TY - JOUR A1 - Martin, S. A. A1 - Berg, G. P. A. A1 - Hacker, U. A1 - Hardt, Arno A1 - Köhler, M. A1 - Meißburger, J. A1 - Osterfeld, F. A1 - Prasuhn, D. A1 - Riepe, G. A1 - Rogge, M. A1 - Schult, O. W. B. A1 - Speth, J. A1 - Turek, P. A1 - Gaul, G. A1 - Hagedoorn, H. A1 - Heide, J. A. van der A1 - Hinterberger, F. A1 - Huber, M. A1 - Jahn, R. A1 - Mayer-Kuckuk, T. A1 - Poth, H. A1 - Paetz gen. Schieck, H. T1 - COSY - a cooler synchrotron and storage ring JF - IEEE transactions on nuclear science. Vol. 32, iss. 5 Y1 - 1985 SN - 1558-1578 (E-Journal); 0018-9499 (Print) SP - 2694 EP - 2696 ER - TY - JOUR A1 - Hardt, Arno A1 - Martin, S. A1 - Meißburger, J. A1 - Retz, R. A1 - Wimmer, J. T1 - The cryopump system of the QQDDQ magnet spectrometer BIG KARL JF - Vacuum N2 - Cryopumps without liquid nitrogen shielding are used to provide a vacuum of 10−6 torr in the spectrometer. The vacuum system is subdivided in three sections that can be separated by valves. The first section (scattering chamber) has a volume of 60 l, two rotation transmissions with 35 cm dia and a sliding seal that allows a rotation of 160° without deteriorating the vacuum. The second section includes the vacuum chambers inside the magnets with 6 × 80 cm cross-section and a length of 1200 cm. The third section (detector box) has a volume of 4300 l and contains a moveable detector system. The gas inside the detector with a pressure of 760 torr is separated from the vacuum by a 15 μm mylar foil with an area of 300 cm2. The detector box can be valved off by a valve with the dimension of 10 × 100 cm. The layout of system is given. The instrumentation and the interlock system are described. First experiences with this system are presented. Y1 - 1978 U6 - http://dx.doi.org/10.1016/S0042-207X(78)80026-8 SN - 1879-2715 (E-Journal); 0042-207X (Print) VL - 28 IS - 10-11 SP - 483 PB - Elsevier CY - Amsterdam ER -