TY - JOUR A1 - Kirchner, Patrick A1 - Spelthahn, H. A1 - Schöning, Michael Josef A1 - Henkel, H. A1 - Schneider, A. A1 - Friedrich, P. A1 - Kolstad, J. A1 - Berger, J. T1 - Realisierung eines Polyimid-basierten kalorimetrischen Gassensors zur Inline-Überwachung der H2O2-Konzentration in aseptischen Abfüllanlagen JF - Sensoren und Messsysteme 2010 [Elektronische Ressource] : Vorträge der 15. ITG/GMA-Fachtagung vom 18. bis 19. Mai 2010 in Nürnberg / Informationstechnische Gesellschaft im VDE (ITG); VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA) Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Fachtagung Sensoren und Messsysteme 15, 2010, Nürnberg ; Gesellschaft Mess- und Automatisierungstechnik SP - 607 EP - 612 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Friedrich, Peter A1 - Rysstad, G. A1 - Berger, J. A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Realization of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference SP - 264 EP - 267 ER - TY - JOUR A1 - Jansen, Sebastian A1 - Behbahani, Mehdi A1 - Laumen, Marco A1 - Kaufmann, Tim A1 - Hormes, Marcus A1 - Schmitz-Rode, Thomas A1 - Behr, Marek A1 - Steinseifer, Ulrich T1 - 3D Stereo-PIV Validation for CFD-Simulation of Steady Flow through the Human Aorta using Rapid-Prototyping techniques Y1 - 2010 N1 - abstract ; IV International Symposium on Modelling of Physiological Flows, Sardinia, Italy, June 02-05, 2010 ; MPF2010 ER - TY - JOUR A1 - Jansen, S. V. A1 - Behbahani, Mehdi A1 - Laumen, M. A1 - Kaufmann, T. A1 - Hormes, M. A1 - Behr, M. A1 - Schmitz-Rode, T. A1 - Steinseifer, U. T1 - Investigation of Steady Flow Through a Realistic Model of the Thoracic Human Aorta Using 3D Stereo PIV and CFD-Simulation Y1 - 2010 N1 - Posterpresentation ; American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 ER - TY - JOUR A1 - Horstmann, Marie-Therese A1 - Bialonski, Stephan A1 - Noenning, Nina A1 - Mai, Heinke A1 - Prusseit, Jens A1 - Wellmer, Jörg A1 - Hinrichs, Hermann A1 - Lehnertz, Klaus T1 - State dependent properties of epileptic brain networks: Comparative graph–theoretical analyses of simultaneously recorded EEG and MEG JF - Clinical Neurophysiology N2 - Objective To investigate whether functional brain networks of epilepsy patients treated with antiepileptic medication differ from networks of healthy controls even during the seizure-free interval. Methods We applied different rules to construct binary and weighted networks from EEG and MEG data recorded under a resting-state eyes-open and eyes-closed condition from 21 epilepsy patients and 23 healthy controls. The average shortest path length and the clustering coefficient served as global statistical network characteristics. Results Independent on the behavioral condition, epileptic brains exhibited a more regular functional network structure. Similarly, the eyes-closed condition was characterized by a more regular functional network structure in both groups. The amount of network reorganization due to behavioral state changes was similar in both groups. Consistent findings could be achieved for networks derived from EEG but hardly from MEG recordings, and network construction rules had a rather strong impact on our findings. Conclusions Despite the locality of the investigated processes epileptic brain networks differ in their global characteristics from non-epileptic brain networks. Further methodological developments are necessary to improve the characterization of disturbed and normal functional networks. Significance An increased regularity and a diminished modulation capability appear characteristic of epileptic brain networks. Y1 - 2010 U6 - https://doi.org/10.1016/j.clinph.2009.10.013 SN - 1388-2457 VL - 121 IS - 2 SP - 172 EP - 185 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hirschfeld, J. A. A1 - Lustfeld, H. A1 - Reißel, Martin A1 - Steffen, B. T1 - A novel scheme for precise diagnostics and effective stabilization of currents in a fuel cell stack JF - International Journal of Energy Research. 34 (2010), H. 3 Y1 - 2010 SN - 0363-907X SP - 293 EP - 301 ER - TY - JOUR A1 - Hirschfeld, J. A. A1 - Lustfeld, H. A1 - Reißel, Martin A1 - Steffen, B. T1 - Tomographic diagnostics of current distributions in a fuel cell stack JF - International Journal of Energy Research Y1 - 2010 SN - 0363-907X VL - 34 IS - 3 SP - 284 EP - 292 ER - TY - JOUR A1 - Herzog, Hans A1 - Pietrzyk, Uwe A1 - Shah, N. Jon A1 - Ziemons, Karl T1 - The current state, challenges and perspectives of MR-PET JF - Neuroimage N2 - Following the success of PET/CT during the last decade and the recent increasing proliferation of SPECT/CT, another hybrid imaging instrument has been gaining more and more interest: MR-PET. First combined, simultaneous PET and MR studies carried out in small animals demonstrated the feasibility of the new approach. Concurrently, some prototypes of an MR-PET scanner for simultaneous human brain studies have been built, their performance is being tested and preliminary applications have already been shown. Through this pioneering work, it has become clear that advances in the detector design are necessary for further optimization. Recently, the different issues related to the present state and future prospects of MR-PET were presented and discussed during an international 2-day workshop at the Forschungszentrum Jülich, Germany, held after, and in conjunction with, the 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference in Dresden, Germany on October 27–28, 2008. The topics ranged from small animal MR-PET imaging to human MR-BrainPET imaging, new detector developments, challenges/opportunities for ultra-high field MR-PET imaging and considerations of possible future research and clinical applications. This report presents a critical summary of the contributions made to the workshop. Y1 - 2010 U6 - https://doi.org/10.1016/j.neuroimage.2009.10.036 SN - 1053-8119 VL - 49 IS - 3 SP - 2072 EP - 2082 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Heinzel, Alexander A1 - Schäfer, Ralf A1 - Müller, Hans-Wilhelm A1 - Schieffer, Andre A1 - Ingenhag, Ariane A1 - Northoff, Georg A1 - Franz, Matthias A1 - Hautzel, Hubertus T1 - Differential modulation of valence and arousal in high-alexithymic and low-alexithymic individuals JF - Neuroreport N2 - High-alexithymic individuals are characterized by an impaired ability to identify and communicate emotions whereas low-alexithymic individuals have a wide-ranging ability to deal with emotions. This study examined the hypothesis that valence and arousal modifications of emotional stimuli differentially modulate cortical regions in high-alexithymic and low-alexithymic individuals. To this end, 28 high-alexithymic and 25 low-alexithymic individuals were investigated with event-related fMRI using visual emotional stimuli. We found differential neural activations in the dorsal anterior cingulate, the insula and the amygdala. We suggest that these differences may account for the impaired ability of high-alexithymic individuals to appropriately handle emotional stimuli. Y1 - 2010 U6 - https://doi.org/10.1097/WNR.0b013e32833f38e0 SN - 1473-558X VL - 21 IS - 15 SP - 998 EP - 1002 PB - Lippincott Williams & Wilkins CY - London ER - TY - JOUR A1 - Heinzel, Alexander A1 - Schäfer, Ralf A1 - Müller, Hans-Wilhelm A1 - Schieffer, Andre A1 - Ingenhag, Ariane A1 - Eickhoff, Simon B. A1 - Northoff, Georg A1 - Franz, Matthias A1 - Hautzel, Hubertus T1 - Increased Activation of the Supragenual Anterior Cingulate Cortex during Visual Emotional Processing in Male Subjects with High Degrees of Alexithymia: An Event-Related fMRI Study JF - Psychotherapy and Psychosomatics N2 - Background: One of the most prominent neurobiological models of alexithymia assumes an altered function of the anterior cingulate cortex (ACC) as the crucial neural correlate of alexithymia. So far functional imaging studies have yielded inconclusive results. Therefore, we tested this hypothesis in healthy alexithymics and nonalexithymics in an event-related fMRI study. Methods: Thirty high- and 30 low-alexithymic right-handed male subjects (selected by the 20-item Toronto Alexithymia Scale, TAS-20) were investigated with event-related fMRI using a picture viewing paradigm. The stimuli consisted of happy, fearful and neutral facial expressions (Ekman-Friesen) as well as positive, negative and neutral pictures from the International Affective Picture System. Results: Contrasting the high-alexithymic with the low-alexithymic group we observed increased activation of the supragenual ACC for different emotional valences as well as for different emotional stimuli. Moreover, there was a positive correlation of the ACC with the individual TAS-20 scores but no correlations with the individual Beck Depression Inventory scores. Additionally, there was no difference in activity of the amygdala. Conclusions: We demonstrated that the supragenual ACC is constantly activated more strongly in alexithymic subjects and that this activation is related to the symptoms of alexithymia and not to associated symptoms such as depression. Therefore, our findings support the hypothesis of an altered function of the ACC in alexithymia. Y1 - 2010 U6 - https://doi.org/10.1159/000320121 SN - 0033-3190 VL - 79 IS - 6 SP - 363 EP - 370 PB - Karger CY - Basel ER - TY - JOUR A1 - Grottke, O. A1 - Braunschweig, T. A1 - Philippen, B. A1 - Gatzweiler, Karl-Heinz A1 - Gronloh, N. A1 - Staat, Manfred A1 - Rossaint, R. A1 - Tolba, R. T1 - A New Model for Blunt Liver Injuries in the Swine JF - European Surgical Research. 44 (2010), H. 2 Y1 - 2010 SN - 1421-9921 SP - 65 EP - 73 ER - TY - JOUR A1 - Grajewski, Matthias A1 - Köster, Michael A1 - Turek, Stefam T1 - Numerical analysis and implementational aspects of a new multilevel grid deformation method JF - Applied Numerical Mathematics N2 - Recently, we introduced and mathematically analysed a new method for grid deformation (Grajewski et al., 2009) [15] we call basic deformation method (BDM) here. It generalises the method proposed by Liao et al. (Bochev et al., 1996; Cai et al., 2004; Liao and Anderson, 1992) [4], [6], [20]. In this article, we employ the BDM as core of a new multilevel deformation method (MDM) which leads to vast improvements regarding robustness, accuracy and speed. We achieve this by splitting up the deformation process in a sequence of easier subproblems and by exploiting grid hierarchy. Being of optimal asymptotic complexity, we experience speed-ups up to a factor of 15 in our test cases compared to the BDM. This gives our MDM the potential for tackling large grids and time-dependent problems, where possibly the grid must be dynamically deformed once per time step according to the user's needs. Moreover, we elaborate on implementational aspects, in particular efficient grid searching, which is a key ingredient of the BDM. Y1 - 2010 U6 - https://doi.org/10.1016/j.apnum.2010.03.017 SN - 0168-9274 VL - 60 IS - 8 SP - 767 EP - 781 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Gerhards, M. A1 - Belloum, A. A1 - Berretz, F. A1 - Sander, Volker A1 - Skorupa, S. T1 - A history-tracing XML-based provenance framework for workflows Y1 - 2010 SN - 978-1-4244-8989-3 N1 - Workflows in Support of Large-Scale Science (WORKS), 2010 5th Workshop on SP - 1 EP - 10 ER - TY - JOUR A1 - Garhofer, Gerhard A1 - Bek, Toke A1 - Boehm, Andreas G. A1 - Gherghel, Doina A1 - Grundwald, Juan A1 - Jeppesen, Peter A1 - Kergoat, Hélène A1 - Kotliar, Konstantin A1 - Lanzl, Ines A1 - Lovasik, John V. A1 - Nagel, Edgar A1 - Vilser, Walthard A1 - Orgul, Selim A1 - Schmetterer, Leopold T1 - Use of the retinal vessel analyzer in ocular blood flow research JF - Acta Ophthalmol N2 - The present article describes a standard instrument for the continuous online determination of retinal vessel diameters, the commercially available retinal vessel analyzer. This report is intended to provide informed guidelines for measuring ocular blood flow with this system. The report describes the principles underlying the method and the instruments currently available, and discusses clinical protocol and the specific parameters measured by the system. Unresolved questions and the possible limitations of the technique are also discussed. Y1 - 2010 U6 - https://doi.org/10.1111/j.1755-3768.2009.01587.x SN - 1755-3768 VL - 88 IS - 7 SP - 717 EP - 722 PB - Wiley-Blackwell CY - Oxford ER - TY - CHAP A1 - Digel, Ilya A1 - Leimena, W. A1 - Dachwald, Bernd A1 - Linder, Peter A1 - Porst, Dariusz A1 - Kayser, Peter A1 - Funke, O. A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard T1 - In-situ biological decontamination of an ice melting probe : [abstract] N2 - The objective of our study was to investigate the efficacy of different in-situ decontamination protocols in the conditions of thermo-mechanical ice-melting. KW - Sonde KW - Dekontamination KW - Wasserstoffperoxid KW - Natriumhypochlorit Y1 - 2010 ER - TY - JOUR A1 - Digel, Ilya T1 - In-situ biological decontamination of an ice melting probe Y1 - 2010 N1 - 38th COSPAR Scientific Assembly. Held 18-15 July 2010, in Bremen, Germany Abstract unter https://www.cospar-assembly.org/abstractcd/OLD/COSPAR-10/abstracts/data/pdf/abstracts/F36-0013-10.pdf ER - TY - JOUR A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Schnitzler, Thomas A1 - Biselli, Manfred A1 - Zang, Werner A1 - Wagner, P. T1 - Entwicklung eines modularen festkörperbasierten Sensorsystems für die Überwachung von Zellkulturfermentationen JF - Sensoren und Messsysteme 2010 [Elektronische Ressource] : Vorträge der 15. ITG/GMA-Fachtagung vom 18. bis 19. Mai 2010 in Nürnberg / Informationstechnische Gesellschaft im VDE (ITG); VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA) Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Fachtagung Sensoren und Messsysteme 15, 2010, Nürnberg ; Gesellschaft Mess- und Automatisierungstechnik SP - 688 EP - 698 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Wenmackers, Sylvia A1 - Janssens, Stoffel D. A1 - Haenen, Ken A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Capacitive field-effect (bio-)chemical sensors based on nanocrystalline diamond films JF - Diamond Electronics and Bioelectronics — Fundamentals to Applications III, edited by P. Bergonzo, [u.a.] Y1 - 2010 N1 - MRS Proceedings Volume 1203 paper 1203-J17-31 ; Mater. Res. Soc. Sympos. Proc. Vol 1203 (2010) ; Materials Research Society SP - 1 EP - 6 ER - TY - JOUR A1 - Buniatyan, Vahe V. A1 - Abouzar, Maryam H. A1 - Martirosyan, Norayr W. A1 - Schubert, Jürgen A1 - Gevorgian, Spartak A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - pH-sensitive properties of barium strontium titanate (BST) thin films prepared by pulsed laser deposition technique JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 824 EP - 830 ER - TY - JOUR A1 - Bohrn, U. A1 - Stütz, E. A1 - Fleischer, M. A1 - Schöning, Michael Josef T1 - Real-time detection of CO by eukaryotic cells JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference SP - 17 EP - 20 ER -