TY - JOUR A1 - Werner, Frederik A1 - Takenaga, Shoko A1 - Taki, Hidenori A1 - Sawada, Kazuaki A1 - Schöning, Michael Josef T1 - Comparison of label-free ACh-imaging sensors based on CCD and LAPS JF - Sensors and Actuators B: Chemical (2012) N2 - Semiconductor-based chemical imaging sensors, like the light-addressable potentiometric sensor (LAPS) or the pH-imaging sensor based on a charge-coupled device (CCD), are becoming a powerful tool for label-free imaging of biological phenomena. We have proposed a polyion-based enzymatic membrane to develop an acetylcholine (ACh) imaging sensor for neural cell-activity observations. In this study, a CCD-type ACh-imaging sensor and a LAPS-type ACh-imaging sensor were fabricated and the prospect of both sensors was clarified by making a comparison of their basic characteristics. Y1 - 2013 SN - 0925-4005 VL - 177 SP - 745 EP - 752 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kaminsky, Randolph A1 - Weber, Hans-Joachim A1 - Simons, Antoine A1 - Kallweit, Stephan A1 - Kramm, K. A1 - Verdonck, Pascale T1 - Comparison of the flow downstream two prototypes of a new monoleaflet artificial aortic heart valve by means of PIV visualization JF - Computer methods in biomechanics and biomedical engineering. 8 (2005), H. 4, Suppl. 1 Y1 - 2005 SN - 1476-8259 SP - 159 EP - 160 ER - TY - JOUR A1 - Nguyen-Xuan, H. A1 - Rabczuk, T. A1 - Nguyen-Thoi, T. A1 - Tran, Thanh Ngoc A1 - Nguyen-Thanh, N. T1 - Computation of limit and shakedown loads using a node-based smoothed finite element method JF - International Journal for Numerical Methods in Engineering N2 - This paper presents a novel numerical procedure for computing limit and shakedown loads of structures using a node-based smoothed FEM in combination with a primal–dual algorithm. An associated primal–dual form based on the von Mises yield criterion is adopted. The primal-dual algorithm together with a Newton-like iteration are then used to solve this associated primal–dual form to determine simultaneously both approximate upper and quasi-lower bounds of the plastic collapse limit and the shakedown limit. The present formulation uses only linear approximations and its implementation into finite element programs is quite simple. Several numerical examples are given to show the reliability, accuracy, and generality of the present formulation compared with other available methods. Y1 - 2011 U6 - http://dx.doi.org/10.1002/nme.3317 SN - 1097-0207 VL - 90 IS - 3 SP - 287 EP - 310 PB - Wiley CY - Weinheim ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - Computational Analysis of Pelvic Floor Dysfunction T2 - Women's Health and Biomechanics N2 - Pelvic floor dysfunction (PFD) is characterized by the failure of the levator ani (LA) muscle to maintain the pelvic hiatus, resulting in the descent of the pelvic organs below the pubococcygeal line. This chapter adopts the modified Humphrey material model to consider the effect of the muscle fiber on passive stretching of the LA muscle. The deformation of the LA muscle subjected to intra-abdominal pressure during Valsalva maneuver is compared with the magnetic resonance imaging (MRI) examination of a nulliparous female. Numerical result shows that the fiber-based Humphrey model simulates the muscle behavior better than isotropic constitutive models. Greater posterior movement of the LA muscle widens the levator hiatus due to lack of support from the anococcygeal ligament and the perineal structure as a consequence of birth-related injury and aging. Old and multiparous females with uncontrolled urogenital and rectal hiatus tend to develop PFDs such as prolapse and incontinence. KW - Pelvic muscle KW - Muscle fibers KW - Passive stretching KW - Pelvic floor dysfunction Y1 - 2018 SN - 978-3-319-71574-2 U6 - http://dx.doi.org/10.1007/978-3-319-71574-2_17 N1 - Lecture Notes in Computational Vision and Biomechanics, vol 29 SP - 217 EP - 230 PB - Springer CY - Cham ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Waluga, C. A1 - Arlt, S. A1 - Behr, M. A1 - Mottaghy, K. T1 - Computational Analysis of Platelet Aggregation in a Taylor-Couette System JF - The International Journal of Artificial Organs. 31 (2008), H. 7 Y1 - 2008 SN - 0391-3988 N1 - Posterpresentation ; European Society of Artificial Organs (ESAO), Geneva, Switzerland SP - 643 ER - TY - JOUR A1 - Bhattarai, Aroj A1 - Staat, Manfred T1 - Computational comparison of different textile implants to correct apical prolapse in females JF - Current Directions in Biomedical Engineering N2 - Prosthetic textile implants of different shapes, sizes and polymers are used to correct the apical prolapse after hysterectomy (removal of the uterus). The selection of the implant before or during minimally invasive surgery depends on the patient’s anatomical defect, intended function after reconstruction and most importantly the surgeon’s preference. Weakness or damage of the supporting tissues during childbirth, menopause or previous pelvic surgeries may put females in higher risk of prolapse. Numerical simulations of reconstructed pelvic floor with weakened tissues and organ supported by textile product models: DynaMesh®-PRS soft, DynaMesh®-PRP soft and DynaMesh®-CESA from FEG Textiletechnik mbH, Germany are compared. Y1 - 2018 U6 - http://dx.doi.org/10.1515/cdbme-2018-0159 VL - 4 IS - 1 SP - 661 EP - 664 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Malinowski, Daniel A1 - Fournier, Yvan A1 - Horbach, Andreas A1 - Frick, Michael A1 - Magliani, Mirko A1 - Kalverkamp, Sebastian A1 - Hildinger, Martin A1 - Spillner, Jan A1 - Behbahani, Mehdi A1 - Hima, Flutura T1 - Computational fluid dynamics analysis of endoluminal aortic perfusion JF - Perfusion N2 - Introduction: In peripheral percutaneous (VA) extracorporeal membrane oxygenation (ECMO) procedures the femoral arteries perfusion route has inherent disadvantages regarding poor upper body perfusion due to watershed. With the advent of new long flexible cannulas an advancement of the tip up to the ascending aorta has become feasible. To investigate the impact of such long endoluminal cannulas on upper body perfusion, a Computational Fluid Dynamics (CFD) study was performed considering different support levels and three cannula positions. Methods: An idealized literature-based- and a real patient proximal aortic geometry including an endoluminal cannula were constructed. The blood flow was considered continuous. Oxygen saturation was set to 80% for the blood coming from the heart and to 100% for the blood leaving the cannula. 50% and 90% venoarterial support levels from the total blood flow rate of 6 l/min were investigated for three different positions of the cannula in the aortic arch. Results: For both geometries, the placement of the cannula in the ascending aorta led to a superior oxygenation of all aortic blood vessels except for the left coronary artery. Cannula placements at the aortic arch and descending aorta could support supra-aortic arteries, but not the coronary arteries. All positions were able to support all branches with saturated blood at 90% flow volume. Conclusions: In accordance with clinical observations CFD analysis reveals, that retrograde advancement of a long endoluminal cannula can considerably improve the oxygenation of the upper body and lead to oxygen saturation distributions similar to those of a central cannulation. KW - computational fluid dynamics analysis KW - simulation KW - endoluminal KW - aortic perfusion KW - extracorporeal membrane oxygenation Y1 - 2022 U6 - http://dx.doi.org/10.1177/02676591221099809 SN - 1477-111X VL - 0 IS - 0 SP - 1 EP - 8 PB - Sage CY - London ER - TY - JOUR A1 - Frotscher, Ralf A1 - Koch, Jan-Peter A1 - Staat, Manfred T1 - Computational investigation of drug action on human-induced stem cell derived cardiomyocytes JF - Journal of biomechanical engineering Y1 - 2015 U6 - http://dx.doi.org/10.1115/1.4030173 SN - 1528-8951 (E-Journal); 0148-0731 (Print) VL - Vol. 137 IS - iss. 7 SP - 071002-1 EP - 071002-7 PB - ASME CY - New York ER - TY - BOOK A1 - Grotendorst, Johannes T1 - Computational Nanoscience: Do it yourself! : winter school, 14 - 22 February 2006, Forschungszentrum Jülich, Germany ; lecture notes / Grotendorst, Johannes Y1 - 2006 SN - 3-00-017350-1 N1 - NIC series ; 31 ; Forschungszentrum / John-von-Neumann-Institut für Computing PB - NIC CY - Jülich ER - TY - CHAP A1 - Voronkova, Eva B. A1 - Bauer, Svetlana M. A1 - Kotliar, Konstantin T1 - Computer simulation of the cornea-scleral shell as applied to pressure-volume relationship in the human eye T2 - 2014 International Conference on Computer Technologies in Physical and Engineering Applications : ICCTPEA 2014 : proceedings : June 30 2014-July 4 2014, St. Petersburg Y1 - 2014 SN - 978-1-4799-5315-8 SP - 204 EP - 205 ER - TY - JOUR A1 - Grotendorst, Johannes A1 - Dornseiffer, Jürgen T1 - Computer-aided Modelling and Simulation of the Thermodynamics of Steam Reforming / Grotendorst, Johannes ; Dornseiffer, Jürgen JF - Mathematics and Computers in Simulation. 51 (2000), H. 5 Y1 - 2000 SN - 0378-4754 N1 - Technical Report FZJ-ZAM-IB-9812, August 1998 SP - 451 EP - 471 ER - TY - CHAP A1 - Jung, Alexander A1 - Staat, Manfred ED - Erni, Daniel T1 - Computing olympic gold: Ski jumping as an example T2 - 1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen Y1 - 2016 SN - 978-3-940402-06-6 U6 - http://dx.doi.org/10.17185/duepublico/40821 SP - 54 EP - 55 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Molinnus, Denise A1 - Bäcker, Matthias A1 - Iken, Heiko A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Concept for a biomolecular logic chip with an integrated sensor and actuator function JF - Physica status solidi (a) N2 - A concept for a new generation of an integrated multi-functional biosensor/actuator system is developed, which is based on biomolecular logic principles. Such a system is expected to be able to detect multiple biochemical input signals simultaneously and in real-time and convert them into electrical output signals with logical operations such as OR, AND, etc. The system can be designed as a closed-loop drug release device triggered by an enzyme logic gate, while the release of the drug induced by the actuator at the required dosage and timing will be controlled by an additional drug sensor. Thus, the system could help to make an accurate and specific diagnosis. The presented concept is exemplarily demonstrated by using an enzyme logic gate based on a glucose/glucose oxidase system, a temperature-responsive hydrogel mimicking the actuator function and an insulin (drug) sensor. In this work, the results of functional testing of individual amperometric glucose and insulin sensors as well as an impedimetric sensor for the detection of the hydrogel swelling/shrinking are presented. Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431913 SN - 1862-6319 VL - 212 IS - 6 SP - 1382 EP - 1388 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Bäcker, Matthias A1 - Beging, Stefan A1 - Biselli, Manfred A1 - Poghossian, Arshak A1 - Wang, J. A1 - Zang, Werner A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Concept for a solid-state multi-parameter sensor system for cell-culture monitoring JF - Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI Y1 - 2009 SN - 0013-4686 SP - 6107 EP - 6112 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Stulpe, Werner T1 - Conditional Expectations and Stochastic Processes in Quantum Probability JF - Information complexity and control in quantum physics : proceedings of the 4. Internat. Seminar on Mathematical Theory of Dynamical Systems and Microphysics, Udine, Sept. 4 - 13, 1985 / ed. by A. Blaquiere ... Y1 - 1987 SN - 3-211-81992-4 N1 - Courses and lectures / International Centre for Mechanical Sciences ; 294, International Seminar on Mathematical Theory of Dynamical Systems and Microphysics <4,1985, Udine> SP - 223 EP - 234 PB - Springer CY - Wien [u.a.] ER - TY - JOUR A1 - Stulpe, Werner T1 - Conditional Expectations, Conditional Distributions, and A Posteriori Ensembles in Generalized Probability Theory JF - International Journal of Theoretical Physics. 27 (1988), H. 5 Y1 - 1988 SN - 1572-9575 SP - 587 EP - 611 ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Beuscher, H. A1 - Haenni, D. R. T1 - Configuration of bands and intrinsic levels in ¹³⁴ Ce JF - Annual report 1982 / Kernforschungsanlage Jülich Institut für Kernphysik / Hrsg.: F. Grümmer. - (Spezielle Berichte der Kernforschungsanlage Jülich ; 202) Y1 - 1983 SP - 43 PB - Kernforschungsanlage Jülich CY - Jülich ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schroth, P. A1 - Schütz, S. A1 - Hummel, Hans E. A1 - Lüth, H. T1 - Connecting an insect antenna to a microchip as a novel type of biosensor JF - Proceedings : applications, trends, visions / VDE World Microtechnologies Congress, September 25 - 27, 2000, Expo 2000, Hannover, Germany. Organized by VDE Association for Electrical, Electronic & Information Technologies ....Vol 2. Y1 - 2000 SN - 3-8007-2579-7 N1 - MICRO.tec <1, 2000, Hannover>; auch als CD-ROM SP - 411 EP - 416 PB - VDE-Verl. CY - [Berlin] [u.a.] ER - TY - JOUR A1 - Yoshinobu, T. A1 - Ecken, H. A1 - Poghossian, Arshak A1 - Simonis, A. A1 - Iwasaki, H. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Constant-current-mode LAPS (CLAPS) for the detection of penicillin JF - Electroanalysis. 13 (2001), H. 8-9 Y1 - 2001 SN - 1040-0397 SP - 733 EP - 736 ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Mimura, Shuhei A1 - Kanoh, Shin`ichiro A1 - Yoshinobu, Tatsuo A1 - Schöning, Michael Josef T1 - Constant-phase-mode operation of the light-addressable potentiometric sensor JF - Procedia Chemistry. 1 (2009), H. 1 Y1 - 2009 SN - 1876-6196 N1 - Proceedings of the Eurosensors XXIII conference ; Eurosensors 23 SP - 1487 EP - 1490 PB - Elsevier CY - Amsterdam ER -