TY - CHAP A1 - Hadinejad-Mahram, Hafez A1 - Gligorevic, Snjezana A1 - Ritscher, Matthias T1 - Joint iterative channel estimation and parallel interference cancellation for coded DS-CDMA T2 - Proceeding of the International Conference on Telecommunications 2002 : [Beijing, 23 - 26 June 2002]. Vol. 2 Y1 - 2002 SP - 566 EP - 570 ER - TY - CHAP A1 - Gligorevic, Snjezana T1 - Joint channel estimation and equalization for fast time-variant multipath channels T2 - Proceedings / 13th IEEE International Symposium on Personal, Indoor and Mobile Radio Communications : PIMRC 2002 : Lisboa, Portugal, September 15 - 18, 2002 Y1 - 2002 SN - 0-7803-7589-0 SP - 1127 EP - 1130 ER - TY - CHAP A1 - Gligorevic, Snjezana A1 - Sorger, Ulrich T1 - A new approach to tracking time-variant channels T2 - Proceedings / 5th International Symposium on Wireless Personal Multimedia Communications : WPMC : October 27 - 30, 2002, Honolulu, Hawaii ; vol. 3 Y1 - 2002 SN - 0-7803-7442-8 SN - 1347-6890 SP - 1342 EP - 1345 ER - TY - JOUR A1 - Alt, Helmut T1 - Belieferung von Kunden in fremden Netzgebieten JF - EW : das Magazin für die Energie-Wirtschaft Y1 - 2002 SN - 0013-5496 N1 - Printausg. in der Bibliothek vorhanden: 23 Z 585 VL - Bd. 101 IS - H. 1/2 SP - 26 EP - 35 ER - TY - GEN A1 - Krämer, David T1 - Development of a gene filter array protocol for studies of gene regulation by AMP activated protein kinase (AMPK) Y1 - 2002 ER - TY - JOUR A1 - Gerigk, M. A1 - Maaß, D. A1 - Kreutzer, A. A1 - Sprenger, G. A1 - Bongaerts, Johannes A1 - Wubbolts, Marcel A1 - Takors, Ralf T1 - Enhanced pilot-scale fed-batch L-phenylalanine production with recombinant Escherichia coli by fully integrated reactive extraction JF - Bioprocess and biosystems engineering Y1 - 2002 SN - 1432-0797 (E-Journal); 1615-7605 (E-Journal); 0178-515X (Print); 1615-7591 (Print) VL - Vol. 25 IS - Iss. 1 SP - 43 EP - 52 ER - TY - JOUR A1 - Gerigk, M. A1 - Bujnicki, R. A1 - Ganpo-Nkwenkwa, E. A1 - Bongaerts, Johannes A1 - Sprenger, G. A1 - Takors, Ralf T1 - Process control for enhanced L-phenylalanine production using different recombinant Escherichia coli strains JF - Biotechnology and bioengineering Y1 - 2002 SN - 1097-0290 (E-Journal); 0006-3592 (Print) VL - Vol. 80 IS - Iss. 7 SP - 746 EP - 754 ER - TY - JOUR A1 - Bongaerts, Johannes A1 - Bovenberg, Roel A1 - Krämer, Marco A1 - Müller, Ulrike A1 - Raeven, Leon A1 - Wubbolts, Marcel T1 - Metabolic engineering to produce fine chemicals in Escherichia coli JF - Chemie - Ingenieur - Technik (CIT) Y1 - 2002 SN - 1522-2640 (E-Journal); 0009-286X (Print) N1 - Printausg. in der Bibliothek vorhanden: 63 ZS 022 VL - Vol. 74 IS - Iss. 5 SP - 694 ER - TY - JOUR A1 - Schmitz, M. A1 - Hirsch, E. A1 - Bongaerts, Johannes A1 - Takors, Ralf T1 - Pulse experiments as a prerequisite for the quantification of in vivo enzyme kinetics in aromatic amino acid pathway of Eschericia coli JF - Biotechnology progress Y1 - 2002 SN - 1520-6033 (E-Journal); 8756-7938 (Print) VL - Vol. 18 IS - Iss. 5 SP - 935 EP - 941 ER - TY - BOOK A1 - Goldbach, Daniel T1 - Steuerung und Regelung der aktiven Anhängerkupplung eines Farhzeuggespanns Y1 - 2002 N1 - Fulda, Fachhochsch., Dipl.-Arbeit, 2002 ER - TY - CHAP A1 - Göttsche, Joachim T1 - Erste Energiebilanz der Studentenwohnungen des Solar-Campus Jülich T2 - Zwölftes Symposium Thermische Solarenergie : 24. bis 26. April 2002, Kloster Banz, Bad Staffelstein Y1 - 2002 SN - 3-934681-20-4 SP - 251 EP - 256 PB - OTTI-Energie-Kolleg CY - Regensburg ER - TY - CHAP A1 - Vieira da Silva, Maria Eugenia A1 - Schwarzer, Klemens A1 - Queiroz Medeiros, Marcelo Ricardo T1 - Experimental results of a solar cooker with heat storage T2 - RIO 02 - World Climate & Energy Event, January 6-11, 2002 Y1 - 2002 ER - TY - CHAP A1 - Buxbaum, Bernd A1 - Schwarte, Rudolf A1 - Ringbeck, Thorsten A1 - Grothof, Markus A1 - Luan, Xuming ED - Schreiber, Ulrich T1 - MSM-PMD as correlation receiver in a new 3D-ranging system T2 - Laser radar ranging and atmospheric lidar techniques III : 17 - 18 September 2001, Toulouse, France. - (SPIE proceedings series ; 4546) Y1 - 2002 SN - 0-8194-4271-2 U6 - https://doi.org/10.1117/12.453994 SN - 0038-7355 SN - 0361-0748 SN - 0277-786X N1 - Laser Radar: Ranging and Atmospheric Lidar Techniques <3, 2001, Toulouse> SP - 145 EP - 154 PB - SPIE CY - Bellingham, Wash. ER - TY - BOOK A1 - Ringbeck, Thorsten T1 - Untersuchung opto-elektrischer Phasenregelkreise auf Basis von Photomischdetektoren hinsichtlich deren Anwendungspotential für die Photonik Y1 - 2002 SN - 3-8265-9789-3 N1 - Zugl.: Siegen, Univ., Diss., 2001.- (ZESS-Forschungsberichte ; Nr. 16) PB - Shaker-Verl. CY - Aachen ER - TY - CHAP A1 - Zang, Zhigang A1 - Hess, Holger A1 - Ringbeck, Thorsten A1 - Schwarte, Rudolf ED - Kamerman, Gary W. T1 - Phase-lock techniques using new correlation receivers for TOF-laser ranging T2 - Laser radar technology and applications VII : 3 - 4 April 2002, Orlando, USA. - (SPIE proceedings series ; 4723) Y1 - 2002 SN - 0-8194-4473-1 U6 - https://doi.org/10.1117/12.476402 SN - 0038-7355 SN - 0361-0748 SN - 0277-786X N1 - Laser Radar Technology and Applications <7, 2002, Orlando, FL> SP - 112 EP - 120 PB - SPIE, International Society for Optical Engineering CY - Bellingham, Wash. ER - TY - CHAP A1 - Grothof, M. A1 - Schwarte, Rudolf A1 - Buxbaum, Bernd A1 - Ringbeck, Thorsten ED - Wagner, Elmar T1 - Product monitoring with MSM-PMD-Array T2 - Proceedings / OPTO 2002 : an event of the Association for Sensor Technology AMA ; 14 - 16 May 2002, Exhibition Centre Erfurt, Germany / International Conference Optoelectronics, Optical Sensors & Measuring Techniques Y1 - 2002 N1 - OPTO <5, 2002, Erfurt> ; International Conference Optoelectronics, Optical Sensors & Measuring Techniques SP - 41 EP - 47 PB - AMA Service GmbH CY - Wunsdorf ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - A PET system based on data processing of free-running sampled pulses JF - 2001 IEEE Nuclear Science Symposium Conference Record, Vol. 2 N2 - Within the developments for the Crystal Clear small animal PET project (CLEARPET) a dual head PET system has been established. The basic principle is the early digitization of the detector pulses by free running ADCs. The determination of the γ-energy and also the coincidence detection is performed by data processing of the sampled pulses on the host computer. Therefore a time mark is attached to each pulse identifying the current cycle of the 40 MHz sampling clock. In order to refine the time resolution the pulse starting time is interpolated from the samples of the pulse rise. The detector heads consist of multichannel PMTs with a single LSO scintillator crystal coupled to each channel. For each PMT only one ADC is required. The position of an event is obtained separately from trigger signals generated for each single channel. An FPGA is utilized for pulse buffering, generation of the time mark and for the data transfer to the host via a fast I/O-interface. Y1 - 2002 SN - 1082-3654 SP - 693 EP - 694 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Pauly, F. A1 - Schroder, G. A1 - Ziemons, Karl A1 - Sievering, R. A1 - Halling, H. T1 - Preliminary studies of a micro-CT for a combined small animal PET/CT scanner JF - 2001 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - We are developing an X-ray computed tomography (CT) system which will be combined with a high resolution animal PET system. This permits acquisition of both molecular and anatomical images in a single machine. In particular the CT will also be utilized for the quantification of the animal PET data by providing accurate data for attenuation correction. A first prototype has been built using a commercially available plane silicon diode detector. A cone-beam reconstruction provides the images using the Feldkamp algorithm. First measurements with this system have been performed on a mouse. It could be shown that the CT setup fulfils all demands for a high quality image of the skeleton of the mouse. It is also suited for soft tissue measurements. To improve contrast and resolution and to acquire the X-ray energy further development of the system, especially the use of semiconductor detectors and iterative reconstruction algorithms are planned. Y1 - 2002 SN - 1082-3654 SP - 1605 EP - 1606 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Coincidence detection by digital processing of free-running sampled pulses JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Coincident events in two scintillator crystals coupled to photomultipliers (PMT) are detected by processing just the digital data of the recorded pulses. For this purpose the signals from both PMTs are continuously sampled by free-running ADCs at a sampling rate of 40 MHz. For each sampled pulse the starting time is determined by processing the pulse data. Even a fairly simple interpolating algorithm results in a FWHM of about 2 ns. Y1 - 2002 SN - 0168-9002 VL - 487 IS - 3 SP - 530 EP - 534 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - A PET system with free running ADCs JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - A small PET system has been built up with two multichannel photomultipliers, which are attached to a matrix of 64 single LSO crystals each. The signal from each multiplier is being sampled continuously by a 12 bit ADC at a sampling frequency of 40 MHz. In case of a scintillation pulse a subsequent FPGA sends the corresponding set of samples together with the channel information and a time mark to the host computer. The data transfer is performed with a rate of 20 MB/s. On the host all necessary information is extracted from the data. The pulse energy is determined, coincident events are detected and multiple hits within one matrix can be identified. In order to achieve a narrow time window the pulse starting time is refined further than the resolution of the time mark (=25 ns) would allow. This is possible by interpolating between the pulse samples. First data obtained from this system will be presented. The system is part of developments for a much larger system and has been created to study the feasibility and performance of the technique and the hardware architecture. Y1 - 2002 SN - 0168-9002 N1 - Proceedings of the 6th International Conference on Inorganic Scin tillators and their Use in Scientific and Industrial Applications VL - 486 IS - 1-2 SP - 18 EP - 21 ER -