TY - JOUR A1 - Vlasov, Y. G. A1 - Mourzina, Y. G. A1 - Legin, A. V. A1 - Ermelenko, Y. E. A1 - Schubert, J. A1 - Schöning, Michael Josef A1 - Lüth, H. T1 - Solid-state thin film sensors based on chalcogenide materials prepared by planar technology and pulsed laser deposition JF - Russian Journal of Applied Chemistry. 75 (2002), H. 3 Y1 - 2002 SN - 1070-4272 SP - 351 EP - 356 ER - TY - JOUR A1 - Vahidpour, Farnoosh A1 - Oberländer, Jan A1 - Schöning, Michael Josef T1 - Flexible Calorimetric Gas Sensors for Detection of a Broad Concentration Range of Gaseous Hydrogen Peroxide: A Step Forward to Online Monitoring of Food-Package Sterilization Processes JF - Phys. Status Solidi A N2 - In this study, flexible calorimetric gas sensors are developed for specificdetection of gaseous hydrogen peroxide (H₂O₂) over a wide concentrationrange, which is used in sterilization processes for aseptic packaging industry.The flexibility of these sensors is an advantage for identifying the chemical components of the sterilant on the corners of the food boxes, so-called “coldspots”, as critical locations in aseptic packaging, which are of great importance. These sensors are fabricated on flexible polyimide films by means of thin-film technique. Thin layers of titanium and platinum have been deposited on polyimide to define the conductive structures of the sensors. To detect the high-temperature evaporated H₂O₂, a differential temperature set-up is proposed. The sensors are evaluated in a laboratory-scaled sterilizationsystem to simulate the sterilization process. The concentration range of the evaporated H₂O₂ from 0 to 7.7% v/v was defined and the sensors have successfully detected high as well as low H₂O₂ concentrations with a sensitivity of 5.04 °C/% v/v. The characterizations of the sensors confirm their precise fabrication, high sensitivity and the novelty of low H₂O₂ concentration detections for future inline monitoring of food-package sterilization. Y1 - 2018 U6 - http://dx.doi.org/10.1002/pssa.201800044 VL - 215 IS - 15 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Turek, Monika A1 - Schöning, Michael Josef A1 - Kloock, Joachim P. A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Krüger, Peter A1 - Keusgen, Michael T1 - Herstellung und Charakterisierung eines hybriden Sensorarrays auf Halbleiterbasis für die Umweltanalytik JF - Sensoren und Messsysteme 2008 : 14. Fachtagung Ludwigsburg, 11. und 12. März 2008 / VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2008 SN - 978-3-18-092011-5 N1 - VDI-Berichte ; 2011 ; Sensoren und Messsysteme 2008, 14. GMA/ITG-Fachtagung, VDI/VDE- Gesellschaft Mess- und Automatisierungstechnik, + CD-ROM, Ludwigsburg, DE, 11.-12. Mar, 2008 SP - 803 EP - 810 PB - VDI-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Turek, Monika A1 - Ketterer, Lothar A1 - Claßen, Melanie A1 - Berndt, Heinz A1 - Elbers, Gereon A1 - Krüger, Peter A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Development and Electrochemical Investigations of an EIS-(Electrolyte-Insulator-Semiconductor) based Biosensor for Cyanide Detection JF - Sensors Y1 - 2007 SN - 1424-8220 VL - 7 IS - 8 SP - 1415 EP - 1426 ER - TY - JOUR A1 - Turek, Monik A1 - Heiden, Wolfgang A1 - Guo, Sharon A1 - Riesen, Alfred A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Krüger, Peter A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Simultaneous detection of cyanide and heavy metals for environmental analysis by means of µISEs JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 817 EP - 823 ER - TY - JOUR A1 - Turek, M. A1 - Keusgen, M. A1 - Poghossian, Arshak A1 - Mulchandani, A. A1 - Wang, J. A1 - Schöning, Michael Josef T1 - Enzyme-modified electrolyte-insulator-semiconductor sensors JF - Journal of Contemporary Physics. 43 (2008), H. 2 Y1 - 2008 SN - 1934-9378 N1 - Armenian Academy of Sciences SP - 82 EP - 85 ER - TY - JOUR A1 - Thust, Marion A1 - Schöning, Michael Josef A1 - Frohnhoff, S. A1 - Arens-Fischer, R. A1 - Kordos, P. A1 - Lüth, H. T1 - Porous silicon as a substrate material for potentiometric biosensors JF - Measurement Science and Technology Y1 - 1996 U6 - http://dx.doi.org/10.1088/0957-0233/7/1/003 VL - 7 IS - 1 SP - 26 EP - 29 ER - TY - JOUR A1 - Thust, Marion A1 - Mulchandani, Ashok A1 - Wang, Joseph A1 - Arzdorf, Michael A1 - Mulchandani, Priti A1 - Chen, Wilfried A1 - Schöning, Michael Josef T1 - Feldeffekt-Enzymsensor zur Detektion von Pestiziden JF - Technisches Messen. 70 (2003), H. 12 Y1 - 2003 SN - 0171-8096 SP - 561 EP - 564 ER - TY - JOUR A1 - Thust, M. A1 - Schöning, Michael Josef A1 - Schroth, P. A1 - Malkoc, Ü. A1 - Dicker, C. I. A1 - Steffen, A. A1 - Kordos, P. A1 - Lüth, H. T1 - Enzyme immobilisation on planar and porous silicon substrates for biosensor applications JF - Journal of Molecular Catalysis B: Enzymatic. 7 (1999), H. 1-4 Y1 - 1999 SN - 1381-1177 SP - 77 EP - 83 ER - TY - JOUR A1 - Thust, M. A1 - Schöning, Michael Josef A1 - Muchandani, A. A1 - Wang, J. A1 - Arzdorf, M. A1 - Mulchandani, P. A1 - Chen, W. T1 - Feldeffekt-Enzymsensor zur Detektion von Pestiziden JF - Sensoren für zukünftige Hochtechnologien und Neuentwicklungen für die Verfahrenstechnik / 6. Dresdner Sensor-Symposium, 8. - 10. Dezember 2003, Dresden. Jörg Peter Baselt; Gerald Gerlach (Hg.) Y1 - 2003 SN - 3-935712-92-8 SP - 125 EP - 128 PB - w.e.b.-Univ.-Verl. CY - Dresden ER - TY - JOUR A1 - Thust, M. A1 - Schroth, P. A1 - Töpler, A. A1 - Schöning, Michael Josef A1 - Müller-Veggian, Mattea A1 - Kordos, P. A1 - Lüth, H. T1 - Improving the detection limit of a capacitive sensor by means of a diffusion barrier JF - Eurosensors XII : proceedings of the 12th European Conference on Solid-State Transducers and the 9th UK Conference on Sensors and their Applications, Southampton, UK, 13 - 16 September 1998 / ed. by N. M. White ; Vol. 1 Y1 - 1998 SN - 0-7503-0595-9 N1 - Eurosensors ; (12, 1998, Southampton) ; UK Conference on Sensors and Their Applications ; (9, 1998, Southampton) SP - 507 EP - 510 PB - Inst. of Physics Publ. CY - Bristol [u.a.] ER - TY - JOUR A1 - Thust, M. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Naser, S. A1 - Müller-Veggian, Mattea A1 - Kordos, P. A1 - Lüth, H. T1 - Crosssensitivity of a capacitive penicillin sensor combined with a diffusion barrier JF - Proceedings : The Hague, The Netherlands, September 12 - 15, 1999 / [ed. by M. Bartek]. Vol 1. Y1 - 1999 SN - 90-76699-02-X N1 - Eurosensors ; (13, 1999, 's-Gravenhage) ; Eurosensors ; (13 : ; 1999.09.12-15 : ; The Hague) ; European Conference on Solid-State Transducers ; (13 : ; 1999.09.12-15 : ; The Hague) SP - 573 EP - 576 CY - The Hague, The Netherlands ER - TY - JOUR A1 - Thust, M. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Naser, S. A1 - Müller-Veggian, Mattea A1 - Kordos, P. A1 - Lüth, H. T1 - Cross-sensitivity of a capacitive penicillin sensor combined with a diffusion barrier JF - Proceedings : The Hague, The Netherlands, September 12 - 15, 1999 / [ed. by M. Bartek]. - Vol 1. Y1 - 1999 SN - 90-76699-02-X N1 - Eurosensors <13, 1999, 's-Gravenhage> ; Eurosensors <13, 1999, The Hague> ; European Conference on Solid-State Transducers <13, 1999, The Hague> SP - 573 EP - 576 CY - The Hague, The Netherlands ER - TY - CHAP A1 - Takenaga, Shoko A1 - Werner, Frederik A1 - Sawada, Kazuaki A1 - Schöning, Michael Josef T1 - Comparison of label-free ACh image sensors based on CCD and LAPS Y1 - 2012 SN - 978-3-9813484-2-2 U6 - http://dx.doi.org/10.5162/IMCS2012/4.2.6 SP - 356 EP - 359 ER - TY - JOUR A1 - Takenaga, Shoko A1 - Schneider, Benno A1 - Erbay, E. A1 - Biselli, Manfred A1 - Schnitzler, Thomas A1 - Schöning, Michael Josef A1 - Wagner, Torsten T1 - Fabrication of biocompatible lab-on-chip devices for biomedical applications by means of a 3D-printing process JF - Physica status solidi (a) N2 - A new microfluidic assembly method for semiconductor-based biosensors using 3D-printing technologies was proposed for a rapid and cost-efficient design of new sensor systems. The microfluidic unit is designed and printed by a 3D-printer in just a few hours and assembled on a light-addressable potentiometric sensor (LAPS) chip using a photo resin. The cell growth curves obtained from culturing cells within microfluidics-based LAPS systems were compared with cell growth curves in cell culture flasks to examine biocompatibility of the 3D-printed chips. Furthermore, an optimal cell culturing within microfluidics-based LAPS chips was achieved by adjusting the fetal calf serum concentrations of the cell culture medium, an important factor for the cell proliferation. Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201532053 SN - 1862-6319 VL - 212 IS - 6 SP - 1347 EP - 1352 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Schubert, Jürgen A1 - Schöning, Michael Josef T1 - Dünnschichtsensoren für die Schwermetallanalytik JF - GIT : Labor-Fachzeitschrift N2 - Die Detektion von Schadstoffen repräsentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte Dünnschichtsensoren bieten eine kostengünstige Möglichkeit, „online“-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuführen. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgläsern zur Detektion von Schwermetallen in wässrigen Medien vorgestellt. Y1 - 2012 SN - 0016-3538 VL - 56 IS - 4 SP - 285 EP - 287 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Schubert, Jürgen A1 - Schöning, Michael Josef T1 - Dünnschichtsensoren für die Schwermetallanalytik : Mikroelektroden auf Chalkogenidglasbasis JF - GIT Labor-Fachzeitschrift N2 - Die Detektion von Schadstoffen repräsentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte Dünnschichtsensoren bieten eine kostengünstige Möglichkeit, „online“-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuführen. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgläsern zur Detektion von Schwermetallen in wässrigen Medien vorgestellt. Y1 - 2012 IS - 4 SP - 285 EP - 287 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Schaffrath, Sophie A1 - Coppe, Thomas A1 - Rufi, Frederic A1 - Schöning, Michael Josef T1 - Development of an electrolyte-insulator-semiconductor (EIS) based capacitive heavy metal sensor for the detection of Pb2+ und Cd2+ ions JF - Physica status solidi (a) : applications and material science. 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 930 EP - 934 ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Self-aligned nanogaps and nanochannels via conventional photolithography and pattern-size reduction technique JF - Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI Y1 - 2009 SN - 0013-4686 SP - 6010 EP - 6014 ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Kirsanov, Dmitry A1 - Legin, Andrey A1 - Osterrath, Thomas A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Schöning, Michael Josef T1 - Development of a thin-film sensor array for analytical monitoring of heavy metals in aqueous solutions JF - Physica Status Solidi (a) N2 - In industrial processes there is a variety of heavy metals (e.g., copper, zinc, cadmium, and lead) in use for wires, coatings, paints, alloys, batteries, etc. Since the application of these transition metals for industry is inevitable, it is a vital task to develop proper analytical techniques for their monitoring at low activity levels, especially because most of these elements are acutely toxic for biological organisms. The determination of ions in solution by means of a simple and inexpensive sensor array is, therefore, a promising task. In this work, a sensor array with heavy metal-sensitive chalcogenide glass membranes for the simultaneous detection of the four ions Ag⁺, Cu2⁺, Cd2⁺, and Pb2⁺ in solution is realized. The results of the physical characterization by means of microscopy, profilometry, Rutherford backscattering spectroscopy (RBS), and scanning electron microscopy (SEM) as well as the electrochemical characterization by means of potentiometric measurements are presented. Additionally, the possibility to expand the sensor array by polymeric sensor membranes is discussed. Y1 - 2012 SN - 1862-6319 U6 - http://dx.doi.org/10.1002/pssa.201100733 VL - 209 IS - 5 SP - 885 EP - 891 PB - Wiley-VCH CY - Weinheim ER -