TY - JOUR A1 - Grajewski, Matthias A1 - Kleefeld, Andreas T1 - Detecting and approximating decision boundaries in low-dimensional spaces JF - Numerical Algorithms N2 - A method for detecting and approximating fault lines or surfaces, respectively, or decision curves in two and three dimensions with guaranteed accuracy is presented. Reformulated as a classification problem, our method starts from a set of scattered points along with the corresponding classification algorithm to construct a representation of a decision curve by points with prescribed maximal distance to the true decision curve. Hereby, our algorithm ensures that the representing point set covers the decision curve in its entire extent and features local refinement based on the geometric properties of the decision curve. We demonstrate applications of our method to problems related to the detection of faults, to multi-criteria decision aid and, in combination with Kirsch’s factorization method, to solving an inverse acoustic scattering problem. In all applications we considered in this work, our method requires significantly less pointwise classifications than previously employed algorithms. KW - MCDA KW - Inverse scattering problem KW - Fault approximation KW - Fault detection Y1 - 2023 SN - 1572-9265 N1 - Corresponding author: Matthias Grajewski VL - 93 IS - 4 PB - Springer Science+Business Media CY - Dordrecht ER - TY - JOUR A1 - Kuchler, Timon A1 - Günthner, Roman A1 - Ribeiro, Andrea A1 - Hausinger, Renate A1 - Streese, Lukas A1 - Wöhnl, Anna A1 - Kesseler, Veronika A1 - Negele, Johanna A1 - Assali, Tarek A1 - Carbajo-Lozoya, Javier A1 - Lech, Maciej A1 - Adorjan, Kristina A1 - Stubbe, Hans Christian A1 - Hanssen, Henner A1 - Kotliar, Konstantin A1 - Haller, Berhard A1 - Heemann, Uwe A1 - Schmaderer, Christoph T1 - Persistent endothelial dysfunction in post-COVID-19 syndrome and its associations with symptom severity and chronic inflammation N2 - Background Post-COVID-19 syndrome (PCS) is a lingering disease with ongoing symptoms such as fatigue and cognitive impairment resulting in a high impact on the daily life of patients. Understanding the pathophysiology of PCS is a public health priority, as it still poses a diagnostic and treatment challenge for physicians. Methods In this prospective observational cohort study, we analyzed the retinal microcirculation using Retinal Vessel Analysis (RVA) in a cohort of patients with PCS and compared it to an age- and gender-matched healthy cohort (n = 41, matched out of n = 204). Measurements and main results PCS patients exhibit persistent endothelial dysfunction (ED), as indicated by significantly lower venular flicker-induced dilation (vFID; 3.42% ± 1.77% vs. 4.64% ± 2.59%; p = 0.02), narrower central retinal artery equivalent (CRAE; 178.1 [167.5–190.2] vs. 189.1 [179.4–197.2], p = 0.01) and lower arteriolar-venular ratio (AVR; (0.84 [0.8–0.9] vs. 0.88 [0.8–0.9], p = 0.007). When combining AVR and vFID, predicted scores reached good ability to discriminate groups (area under the curve: 0.75). Higher PCS severity scores correlated with lower AVR (R = − 0.37 p = 0.017). The association of microvascular changes with PCS severity were amplified in PCS patients exhibiting higher levels of inflammatory parameters. Conclusion Our results demonstrate that prolonged endothelial dysfunction is a hallmark of PCS, and impairments of the microcirculation seem to explain ongoing symptoms in patients. As potential therapies for PCS emerge, RVA parameters may become relevant as clinical biomarkers for diagnosis and therapy management. KW - Endothelial dysfunction KW - Long COVID KW - Post-COVID-19 syndrome KW - retinal microvasculature Y1 - 2023 U6 - http://dx.doi.org/10.1007/s10456-023-09885-6 N1 - Corresponding author: Christoph Schmaderer VL - 26 SP - 547 EP - 563 PB - Springer Nature CY - Dordrecht ER - TY - RPRT A1 - Siegert, Petra A1 - Bongaerts, Johannes A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Selmer, Thorsten T1 - Abschlussbericht zum Projekt zur Überwachung biotechnologischer Prozesse mittels Diacetyl-/Acetoin-Biosensor und Evaluierung von Acetoin-Reduktasen zur Verwendung in Biotransformationen Y1 - 2022 N1 - Laufzeit: 01.01.2016 – 31.12.2019 (verlängert bis 31.12.2020) Förderkennzeichen: 322-8.03.04.02-FH-Struktur 2016/02 Gefördert durch: Ministerium für Innovation, Wissenschaft und Forschung des Landes Nordrhein-Westfalen CY - Aachen ER - TY - CHAP A1 - Klöser, Lars A1 - Büsgen, André A1 - Kohl, Philipp A1 - Kraft, Bodo A1 - Zündorf, Albert ED - Conte, Donatello ED - Fred, Ana ED - Gusikhin, Oleg ED - Sansone, Carlo T1 - Explaining relation classification models with semantic extents T2 - DeLTA 2023: Deep Learning Theory and Applications N2 - In recent years, the development of large pretrained language models, such as BERT and GPT, significantly improved information extraction systems on various tasks, including relation classification. State-of-the-art systems are highly accurate on scientific benchmarks. A lack of explainability is currently a complicating factor in many real-world applications. Comprehensible systems are necessary to prevent biased, counterintuitive, or harmful decisions. We introduce semantic extents, a concept to analyze decision patterns for the relation classification task. Semantic extents are the most influential parts of texts concerning classification decisions. Our definition allows similar procedures to determine semantic extents for humans and models. We provide an annotation tool and a software framework to determine semantic extents for humans and models conveniently and reproducibly. Comparing both reveals that models tend to learn shortcut patterns from data. These patterns are hard to detect with current interpretability methods, such as input reductions. Our approach can help detect and eliminate spurious decision patterns during model development. Semantic extents can increase the reliability and security of natural language processing systems. Semantic extents are an essential step in enabling applications in critical areas like healthcare or finance. Moreover, our work opens new research directions for developing methods to explain deep learning models. KW - Relation classification KW - Natural language processing KW - Natural language understanding KW - Information extraction KW - Trustworthy artificial intelligence Y1 - 2023 SN - 978-3-031-39058-6 (Print) SN - 978-3-031-39059-3 (Online) U6 - http://dx.doi.org/10.1007/978-3-031-39059-3_13 N1 - 4th International Conference, DeLTA 2023, Rome, Italy, July 13–14, 2023. SP - 189 EP - 208 PB - Springer CY - Cham ER - TY - CHAP A1 - Kohl, Philipp A1 - Freyer, Nils A1 - Krämer, Yoka A1 - Werth, Henri A1 - Wolf, Steffen A1 - Kraft, Bodo A1 - Meinecke, Matthias A1 - Zündorf, Albert ED - Conte, Donatello ED - Fred, Ana ED - Gusikhin, Oleg ED - Sansone, Carlo T1 - ALE: a simulation-based active learning evaluation framework for the parameter-driven comparison of query strategies for NLP T2 - Deep Learning Theory and Applications. DeLTA 2023. Communications in Computer and Information Science N2 - Supervised machine learning and deep learning require a large amount of labeled data, which data scientists obtain in a manual, and time-consuming annotation process. To mitigate this challenge, Active Learning (AL) proposes promising data points to annotators they annotate next instead of a subsequent or random sample. This method is supposed to save annotation effort while maintaining model performance. However, practitioners face many AL strategies for different tasks and need an empirical basis to choose between them. Surveys categorize AL strategies into taxonomies without performance indications. Presentations of novel AL strategies compare the performance to a small subset of strategies. Our contribution addresses the empirical basis by introducing a reproducible active learning evaluation (ALE) framework for the comparative evaluation of AL strategies in NLP. The framework allows the implementation of AL strategies with low effort and a fair data-driven comparison through defining and tracking experiment parameters (e.g., initial dataset size, number of data points per query step, and the budget). ALE helps practitioners to make more informed decisions, and researchers can focus on developing new, effective AL strategies and deriving best practices for specific use cases. With best practices, practitioners can lower their annotation costs. We present a case study to illustrate how to use the framework. KW - Active learning KW - Query learning KW - Natural language processing KW - Deep learning KW - Reproducible research Y1 - 2023 SN - 978-3-031-39058-6 (Print) SN - 978-3-031-39059-3 (Online) U6 - http://dx.doi.org/978-3-031-39059-3 N1 - 4th International Conference, DeLTA 2023, Rome, Italy, July 13–14, 2023. SP - 235 EP - 253 PB - Springer CY - Cham ER - TY - CHAP A1 - Büsgen, André A1 - Klöser, Lars A1 - Kohl, Philipp A1 - Schmidts, Oliver A1 - Kraft, Bodo A1 - Zündorf, Albert ED - Cuzzocrea, Alfredo ED - Gusikhin, Oleg ED - Hammoudi, Slimane ED - Quix, Christoph T1 - From cracked accounts to fake IDs: user profiling on German telegram black market channels T2 - Data Management Technologies and Applications N2 - Messenger apps like WhatsApp and Telegram are frequently used for everyday communication, but they can also be utilized as a platform for illegal activity. Telegram allows public groups with up to 200.000 participants. Criminals use these public groups for trading illegal commodities and services, which becomes a concern for law enforcement agencies, who manually monitor suspicious activity in these chat rooms. This research demonstrates how natural language processing (NLP) can assist in analyzing these chat rooms, providing an explorative overview of the domain and facilitating purposeful analyses of user behavior. We provide a publicly available corpus of annotated text messages with entities and relations from four self-proclaimed black market chat rooms. Our pipeline approach aggregates the extracted product attributes from user messages to profiles and uses these with their sold products as features for clustering. The extracted structured information is the foundation for further data exploration, such as identifying the top vendors or fine-granular price analyses. Our evaluation shows that pretrained word vectors perform better for unsupervised clustering than state-of-the-art transformer models, while the latter is still superior for sequence labeling. KW - Clustering KW - Natural language processing KW - Information extraction KW - Profile extraction KW - Text mining Y1 - 2023 SN - 978-3-031-37889-8 (Print) SN - 978-3-031-37890-4 (Online) U6 - http://dx.doi.org/10.1007/978-3-031-37890-4_9 N1 - 10th International Conference, DATA 2021, Virtual Event, July 6–8, 2021, and 11th International Conference, DATA 2022, Lisbon, Portugal, July 11-13, 2022 SP - 176 EP - 202 PB - Springer CY - Cham ER - TY - JOUR A1 - Vögele, Stefan A1 - Josyabhatla, Vishnu Teja A1 - Ball, Christopher A1 - Rhoden, Imke A1 - Grajewski, Matthias A1 - Rübbelke, Dirk A1 - Kuckshinrichs, Wilhelm T1 - Robust assessment of energy scenarios from stakeholders' perspectives JF - Energy N2 - Using scenarios is vital in identifying and specifying measures for successfully transforming the energy system. Such transformations can be particularly challenging and require the support of a broader set of stakeholders. Otherwise, there will be opposition in the form of reluctance to adopt the necessary technologies. Usually, processes for considering stakeholders' perspectives are very time-consuming and costly. In particular, there are uncertainties about how to deal with modifications in the scenarios. In principle, new consulting processes will be required. In our study, we show how multi-criteria decision analysis can be used to analyze stakeholders' attitudes toward transition paths. Since stakeholders differ regarding their preferences and time horizons, we employ a multi-criteria decision analysis approach to identify which stakeholders will support or oppose a transition path. We provide a flexible template for analyzing stakeholder preferences toward transition paths. This flexibility comes from the fact that our multi-criteria decision aid-based approach does not involve intensive empirical work with stakeholders. Instead, it involves subjecting assumptions to robustness analysis, which can help identify options to influence stakeholders' attitudes toward transitions. Y1 - 2023 U6 - http://dx.doi.org/10.1016/j.energy.2023.128326 SN - 1873-6785 (Online) SN - 0360-5442 (Print) IS - In Press, Article 128326 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Waldvogel, Janice A1 - Freyler, Kathrin A1 - Helm, Michael A1 - Monti, Elena A1 - Stäudle, Benjamin A1 - Gollhofer, Albert A1 - Narici, Marco V. A1 - Ritzmann, Ramona A1 - Albracht, Kirsten T1 - Changes in gravity affect neuromuscular control, biomechanics, and muscle-tendon mechanics in energy storage and dissipation tasks JF - Journal of Applied Physiology N2 - This study evaluates neuromechanical control and muscle-tendon interaction during energy storage and dissipation tasks in hypergravity. During parabolic flights, while 17 subjects performed drop jumps (DJs) and drop landings (DLs), electromyography (EMG) of the lower limb muscles was combined with in vivo fascicle dynamics of the gastrocnemius medialis, two-dimensional (2D) kinematics, and kinetics to measure and analyze changes in energy management. Comparisons were made between movement modalities executed in hypergravity (1.8 G) and gravity on ground (1 G). In 1.8 G, ankle dorsiflexion, knee joint flexion, and vertical center of mass (COM) displacement are lower in DJs than in DLs; within each movement modality, joint flexion amplitudes and COM displacement demonstrate higher values in 1.8 G than in 1 G. Concomitantly, negative peak ankle joint power, vertical ground reaction forces, and leg stiffness are similar between both movement modalities (1.8 G). In DJs, EMG activity in 1.8 G is lower during the COM deceleration phase than in 1 G, thus impairing quasi-isometric fascicle behavior. In DLs, EMG activity before and during the COM deceleration phase is higher, and fascicles are stretched less in 1.8 G than in 1 G. Compared with the situation in 1 G, highly task-specific neuromuscular activity is diminished in 1.8 G, resulting in fascicle lengthening in both movement modalities. Specifically, in DJs, a high magnitude of neuromuscular activity is impaired, resulting in altered energy storage. In contrast, in DLs, linear stiffening of the system due to higher neuromuscular activity combined with lower fascicle stretch enhances the buffering function of the tendon, and thus the capacity to safely dissipate energy. KW - electromyography KW - locomotion KW - overload KW - stretch-shortening cycle KW - ultrasound Y1 - 2023 U6 - http://dx.doi.org/10.1152/japplphysiol.00279.2022 SN - 1522-1601 (Onlineausgabe) SN - 8750-7587 (Druckausgabe) VL - 134 IS - 1 SP - 190 EP - 202 PB - American Physiological Society CY - Bethesda, Md. ER - TY - CHAP A1 - Engelmann, Ulrich M. A1 - Baumann, Martin ED - Lindinger, Markus ED - Bartsch, Oliver T1 - Moderationsexpertise - das Mindset T2 - IT-Servicemanagement N2 - Teamsitzungen, Arbeitsgruppentreffen, Kickoffs und Meetings – sie alle werden mit dem Ziel durchgeführt, innerhalb einer vorgegebenen Zeitspanne ein gemeinsames Arbeitsziel zu erreichen. Damit die Zielerreichung auch bei komplexeren Arbeitsaufträgen nicht vom Zufall abhängt, empfiehlt es sich, die Leitung des Ablaufs einem Moderator zu übertragen. In diesem Beitrag einer dreiteiligen Serie wird beschrieben, über welches Mindset der Moderator verfügen sollte, welche grundsätzlichen Methoden hilfreich sind und was bei der Onlinemoderation im Besonderen zu beachten ist. Y1 - 2023 SN - 978-3-8249-1154-7 SP - Kapitel 05530 PB - TÜV-Verlag CY - Köln ET - 54. Update ER - TY - JOUR A1 - Rabehi, Amine A1 - Garlan, Benjamin A1 - Achtsnicht, Stefan A1 - Krause, Hans-Joachim A1 - Offenhäusser, Andreas A1 - Ngo, Kieu A1 - Neveu, Sophie A1 - Graff-Dubois, Stephanie A1 - Kokabi, Hamid T1 - Magnetic detection structure for Lab-on-Chip applications based on the frequency mixing technique JF - Sensors N2 - A magnetic frequency mixing technique with a set of miniaturized planar coils was investigated for use with a completely integrated Lab-on-Chip (LoC) pathogen sensing system. The system allows the detection and quantification of superparamagnetic beads. Additionally, in terms of magnetic nanoparticle characterization ability, the system can be used for immunoassays using the beads as markers. Analytical calculations and simulations for both excitation and pick-up coils are presented; the goal was to investigate the miniaturization of simple and cost-effective planar spiral coils. Following these calculations, a Printed Circuit Board (PCB) prototype was designed, manufactured, and tested for limit of detection, linear response, and validation of theoretical concepts. Using the magnetic frequency mixing technique, a limit of detection of 15 µg/mL of 20 nm core-sized nanoparticles was achieved without any shielding. KW - Lab-on-Chip KW - magnetic sensing KW - frequency mixing KW - superparamagnetic nanoparticles KW - magnetic beads Y1 - 2018 U6 - http://dx.doi.org/10.3390/s18061747 SN - 1424-8220 VL - 18 IS - 6 PB - MDPI CY - Basel ER - TY - CHAP A1 - Engelmann, Ulrich M. A1 - Baumann, Martin ED - Thomann, Hermann ED - Träger, Thomas T1 - Moderationsexpertise für QMBs – das Mindset T2 - Qualitätsmanagement in Dienstleistungsunternehmen N2 - Teamsitzungen, Arbeitsgruppentreffen, Kickoffs und Meetings – sie alle werden mit dem Ziel durchgeführt, innerhalb einer vorgegebenen Zeitspanne ein gemeinsames Arbeitsziel zu erreichen. Damit die Zielerreichung auch bei komplexeren Arbeitsaufträgen nicht vom Zufall abhängt, empfiehlt es sich, die Leitung des Ablaufs einem Moderator zu übertragen. In diesem Beitrag einer mehrteiligen Serie wird beschrieben, über welches Mindset der Moderator verfügen sollte, welche grundsätzlichen Methoden hilfreich sind und was bei der Onlinemoderation im Besonderen zu beachten ist. Y1 - 2023 SN - 978-3-8249-0473-0 SP - Kapitel 08630 PB - TÜV-Verlag CY - Köln ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Schönenborn, Kristina A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim T1 - Measurement of the magnetophoretic velocity of different superparamagnetic beads JF - Journal of Magnetism and Magnetic Materials N2 - The movement of magnetic beads due to a magnetic field gradient is of great interest in different application fields. In this report we present a technique based on a magnetic tweezers setup to measure the velocity factor of magnetically actuated individual superparamagnetic beads in a fluidic environment. Several beads can be tracked simultaneously in order to gain and improve statistics. Furthermore we show our results for different beads with hydrodynamic diameters between 200 and 1000 nm from diverse manufacturers. These measurement data can, for example, be used to determine design parameters for a magnetic separation system, like maximum flow rate and minimum separation time, or to select suitable beads for fixed experimental requirements. KW - magnetophoretic velocity KW - superparamagnetic bead KW - magnetic tweezers KW - magnetic separation KW - magnetic actuation Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.jmmm.2018.10.066 SN - 0304-8853 VL - 477 IS - 1 SP - 244 EP - 248 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Tödter, Julia A1 - Niehues, Julia A1 - Telöken, Matthias A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim A1 - Schröper, Florian T1 - 3D printed modular immunofiltration columns for frequency mixing-based multiplex magnetic immunodetection JF - Sensors N2 - For performing point-of-care molecular diagnostics, magnetic immunoassays constitute a promising alternative to established enzyme-linked immunosorbent assays (ELISA) because they are fast, robust and sensitive. Simultaneous detection of multiple biomolecular targets from one body fluid sample is desired. The aim of this work is to show that multiplex magnetic immunodetection based on magnetic frequency mixing by means of modular immunofiltration columns prepared for different targets is feasible. By calculations of the magnetic response signal, the required spacing between the modules was determined. Immunofiltration columns were manufactured by 3D printing and antibody immobilization was performed in a batch approach. It was shown experimentally that two different target molecules in a sample solution could be individually detected in a single assaying step with magnetic measurements of the corresponding immobilization filters. The arrangement order of the filters and of a negative control did not influence the results. Thus, a simple and reliable approach to multi-target magnetic immunodetection was demonstrated. Y1 - 2019 U6 - http://dx.doi.org/10.3390/s19010148 SN - 1424-8220 VL - 19 IS - 1 PB - MDPI CY - Basel ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Pourshahidi, Ali Mohammad A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim T1 - Multiplex detection of different magnetic beads using frequency scanning in magnetic frequency mixing technique JF - Sensors N2 - In modern bioanalytical methods, it is often desired to detect several targets in one sample within one measurement. Immunological methods including those that use superparamagnetic beads are an important group of techniques for these applications. The goal of this work is to investigate the feasibility of simultaneously detecting different superparamagnetic beads acting as markers using the magnetic frequency mixing technique. The frequency of the magnetic excitation field is scanned while the lower driving frequency is kept constant. Due to the particles’ nonlinear magnetization, mixing frequencies are generated. To record their amplitude and phase information, a direct digitization of the pickup-coil’s signal with subsequent Fast Fourier Transformation is performed. By synchronizing both magnetic beads using frequency scanning in magnetic frequency mixing technique magnetic fields, a stable phase information is gained. In this research, it is shown that the amplitude of the dominant mixing component is proportional to the amount of superparamagnetic beads inside a sample. Additionally, it is shown that the phase does not show this behaviour. Excitation frequency scans of different bead types were performed, showing different phases, without correlation to their diverse amplitudes. Two commercially available beads were selected and a determination of their amount in a mixture is performed as a demonstration for multiplex measurements. KW - frequency mixing magnetic detection KW - magnetic sandwich immunoassay KW - multiparametric immunoassays Y1 - 2019 U6 - http://dx.doi.org/10.3390/s19112599 SN - 1424-8220 VL - 19 IS - 11 PB - MDPI CY - Basel ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Neuendorf, Christian A1 - Faßbender, Tobias A1 - Nölke, Greta A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim A1 - Schröper, Florian T1 - Sensitive and rapid detection of cholera toxin subunit B using magnetic frequency mixing detection JF - Plos One N2 - Cholera is a life-threatening disease caused by the cholera toxin (CT) as produced by some Vibrio cholerae serogroups. In this research we present a method which directly detects the toxin’s B subunit (CTB) in drinking water. For this purpose we performed a magnetic sandwich immunoassay inside a 3D immunofiltration column. We used two different commercially available antibodies to capture CTB and for binding to superparamagnetic beads. ELISA experiments were performed to select the antibody combination. The beads act as labels for the magnetic frequency mixing detection technique. We show that the limit of detection depends on the type of magnetic beads. A nonlinear Hill curve was fitted to the calibration measurements by means of a custom-written python software. We achieved a sensitive and rapid detection of CTB within a broad concentration range from 0.2 ng/ml to more than 700 ng/ml. Y1 - 2019 U6 - http://dx.doi.org/10.1371/journal.pone.0219356 SN - 1932-6203 VL - 14 IS - 7 PB - Plos CY - San Francisco ER - TY - THES A1 - Achtsnicht, Stefan T1 - Multiplex-Magnetdetektion von superparamagnetischen Beads zur Identifizierung von Trinkwasserkontaminationen N2 - Die qualitative und quantitative Detektion von Zielsubstanzen innerhalb einer wässrigen Probe ist für viele Fragestellungen von Interesse, etwa bei der Detektion von Kontaminationen in Trinkwasser in Krisensituationen. Hierbei ist es nicht nur wichtig, dass Pathogene möglichst sensitiv detektiert werden können, sondern auch, dass die Analyse schnell erfolgt, um Betroffenen im Katastrophenfall zügig sicheres Trinkwasser zu Verfügung stellen zu können. Da bei einem solchen Szenario nicht von einer in der Nähe befindlichen funktionierenden Laborinfrastruktur ausgegangen werden kann, ist es wichtig, dass die Messung direkt vor Ort erfolgen kann. Im Rahmen dieser Arbeit wurde untersucht, ob eine derartige Schnellanalytik mithilfe von superparamagnetischen Beads (MBs) und der magnetischen Frequenzmischtechnik möglich ist. Dabei werden die MBs mit Hilfe von primären Antikörpern an die Zielsubstanz gebunden und mit sekundären Antikörpern an die Poren-Oberfläche eines Polyethylen-Filters fixiert (Sandwich-Immunoassay). So kann die Quantifizierung der Zielsubstanz auf eine magnetische Messung der immobilisierten MB-Marker zurückgeführt werden. Die magnetische Frequenzmischtechnik basiert auf der Anregung der Probe mit Magnetfeldern zweier verschiedener Frequenzen. Die durch die nichtlineare Magnetisierungsform der superparamagnetischen MBs entstehenden Mischfrequenzen werden typischerweise mithilfe einer zweistufigen Lock-in-Detektion analysiert (analoge Demodulation), die in einem Magnetreader als Handheldgerät realisiert wurde. Zusätzlich zu dieser Technik wurde das Prinzip der direkten Digitalisierung des gesamten Antwortsignals mit anschließender Fourier-Analyse der erzeugten Mischfrequenzen experimentell umgesetzt, um die Amplituden und Phasen mehrerer Mischfrequenzen simultan zu erfassen. Eine Möglichkeit zur Sensitivitätssteigerung ist die magnetische Aufkonzentration, indem vor der magnetischen Analyse eine Separation der MBs aus einem größeren Probenvolumen mittels magnetischem Feldgradienten durchgeführt wird. Zur Charakterisierung verschiedener kommerzieller MBs hinsichtlich ihrer magnetischen Separierbarkeit wurde ein Aufbau zur Messung ihrer magnetophoretischen Beweglichkeiten realisiert und ihre Geschwindigkeiten im Gradientenfeld mikroskopisch gemessen.Da eine Probe oftmals nicht nur auf eine einzige Zielsubstanz, sondern simultan auf mehrere verschiedene Pathogene hin untersucht werden soll, wurden verschiedene Ansätze entwickelt und getestet, die einen solchen multiparametrischen magnetischen Immunoassay ermöglichen. Einerseits wurde eine räumliche Separation der Bindungsbereiche für verschiedene Zielsubstanzen realisiert, die sequentiell ausgewertet werden können. Andererseits wurde die Unterscheidung von verschiedenen Zielsubstanzen anhand der Charakteristika der an sie gebundenen, verschieden funktionalisierten MB-Typen untersucht. Für eine solche Unterscheidung wurde zum einen die Anregefrequenz der magnetischen Frequenzmischtechnik während einer Messung variiert. Damit konnte gezeigt werden, dass sich verschiedene MB-Sorten anhand der Phase ihrer Frequenzmischsignale voneinander unterscheiden lassen. Weiterhin wurde gezeigt, dass sich der Signalverlauf einer binären Mischung zweier verschiedener MB-Typen als gradueller Übergang der Verläufe der beiden reinen MB-Lösungen ergibt. Eine weitere Analysemethode für einen multiparametrischen Immunoassay besteht darin, ein zusätzliches einstellbares statisches magnetisches Offsetfeld zu verwenden. Hierfür wurden mehrere Aufbauten auf Basis von Permanent- und Elektromagneten simuliert, konstruiert und charakterisiert. Mithilfe von Simulationen konnte gezeigt werden, dass eine auf diesem Verfahren beruhende Unterscheidung für MBs mit unterschiedlichen magnetischen Partikelmomenten möglich ist. Als direkte Anwendung des hier entwickelten Magnetreaders in Zusammenspiel mit der digitalen Demodulation wurde ein magnetischer Assay gegen die B-Untereinheit des Choleratoxins in Trinkwasser mit einem niedrigen Detektionslimit von 0,2 ng/ml demonstriert. N2 - The qualitative and quantitative detection of target substances in an aqueous sample is of interest for many questions, for example in the detection of contaminations in drinking water in crisis situations. It is not only important that pathogens can be detected with highest possible sensitivity, but also that the analysis is carried out quickly so that safe drinking water can be provided in the event of a disaster. During such a scenario one cannot rely on a functioning laboratory infrastructure nearby. Therefore it is important that the measurement can be carried out directly on site. Within the scope of this work, it was investigated whether such a quick analysis can be performed using superparamagnetic beads (MBs) and the magnetic frequency mixing technique. The MBs are bound to the target substance with the aid of primary antibodies and fixed to the pore surfaces of a polyethylene filter with secondary antibodies (sandwich immunoassay). The quantification of the target substance can thus be traced back to a magnetic measurement of the immobilized MB markers. The magnetic frequency mixing technique is based on the excitation of the sample with magnetic fields of two different frequencies. The mixing frequencies generated due to the non-linear shape of the magnetization of the superparamagnetic MBs are typically analyzed using a two-stage Lock-in detection (analog demodulation), which was implemented in a magnetic reader as a handheld device. In addition to this technique, the principle of direct digitization of the entire response signal with subsequent Fourier analysis of the generated mixing frequencies was experimentally implemented in order to simultaneously record the amplitudes and phases of several mixing frequencies. One possibility for increasing the sensitivity is magnetic concentration. In that case, the MBs are separated from a larger sample volume by means of a magnetic field gradient before the magnetic analysis. To characterize various commercial MBs with regard to their magnetic separability, a setup for measuring their magnetophoretic mobility was implemented and their velocities in the gradient field were measured with an optical microscope.Often, a sample has to be examined not only for a single target substance, but for several different pathogens simultaneously. Various approaches have been developed and tested which enable such a multiparametric magnetic immunoassay. On the one hand, a spatial separation of the binding areas for different target substances was realized, which can be evaluated sequentially. On the other hand, a distinction among different target substances based on the magnetic characteristics of their attached different MB types was examined. For this discrimination, the excitation frequency of the magnetic frequency mixing technology was varied during measurement. It is shown that different MB types can be distinguished from one another based on the phase of their frequency mixing signals. The signal curve of a binary mixture of two different MB types is obtained as a gradual transition of the curves of the two pure MB solutions. Another method of analysis for a multiparametric immunoassay is based on an additional adjustable static magnetic offset field. For this purpose, several setups based on permanent magnets and electromagnets were simulated, designed and characterized. The simulations show that a distinction based on this method is possible for MBs with different magnetic particle moments. As a direct application of the developed magnetic reader in conjunction with digital demodulation, a magnetic assay against the B subunit of cholera toxin in drinking water was demonstrated, and a low detection limit of 0.2 ng/ml was achieved. KW - Choleratoxin B KW - Trinkwassersicherheit KW - cholera toxin B KW - drinking water safety KW - magnetic frequency mixing technique Y1 - 2020 U6 - http://dx.doi.org/10.18154/RWTH-2020-12052 N1 - Dissertation, RWTH Aachen University, 2020 ER - TY - JOUR A1 - Janus, Kevin Alexander A1 - Achtsnicht, Stefan A1 - Tempel, Laura A1 - Drinic, Aleksaner A1 - Kopp, Alexander A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Influence of fibroin membrane composition and curing parameters on the performance of a biodegradable enzymatic biosensor manufactured from Silicon-Free Carbon JF - Physica status solidi : pss. A, Applications and materials science N2 - Herein, fibroin, polylactide (PLA), and carbon are investigated for their suitability as biocompatible and biodegradable materials for amperometric biosensors. For this purpose, screen-printed carbon electrodes on the biodegradable substrates fibroin and PLA are modified with a glucose oxidase membrane and then encapsulated with the biocompatible material Ecoflex. The influence of different curing parameters of the carbon electrodes on the resulting biosensor characteristics is studied. The morphology of the electrodes is investigated by scanning electron microscopy, and the biosensor performance is examined by amperometric measurements of glucose (0.5–10 mM) in phosphate buffer solution, pH 7.4, at an applied potential of 1.2 V versus a Ag/AgCl reference electrode. Instead of Ecoflex, fibroin, PLA, and wound adhesive are tested as alternative encapsulation compounds: a series of swelling tests with different fibroin compositions, PLA, and Ecoflex has been performed before characterizing the most promising candidates by chronoamperometry. Therefore, the carbon electrodes are completely covered with the particular encapsulation material. Chronoamperometric measurements with H2O2 concentrations between 0.5 and 10 mM enable studying the leakage current behavior. KW - amperometric biosensors KW - biocompatible KW - biodegradabl KW - encapsulation materials KW - fibroin Y1 - 2023 U6 - http://dx.doi.org/10.1002/pssa.202300081 SN - 1862-6300 (Print) SN - 1862-6319 (Online) N1 - Corresponding author: Michael J. Schöning VL - 220 IS - 22 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Heieis, Jule A1 - Böcker, Jonas A1 - D'Angelo, Olfa A1 - Mittag, Uwe A1 - Albracht, Kirsten A1 - Schönau, Eckhard A1 - Meyer, Andreas A1 - Voigtmann, Thomas A1 - Rittweger, Jörn T1 - Curvature of gastrocnemius muscle fascicles as function of muscle–tendon complex length and contraction in humans JF - Physiological Reports N2 - It has been shown that muscle fascicle curvature increases with increasing contraction level and decreasing muscle–tendon complex length. The analyses were done with limited examination windows concerning contraction level, muscle–tendon complex length, and/or intramuscular position of ultrasound imaging. With this study we aimed to investigate the correlation between fascicle arching and contraction, muscle–tendon complex length and their associated architectural parameters in gastrocnemius muscles to develop hypotheses concerning the fundamental mechanism of fascicle curving. Twelve participants were tested in five different positions (90°/105°*, 90°/90°*, 135°/90°*, 170°/90°*, and 170°/75°*; *knee/ankle angle). They performed isometric contractions at four different contraction levels (5%, 25%, 50%, and 75% of maximum voluntary contraction) in each position. Panoramic ultrasound images of gastrocnemius muscles were collected at rest and during constant contraction. Aponeuroses and fascicles were tracked in all ultrasound images and the parameters fascicle curvature, muscle–tendon complex strain, contraction level, pennation angle, fascicle length, fascicle strain, intramuscular position, sex and age group were analyzed by linear mixed effect models. Mean fascicle curvature of the medial gastrocnemius increased with contraction level (+5 m−1 from 0% to 100%; p = 0.006). Muscle–tendon complex length had no significant impact on mean fascicle curvature. Mean pennation angle (2.2 m−1 per 10°; p < 0.001), inverse mean fascicle length (20 m−1 per cm−1; p = 0.003), and mean fascicle strain (−0.07 m−1 per +10%; p = 0.004) correlated with mean fascicle curvature. Evidence has also been found for intermuscular, intramuscular, and sex-specific intramuscular differences of fascicle curving. Pennation angle and the inverse fascicle length show the highest predictive capacities for fascicle curving. Due to the strong correlations between pennation angle and fascicle curvature and the intramuscular pattern of curving we suggest for future studies to examine correlations between fascicle curvature and intramuscular fluid pressure. KW - biomechanics KW - connective tissue KW - physiology KW - ultrasound Y1 - 2023 U6 - http://dx.doi.org/10.14814/phy2.15739 SN - 2051-817X VL - 11 IS - 11 SP - e15739, Seite 1-11 PB - Wiley ER - TY - JOUR A1 - Rhoden, Imke A1 - Ball, Christopher Stephen A1 - Grajewski, Matthias A1 - Kuckshinrich, Wilhelm T1 - Reverse engineering of stakeholder preferences – A multi-criteria assessment of the German passenger car sector JF - Renewable and Sustainable Energy Reviews N2 - Germany is a frontrunner in setting frameworks for the transition to a low-carbon system. The mobility sector plays a significant role in this shift, affecting different people and groups on multiple levels. Without acceptance from these stakeholders, emission targets are out of reach. This research analyzes how the heterogeneous preferences of various stakeholders align with the transformation of the mobility sector, looking at the extent to which the German transformation paths are supported and where stakeholders are located. Under the research objective of comparing stakeholders' preferences to identify which car segments require additional support for a successful climate transition, a status quo of stakeholders and car performance criteria is the foundation for the analysis. Stakeholders' hidden preferences hinder the derivation of criteria weightings from stakeholders; therefore, a ranking from observed preferences is used. This study's inverse multi-criteria decision analysis means that weightings can be predicted and used together with a recalibrated performance matrix to explore future preferences toward car segments. Results show that stakeholders prefer medium-sized cars, with the trend pointing towards the increased potential for alternative propulsion technologies and electrified vehicles. These insights can guide the improved targeting of policy supporting the energy and mobility transformation. Additionally, the method proposed in this work can fully handle subjective approaches while incorporating a priori information. A software implementation of the proposed method completes this work and is made publicly available. KW - Regionalization KW - Multi-criteria decision analysis KW - Preference assessment KW - E-Mobility KW - Mobility transition Y1 - 2023 U6 - http://dx.doi.org/10.1016/j.rser.2023.113352 SN - 1364-0321 VL - 181 IS - July 2023 SP - Article number: 113352 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Stollenwerk, Dominik A1 - Franzke, Till A1 - Maurer, Florian A1 - Reinkensmeier, Sebastian A1 - Kim, Franken A1 - Tambornino, Philipp A1 - Haas, Florian A1 - Rieke, Christian A1 - Hermanuz, Andreas A1 - Borchert, Jörg A1 - Ritz, Thomas A1 - Sander, Volker ED - Proff, Heike T1 - Smarte Ladesäulen : Netz- und Marktdienliches öffentliches Laden T2 - Towards the New Normal in Mobility : Technische und betriebswirtschaftliche Aspekte N2 - Stand 01.01.2022 sind in Deutschland 618.460 elektrisch angetriebene KFZ zugelassen. Insgesamt sind derzeit 48.540.878 KFZ zugelassen, was einer Elektromobilitätsquote von ca. 1,2 % entspricht. Derzeit werden Elektromobile über Ladestationen oder Steckdosen mit dem Stromnetz verbunden und üblicherweise mit der vollen Ladekapazität des Anschlusses aufgeladen, bis das Batteriemanagementsystem des Fahrzeugs abhängig vom Ladezustand der Batterie die Ladeleistung reduziert. Y1 - 2023 SN - 978-3-658-39437-0 (Print) SN - 978-3-658-39438-7 (Online) U6 - http://dx.doi.org/10.1007/978-3-658-39438-7_18 SP - 287 EP - 304 PB - Springer Gabler CY - Wiesbaden ER -