TY - JOUR A1 - Pham, Phu Tinh A1 - Vu, Khoi Duc A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - A primal-dual algorithm for shakedown analysis of elastic-plastic bounded linearly kinematic hardening bodies Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 7 ER - TY - CHAP A1 - Tran, Thanh Ngoc A1 - Staat, Manfred ED - Eberhardsteiner, J. T1 - A primal-dual shakedown analysis of 3D structures using the face-based smoothed finite element method T2 - Proceedings European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Y1 - 2012 N1 - 6th European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Vienna, Austria, September 10-14, 2012 ER - TY - CHAP A1 - de Honde, Lukas A1 - Porst, Dariusz A1 - Digel, Ilya ED - Fischerauer, Alice T1 - A randomized, observational thermographic study of the neck region before and after a physiotherapeutic intervention T2 - 2nd YRA MedTech Symposium 2017 : June 8th - 9th / 2017 / Hochschule Ruhr-West Y1 - 2017 SN - 978-3-9814801-9-1 U6 - http://dx.doi.org/10.17185/duepublico/43984 N1 - A young researchers track of the 7th IEEE Workshop & SENSORICA 2017 SP - 122 EP - 123 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, M. A1 - Hormes, M. A1 - Steinseifer, U. A1 - Arora, D. A1 - Coronado, O. A1 - Pasquali, M. T1 - A Review of Computational Fluid Dynamics Analysis of Blood Pumps JF - European Journal of Applied Mathematics. 20 (2009), H. 4 Y1 - 2009 SP - 363 EP - 397 PB - Cambridge Univ. Press CY - Cambridge ER - TY - JOUR A1 - Hillen, Walter A1 - Schiebel, U. A1 - Zaengel, T. T1 - A selenium-based detector for digital slot-radiography JF - Medical Imaging II Y1 - 1988 N1 - Proceedings of SPIE ; 914 SP - 253 ER - TY - CHAP A1 - Schöning, Michael Josef A1 - Abouzar, Maryam H. A1 - Wagner, Torsten A1 - Näther, Niko A1 - Rolka, David A1 - Yoshinobu, Tatsuo A1 - Kloock, Joachim P. A1 - Turek, Monika A1 - Ingebrandt, Sven A1 - Poghossian, Arshak T1 - A semiconductor-based field-effect platform for (bio-)chemical and physical sensors: From capacitive EIS sensors and LAPS over ISFETs to nano-scale devices T2 - MRS Proceedings Y1 - 2006 U6 - http://dx.doi.org/10.1557/PROC-0952-F08-02 N1 - Vol. 952 - Symposium F - Integrated Nanosensors SP - 1 EP - 9 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Buß, G. A1 - Faßbender, F. A1 - Glück, O. A1 - Schmitt, G. A1 - Schultze, J. W. A1 - Lüth, H. T1 - A silicon-based microelectrode array for chemical analysis JF - Sensors and Actuators B. 65 (2000), H. 1-3 Y1 - 2000 SN - 0925-4005 SP - 284 EP - 287 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Buß, G. A1 - Faßbender, F. A1 - Glück, O. A1 - Schmitt, G. A1 - Schultze, J. W. A1 - Lüth, H. T1 - A silicon-based microelectrode array for chemical analysis JF - Proceedings of the Seventh International Meeting on Chemical Sensors : 27 - 30 July, 1998, Beijing, P. R. China / ed. Zhi-Gang Zhou Y1 - 1998 N1 - International Meeting on Chemical Sensors ; (7, 1998, Beijing) ; International Meeting on Chemical Sensors (IMCS) ; (7 : ; 1998.07.27-30 : ; Beijing) SP - 100 EP - 102 PB - Elsevier CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Bäcker, Matthias A1 - Pouyeshman, S. A1 - Schnitzler, Thomas A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Biselli, Manfred A1 - Schöning, Michael Josef T1 - A silicon-based multi-sensor chip for monitoring of fermentation processes JF - Physica status solidi (a) : applications and material science. 208 (2011), H. 6 Y1 - 2011 SN - 1862-6319 SP - 1364 EP - 1369 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Weidenbrück, B. A1 - Thust, M. A1 - Kordos, P. A1 - Lüth, H. T1 - A silicon-based sensor array with capacitive EIS structures JF - Proceedings of the 11th European Conference on Solid-State Transducers / Eurosensors XI, September 21 - 24, 1997, Warsaw, Poland. [Organised by] Warsaw University of Technology. Vol 2. Y1 - 1997 SN - 83-908335-0-6 N1 - Eurosensors ; (11, 1997, Warszawa) ; Eurosensors - European Conference on Solid-State Transducers ; (11 : ; 1997.09.21-24 : ; Warsaw) SP - 871 EP - 874 PB - Sensor Lab Sp. CY - Warsaw ER - TY - CHAP A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - A simplification for shakedown analysis of hardening structures T2 - Conference proceedings of the YIC GACM 2015 : 3rd ECCOMAS Young Investigators Conference and 6th GACM Colloquium on Computational Mechanics , Aachen , Germany, 20.07.2015 - 23.07.2015 / ed.: Stefanie Elgeti ; Jaan-Willem Simon Y1 - 2015 SP - 1 EP - 4 PB - RWTH Aachen University CY - Aachen ER - TY - JOUR A1 - Hillen, Walter A1 - Alper Selver, M. A1 - Fischer, Felix A1 - Kuntalp, Mehmet T1 - A software tool for interactive generation, representation, and systematical storage of transfer functions for 3D medical images / Alper Selver, M. ; Fischer, Felix ; Kuntalp, Mehmet ; Hillen, Walter JF - Computer Methods and Programs in Biomedicine. 86 (2007), H. 3 Y1 - 2007 SN - 0169-2607 SP - 270 EP - 280 PB - - ER - TY - JOUR A1 - Reißel, Martin A1 - Bitsch, G. A1 - Stamm, H. T1 - A Stern Door Slam Fatigue Calculation / Bitsch, G. ; Reißel, M. ; Stamm, H. JF - Proceedings of the 18. CAD-FEM Users Meeting Y1 - 2000 ER - TY - CHAP A1 - Siebigteroth, Ines A1 - Kraft, Bodo A1 - Schmidts, Oliver A1 - Zündorf, Albert T1 - A Study on Improving Corpus Creation by Pair Annotation T2 - Proceedings of the Poster Session of the 2nd Conference on Language, Data and Knowledge (LDK-PS 2019) Y1 - 2019 SN - 1613-0073 SP - 40 EP - 44 ER - TY - JOUR A1 - Bergmann, Sandra A1 - Demuth, Bastian A1 - Sander, Volker T1 - A Web Framework for Workflow Submission and Monitoring via UNICORE 6 based on Distributable Scientific Workflow Templates JF - UNICORE Summit 2011 : proceedings, 7-8 July 2011, Torun, Poland / Mathilde Romberg ... (Eds.) Y1 - 2011 SN - 9783893367504 N1 - UNICORE Summit ; (2011 ; 2011.07.07-08 ; Torun) ; Schriften des Forschungszentrums Jülich IAS Series 9 SP - 45 EP - 50 PB - Forschungszentrum Jülich CY - Jülich ER - TY - JOUR A1 - Simonis, A. A1 - Krings, T. A1 - Lüth, H. A1 - Wang, J. A1 - Schöning, Michael Josef T1 - A „hybrid“ thin-film pH sensor with integrated thick-film reference JF - Sensors. 1 (2001), H. 6 Y1 - 2001 SN - 1424-8220 SP - 183 EP - 192 ER - TY - JOUR A1 - Pawelke, Siegfried A1 - Schmitt, W. A1 - Meissen, Th. T1 - Aachen 3D finger. 3D digitizer for application in dentistry / Schmitt, W. ; Pawelke, S. ; Meissen, Th. JF - Biomedizinische Technik. 35 (1990), H. 4 Y1 - 1990 SN - 0013-5585 SP - 69 EP - 71 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kloock, Joachim P. T1 - About 20 years of silicon-based thin-film sensors with chalcogenide glass materials for heavy metal analysis: Technological aspects of fabrication and miniaturization JF - Electroanalysis. 19 (2007), H. 19-20 Y1 - 2007 SN - 1040-0397 SP - 2029 EP - 2038 ER - TY - CHAP A1 - Gerhards, Michael A1 - Sander, Volker A1 - Belloum, Adam ED - Zimmermann, Wolf ED - Lee, Yong Woo ED - Demchenko, Yuri T1 - About the flexible Migration of Workflow Tasks to Clouds : Combining on- and off-premise Executions of Applications T2 - CLOUD COMPUTING 2012 : The Third International Conference on Cloud Computing, GRIDs, and Virtualization ; July 22-27, 2012 - Nice, France N2 - An increasing number of applications target their executions on specific hardware like general purpose Graphics Processing Units. Some Cloud Computing providers offer this specific hardware so that organizations can rent such resources. However, outsourcing the whole application to the Cloud causes avoidable costs if only some parts of the application benefit from the specific expensive hardware. A partial execution of applications in the Cloud is a tradeoff between costs and efficiency. This paper addresses the demand for a consistent framework that allows for a mixture of on- and off-premise calculations by migrating only specific parts to a Cloud. It uses the concept of workflows to present how individual workflow tasks can be migrated to the Cloud whereas the remaining tasks are executed on-premise. KW - Workflow Orchestration KW - Workflow KW - Grid Computing KW - Cloud Service Broker KW - Cloud Computing Y1 - 2012 SN - 978-1-61208-216-5 SP - 82 EP - 87 PB - IARIA Journals ER - TY - JOUR A1 - Berretz, Frank A1 - Skorupa, Sasche A1 - Sander, Volker A1 - Belloum, Adam A1 - Bubak, Marian T1 - Actor-Driven Workflow Execution in Distributed Environments JF - Euro-Par 2010 Parallel Processing Workshops : HeteroPAR, HPCC, HiBB, CoreGrid, UCHPC, HPCF, PROPER, CCPI, VHPC ; Ischia, Italy, August 31 - September 3, 2010 ; revised selected papers / Mario R. Guarracino ... (eds.) Y1 - 2011 SN - 978-3-642-21877-4 N1 - Lecture Notes in Computer Science ; 6586 SP - 287 EP - 294 PB - Springer CY - Berlin ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Karamanidis, Kiros A1 - Albracht, Kirsten T1 - Adaptational responses of the human Achilles tendon by modulation of the applied cyclic strain magnitude JF - Journal of Experimental Biology Y1 - 2007 U6 - http://dx.doi.org/10.1242/jeb.003814 SN - 0022-0949 VL - 210 IS - 15 SP - 2743 EP - 2753 ER - TY - JOUR A1 - Ketelhut, Maike A1 - Brügge, G. M. A1 - Göll, Fabian A1 - Braunstein, Bjoern A1 - Albracht, Kirsten A1 - Abel, Dirk T1 - Adaptive iterative learning control of an industrial robot during neuromuscular training JF - IFAC PapersOnLine N2 - To prevent the reduction of muscle mass and loss of strength coming along with the human aging process, regular training with e.g. a leg press is suitable. However, the risk of training-induced injuries requires the continuous monitoring and controlling of the forces applied to the musculoskeletal system as well as the velocity along the motion trajectory and the range of motion. In this paper, an adaptive norm-optimal iterative learning control algorithm to minimize the knee joint loadings during the leg extension training with an industrial robot is proposed. The response of the algorithm is tested in simulation for patients with varus, normal and valgus alignment of the knee and compared to the results of a higher-order iterative learning control algorithm, a robust iterative learning control and a recently proposed conventional norm-optimal iterative learning control algorithm. Although significant improvements in performance are made compared to the conventional norm-optimal iterative learning control algorithm with a small learning factor, for the developed approach as well as the robust iterative learning control algorithm small steady state errors occur. KW - Iterative learning control KW - Robotic rehabilitation KW - Adaptive control Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.ifacol.2020.12.741 SN - 2405-8963 VL - 53 IS - 2 SP - 16468 EP - 16475 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Atlas, Glen A1 - Brealey, David A1 - Dhar, Sunil A1 - Dikta, Gerhard A1 - Singer, Meryvn T1 - Additional hemodynamic measurements with an esophageal Doppler monitor: a preliminary report of compliance, force, kinetic energy, and afterload in the clinical setting JF - Journal of clinical monitoring and computing N2 - The esophageal Doppler monitor (EDM) is a minimally-invasive hemodynamic device which evaluates both cardiac output (CO), and fluid status, by estimating stroke volume (SV) and calculating heart rate (HR). The measurement of these parameters is based upon a continuous and accurate approximation of distal thoracic aortic blood flow. Furthermore, the peak velocity (PV) and mean acceleration (MA), of aortic blood flow at this anatomic location, are also determined by the EDM. The purpose of this preliminary report is to examine additional clinical hemodynamic calculations of: compliance (C), kinetic energy (KE), force (F), and afterload (TSVRi). These data were derived using both velocity-based measurements, provided by the EDM, as well as other contemporaneous physiologic parameters. Data were obtained from anesthetized patients undergoing surgery or who were in a critical care unit. A graphical inspection of these measurements is presented and discussed with respect to each patient’s clinical situation. When normalized to each of their initial values, F and KE both consistently demonstrated more discriminative power than either PV or MA. The EDM offers additional applications for hemodynamic monitoring. Further research regarding the accuracy, utility, and limitations of these parameters is therefore indicated. KW - Acceleration KW - Velocity KW - Kinetic energy KW - Force KW - Compliance KW - Afterload KW - Contractility KW - Volume status KW - Esophageal Doppler monitor Y1 - 2012 SN - 1573-2614 U6 - http://dx.doi.org/10.1007/s10877-012-9386-5 IS - 26 SP - 473 EP - 482 PB - Springer Nature CY - London ER - TY - JOUR A1 - Kaul, D. K. A1 - Koshkaryev, A. A1 - Artmann, Gerhard A1 - Barshtein, G. A1 - Yedgar, S. T1 - Additive effect of red blood cell rigidity and adherence to endothelial cells in inducing vascular resistance JF - American Journal of Physiology : Heart and Circulation Physiology . 295 (2008), H. 4 Y1 - 2008 SN - 1522-1539 VL - 295 IS - 4 SP - H1788 EP - H1793 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Akhisaroglu, M. A1 - Sercan, Z. A1 - Kayatekin, B. M. T1 - Adhesion of Erythrocytes to Endothelial Cells After Acute Exercise: Differences in Red Blood Cells from Juvenile and Adult Rats. Temiz Artmann, A.; Akhisaroglu, M.; Sercan, Z.; Kayatekin, BM.; Yorukoglu, K.; Kirkali, G. JF - Physiological Research (2005) Y1 - 2005 SN - 0862-8408 N1 - pre-press article ER - TY - JOUR A1 - Ketelhut, Maike A1 - Kolditz, Melanie A1 - Göll, Fabian A1 - Braunstein, Bjoern A1 - Albracht, Kirsten A1 - Abel, Dirk T1 - Admittance control of an industrial robot during resistance training JF - IFAC-PapersOnLine N2 - Neuromuscular strength training of the leg extensor muscles plays an important role in the rehabilitation and prevention of age and wealth related diseases. In this paper, we focus on the design and implementation of a Cartesian admittance control scheme for isotonic training, i.e. leg extension and flexion against a predefined weight. For preliminary testing and validation of the designed algorithm an experimental research and development platform consisting of an industrial robot and a force plate mounted at its end-effector has been used. Linear, diagonal and arbitrary two-dimensional motion trajectories with different weights for the leg extension and flexion part are applied. The proposed algorithm is easily adaptable to trajectories consisting of arbitrary six-dimensional poses and allows the implementation of individualized trajectories. KW - Assistive technology KW - Rehabilitation engineering KW - Human-Computer interaction KW - Automatic control Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.ifacol.2019.12.102 SN - 2405-8963 N1 - 14th IFAC Symposium on Analysis, Design, and Evaluation of Human Machine Systems HMS 2019 Tallinn, Estonia, 16–91 September 2019 VL - 52 IS - 19 SP - 223 EP - 228 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Akimbekov, N.Sh. A1 - Digel, Ilya A1 - O’Heras, C. A1 - Tastambek, K.T. A1 - Savitskaya, I.S. A1 - Ualyeva, P.S. A1 - Mansurov, Z.A. A1 - Zhubanova, A.A. T1 - Adsorption of bacterial lipopol ysaccharides on carbonized ri ce husks obtained in the batch experiments JF - KazNU Bulletin. Biology series Y1 - 2015 SN - 1563-0218 VL - 60 IS - No 1/2 SP - 144 EP - 148 ER - TY - JOUR A1 - Akimbekov, N.Sh. A1 - Digel, Ilya A1 - O´Heras, C. A1 - Tastambek, K.T. A1 - Savitskaya, I.S. A1 - Ualyeva, P.S. A1 - Mansurov, Z.A. A1 - Zhubanova, A.A. T1 - Adsorption of bacterial lipopolysaccharides on carbonized rice husks obtained in the batch experiments JF - Experimental Biology N2 - The scope of this study is the measurement of endotoxin adsorption rate for carbonized rice husk. It showed good adsorption properties for LPS. During the batch experiments, several techniques were used and optimized for improving the material’s adsorption behavior. Also, with the results obtained it was possible to differentiate the materials according to their adsorption capacity and kinetic characteristics. KW - surface modification KW - adsorption KW - carbonized rice husk KW - lipopolysaccharide Y1 - 2014 SN - 1563-0218 N1 - Original in russischer Sprache VL - 60 IS - 1/2 SP - 144 EP - 148 PB - Al-Farabi Kazakh National University CY - Almaty ER - TY - JOUR A1 - Kozhalakova, A. A. A1 - Zhubanova, Azhar A. A1 - Mansurov, Z. A. A1 - Digel, Ilya A1 - Tazhibayeva, S. M. A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül T1 - Adsorption of bacterial lipopolysaccharides on carbonized rice shell JF - Science of Central Asia (2010) Y1 - 2010 SP - 50 EP - 54 ER - TY - BOOK A1 - Sander, Volker A1 - Roy, Alain T1 - Advance Reservation API / Roy, Alain ; Sander, Volker Y1 - 2002 N1 - GFD-E.5 Scheduling Working Group Category: Experimental PB - Global Grid Forum ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Colautti, P. A1 - Conte, V. A1 - De Nardo, L. T1 - Advanced TEPC (Tissue-equivalent proportional counters) for radiation monitoring JF - Annual report / Istituto Nazionale di Fisica Nucleare, LNL, Laboratori Nazionali di Legnaro. 1998 (1999) Y1 - 1999 SP - 106 ER - TY - JOUR A1 - Mandekar, Swati A1 - Holland, Abigail A1 - Thielen, Moritz A1 - Behbahani, Mehdi A1 - Melnykowycz, Mark T1 - Advancing towards Ubiquitous EEG, Correlation of In-Ear EEG with Forehead EEG JF - Sensors N2 - Wearable EEG has gained popularity in recent years driven by promising uses outside of clinics and research. The ubiquitous application of continuous EEG requires unobtrusive form-factors that are easily acceptable by the end-users. In this progression, wearable EEG systems have been moving from full scalp to forehead and recently to the ear. The aim of this study is to demonstrate that emerging ear-EEG provides similar impedance and signal properties as established forehead EEG. EEG data using eyes-open and closed alpha paradigm were acquired from ten healthy subjects using generic earpieces fitted with three custom-made electrodes and a forehead electrode (at Fpx) after impedance analysis. Inter-subject variability in in-ear electrode impedance ranged from 20 kΩ to 25 kΩ at 10 Hz. Signal quality was comparable with an SNR of 6 for in-ear and 8 for forehead electrodes. Alpha attenuation was significant during the eyes-open condition in all in-ear electrodes, and it followed the structure of power spectral density plots of forehead electrodes, with the Pearson correlation coefficient of 0.92 between in-ear locations ELE (Left Ear Superior) and ERE (Right Ear Superior) and forehead locations, Fp1 and Fp2, respectively. The results indicate that in-ear EEG is an unobtrusive alternative in terms of impedance, signal properties and information content to established forehead EEG. KW - in-ear EEG KW - correlation KW - forehead EEG KW - impedance spectroscopy KW - biopotential electrodes Y1 - 2022 U6 - http://dx.doi.org/10.3390/s22041568 SN - 1424-8220 VL - 22 IS - 4 SP - 1 EP - 19 PB - MDPI CY - Basel ER - TY - JOUR A1 - Müller, Wolfram A1 - Jung, Alexander A1 - Ahammer, Helmut T1 - Advantages and problems of nonlinear methods applied to analyze physiological time signals: human balance control as an example JF - Scientific Reports Y1 - 2017 SN - 2045-2322 U6 - http://dx.doi.org/10.1038/s41598-017-02665-5 VL - 7 IS - Article number 2464 SP - 1 EP - 11 PB - Springer Nature CY - Cham ER - TY - JOUR A1 - Engelmann, Ulrich M. A1 - Buhl, Eva Miriam A1 - Baumann, Martin A1 - Schmitz-Rode, Thomas A1 - Slabu, Ioana T1 - Agglomeration of magnetic nanoparticles and its effects on magnetic hyperthermia JF - Current Directions in Biomedical Engineering Y1 - 2017 U6 - http://dx.doi.org/10.1515/cdbme-2017-0096 SN - 2364-5504 VL - 3 IS - 2 SP - 457 EP - 460 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Morat, Mareike A1 - Faude, Oliver A1 - Hanssen, Henner A1 - Ludyga, Sebastian A1 - Zacher, Jonas A1 - Eibl, Angi A1 - Albracht, Kirsten A1 - Donath, Lars T1 - Agility Training to Integratively Promote Neuromuscular, Cognitive, Cardiovascular and Psychosocial Function in Healthy Older Adults: A Study Protocol of a One-Year Randomized-Controlled Trial JF - International Journal of Environmental Research and Public Health N2 - Exercise training effectively mitigates aging-induced health and fitness impairments. Traditional training recommendations for the elderly focus separately on relevant physiological fitness domains, such as balance, flexibility, strength and endurance. Thus, a more holistic and functional training framework is needed. The proposed agility training concept integratively tackles spatial orientation, stop and go, balance and strength. The presented protocol aims at introducing a two-armed, one-year randomized controlled trial, evaluating the effects of this concept on neuromuscular, cardiovascular, cognitive and psychosocial health outcomes in healthy older adults. Eighty-five participants were enrolled in this ongoing trial. Seventy-nine participants completed baseline testing and were block-randomized to the agility training group or the inactive control group. All participants undergo pre- and post-testing with interim assessment after six months. The intervention group currently receives supervised, group-based agility training twice a week over one year, with progressively demanding perceptual, cognitive and physical exercises. Knee extension strength, reactive balance, dual task gait speed and the Agility Challenge for the Elderly (ACE) serve as primary endpoints and neuromuscular, cognitive, cardiovascular, and psychosocial meassures serve as surrogate secondary outcomes. Our protocol promotes a comprehensive exercise training concept for older adults, that might facilitate stakeholders in health and exercise to stimulate relevant health outcomes without relying on excessively time-consuming physical activity recommendations. KW - agility KW - prevention KW - healthy aging KW - community dwelling KW - psychosocial Y1 - 2020 U6 - http://dx.doi.org/10.3390/ijerph17061853 SN - 1660-4601 VL - 17 IS - 6 SP - 1 EP - 14 PB - MDPI CY - Basel ER - TY - JOUR A1 - Bohrn, U. A1 - Stütz, E. A1 - Fuchs, K. A1 - Fleischer, M. A1 - Schöning, Michael Josef A1 - Wagner, P. T1 - Air Quality Monitoring using a Whole-Cell based Sensor System JF - Procedia Engineering. 25 (2011) Y1 - 2011 SN - 1877-7058 N1 - EurosensorsXXV ; Proc. Eurosensors XXV, September 4-7, 2011, Athens, Greece SP - 1421 EP - 1424 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Mikielewicz, Marek A1 - Kotliar, Konstantin A1 - Barraquer, Rafael I. A1 - Michael, Ralph T1 - Air-pulse corneal applanation signal curve parameters for the characterisation of keratoconus JF - British Journal of Ophthalmology (eBJO) Y1 - 2011 SN - 1468-2079 VL - 95 IS - 6 SP - 793 EP - 798 PB - BMJ Publ. Group CY - London ER - TY - JOUR A1 - Warerkar, Shashikant A1 - Schmitz, Stefan A1 - Göttsche, Joachim A1 - Hoffschmidt, Bernhard A1 - Reißel, Martin A1 - Tamme, Rainer T1 - Air-Sand Heat Exchanger for High-Temperature Storage JF - Journal of Solar Energy Engineering. 133 (2011), H. 2 Y1 - 2011 SN - 0199-6231 N1 - 7 pages SP - 021010 PB - ASME CY - New York ER - TY - CHAP A1 - Kohl, Philipp A1 - Freyer, Nils A1 - Krämer, Yoka A1 - Werth, Henri A1 - Wolf, Steffen A1 - Kraft, Bodo A1 - Meinecke, Matthias A1 - Zündorf, Albert ED - Conte, Donatello ED - Fred, Ana ED - Gusikhin, Oleg ED - Sansone, Carlo T1 - ALE: a simulation-based active learning evaluation framework for the parameter-driven comparison of query strategies for NLP T2 - Deep Learning Theory and Applications. DeLTA 2023. Communications in Computer and Information Science N2 - Supervised machine learning and deep learning require a large amount of labeled data, which data scientists obtain in a manual, and time-consuming annotation process. To mitigate this challenge, Active Learning (AL) proposes promising data points to annotators they annotate next instead of a subsequent or random sample. This method is supposed to save annotation effort while maintaining model performance. However, practitioners face many AL strategies for different tasks and need an empirical basis to choose between them. Surveys categorize AL strategies into taxonomies without performance indications. Presentations of novel AL strategies compare the performance to a small subset of strategies. Our contribution addresses the empirical basis by introducing a reproducible active learning evaluation (ALE) framework for the comparative evaluation of AL strategies in NLP. The framework allows the implementation of AL strategies with low effort and a fair data-driven comparison through defining and tracking experiment parameters (e.g., initial dataset size, number of data points per query step, and the budget). ALE helps practitioners to make more informed decisions, and researchers can focus on developing new, effective AL strategies and deriving best practices for specific use cases. With best practices, practitioners can lower their annotation costs. We present a case study to illustrate how to use the framework. KW - Active learning KW - Query learning KW - Natural language processing KW - Deep learning KW - Reproducible research Y1 - 2023 SN - 978-3-031-39058-6 (Print) SN - 978-3-031-39059-3 (Online) U6 - http://dx.doi.org/978-3-031-39059-3 N1 - 4th International Conference, DeLTA 2023, Rome, Italy, July 13–14, 2023. SP - 235 EP - 253 PB - Springer CY - Cham ER - TY - JOUR A1 - Kraft, Bodo A1 - Heer, Thomas A1 - Retkowitz, Daniel T1 - Algorithm and Tool for Ontology Integration Based on Graph Rewriting / Heer, Thomas ; Retkowitz, Daniel ; Kraft, Bodo JF - Applications of Graph Transformations with Industrial Relevance / Third International Symposium, AGTIVE 2007, Kassel, Germany, October 10-12, 2007, Revised Selected and Invited Papers Y1 - 2008 SN - 978-3-540-89019-5 N1 - Lecture Notes in Computer Science ; 5088 SP - 577 EP - 582 ER - TY - JOUR A1 - Hillen, Walter A1 - Barry, J. C. A1 - Pongs, U. M. T1 - Algorithm for Purkinje Image I and IV and Limbus Centre Location. Barry, J. C.; Pongs, U. M.; Hillen, W. JF - Computers in Biology and Medicine. 27 (1997), H. 6 Y1 - 1997 SN - 0010-4825 SP - 515 EP - 531 ER - TY - JOUR A1 - Grotendorst, Johannes T1 - Algorithms of mixed symbolic-numeric type for rational approximation JF - Artificial intelligence, expert systems and symbolic computing : selected and revised papers from the IMACS 13th World Congress [on Computation and Applied Mathematics], Dublin, Ireland, July 1991 / ed. by Elias N. Houstis ... Y1 - 1992 SN - 0-444-89703-8 N1 - zgl. Technical Report KFA-ZAM-IB-9205 ; World Congress on Computation and Applied Mathematics <13, 1991, Dublin> ; International Association for Mathematics and Computers in Simulation SP - 145 EP - 154 PB - North-Holland CY - Amsterdam ER - TY - JOUR A1 - Gaigall, Daniel ED - AitSahlia, Farid T1 - Allocating and forecasting changes in risk JF - Journal of risk N2 - We consider time-dependent portfolios and discuss the allocation of changes in the risk of a portfolio to changes in the portfolio’s components. For this purpose we adopt established allocation principles. We also use our approach to obtain forecasts for changes in the risk of the portfolio’s components. To put the approach into practice we present an implementation based on the output of a simulation. Allocation is illustrated with an example portfolio in the context of Solvency II. The quality of the forecasts is investigated with an empirical study. KW - portfolio risk KW - allocation KW - forecast KW - covariance principle KW - conditional expectation principle Y1 - 2023 U6 - http://dx.doi.org/10.21314/JOR.2022.048 SN - 1755-2842 SN - 1465-1211 VL - 25 IS - 3 SP - 1 EP - 24 PB - Infopro Digital Risk CY - London ER - TY - JOUR A1 - Stäudle, Benjamin A1 - Seynnes, Olivier A1 - Laps, Guido A1 - Brüggemann, Gert-Peter A1 - Albracht, Kirsten T1 - Altered gastrocnemius contractile behavior in former achilles tendon rupture patients during walking JF - Frontiers in Physiology N2 - Achilles tendon rupture (ATR) remains associated with functional limitations years after injury. Architectural remodeling of the gastrocnemius medialis (GM) muscle is typically observed in the affected leg and may compensate force deficits caused by a longer tendon. Yet patients seem to retain functional limitations during—low-force—walking gait. To explore the potential limits imposed by the remodeled GM muscle-tendon unit (MTU) on walking gait, we examined the contractile behavior of muscle fascicles during the stance phase. In a cross-sectional design, we studied nine former patients (males; age: 45 ± 9 years; height: 180 ± 7 cm; weight: 83 ± 6 kg) with a history of complete unilateral ATR, approximately 4 years post-surgery. Using ultrasonography, GM tendon morphology, muscle architecture at rest, and fascicular behavior were assessed during walking at 1.5 m⋅s–1 on a treadmill. Walking patterns were recorded with a motion capture system. The unaffected leg served as control. Lower limbs kinematics were largely similar between legs during walking. Typical features of ATR-related MTU remodeling were observed during the stance sub-phases corresponding to series elastic element (SEE) lengthening (energy storage) and SEE shortening (energy release), with shorter GM fascicles (36 and 36%, respectively) and greater pennation angles (8° and 12°, respectively). However, relative to the optimal fascicle length for force production, fascicles operated at comparable length in both legs. Similarly, when expressed relative to optimal fascicle length, fascicle contraction velocity was not different between sides, except at the time-point of peak series elastic element (SEE) length, where it was 39 ± 49% lower in the affected leg. Concomitantly, fascicles rotation during contraction was greater in the affected leg during the whole stance-phase, and architectural gear ratios (AGR) was larger during SEE lengthening. Under the present testing conditions, former ATR patients had recovered a relatively symmetrical walking gait pattern. Differences in seen AGR seem to accommodate the profound changes in MTU architecture, limiting the required fascicle shortening velocity. Overall, the contractile behavior of the GM fascicles does not restrict length- or velocity-dependent force potentials during this locomotor task. KW - tendon rupture KW - muscle fascicle behavior KW - walking gait KW - force generation KW - ultrasound imaging Y1 - 2022 U6 - http://dx.doi.org/10.3389/fphys.2022.792576 SN - 1664-042X VL - 13 PB - Frontiers Research Foundation CY - Lausanne ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Hauser, Christine A1 - Ortner, Marion A1 - Muggenthaler, Claudia A1 - Diehl-Schmid, Janine A1 - Angermann, Susanne A1 - Hapfelmeier, Alexander A1 - Schmaderer, Christoph A1 - Grimmer, Timo T1 - Altered neurovascular coupling as measured by optical imaging: a biomarker for Alzheimer’s disease JF - Scientific Reports Y1 - 2017 U6 - http://dx.doi.org/10.1038/s41598-017-13349-5 SN - 2045-2322 N1 - Article 12906 VL - 7 IS - 1 SP - 1 EP - 11 PB - Springer Nature CY - Cham ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Ortner, Marion A1 - Conradi, Anna A1 - Hacker, Patricia A1 - Hauser, Christine A1 - Günthner, Roman A1 - Moser, Michaela A1 - Muggenthaler, Claudia A1 - Diehl-Schmid, Janine A1 - Priller, Josef A1 - Schmaderer, Christoph A1 - Grimmer, Timo T1 - Altered retinal cerebral vessel oscillation frequencies in Alzheimer's disease compatible with impaired amyloid clearance JF - Neurobiology of Aging N2 - Retinal vessels are similar to cerebral vessels in their structure and function. Moderately low oscillation frequencies of around 0.1 Hz have been reported as the driving force for paravascular drainage in gray matter in mice and are known as the frequencies of lymphatic vessels in humans. We aimed to elucidate whether retinal vessel oscillations are altered in Alzheimer's disease (AD) at the stage of dementia or mild cognitive impairment (MCI). Seventeen patients with mild-to-moderate dementia due to AD (ADD); 23 patients with MCI due to AD, and 18 cognitively healthy controls (HC) were examined using Dynamic Retinal Vessel Analyzer. Oscillatory temporal changes of retinal vessel diameters were evaluated using mathematical signal analysis. Especially at moderately low frequencies around 0.1 Hz, arterial oscillations in ADD and MCI significantly prevailed over HC oscillations and correlated with disease severity. The pronounced retinal arterial vasomotion at moderately low frequencies in the ADD and MCI groups would be compatible with the view of a compensatory upregulation of paravascular drainage in AD and strengthen the amyloid clearance hypothesis. KW - Alzheimer's disease KW - Retinal vessel analysis KW - Vasomotions KW - Pulsations KW - Mild cognitive impairment Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.neurobiolaging.2022.08.012 SN - 0197-4580 VL - 120 SP - 117 EP - 127 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Yoshinobu, T. A1 - Ecken, H. A1 - Poghossian, Arshak A1 - Lüth, H. A1 - Iwasaki, H. A1 - Schöning, Michael Josef T1 - Alternative sensor materials for light-addressable potentiometric sensors JF - Sensors and Actuators B. 76 (2001), H. 1-3 Y1 - 2001 SN - 0925-4005 SP - 388 EP - 392 ER - TY - CHAP A1 - Moritz, Werner A1 - Yoshinobu, Tatsuo A1 - Finger, Friedhelm A1 - Krause, Steffi A1 - Schöning, Michael Josef T1 - Amorphous silicon as semiconductor material for high resolution LAPS T2 - Eurosensors XVII : the 17th European Conference on Solid-State Transducers ; University of Minho, Guimarães, Portugal, September 21 - 24, 2003 Y1 - 2003 SP - 48 EP - 49 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Wang, J. A1 - Jacobs, M. A1 - Knobbe, D.-T. A1 - Muck, A. T1 - Amperometric PDMS-glass capillary electrophoresis-based biosensor microchip for catechol and dopamine detection JF - Technical digest of the 10th International Meeting on Chemical Sensors, July 11 - 14, 2004, Tsukuba, Japan / Japan Association of Chemical Sensors Y1 - 2004 N1 - Chemical sensors ; 20.2004 Suppl. B. IMCS ; (10, 2004, Tsukuba) ; International Meeting on Chemical Sensors ; (10 : ; 2004.07.11-14 : ; Tsukuba) SP - 566 EP - 567 PB - Japan Association of Chemical Sensors CY - Fukuoka ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Jacobs, M. A1 - Muck, A. A1 - Knobbe, D.-T. A1 - Wang, J. A1 - Chatrathi, M. A1 - Spillmann, S. T1 - Amperometric PDMS/glass capillary electrophoresis-based biosensor microchip for catechol and dopamin detection JF - Sensors and Actuators B. 108 (2005), H. 1-2 Y1 - 2005 SN - 0925-4005 N1 - Proceedings of the Tenth International Meeting on Chemical Sensors — IMCS - 10 2004 SP - 688 EP - 694 ER -