS KW - Light-addressable potentiometric sensor KW - Chemical imaging sensor KW - Organic light-emitting diode display Y1 - 2012 U6 - https://doi.org/10.1016/j.snb.2011.02.029 SN - 0925-4005 N1 - Part of special issue "Eurosensors XXIV, 2010" VL - 170 SP - 82 EP - 87 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Rysstad, Gunnar A1 - Schöning, Michael Josef A1 - Keusgen, Michael T1 - Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry JF - Sensors and Actuators B: Chemical N2 - A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 μm) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 °C/(%, v/v) in a H2O2 concentration range of 0%, v/v to 8%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 °C and 270 °C of the gas stream. At flow rates of the gas stream from 8 m3/h to 12 m3/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m3/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes. KW - Sterilisation process KW - Hydrogen peroxide KW - Polyimide KW - Calorimetric gas sensor Y1 - 2012 U6 - https://doi.org/10.1016/j.snb.2011.01.032 SN - 0925-4005 N1 - Part of special issue "Eurosensors XXIV, 2010" VL - 170 SP - 60 EP - 66 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Atlas, Glen A1 - Brealey, David A1 - Dhar, Sunil A1 - Dikta, Gerhard A1 - Singer, Meryvn T1 - Additional hemodynamic measurements with an esophageal Doppler monitor: a preliminary report of compliance, force, kinetic energy, and afterload in the clinical setting JF - Journal of clinical monitoring and computing N2 - The esophageal Doppler monitor (EDM) is a minimally-invasive hemodynamic device which evaluates both cardiac output (CO), and fluid status, by estimating stroke volume (SV) and calculating heart rate (HR). The measurement of these parameters is based upon a continuous and accurate approximation of distal thoracic aortic blood flow. Furthermore, the peak velocity (PV) and mean acceleration (MA), of aortic blood flow at this anatomic location, are also determined by the EDM. The purpose of this preliminary report is to examine additional clinical hemodynamic calculations of: compliance (C), kinetic energy (KE), force (F), and afterload (TSVRi). These data were derived using both velocity-based measurements, provided by the EDM, as well as other contemporaneous physiologic parameters. Data were obtained from anesthetized patients undergoing surgery or who were in a critical care unit. A graphical inspection of these measurements is presented and discussed with respect to each patient’s clinical situation. When normalized to each of their initial values, F and KE both consistently demonstrated more discriminative power than either PV or MA. The EDM offers additional applications for hemodynamic monitoring. Further research regarding the accuracy, utility, and limitations of these parameters is therefore indicated. KW - Acceleration KW - Velocity KW - Kinetic energy KW - Force KW - Compliance KW - Afterload KW - Contractility KW - Volume status KW - Esophageal Doppler monitor Y1 - 2012 SN - 1573-2614 U6 - https://doi.org/10.1007/s10877-012-9386-5 IS - 26 SP - 473 EP - 482 PB - Springer Nature CY - London ER - TY - JOUR A1 - Iken, Heiko A1 - Kirsanov, D. A1 - Legin, A. A1 - Schöning, Michael Josef T1 - Novel Thin-Film Polymeric Materials for the Detection of Heavy Metals JF - Procedia Engineering N2 - A variety of transition metals, e.g., copper, zinc, cadmium, lead, etc. are widely used in industry as components for wires, coatings, alloys, batteries, paints and so on. The inevitable presence of transition metals in industrial processes implies the ambition of developing a proper analytical technique for their adequate monitoring. Most of these elements, especially lead and cadmium, are acutely toxic for biological organisms. Quantitative determination of these metals at low activity levels in different environmental and industrial samples is therefore a vital task. A promising approach to achieve an at-side or on-line monitoring on a miniaturized and cost efficient way is the combination of a common potentiometric sensor array with heavy metal-sensitive thin-film materials, like chalcogenide glasses and polymeric materials, respectively. Y1 - 2012 U6 - https://doi.org/10.1016/j.proeng.2012.09.148 SN - 1877-7058 N1 - Part of special issue "26th European Conference on Solid-State Transducers, EUROSENSOR 2012" IS - 47 SP - 322 EP - 325 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Miyamoto, K. A1 - Ichimura, H. A1 - Wagner, Torsten A1 - Yoshinobu, T. A1 - Schöning, Michael Josef T1 - Chemical Imaging of ion Diffusion in a Microfluidic Channel JF - Procedia Engineering N2 - The chemical imaging sensor is a chemical sensor which is capable of visualizing the spatial distribution of chemical species in sample solution. In this study, a novel measurement system based on the chemical imaging sensor was developed to observe the inside of a Y-shaped microfluidic channel while injecting two sample solutions from two branches. From the collected chemical images, it was clearly observed that the injected solutions formed laminar flows in the microfluidic channel. In addition, ion diffusion across the laminar flows was observed. This label-free method can acquire quantitative data of ion distribution and diffusion in microfluidic devices, which can be used to determine the diffusion coefficients, and therefore, the molecular weights of chemical species in the sample solution. Y1 - 2012 U6 - https://doi.org/10.1016/j.proeng.2012.09.289 SN - 1877-7058 N1 - Part of special issue "26th European Conference on Solid-State Transducers, EUROSENSOR 2012" IS - 47 SP - 886 EP - 889 PB - Elsevier CY - Amsterdam ER -