TY - JOUR A1 - Staat, Manfred A1 - Ballmann, J. T1 - Computation of impacts on elastic solids by methods of bicharacteristics JF - Computational Mechanics '88 : theory and applications ; proceedings of the International Conference on Computational Engineering Science April 10-14, 1988, Atlanta, GA, USA ; vol. 2 N2 - Shock waves, explosions, impacts or cavitation bubble collapses may generate stress waves in solids causing cracks or unexpected dammage due to focussing, physical nonlinearity or interaction with existing cracks. There is a growing interest in wave propagation, which poses many novel problems to experimentalists and theorists. KW - Bicharakteristikenverfahren KW - Elastizität KW - elastic solids KW - bicharacteristics Y1 - 1988 SP - 1719 EP - 1722 ER - TY - CHAP A1 - Staat, Manfred A1 - Szelinski, E. A1 - Heitzer, Michael T1 - Kollapsanalyse von längsfehlerbehafteten Rohren und Behältern T1 - Collapse analysis of longitudinally flawed pipes and vessels N2 - Es werden verbesserte Kollapsanalysen von dickwandigen, mit axialen Oberflächenfehlern behafteten Rohren und Behältern vorgeschlagen. KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohr KW - Rohrbruch KW - Fehlerstellen KW - pipes KW - vessels KW - load limit KW - burst tests KW - burst pressure KW - flaw Y1 - 2001 ER - TY - CHAP A1 - Staat, Manfred A1 - Tran, Thanh Ngoc A1 - Pham, Phu Tinh T1 - Limit and shakedown reliability analysis by nonlinear programming N2 - 7th International Conference on Reliability of Materials and Structures (RELMAS 2008). June 17 - 20, 2008 ; Saint Petersburg, Russia. pp 354-358. Reprint with corrections in red Introduction Analysis of advanced structures working under extreme heavy loading such as nuclear power plants and piping system should take into account the randomness of loading, geometrical and material parameters. The existing reliability are restricted mostly to the elastic working regime, e.g. allowable local stresses. Development of the limit and shakedown reliability-based analysis and design methods, exploiting potential of the shakedown working regime, is highly needed. In this paper the application of a new algorithm of probabilistic limit and shakedown analysis for shell structures is presented, in which the loading and strength of the material as well as the thickness of the shell are considered as random variables. The reliability analysis problems may be efficiently solved by using a system combining the available FE codes, a deterministic limit and shakedown analysis, and the First and Second Order Reliability Methods (FORM/SORM). Non-linear sensitivity analyses are obtained directly from the solution of the deterministic problem without extra computational costs. KW - Finite-Elemente-Methode KW - Limit analysis KW - Shakedown analysis Y1 - 2008 ER - TY - CHAP A1 - Tran, Thanh Ngoc A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - Reliability analysis of shells based on direct plasticity methods N2 - Abstracts der CD-Rom Proceedings of the 8th World Congress on Computational Mechanics (WCCM8) and 5th Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2008) 30.06. - 04.07.2008 Venedig, Italien. 2 Seiten Zusammenfassung der Autoren mit graph. Darst. und Literaturverzeichnis N2 - Abstracts of the Proceedings of the 8th World Congress on Computational Mechanics (WCCM8) and 5th Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2008) June 30th - July, 4th 2008, Venice, Italy. 2 pages with abstracts of the authors, Ill. and references. KW - Finite-Elemente-Methode KW - Limit analysis KW - Shakedown analysis KW - First-order reliability method KW - second-order reliability method KW - Sensitivity Y1 - 2008 ER - TY - CHAP A1 - Heitzer, M. A1 - Staat, Manfred T1 - Direct FEM approach to design-by-analysis of pressurized components N2 - Abstracts of the ACHEMA 2000 - International Meeting on Chemical Engineering, Environmental Protection and Biotechnology, May 22 - 27, 2000. Frankfurt am Main. Achema 2000 : special edition / Linde. [Ed.: Linde AG. Red.: Volker R. Leski]. - Wiesbaden : Linde AG, 2000. - 56 p. : Ill., . - pp: 79 - 81 N2 - Abstracts der ACHEMA 2000 - International Meeting on Chemical Engineering, Environmental Protection and Biotechnology, May 22 - 27, 2000. Frankfurt am Main. KW - Finite-Elemente-Methode KW - Finite-Elemente-Methode KW - limit analysis KW - shakedown analysis Y1 - 2000 ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, M. A1 - Hicken, E. F. T1 - LISA, ein europäisches Projekt zur direkten Berechnung der Tragfähigkeit duktiler Strukturen N2 - Traglast- und Einspielanalysen sind vereinfachte doch exakte Verfahren der Plastizität, die neben ausreichender Verformbarkeit keine einschränkenden Voraussetzungen beinhalten. Die Vereinfachungen betreffen die Beschaffung der Daten und Modelle für Details der Lastgeschichte und des Stoffverhaltens. Anders als die klassische Behandlung nichtlinearer Probleme der Strukturmechanik führt die Methode auf Optimierungsprobleme. Diese sind bei realistischen FEM-Modellen sehr groß. Das hat die industrielle Anwendung der Traglast- und Einspielanalysen stark verzögert. Diese Situation wird durch das Brite-EuRam Projekt LISA grundlegend geändert. Die Autoren möchten der Europäischen Kommission an dieser Stelle für die Förderung ausdrücklich danken. In LISA entsteht auf der Basis des industriellen FEM-Programms PERMAS ein Verfahren zur direkten Berechnung der Tragfähigkeit duktiler Strukturen. Damit kann der Betriebsbereich von Komponenten und Bauwerken auf den plastischen Bereich erweitert werden, ohne den Aufwand gegenüber elastischen Analysen wesentlich zu erhöhen. Die beachtlichen Rechenzeitgewinne erlauben Parameterstudien und die Berechnung von Interaktionsdiagrammen, die einen schnellen Überblick über mögliche Betriebsbereiche vermitteln. Es zeigt sich, daß abhängig von der Komponente und ihren Belastungen teilweise entscheidende Sicherheitsgewinne zur Erweiterung der Betriebsbereiche erzielt werden können. Das Vorgehen erfordert vom Anwender oft ein gewisses Umdenken. Es werden keine Spannungen berechnet, um damit Sicherheit und Lebensdauer zu interpretieren. Statt dessen berechnet man direkt die gesuchte Sicherheit. Der Post-Prozessor wird nur noch zur Modell- und Rechenkontrolle benötigt. Das Vorgehen ist änhlich der Stabilitätsanalyse (Knicken, Beulen). Durch namhafte industrielle Projektpartner werden Validierung und die Anwendbarkeit auf eine breite Palette technischer Probleme garantiert. Die ebenfalls in LISA geplante Zuverlässigkeitsanalyse ist erst auf der Basis direkter Verfahren effektiv möglich. Ohne Traglast- und Einspielanalyse ist plastische Strukturoptimierung auch heute kaum durchführbar. KW - Finite-Elemente-Methode KW - Traglastanalyse KW - Einspielanalyse KW - limit analysis KW - shakedown analysis Y1 - 1998 ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael T1 - Direkte FEM-Berechnung der Tragfähigkeit hochbeanspruchter passiver Komponenten T1 - Direct FEM-computation of load carrying capacity of highly loaded passive components N2 - Genaue Kenntnis der Spannungen und Verformungen in passiven Komponenten gewinnt man mit detailierten inelastischen FEM Analysen. Die lokale Beanspruchung läßt sich aber nicht direkt mit einer Beanspruchbarkeit im strukturmechanischen Sinne vergleichen. Konzentriert man sich auf die Frage nach der Tragfähigkeit, dann vereinfacht sich die Analyse. Im Rahmen der Plastizitätstheorie berechnen Traglast- und Einspielanalyse die tragbaren Lasten direkt und exakt. In diesem Beitrag wird eine Implementierung der Traglast- und Einspielsätze in ein allgemeines FEM Programm vorgestellt, mit der die Tragfähigkeit passiver Komponenten direkt berechnet wird. Die benutzten Konzepte werden in Bezug auf die übliche Strukturanalyse erläutert. Beispiele mit lokal hoher Beanspruchung verdeutlichen die Anwendung der FEM basierten Traglast- und Einspielanalysen. Die berechneten Interaktionsdiagramme geben einen guten Überblick über die möglichen Betriebsbereiche passiver Komponenten. Die Traglastanalyse bietet auch einen strukturmechanischen Zugang zur Kollapslast rißbehafteter Komponenten aus hochzähem Material. KW - Finite-Elemente-Methode KW - Tragfähigkeit KW - FEM-Programm KW - FEM-computation KW - load carrying capacity Y1 - 1997 ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael T1 - Limit and shakedown analysis for plastic design N2 - Limit and shakedown theorems are exact theories of classical plasticity for the direct computation of safety factors or of the load carrying capacity under constant and varying loads. Simple versions of limit and shakedown analysis are the basis of all design codes for pressure vessels and pipings. Using Finite Element Methods more realistic modeling can be used for a more rational design. The methods can be extended to yield optimum plastic design. In this paper we present a first implementation in FE of limit and shakedown analyses for perfectly plastic material. Limit and shakedown analyses are done of a pipe–junction and a interaction diagram is calculated. The results are in good correspondence with the analytic solution we give in the appendix. KW - Einspielen KW - Traglast KW - Finite-Elemente-Methode KW - Traglastanalyse KW - Einspielanalyse KW - FEM KW - limit analysis KW - shakedown analysis Y1 - 1997 ER - TY - CHAP A1 - Lang, H. A1 - Wirtz, K. A1 - Heitzer, Michael A1 - Staat, Manfred A1 - Oettel, R. T1 - Zyklische Einspielversuche zur Verifikation von Shakedown-Analysen mittels FEM T1 - Cyclic plastic deformation test to verify FEM-based shakedown analysis N2 - Im Rahmen von Ermüdungsanalysen ist nachzuweisen, daß die thermisch bedingten fortschreitenden Deformationen begrenzt bleiben. Hierzu ist die Abgrenzung des Shakedown-Bereiches (Einspielen) vom Ratchetting-Bereich (fortschreitende Deformation) von Interesse. Im Rahmen eines EU-geförderten Forschungsvorhabens wurden Experimente mit einem 4-Stab-Modell durchgeführt. Das Experiment bestand aus einem wassergekühlten inneren Rohr und drei isolierten und beheizbaren äußeren Probestäben. Das System wurde durch alternierende Axialkräfte, denen alternierende Temperaturen an den äußeren Stäben überlagert wurden, belastet. Die Versuchsparameter wurden teilweise nach vorausgegangenen Einspielanalysen gewählt. Während der Versuchsdurchführung wurden Temperaturen und Dehnungen zeitabhängig gemessen. Begleitend und nachfolgend zur Versuchsdurchführung wurden die Belastungen und die daraus resultierenden Beanspruchungen nachvollzogen. Bei dieser inkrementellen elasto-plastischen Analyse mit dem Programm ANSYS wurden unterschiedliche Werkstoffmodelle angesetzt. Die Ergebnisse dieser Simulationsberechnung dienen dazu, die Shakedown-Analysen mittels FE-Methode zu verifizieren. KW - Einspielen KW - Traglast KW - Finite-Elemente-Methode KW - Shakedown KW - shakedown analysis KW - plastic deformation Y1 - 1999 ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael A1 - Hicken, E. F. T1 - LISA - ein europäisches Projekt zur FEM-basierten Traglast- und Einspielanalyse T1 - LISA - a European project for FEM-based limit and shakedown analysis N2 - Traglast- und Einspielanalysen sind vereinfachte doch exakte Verfahren der Plastizität, die neben ausreichender Verformbarkeit keine einschränkenden Voraussetzungen beinhalten. Die Vereinfachungen betreffen die Beschaffung der Daten und Modelle für Details der Lastgeschichte und des Stoffverhaltens. Anders als die klassische Behandlung nichtlinearer Probleme der Strukturmechanik führt die Methode auf Optimierungsprobleme. Diese sind bei realistischen FEM-Modellen sehr groß. Das hat die industrielle Anwendung der Traglast- und Einspielanalysen stark verzögert. Diese Situation wird durch das Brite-EuRam Projekt LISA grundlegend geändert. In LISA entsteht auf der Basis des industriellen FEM-Programms PERMAS ein Verfahren zur direkten Berechnung der Tragfähigkeit duktiler Strukturen. Damit kann der Betriebsbereich von Komponenten und Bauwerken auf den plastischen Bereich erweitert werden, ohne den Aufwand gegenüber elastischen Analysen wesentlich zu erhöhen. Die beachtlichen Rechenzeitgewinne erlauben Parameterstudien und die Berechnung von Interaktionsdiagrammen, die einen schnellen Überblick über mögliche Betriebsbereiche vermitteln. Es zeigt sich, daß abhängig von der Komponente und ihren Belastungen teilweise entscheidende Sicherheitsgewinne zur Erweiterung der Betriebsbereiche erzielt werden können. Das Vorgehen erfordert vom Anwender oft ein gewisses Umdenken. Es werden keine Spannungen berechnet, um damit Sicherheit und Lebensdauer zu interpretieren. Statt dessen berechnet man direkt die gesuchte Sicherheit. Der Post-Prozessor wird nur noch zur Modell- und Rechenkontrolle benötigt. Das Vorgehen ist ähnlich der Stabilitätsanalyse (Knicken, Beulen). Durch namhafte industrielle Projektpartner werden Validierung und die Anwendbarkeit auf eine breite Palette technischer Probleme garantiert. Die ebenfalls in LISA entwickelten Zuverlässigkeitsanalysen sind nichlinear erst auf der Basis direkter Verfahren effektiv möglich. Ohne Traglast- und Einspielanalyse ist plastische Strukturoptimierung auch heute kaum durchführbar. Auf die vorgesehenen Erweiterungen der Werkstoffmodellierung für nichtlineare Verfestigung und für Schädigung konnte hier nicht eingegangen werden. Es herrscht ein deutlicher Mangel an Experimenten zum Nachweis der Grenzen zwischen elastischem Einspielen und dem Versagen durch LCF oder durch Ratchetting. KW - Einspielen KW - Traglast KW - Finite-Elemente-Methode KW - LISA KW - limit analysis KW - shakedown analysis Y1 - 1999 ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael A1 - Reinders, H. A1 - Schubert, F. T1 - Einspielen und Ratchetting bei Zug- und Torsionsbelastung: Analyse und Experimente T1 - Shakedown and ratchetting under tension-torsion loadings: analysis and experiments N2 - Traglast- und Einspielanalysen sind vereinfachte doch exakte Verfahren der klassischen Plastizitätstheorie, die neben ausreichender Verformbarkeit keine einschränkenden Voraussetzungen beinhalten. Die Vereinfachungen betreffen die Beschaffung der Daten und Modelle für Details der Lastgeschichte und des Stoffverhaltens. Eine FEM-basierte Traglast- und Einspielanalyse für ideal plastisches Material wurde auf ein kinematisch verfestigendes Materialgesetz erweitert und in das Finite Element Programm PERMAS implementiert. In einem einfachen Zug-Torsionsexperiment wurde eine Hohlprobe mit konstanter Torsion und zyklischer Zugbelastung beansprucht, um die neue Implementierung zu verifizieren. Es konnte gezeigt werden, dass die Einspielanalyse gut mit den experimentellen Ergebnissen übereinstimmt. Bei Verfestigung lassen sich wesentlich größere Sicherheiten nachweisen. Dieses Potential bedarf weiterer experimenteller Absicherung. Parallel dazu ist die Eisnpieltheorie auf fortschrittliche Verfestigungsansätze zu erweitern. KW - Zug-Druck-Beanspruchung KW - Einspielen KW - Ratcheting KW - Torsion KW - Zug-Druck-Belastung KW - Torsionsbelastung KW - shakedown KW - ratchetting KW - tension–torsion loading Y1 - 2001 ER - TY - CHAP A1 - Ballmann, J. A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred T1 - High stress intensities in focussing zones of waves N2 - The propagation of mechanical waves in plates of isotropic elastic material is investigated. After a short introduction to the understanding of focussing of stress waves in a plate with a curved boundary the method of characteristics is applied to a plate of hyperelastic material. Using this method the propagation of acceleration waves is discussed. Based on this a numerical difference scheme is developed for solving initial-boundary-value problems and applied to two examples: propagation of a point disturbance in a homogeneously finitely strained non-linear elastic plate and geometrical focussing in al linear elastic plate. KW - Technische Mechanik KW - Wellen KW - mechanical waves Y1 - 1985 U6 - http://dx.doi.org/10.1016/B978-0-444-42520-1.50015-3 ER - TY - CHAP A1 - Tran, Thanh Ngoc A1 - Novacek, V. A1 - Tolba, R. A1 - Klinge, U. A1 - Turquier, F. A1 - Staat, Manfred T1 - Experimental and Computational approach to study colorectal anastomosis. ISB2011, Proceedings of the XXIII Congress of the International Society of Biomechanics, Brussels, Belgium, July 3-7, 2011 N2 - Summary: This paper presents a methodology to study and understand the mechanics of stapled anastomotic behaviors by combining empirical experimentation and finite element analysis. Performance of stapled anastomosis is studied in terms of leakage and numerical results which are compared to in vitro experiments performed on fresh porcine tissue. Results suggest that leaks occur between the tissue and staple legs penetrating through the tissue. KW - Anastomose KW - Finite-Elemente-Methode KW - Biomechanik KW - Anastomosis KW - Finite element method KW - Biomechanics Y1 - 2011 ER - TY - CHAP A1 - Burgazzi, L. A1 - Fiorini, F. A1 - De Magistris, W. (u.a.) A1 - Lensa, W. von A1 - Staat, Manfred A1 - Altes, J. T1 - Reliability Assessment of Passive Safety Systems T2 - Proceedings of the 6th International Conference on Nuclear Engineering : ICONE : May 10 - 14, 1998, San Diego, Calif. Y1 - 1998 N1 - CD-ROM PB - American Society of Mechanical Engineers CY - New York ER - TY - JOUR A1 - Staat, Manfred A1 - Fiorini, G. L. A1 - Lensa, W. von A1 - Burgazzi, L. T1 - Reliability Methods for Passive Safety Functions JF - Proceedings of the SMiRT 14 Post Conference Seminar No 18 on Passive Safety Features in Nuclear Installations Y1 - 1997 CY - Pisa ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Limit and Shakedown Analysis for Plastic Safety of Complex Structures JF - Transactions of the 14th International Conference on Structural Dynamics in Reactor Technology (SMiRT-14) / Livolant, M. [ed] Y1 - 1997 N1 - Vol. B, Paper B02/2 SP - 33 EP - 40 CY - Lyon ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Limit and Shakedown Analysis Using a General Purpose Finite Element Code JF - Proceedings of NAFEMS World Congress '97 on Design, Simulation & Optimisation : reliability & applicability of computational methods ; Stuttgart, Germany, 9 - 11 April 1997 Y1 - 1997 SN - 1-87437-620-4 SP - 522 EP - 533 PB - NAFEMS CY - Glasgow ER - TY - JOUR A1 - Staat, Manfred T1 - Problems and Chances for Probabilistic Fracture Mechanics in the Analysis of Steel Pressure Boundary Reliability JF - Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994 Y1 - 1996 N1 - IAEA-TECDOC-920 ; Onlinezugriff erfolgt auf die überarb. Ausg. 2006 SP - 43 EP - 55 CY - Vienna ER - TY - JOUR A1 - Staat, Manfred T1 - Sensitivity of and Influences on the Reliability of an HTR-Module Primary Circuit Pressure Boundary JF - Transactions of the 12th International Conference on Structural Mechanics in Reactor Technology (SMiRT-12) / Kussmaul, K. [ed] Y1 - 1993 SN - 0-444-81515-5 N1 - Vol. M, Paper MG10/2 SP - 147 EP - 152 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Staat, Manfred T1 - Reliability of the Primary Circuit Pressure Boundary of an HTR-Module under Accident Conditions JF - Safety and reliability assessment : an integral approach ; ESREL'93 ; proceedings of the European Safety and Reliability Conference, Munich, Germany, May 10th - 12th 1993 / Kafka, P. [ed] Y1 - 1993 SN - 0-444-81561-9 SP - 331 EP - 342 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Staat, Manfred T1 - Probabilistische Bewertung des bruchmechanischen Verhaltens der Primärkreisdruckumschließung eines HTR-Moduls Y1 - 1992 N1 - 18. MPA-Seminar : Sicherheit und Verfügbarkeit in der Anlagentechnik mit dem Schwerpunkt Kernenergie. Stuttgart (1992), 27.1-27.18 ER - TY - JOUR A1 - Staat, Manfred T1 - Versagenswahrscheinlichkeit der Primärkreisdruckumschließung eines HTR-Moduls zur Prozeßwärmegewinnung unter Störfallbedingungen bei verschiedenen Versagensmoden Y1 - 1991 N1 - 17. MPA-Seminar : Sicherheit und Verfügbarkeit in der Anlagentechnik mit dem Schwerpunkt Kerntechnik, Stuttgart (1991), 22.1-22.20 ER - TY - JOUR A1 - Staat, Manfred T1 - Some Achievements of the European Project LISA for FEM Based Limit and Shakedown Analysis JF - Computational mechanics : developments and applications, 2002 : presented at the 2002 ASME Pressure Vessels and Piping Conference, Vancouver, British Columbia, Canada, August 5 - 9. / Badie, N. [ed] Y1 - 2002 SN - 0791846520 N1 - Serie PVP ; vol. 441. SP - 177 EP - 185 PB - American Society of Mechanical Engineers CY - New York ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Traglastanalyse - ein strukturmechanisches Verfahren zur Beurteilung von gerissenen Bauteilen und Verbindungen JF - Festigkeits- und Bruchverhalten von Fügeverbindungen : 32. Tagung des DVM-Arbeitskreises Bruchvorgänge ; 22. und 23. Februar 2000 in Berlin / Richard, H. A. [Hrsg] Y1 - 2000 N1 - DVM-Bericht 232 SP - 183 EP - 192 PB - Deutscher Verband für Materialforschung und -prüfung CY - Berlin ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Reliability Analysis of Elasto-Plastic Structures under Variable Loads JF - Inelastic analysis of structures under variable loads : theory and engineering applications / Maier, G.; Weichert, D. [ed] Y1 - 2000 SN - 0-7923-6645-X SP - 269 EP - 288 PB - Kluwer Academic Publ. CY - Dordrecht ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Direct FEM approach to design-by-analysis of pressurized components JF - Achema 2000 : Sonderausgabe / Linde. [Hrsg.: Linde AG. Red.: Volker R. Leski] Y1 - 2000 SP - 79 EP - 81 PB - Linde AG CY - Wiesbaden ER - TY - BOOK A1 - Staat, Manfred A1 - Heitzer, M. A1 - Yan, Ai-Min A1 - Khoi, Vu Duc A1 - Nguyen, Dang Hung A1 - Valdoire, F. A1 - Lahousse, A. T1 - Limit Analysis of Defects Y1 - 2000 SN - 0944-2952 N1 - Bericht des Forschungszentrums, Jül-3746, Jülich (2000) PB - Forschungszentrum Jülich CY - Jülich ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Structural Reliability Analysis of Elasto-Plastic Structures JF - Safety and reliability : proceedings of ESREL '99, the Tenth European Conference on Safety and Reliability, Munich-Garching, Germany, 13 - 17 September 1999 / Schuëller, G. I.; Kafka, P. [eds] Y1 - 1999 SN - 90-5809-109-0 SP - 513 EP - 518 PB - Balkema CY - Rotterdam ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. A1 - Hicken, E.F. T1 - LISA, ein europäisches Projekt zur direkten Berechnung der Tragfähigkeit duktiler Strukturen. Y1 - 1998 N1 - PERMAS–Benutzertagung, 8.–9.10.1998, Stuttgart (1998) ER - TY - JOUR A1 - Staat, Manfred T1 - Versagenswahrscheinlichkeit der Primärkreisdruckumschließung eines HTR-Moduls zur Prozeßwärmegewinnung unter Störfallbedingungen JF - Jahrestagung Kerntechnik '91 / Kerntechnische Gesellschaft e.V. ; Deutsches Atomforum e.V Y1 - 1991 SP - 123 EP - 126 PB - INFORUM CY - Bonn ER - TY - JOUR A1 - Staat, Manfred A1 - Wolters, J A1 - Bongarts, W. A1 - Hennings, W. (u.a.) T1 - Überarbeitete probabilistisch orientierte Sicherheitsanalyse für den HTR-Modul JF - Jahrestagung Kerntechnik '90 / Kerntechnische Gesellschaft e.V. ; Deutsches Atomforum e.V Y1 - 1990 SP - 143 EP - 146 PB - INFORUM CY - Bonn ER - TY - JOUR A1 - Staat, Manfred A1 - Ballmann, J. T1 - Zur Problematik tensorieller Verallgemeinerungen einachsiger nichtlinearer Materialgesetze JF - Zeitschrift für angewandte Mathematik und Mechanik : ZAMM. 69 (1989), H. 2 Y1 - 1989 SN - 0946-8463 U6 - http://dx.doi.org/10.1515/9783112553169-006 SP - 73 EP - 81 ER - TY - JOUR A1 - Staat, Manfred A1 - Ballmann, J. T1 - Wave Propagation and Focussing in Plates JF - Impact loading and dynamic behaviour of materials : Papers presented at the International Conference on Impact Loading and Dynamic Behaviour of Materials, Vol. 2 / Chiem, C. Y.; Kunze, L. (u.a.) [eds] Y1 - 1988 PB - DGM Informationsges. CY - Oberursel ER - TY - THES A1 - Staat, Manfred T1 - Nichtlineare Wellen in elastischen Scheiben Y1 - 1987 N1 - Aachen, Techn. Hochsch., Diss., 1987 CY - Aachen ER - TY - JOUR A1 - Staat, Manfred T1 - Anisotrope Wellenausbreitung in isotropen hyperelastischen Scheiben JF - Zeitschrift für angewandte Mathematik und Mechanik : ZAMM. 67 (1987), H. 4 Y1 - 1987 SN - 0946-8463 SP - T241 EP - T243 ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. A1 - Lang, H. A1 - Wirtz, K. T1 - Direct Finite Element Route for Design-by-Analysis of Pressure Components JF - International Journal of Pressure Vessels and Piping. 82 (2005), H. 1 Y1 - 2005 SN - 0308-0161 SP - 61 EP - 67 ER - TY - JOUR A1 - Staat, Manfred T1 - Plastic collapse analysis of longitudinally flawed pipes and vessels JF - Nuclear Engineering and Design. 234 (2004), H. 1-3 Y1 - 2004 SN - 0029-5493 SP - 25 EP - 43 ER - TY - JOUR A1 - Staat, Manfred A1 - Kühn, R. A1 - Hauger, W. A1 - Sponagel, Stefan T1 - An Interpretation of Wolff’s Law JF - Biomedizinische Technik. 49 (2004) Y1 - 2004 SN - 0932-4666 N1 - Ergänzungsband 2, Teil 2 SP - 1020 EP - 1021 ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. A1 - Reiners, H. A1 - Schubert, F. T1 - Shakedown and ratchetting under tension–torsion loadings: analysis and experiments JF - Nuclear Engineering and Design. 225 (2003), H. 1 Y1 - 2003 SN - 0029-5493 SP - 11 EP - 26 ER - TY - JOUR A1 - Staat, Manfred A1 - Schwartz, M. A1 - Lang, H. A1 - Wirtz, K. A1 - Heitzer, M. T1 - Design by Analysis of Pressure Components by non-linear Optimization JF - The 10th International Conference on Pressure Vessel Technology, July 7-10, 2003, Vienna, Austria, Proceedings ICPVT-10 / Zeman, J. L. [ed] Y1 - 2003 SN - 3950152814 SP - 59 EP - 65 PB - ÖGS, Österreichische Gesellschaft für Schweißtechnik CY - Wien ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Limit and Shakedown Analysis with Uncertain Data JF - Stochastic optimization techniques : numerical methods and technical applications / Marti, K. [ed] Y1 - 2002 SN - 3-540-42889-5 SP - 241 EP - 254 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Probabilistic limit and shakedown problems JF - Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M; Heitzer, M. Y1 - 2003 SN - 3-00-010001-6 SP - 217 EP - 268 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, M. T1 - Basis reduction technique for limit and shakedown problems T2 - Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M.; Heitzer, M. Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0001-2018112115 SN - 3-00-010001-6 SP - 1 EP - 55 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - JOUR A1 - Staat, Manfred A1 - Ballmann, J. T1 - Anisotrope Ausbreitung und Fokussierung von Beschleunigungswellen in vorgespannten nichtlinearelastischen Scheiben JF - Wellenfokussierung, Kolloquium des SFB 27, RWTH Aachen Y1 - 1985 SP - 140 EP - 158 CY - Aachen ER - TY - JOUR A1 - Staat, Manfred T1 - Local and global collapse pressure of longitudinally flawed pipes and cylindrical vessels JF - International Journal of Pressure Vessels and Piping. 82 (2005), H. 3 Y1 - 2005 SN - 0308-0161 SP - 217 EP - 225 ER - TY - JOUR A1 - Staat, Manfred A1 - Vu, Duc-Khoi T1 - An Algorithm for Shakedown Analysis for Materials with Temperature Dependent Yield Stress JF - Proceedings in Applied Mathematics and Mechanics (PAMM). 4 (2004), H. 1 Y1 - 2004 SN - 1617-7061 SP - 231 EP - 233 ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - FEM-computation of load carrying capacity of highly loaded passive components by direct methods. Heitzer, M. ; Staat, M. JF - Nuclear Engineering and Design. 193 (1999), H. 3 Y1 - 1999 SN - 0029-5493 SP - 349 EP - 358 ER - TY - JOUR A1 - Staat, Manfred T1 - Failure probabilities of the primary circuit pressure boundary of an HTR-Module for process heat generation under accident conditions for different failure modes JF - Nuclear Engineering and Design. 144 (1993), H. 1 Y1 - 1993 SN - 0029-5493 SP - 53 EP - 67 ER - TY - JOUR A1 - Staat, Manfred A1 - Vu, Khoi Duc T1 - Limit loads of circumferentially flawed pipes and cylindrical vessels under internal pressure JF - International Journal of Pressure Vessels and Piping. 83 (2006), H. 3 Y1 - 2006 SN - 0308-0161 SP - 188 EP - 196 ER - TY - JOUR A1 - Staat, Manfred T1 - Reliability of an HTR-module primary circuit pressure boundary Influences, sensitivity, and comparison with a PWR JF - Nuclear Engineering and Design. 158 (1995), H. 2-3 Y1 - 1995 SN - 0029-5493 SP - 333 EP - 340 ER - TY - JOUR A1 - Staat, Manfred T1 - Probabilistic assessment of the fracture mechanics behaviour of an HTR-module primary circuit pressure boundary JF - Nuclear Engineering and Design. 160 (1996), H. 1-2 Y1 - 1996 SN - 0029-5493 SP - 221 EP - 236 ER - TY - JOUR A1 - Staat, Manfred A1 - Vu, Duc-Khoi T1 - Limit analysis of flaws in pressurized pipes and cylindrical vessels. Part I: Axial defects JF - Engineering Fracture Mechanics. 74 (2007), H. 3 Y1 - 2007 SN - 0013-7944 SP - 431 EP - 450 ER - TY - JOUR A1 - Vu, Duc Khoi A1 - Staat, Manfred A1 - Tran, Ich Thinh T1 - Analysis of pressure equipment by application of the primal-dual theory of shakedown JF - Communications in Numerical Methods in Engineering. 23 (2007), H. 3 Y1 - 2007 SN - 1069-8299 SP - 213 EP - 225 ER - TY - JOUR A1 - Vu, Duc Khoi A1 - Staat, Manfred T1 - Shakedown analysis of structures made of materials with temperature-dependent yield stress JF - International Journal of Solids and Structures. 44 (2007), H. 13 Y1 - 2007 SN - 0020-7683 SP - 4524 EP - 4540 ER - TY - JOUR A1 - Staat, Manfred A1 - Baroud, G. A1 - Topcu, M. A1 - Sponagel, Stefan T1 - Soft Materials in Technology and Biology – Characteristics, Properties, and Parameter Identification JF - Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.) Y1 - 2008 SN - 978-3-540-75408-4 SP - 253 EP - 315 PB - Springer CY - Berlin ER - TY - JOUR A1 - Vant, Christianne A1 - Staat, Manfred A1 - Baroud, Gamal T1 - Percutaneous Vertebroplasty: A Review of Two Intraoperative Complications JF - Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.) Y1 - 2008 SN - 978-3-540-75408-4 SP - 527 EP - 539 PB - Springer CY - Berlin ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Kreißig, R. A1 - Vu, Duc Khoi A1 - Staat, Manfred T1 - Upper bound limit and shakedown analysis of shells using the exact Ilyushin yield surface JF - Computer & Structures. 86 (2008) Y1 - 2008 SN - 0045-7949 SP - 1683 EP - 1695 ER - TY - JOUR A1 - Staat, Manfred A1 - Tran, Thanh Ngoc A1 - Kreißig, R. T1 - Load bearing capacity of thin shell structures made of elastoplastic material by direct methods JF - Technische Mechanik. 28 (2008), H. 3-4 Y1 - 2008 SP - 299 EP - 309 ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Kreißig, R. A1 - Staat, Manfred T1 - Probabilistic limit and shakedown analysis of thin plates and shells JF - Structural safety. 31 (2009), H. 1 Y1 - 2009 SN - 0167-4730 SP - 1 EP - 18 PB - - ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Pham, Phu Tinh A1 - Vu, D. K. A1 - Staat, Manfred T1 - Reliability Analysis of Inelastic Shell Structures Under Variable Loads JF - Limit States of Materials and Structures : Direct Methods / Hrsg. Dieter Weichert; Hrsg. Alan Ponter Y1 - 2009 SN - 978-1-4020-9633-4 SP - 135 EP - 156 PB - Springer Netherland CY - Berlin ER - TY - JOUR A1 - Ullrich, Sebastian A1 - Grottke, Oliver A1 - Rossaint, Rolf A1 - Staat, Manfred A1 - Deserno, Thomas M. A1 - Kuhlen, Torsten T1 - Virtual Needle Simulation with Haptics for Regional Anaesthesia Y1 - 2010 N1 - IEEE Virtual Reality 2010, Workshop on Medical Virtual Environments, Waltham, MA, USA, March 21, 2010 SP - 1 EP - 3 ER - TY - JOUR A1 - Nguyen, N.-H. A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred T1 - A hyperelastic model of biological tissue materials in tubular organs Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 12 ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Vu, Khoi Duc A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - A primal-dual algorithm for shakedown analysis of elastic-plastic bounded linearly kinematic hardening bodies Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 7 ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 7 ER - TY - JOUR A1 - Grottke, O. A1 - Braunschweig, T. A1 - Philippen, B. A1 - Gatzweiler, Karl-Heinz A1 - Gronloh, N. A1 - Staat, Manfred A1 - Rossaint, R. A1 - Tolba, R. T1 - A New Model for Blunt Liver Injuries in the Swine JF - European Surgical Research. 44 (2010), H. 2 Y1 - 2010 SN - 1421-9921 SP - 65 EP - 73 ER - TY - JOUR A1 - Staat, Manfred A1 - Sponagel, Stefan A1 - Nguyen, Nhu Huynh T1 - Experiment and material model for soft tissue materials JF - Constitutive models for rubber VI : proceedings of the sixth European Conference on Constitutive Models for Rubber, Dresden, Germany, 7 - 10 September 2009 / eds. Gert Heinrich ... Y1 - 2010 SN - 978-0-415-56327-7 SP - 465 EP - 470 PB - CRC Press CY - Boca Raton [u.a.] ER - TY - JOUR A1 - Staat, Manfred A1 - Vu, Duc Khoi T1 - Limit analysis of flaws in pressurized pipes and cylindrical vessels Part II: Circumferential defects JF - Engineering Fracture Mechanics ; 97(2013), H. 1 Y1 - 2012 SN - 0013-7944 VL - 2013 SP - 314 EP - 333 PB - - ER - TY - JOUR A1 - Doorschodt, B. M. A1 - Schreinemachers, M. C. J. M. A1 - Behbahani, Mehdi A1 - Florquin, S. A1 - Weis, J. A1 - Staat, Manfred A1 - Tolba, R. H. T1 - Hypothermic machine perfusion of kidney grafts: which pressure is preferred JF - Annals of Biomedical Engineering. 39 (2011), H. 3 Y1 - 2011 SN - 1573-9686 SP - 1051 EP - 1059 PB - Springer CY - Berlin ER - TY - JOUR A1 - Staat, Manfred A1 - Trenz, Eva A1 - Lohmann, Philipp A1 - Frotscher, Ralf A1 - Klinge, Uwe A1 - Tabaza, Ruth A1 - Kirschner-Hermanns, Ruth T1 - New measurements to compare soft tissue anchoring systems in pelvic floor surgery JF - Journal of Biomedical Materials Research Part B: Applied Biomaterials. 100B (2012), H. 4 Y1 - 2012 SN - 1552-4981 SP - 924 EP - 933 ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - An Upper Bound Algorithm for Limit and Shakedown Analysis of Bounded Linearly Kinematic Hardening Structures JF - Limit State of Materials and Structures : Direct Methods 2. Saxcé, Géry de (Hrsg.) Y1 - 2013 SN - 978-94-007-5424-9 SP - 71 EP - 87 PB - Springer CY - Dordrecht ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - An Edge-Based Smoothed Finite Element Method for Primal-Dual Shakedown Analysis of Structures Under Uncertainties JF - Limit State of Materials and Structures : Direct Methods 2. Saxcé, Géry de (Hrsg.) Y1 - 2013 SN - 978-94-007-5424-9 SP - 89 EP - 102 PB - Springer CY - Dordrecht ER - TY - JOUR A1 - Hasan, Istabrak A1 - Keil, Ludger A1 - Staat, Manfred A1 - Wahl, Gerhard A1 - Bourauel, Christoph T1 - Determination of the frictional coefficient of the implant-antler interface : experimental approach JF - Biomedical Engineering / Biomedizinische Technik N2 - The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5–0.7 and 0.3–0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens. Y1 - 2012 SN - 1862-278X VL - 57 IS - 5 SP - 359 EP - 363 PB - De Gruyter CY - Berlin ER - TY - CHAP A1 - Nix, Yvonne A1 - Frotscher, Ralf A1 - Staat, Manfred ED - Eberhardsteiner, J. T1 - Implementation of the edge-based smoothed extended finite element method T2 - Proceedings 6th European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Vienna, Austria, September 10-14, 2012 Y1 - 2012 ER - TY - CHAP A1 - Frotscher, Ralf A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred ED - Eberhardsteiner, J. T1 - Application of an edge-based smoothed finite element method on geometrically non-linear plates of non-linear material T2 - Proceedings European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Y1 - 2012 N1 - 6th European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Vienna, Austria, September 10-14, 2012 ER - TY - CHAP A1 - Duong, Minh Tuan A1 - Nguyen, Nhu Huynh A1 - Staat, Manfred ED - Eberhardsteiner, J. T1 - Numerical stability enhancement of modeling hyperelastic materials T2 - Proceedings European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Y1 - 2012 N1 - 6th European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Vienna, Austria, September 10-14, 2012 ER - TY - CHAP A1 - Tran, Thanh Ngoc A1 - Staat, Manfred ED - Eberhardsteiner, J. T1 - A primal-dual shakedown analysis of 3D structures using the face-based smoothed finite element method T2 - Proceedings European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Y1 - 2012 N1 - 6th European Congress on Computational Methods in Applied Sciences and Engineering (ECCOMAS 2012) Vienna, Austria, September 10-14, 2012 ER - TY - CHAP A1 - Pham, Phu Tinh A1 - Nguyen, Thanh Ngoc A1 - Staat, Manfred T1 - FEM based shakedown analysis of hardening structures T2 - Proceedings International Conference on Advances in Computational Mechanics (ACOME) Y1 - 2012 N1 - International Conference on Advances in Computational Mechanics (ACOME), August 14-16, 2012, Ho Chi Minh City, Vietnam SP - 870 EP - 882 ER - TY - CHAP A1 - Staat, Manfred T1 - Limit and shakedown analysis under uncertainty T2 - Proceedings International Conference on Advances in Computational Mechanics (ACOME) Y1 - 2012 N1 - International Conference on Advances in Computational Mechanics (ACOME), August 14-16, 2012, Ho Chi Minh City, Vietnam SP - 837 EP - 861 ER - TY - CHAP A1 - Frotscher, Ralf A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred ED - Holzapfel, Gerhard A. T1 - Effectiveness of the edge-based smoothed finite element method applied to soft biological tissues T2 - ESMC-2012 - 8th European Solid Mechanics Conference, Graz, Austria, July 9-13, 2012 Y1 - 2012 SN - 978-3-85125-223-1 PB - Verlag d. Technischen Universität Graz CY - Graz ER - TY - CHAP A1 - Duong, Minh Tuan A1 - Nguyen, Nhu Hunyh A1 - Staat, Manfred T1 - Finite Element Implementation of a 3D Fung-type Model T2 - ESMC-2012 - 8th European Solid Mechanics Conference, Graz, Austria, July 9-13, 2012 Y1 - 2012 SN - 978-3-85125-223-1 PB - Verlag d. Technischen Universität Graz CY - Graz ER - TY - JOUR A1 - Staat, Manfred T1 - Limit and shakedown analysis under uncertainty JF - International journal of computational methods : IJCM Y1 - 2013 SN - 0219-8762 SP - Publ. online PB - World Scientific Publishing CY - Singapore ER - TY - CHAP A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - Shakedown analysis of Reissner-Mindlin plates using the edge-based smoothed finite element method T2 - Direct methods for limit states in structures and materials / Dieter Weichert ; Alan Ponter, ed. N2 - This paper concerns the development of a primal-dual algorithm for limit and shakedown analysis of Reissner-Mindlin plates made of von Mises material. At each optimization iteration, the lower bound of the shakedown load multiplier is calculated simultaneously with the upper bound using the duality theory. An edge-based smoothed finite element method (ES-FEM) combined with the discrete shear gap (DSG) technique is used to improve the accuracy of the solutions and to avoid the transverse shear locking behaviour. The method not only possesses all inherent features of convergence and accuracy from ES-FEM, but also ensures that the total number of variables in the optimization problem is kept to a minimum compared with the standard finite element formulation. Numerical examples are presented to demonstrate the effectiveness of the present method. Y1 - 2014 SN - 978-94-007-6826-0 (Print) 978-94-007-6827-7 (Online) U6 - http://dx.doi.org/10.1007/978-94-007-6827-7_5 SP - 101 EP - 117 PB - Springer CY - Dordrecht [u.a.] ER - TY - CHAP A1 - Frotscher, Ralf A1 - Goßmann, Matthias A1 - Temiz Artmann, Aysegül A1 - Staat, Manfred T1 - Simulation of cardiac cell-seeded membranes using the edge-based smoothed FEM T2 - 1st International Conference "Shell and Membrane Theories in Mechanics and Biology: From Macro- to Nanoscale Structures", Minsk, Belarus, Sept. 16-20, 2013 Y1 - 2013 SN - 978-985-553-135-8 SP - 165 EP - 167 PB - Verl. d. Weißruss. Staatl. Univ. CY - Minsk ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Flight style optimization in ski jumping on normal, large, and ski flying hills JF - Journal of biomechanics Y1 - 2013 SN - 1873-2380 (E-Journal); 0021-9290 (Print) N1 - Corrigendum to “Flight style optimization in ski jumping on normal, large, and ski flying hills” [J. Biomech 47 (2014) 716-722] Journal of Biomechanics, 2018;71:313. VL - Vol. 47 IS - Iss. 3 SP - 716 EP - 722 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Anding, Ralf A1 - Tabaza, Ruth A1 - Staat, Manfred A1 - Trenz, Eva A1 - Lohmann, Philipp A1 - Klinge, Uwe A1 - Kirschner-Hermanns, Ruth T1 - Introducing a method of in vitro testing of different anchoring systems used for female incontinence and prolapse surgery JF - BioMed research international Y1 - 2013 SN - 1110-7251 (E-Journal); 2314-6141 (E-Journal); 1110-7243 (Print); 2314-6133 (Print) VL - Vol. 2013 SP - Article ID 401417 ER - TY - CHAP A1 - Frotscher, Ralf A1 - Koch, Jan-Peter A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred ED - Onate, E. T1 - Evaluation of a computational model for drug action on cardiac tissue T2 - 11th World Congress on Computational Mechanics (WCCM XI) ; 5th European Conference on Computational Mechanics (ECCM V) ; 6th European Conference on Computational Fluid Dynamics (ECFD VI) ; July 20 - 25, 2014, Barcelona Y1 - 2014 SP - 1 EP - 12 ER - TY - CHAP A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram ED - Onate, E. T1 - Optimization of the flight style in ski jumping T2 - 11th World Congress on Computational Mechanics (WCCM XI) ; 5th European Conference on Computational Mechanics (ECCM V) ; 6th European Conference on Computational Fluid Dynamics (ECFD VI) ; July 20 - 25, 2014, Barcelona Y1 - 2014 N1 - Das Paper wurde nach der Konferenz überarbeitet. SP - 799 EP - 810 ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Frotscher, Ralf A1 - Sora, M.-C. A1 - Staat, Manfred ED - Onate, E. T1 - A 3D finite element model of the female pelvic floor for the reconstruction of urinary incontinence T2 - 11th World Congress on Computational Mechanics (WCCM XI) ; 5th European Conference on Computational Mechanics (ECCM V) ; 6th European Conference on Computational Fluid Dynamics (ECFD VI) ; July 20-25, 2014, Barcelona Y1 - 2014 SP - 1 EP - 12 ER - TY - CHAP A1 - Tran, Thanh Ngoc A1 - Staat, Manfred ED - Onate, E. T1 - Uncertain multimode failure and limit analysis of shells T2 - 11th World Congress on Computational Mechanics (WCCM XI) ; 5th European Conference on Computational Mechanics (ECCM V) ; 6th European Conference on Computational Fluid Dynamics (ECFD VI) ; July 20-25, 2014, Barcelona Y1 - 2014 SP - 1 EP - 12 ER - TY - CHAP A1 - Duong, Minh Tuan A1 - Staat, Manfred ED - Onate, E. T1 - A face-based smoothed finite element method for hyperelastic models and tissue growth T2 - 11th World Congress on Computational Mechanics (WCCM XI) ; 5th European Conference on Computational Mechanics (ECCM V) ; 6th European Conference on Computational Fluid Dynamics (ECFD VI) ; July 20-25, 2014, Barcelona Y1 - 2014 SP - 1 EP - 12 ER - TY - CHAP A1 - Tran, Ngoc Trinh A1 - Staat, Manfred A1 - Stavroulakis, G. E. ED - Onate, E. T1 - A multicriteria method for truss optimization T2 - 11th World Congress on Computational Mechanics (WCCM XI) ; 5th European Conference on Computational Mechanics (ECCM V) ; 6th European Conference on Computational Fluid Dynamics (ECFD VI) ; July 20-25, 2014, Barcelona Y1 - 2014 SP - 1 EP - 12 ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - FEM-based shakedown analysis of hardening structures JF - Asia Pacific journal on computational engineering N2 - This paper develops a new finite element method (FEM)-based upper bound algorithm for limit and shakedown analysis of hardening structures by a direct plasticity method. The hardening model is a simple two-surface model of plasticity with a fixed bounding surface. The initial yield surface can translate inside the bounding surface, and it is bounded by one of the two equivalent conditions: (1) it always stays inside the bounding surface or (2) its centre cannot move outside the back-stress surface. The algorithm gives an effective tool to analyze the problems with a very high number of degree of freedom. Our numerical results are very close to the analytical solutions and numerical solutions in literature. Y1 - 2014 U6 - http://dx.doi.org/10.1186/2196-1166-1-4 SN - 2196-1166 (E-Journal) IS - 1 SP - Article No. 4 PB - SpringerOpen CY - Berlin ER - TY - JOUR A1 - Ciobanu, Octavian A1 - Staat, Manfred A1 - Rahimi, Alireza T1 - The use of open source software in biomechanical finite element analysis JF - Buletinul Institutului Politehnic din Iaşi / Universitatea Tehnică Gh. Asachi, Iaşi Secţia 5, Construcţii de maşini = Machine construction = Bulletin of the Polytechnic Institute of Jassy = Izvestija Jasskogo Politechničeskogo Instituta Y1 - 2008 SN - 1011-2855 VL - 54 IS - 7/8 SP - 213 EP - 220 ER - TY - JOUR A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - Stresses produced by different textile mesh implants in a tissue equivalent JF - BioNanoMaterials N2 - Two single-incision mini-slings used for treating urinary incontinence in women are compared with respect to the stresses they produce in their surrounding tissue. In an earlier paper we experimentally observed that these implants produce considerably different stress distributions in a muscle tissue equivalent. Here we perform 2D finite element analyses to compare the shear stresses and normal stresses in the tissue equivalent for the two meshes and to investigate their failure behavior. The results clearly show that the Gynecare TVT fails for increasing loads in a zipper-like manner because it gradually debonds from the surrounding tissue. Contrary to that, the tissue at the ends of the DynaMesh-SIS direct may rupture but only at higher loads. The simulation results are in good agreement with the experimental observations thus the computational model helps to interpret the experimental results and provides a tool for qualitative evaluation of mesh implants. Y1 - 2014 U6 - http://dx.doi.org/10.1515/bnm-2014-0003 SN - 2191-4672 (E-Journal); 2193-066X (E-Journal); 0011-8656 (Print); 1616-0177 (Print); 2193-0651 (Print) VL - 15 IS - 1-2 SP - 25 EP - 30 PB - De Gruyter CY - Berlin ER - TY - CHAP A1 - Knott, Thomas C. A1 - Sofronia, Raluca E. A1 - Gerressen, Marcus A1 - Law, Yuen A1 - Davidescu, Arjana A1 - Savii, George G. A1 - Gatzweiler, Karl-Heinz A1 - Staat, Manfred A1 - Kuhlen, Torsten W. T1 - Preliminary bone sawing model for a virtual reality-based training simulator of bilateral sagittal split osteotomy T2 - Biomedical simulation : 6th International Symposium, ISBMS 2014, Strasbourg, France, October 16-17, 2014 : proceedings (Lecture notes in computer science : vol. 8789) N2 - Successful bone sawing requires a high level of skill and experience, which could be gained by the use of Virtual Reality-based simulators. A key aspect of these medical simulators is realistic force feedback. The aim of this paper is to model the bone sawing process in order to develop a valid training simulator for the bilateral sagittal split osteotomy, the most often applied corrective surgery in case of a malposition of the mandible. Bone samples from a human cadaveric mandible were tested using a designed experimental system. Image processing and statistical analysis were used for the selection of four models for the bone sawing process. The results revealed a polynomial dependency between the material removal rate and the applied force. Differences between the three segments of the osteotomy line and between the cortical and cancellous bone were highlighted. KW - Bone sawing KW - virtual reality KW - training simulator Y1 - 2014 SN - 978-3-319-12057-7 (Online) SN - 978-3-319-12056-0 (Print) U6 - http://dx.doi.org/10.1007/978-3-319-12057-7_1 SP - 1 EP - 10 PB - Springer CY - Cham ER - TY - CHAP A1 - Frotscher, Ralf A1 - Goßmann, Matthias A1 - Raatschen, Hans-Jürgen A1 - Temiz Artmann, Aysegül A1 - Staat, Manfred T1 - Simulation of cardiac cell-seeded membranes using the edge-based smoothed FEM T2 - Shell and membrane theories in mechanics and biology. (Advanced structured materials ; 45) N2 - We present an electromechanically coupled Finite Element model for cardiac tissue. It bases on the mechanical model for cardiac tissue of Hunter et al. that we couple to the McAllister-Noble-Tsien electrophysiological model of purkinje fibre cells. The corresponding system of ordinary differential equations is implemented on the level of the constitutive equations in a geometrically and physically nonlinear version of the so-called edge-based smoothed FEM for plates. Mechanical material parameters are determined from our own pressure-deflection experimental setup. The main purpose of the model is to further examine the experimental results not only on mechanical but also on electrophysiological level down to ion channel gates. Moreover, we present first drug treatment simulations and validate the model with respect to the experiments. Y1 - 2015 SN - 978-3-319-02534-6 ; 978-3-319-02535-3 SP - 187 EP - 212 PB - Springer CY - Heidelberg ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael T1 - The restricted influence of kinematic hardening on shakedown loads N2 - Structural design analyses are conducted with the aim of verifying the exclusion of ratcheting. To this end it is important to make a clear distinction between the shakedown range and the ratcheting range. In cyclic plasticity more sophisticated hardening models have been suggested in order to model the strain evolution observed in ratcheting experiments. The hardening models used in shakedown analysis are comparatively simple. It is shown that shakedown analysis can make quite stable predictions of admissible load ranges despite the simplicity of the underlying hardening models. A linear and a nonlinear kinematic hardening model of two-surface plasticity are compared in material shakedown analysis. Both give identical or similar shakedown ranges. Structural shakedown analyses show that the loading may have a more pronounced effect than the hardening model. KW - Biomedizinische Technik KW - Einspielen KW - Shakedown KW - Ratcheting KW - Bruchmechanik KW - shakedown KW - material shakedown KW - linear kinematic hardening KW - nonlinear kinematic hardening KW - ratchetting Y1 - 2002 ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael T1 - Direct static FEM approach to limit and shakedown analysis N2 - Safety and reliability of structures may be assessed indirectly by stress distributions. Limit and shakedown theorems are simplified but exact methods of plasticity that provide safety factors directly in the loading space. These theorems may be used for a direct definition of the limit state function for failure by plastic collapse or by inadaptation. In a FEM formulation the limit state function is obtained from a nonlinear optimization problem. This direct approach reduces considerably the necessary knowledge of uncertain technological input data, the computing time, and the numerical error. Moreover, the direct way leads to highly effective and precise reliability analyses. The theorems are implemented into a general purpose FEM program in a way capable of large-scale analysis. KW - Einspielen KW - Nichtlineare Optimierung KW - Shakedown KW - Shakedown KW - limit load KW - lower bound theorem KW - nonlinear optimization KW - reliability Y1 - 2000 ER - TY - JOUR A1 - Staat, Manfred T1 - Plastic collapse analysis of longitudinally flawed pipes and vessels N2 - Improved collapse loads of thick-walled, crack containing pipes and vessels are suggested. Very deep cracks have a residual strength which is better modelled by a global limit load. In all burst tests, the ductility of pressure vessel steels was sufficiently high whereby the burst pressure could be predicted by limit analysis with no need to apply fracture mechanics. The relative prognosis error increases however, for long and deep defects due to uncertainties of geometry and strength data. KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohr KW - Rohrbruch KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohrbruch KW - Fehlerstellen KW - pipes KW - vessels KW - load limit KW - burst tests KW - burst pressure KW - flaw Y1 - 2004 ER - TY - JOUR A1 - Staat, Manfred T1 - Cyclic plastic deformation tests to verify FEM-based shakedown analyses N2 - Fatigue analyses are conducted with the aim of verifying that thermal ratcheting is limited. To this end it is important to make a clear distintion between the shakedown range and the ratcheting range (continuing deformation). As part of an EU-supported research project, experiments were carried out using a 4-bar model. The experiment comprised a water-cooled internal tube, and three insulated heatable outer test bars. The system was subjected to alternating axial forces, superimposed with alternating temperatures at the outer bars. The test parameters were partly selected on the basis of previous shakedown analyses. During the test, temperatures and strains were measured as a function of time. The loads and the resulting stresses were confirmed on an ongoing basis during performance of the test, and after it. Different material models were applied for this incremental elasto-plastic analysis using the ANSYS program. The results of the simulation are used to verify the FEM-based shakedown analysis. KW - Materialermüdung KW - Einspielen KW - Materialermüdung KW - shakedown analyses KW - thermal ratcheting KW - fatigue analyses Y1 - 2001 ER - TY - JOUR A1 - Staat, Manfred T1 - Local and global collapse pressure of longitudinally flawed pipes and cylindrical vessels N2 - Limit loads can be calculated with the finite element method (FEM) for any component, defect geometry, and loading. FEM suggests that published long crack limit formulae for axial defects under-estimate the burst pressure for internal surface defects in thick pipes while limit loads are not conservative for deep cracks and for pressure loaded crack-faces. Very deep cracks have a residual strength, which is modelled by a global collapse load. These observations are combined to derive new analytical local and global collapse loads. The global collapse loads are close to FEM limit analyses for all crack dimensions. KW - Finite-Elemente-Methode KW - Grenzwertberechnung KW - Axialbelastung KW - FEM KW - Grenzwertberechnung KW - Axialbelastung KW - Traglastanalyse KW - Limit analysis KW - Global and local collapse KW - Axially cracked pipe KW - Pressure loaded crack-face Y1 - 2005 ER - TY - JOUR A1 - Staat, Manfred T1 - Direct finite element route for design-by-analysis of pressure components N2 - In the new European standard for unfired pressure vessels, EN 13445-3, there are two approaches for carrying out a Design-by-Analysis that cover both the stress categorization method (Annex C) and the direct route method (Annex B) for a check against global plastic deformation and against progressive plastic deformation. This paper presents the direct route in the language of limit and shakedown analysis. This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for mechanical and thermal actions. One observation from the examples is that the so-called 3f (3Sm) criterion fails to be a reliable check against progressive plastic deformation. Precise conditions are given, which greatly restrict the applicability of the 3f criterion. KW - Einspielen KW - Plastizität KW - Deformation KW - Analytischer Zulaessigkeitsnachweis KW - Einspiel-Analyse KW - fortschreitende plastische Deformation KW - alternierend Verformbarkeit KW - Einspiel-Kriterium KW - Design-by-analysis KW - Shakedown analysis KW - Progressive plastic deformation KW - Alternating plasticity KW - Shakedown criterion Y1 - 2005 ER - TY - JOUR A1 - Staat, Manfred T1 - Shakedown and ratchetting under tension-torsion loadings: analysis and experiments N2 - Structural design analyses are conducted with the aim of verifying the exclusion of ratchetting. To this end it is important to make a clear distinction between the shakedown range and the ratchetting range. The performed experiment comprised a hollow tension specimen which was subjected to alternating axial forces, superimposed with constant moments. First, a series of uniaxial tests has been carried out in order to calibrate a bounded kinematic hardening rule. The load parameters have been selected on the basis of previous shakedown analyses with the PERMAS code using a kinematic hardening material model. It is shown that this shakedown analysis gives reasonable agreement between the experimental and the numerical results. A linear and a nonlinear kinematic hardening model of two-surface plasticity are compared in material shakedown analysis. KW - Einspielen KW - Einspielen KW - Ratchetting KW - Zug-Druck Belastung KW - shakedown KW - ratchetting KW - tension–torsion loading Y1 - 2003 ER - TY - JOUR A1 - Staat, Manfred T1 - Basis Reduction for the Shakedown Problem for Bounded Kinematic Hardening Material N2 - Limit and shakedown analysis are effective methods for assessing the load carrying capacity of a given structure. The elasto–plastic behavior of the structure subjected to loads varying in a given load domain is characterized by the shakedown load factor, defined as the maximum factor which satisfies the sufficient conditions stated in the corresponding static shakedown theorem. The finite element dicretization of the problem may lead to very large convex optimization. For the effective solution a basis reduction method has been developed that makes use of the special problem structure for perfectly plastic material. The paper proposes a modified basis reduction method for direct application to the two-surface plasticity model of bounded kinematic hardening material. The considered numerical examples show an enlargement of the load carrying capacity due to bounded hardening. KW - Finite-Elemente-Methode KW - Einspielen KW - Basis Reduktion KW - konvexe Optimierung KW - FEM KW - Druckgeräte KW - Basis reduction KW - Convex optimization KW - FEM KW - Shakedown analysis Y1 - 2000 ER - TY - CHAP A1 - Staat, Manfred T1 - Design by Analysis of Pressure Components by non-linear Optimization N2 - This paper presents the direct route to Design by Analysis (DBA) of the new European pressure vessel standard in the language of limit and shakedown analysis (LISA). This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for some examples from the DBA-Manual. One observation from the examples is, that the optimisation approach gives reliable and close lower bound solutions leading to simple and optimised design decision. KW - Analytischer Zulaessigkeitsnachweis KW - FEM KW - Einspiel-Analyse KW - design-by-analysis KW - finite element analysis KW - limit and shakedown analysis Y1 - 2003 ER - TY - JOUR A1 - Staat, Manfred T1 - LISA - a European project for FEM-based limit and shakedown analysis N2 - The load-carrying capacity or the safety against plastic limit states are the central questions in the design of structures and passive components in the apparatus engineering. A precise answer is most simply given by limit and shakedown analysis. These methods can be based on static and kinematic theorems for lower and upper bound analysis. Both may be formulated as optimization problems for finite element discretizations of structures. The problems of large-scale analysis and the extension towards realistic material modelling will be solved in a European research project. Limit and shakedown analyses are briefly demonstrated with illustrative examples. KW - Einspielen KW - Traglast KW - Finite-Elemente-Methode KW - Traglastanalyse KW - Einspielanalyse KW - FEM KW - limit analysis KW - shakedown analysis Y1 - 2001 ER - TY - JOUR A1 - Staat, Manfred T1 - Direct FEM Limit and Shakedown Analysis with Uncertain Data N2 - The structural reliability with respect to plastic collapse or to inadaptation is formulated on the basis of the lower bound limit and shakedown theorems. A direct definition of the limit state function is achieved which permits the use of the highly effective first order reliability methods (FORM) is achieved. The theorems are implemented into a general purpose FEM program in a way capable of large-scale analysis. The limit state function and its gradient are obtained from a mathematical optimization problem. This direct approach reduces considerably the necessary knowledge of uncertain technological input data, the computing time, and the numerical error, leading to highly effective and precise reliability analyses. KW - Finite-Elemente-Methode KW - Einspielen KW - FEM KW - Einspielanalyse KW - shakedown KW - limit load KW - reliability analysis KW - FEM KW - direct method Y1 - 2000 ER - TY - JOUR A1 - Vu, Duc-Khoi A1 - Staat, Manfred T1 - An algorithm for shakedown analysis of structure with temperature dependent yield stress N2 - This work is an attempt to answer the question: How to use convex programming in shakedown analysis of structures made of materials with temperature-dependent properties. Based on recently established shakedown theorems and formulations, a dual relationship between upper and lower bounds of the shakedown limit load is found, an algorithmfor shakedown analysis is proposed. While the original problem is neither convex nor concave, the algorithm presented here has the advantage of employing convex programming tools. KW - Einspielen KW - Temperaturabhängigkeit KW - Fließgrenze KW - Shakedown KW - shakedown analysis KW - yield stress Y1 - 2004 ER - TY - JOUR A1 - Kühn, Raoul-Roman A1 - Haugner, Werner A1 - Staat, Manfred A1 - Sponagel, Stefan T1 - A Two Phase Mixture Model based on Bone Observation N2 - An optimization method is developed to describe the mechanical behaviour of the human cancellous bone. The method is based on a mixture theory. A careful observation of the behaviour of the bone material leads to the hypothesis that the bone density is controlled by the principal stress trajectories (Wolff’s law). The basic idea of the developed method is the coupling of a scalar value via an eigenvalue problem to the principal stress trajectories. On the one hand this theory will permit a prediction of the reaction of the biological bone structure after the implantation of a prosthesis, on the other hand it may be useful in engineering optimization problems. An analytical example shows its efficiency. KW - Knochen KW - Knochenbildung KW - Knochenchirugie KW - Strukturanalyse KW - Schwammknochen KW - Knochendichte KW - Wolffsches Gesetz KW - bone structure KW - bone density KW - Wolff's Law KW - cancellous bone Y1 - 2004 ER - TY - CHAP A1 - Staat, Manfred A1 - Ballmann, J. T1 - Fundamental aspects of numerical methods for the propagation of multi-dimensional nonlinear waves in solids T2 - Nonlinear hyperbolic equations : theory, computations methods, and applications ; proceedings of the 2nd International Conference on Nonlinear Hyperbolic Problems, Aachen N2 - The nonlinear scalar constitutive equations of gases lead to a change in sound speed from point to point as would be found in linear inhomogeneous (and time dependent) media. The nonlinear tensor constitutive equations of solids introduce the additional local effect of solution dependent anisotropy. The speed of a wave passing through a point changes with propagation direction and its rays are inclined to the front. It is an open question whether the widely used operator splitting techniques achieve a dimensional splitting with physically reasonable results for these multi-dimensional problems. May be this is the main reason why the theoretical and numerical investigations of multi-dimensional wave propagation in nonlinear solids are so far behind gas dynamics. We hope to promote the subject a little by a discussion of some fundamental aspects of the solution of the equations of nonlinear elastodynamics. We use methods of characteristics because they only integrate mathematically exact equations which have a direct physical interpretation. KW - Nichtlineare Welle KW - Nichtlineare Gleichung KW - Festkörper KW - Elastodynamik KW - Multi-dimensional wave propagation KW - nonlinear solids KW - nonlinear tensor constitutive equation Y1 - 1989 SP - 574 EP - 588 ER - TY - GEN A1 - Staat, Manfred T1 - Technische Mechanik. Vorlesungsmitschrift. Korrigierter Nachdr. der 3. Aufl. N2 - Überarbeitete, korrigierte und ergänzte Version einer Vorlesungsmitschrift von Sebastian Krämer. 172 S. Inhaltsverzeichnis 0 Einführung in die Mechanik 1 Statik starrer Körper 2 Elastostatik (Festigkeitslehre) 3 Kinematik 4 Kinetik Literatur KW - Technische Mechanik Y1 - 2006 ER - TY - GEN A1 - Staat, Manfred T1 - Engineering Mechanics. Lecture Notes. 2nd edition, translation of the 3rd corrected and extended German edition of "Technische Mechanik" N2 - English translation of the corrected lectures notes of Sebastian Krämer. Contents 0 Introduction to Mechanics 1 Statics of Rigid Bodies 2 Elastostatics (Strength of Materials) 3 Kinematics 4 Kinetics Literature KW - Technische Mechanik KW - Mechanics KW - Statics KW - Elastostatics KW - Kinematics KW - Kinetics Y1 - 2006 ER - TY - GEN A1 - Staat, Manfred A1 - Barry, Steve T1 - Continuum Mechanics with an Introduction to the Finite Element Method / Steve Barry; Manfred Staat. With extensions by Manfred Staat. N2 - Contents: 1 Introduction 2 One Dimensional Continuum Mechanics 3 Tensors 4 Three Dimensional Stress and Strain 5 Conservation Laws 6 Contiunuum Modelling 7 Plain Problems 8 Questions 9 Reference Information KW - Technische Mechanik KW - Finite-Elemente-Methode Y1 - 2006 ER - TY - CHAP A1 - Tran, Thanh Ngoc A1 - Staat, Manfred A1 - Kreißig, R. T1 - Calculation of load carrying capacity of shell structures with elasto-plastic material by direct methods N2 - Proceedings of the International Conference on Material Theory and Nonlinear Dynamics. MatDyn. Hanoi, Vietnam, Sept. 24-26, 2007, 8 p. In this paper, a method is introduced to determine the limit load of general shells using the finite element method. The method is based on an upper bound limit and shakedown analysis with elastic-perfectly plastic material model. A non-linear constrained optimisation problem is solved by using Newton’s method in conjunction with a penalty method and the Lagrangean dual method. Numerical investigation of a pipe bend subjected to bending moments proves the effectiveness of the algorithm. KW - Finite-Elemente-Methode Y1 - 2007 ER - TY - CHAP A1 - Tran, Thanh Ngoc A1 - Staat, Manfred A1 - Kreißig, R. T1 - Finite element shakedown and limit reliability analysis of thin shells N2 - A procedure for the evaluation of the failure probability of elastic-plastic thin shell structures is presented. The procedure involves a deterministic limit and shakedown analysis for each probabilistic iteration which is based on the kinematical approach and the use the exact Ilyushin yield surface. Based on a direct definition of the limit state function, the non-linear problems may be efficiently solved by using the First and Second Order Reliabiblity Methods (Form/SORM). This direct approach reduces considerably the necessary knowledge of uncertain technological input data, computing costs and the numerical error. In: Computational plasticity / ed. by Eugenio Onate. Dordrecht: Springer 2007. VII, 265 S. (Computational Methods in Applied Sciences ; 7) (COMPLAS IX. Part 1 . International Center for Numerical Methods in Engineering (CIMNE)). ISBN 978-1-402-06576-7 S. 186-189 KW - Finite-Elemente-Methode KW - Limit analysis KW - shakedown analysis KW - Exact Ilyushin yield surface KW - Random variable KW - First Order Reliabiblity Method Y1 - 2007 ER - TY - CHAP A1 - Staat, Manfred T1 - Problems and chances for probabilistic fracture mechanics in the analysis of steel pressure boundary reliability. - Überarb. Ausg. N2 - In: Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994. - Vienna , 1996. - Seite: 43 - 55 IAEA-TECDOC-920 Abstract: It is shown that the difficulty for probabilistic fracture mechanics (PFM) is the general problem of the high reliability of a small population. There is no way around the problem as yet. Therefore what PFM can contribute to the reliability of steel pressure boundaries is demon­strated with the example of a typical reactor pressure vessel and critically discussed. Although no method is distinguishable that could give exact failure probabilities, PFM has several addi­tional chances. Upper limits for failure probability may be obtained together with trends for design and operating conditions. Further, PFM can identify the most sensitive parameters, improved control of which would increase reliability. Thus PFM should play a vital role in the analysis of steel pressure boundaries despite all shortcomings. KW - Bruchmechanik KW - probabilistic fracture mechanics KW - PFM Y1 - 2006 ER - TY - CHAP A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - Uncertainty multimode failure and shakedown analysis of shells T2 - Direct methods for limit and shakedown analysis of structures / eds. Paolo Fuschi ... N2 - This paper presents a numerical procedure for reliability analysis of thin plates and shells with respect to plastic collapse or to inadaptation. The procedure involves a deterministic shakedown analysis for each probabilistic iteration, which is based on the upper bound approach and the use of the exact Ilyushin yield surface. Probabilistic shakedown analysis deals with uncertainties originated from the loads, material strength and thickness of the shell. Based on a direct definition of the limit state function, the calculation of the failure probability may be efficiently solved by using the First and Second Order Reliability Methods (FORM and SORM). The problem of reliability of structural systems (series systems) is handled by the application of a special technique which permits to find all the design points corresponding to all the failure modes. Studies show, in this case, that it improves considerably the FORM and SORM results. KW - Limit analysis KW - Shakedown analysis KW - Reliability analysis KW - Multimode failure KW - Non-linear optimization Y1 - 2015 SN - 978-3-319-12927-3 (print) ; 978-3-319-12928-0 (online) U6 - http://dx.doi.org/10.1007/978-3-319-12928-0_14 SP - 279 EP - 298 PB - Springer CY - Cham ER - TY - JOUR A1 - Frotscher, Ralf A1 - Koch, Jan-Peter A1 - Staat, Manfred T1 - Computational investigation of drug action on human-induced stem cell derived cardiomyocytes JF - Journal of biomechanical engineering Y1 - 2015 U6 - http://dx.doi.org/10.1115/1.4030173 SN - 1528-8951 (E-Journal); 0148-0731 (Print) VL - Vol. 137 IS - iss. 7 SP - 071002-1 EP - 071002-7 PB - ASME CY - New York ER - TY - JOUR A1 - Duong, Minh Tuan A1 - Nguyen, Nhu Huynh A1 - Tran, Thanh Ngoc A1 - Tolba, R. H. A1 - Staat, Manfred T1 - Influence of refrigerated storage on tensile mechanical properties of porcine liver and spleen JF - International biomechanics Y1 - 2015 U6 - http://dx.doi.org/10.1080/23335432.2015.1049295 SN - 2333-5432 VL - Vol. 2 IS - Iss. 1 SP - 79 EP - 88 PB - Taylor & Francis CY - London ER - TY - CHAP A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - An electromechanical model for cardiac tissue constructs T2 - Conference proceedings of the YIC GACM 2015 : 3rd ECCOMAS Young Investigators Conference and 6th GACM Colloquium on Computational Mechanics , Aachen, 20.07.2015 - 23.07.2015 / ed.: Stefanie Elgeti ; Jaan-Willem Simon Y1 - 2015 SP - 1 EP - 4 PB - RWTH Aachen University CY - Aachen ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - Biomechanical study of the female pelvic floor dysfunction using the finite element method T2 - Conference proceedings of the YIC GACM 2015 : 3rd ECCOMAS Young Investigators Conference and 6th GACM Colloquium on Computational Mechanics , Aachen , Germany, 20.07.2015 - 23.07.2015 / ed.: Stefanie Elgeti ; Jaan-Willem Simon Y1 - 2015 SP - 1 EP - 4 PB - RWTH Aachen University CY - Aachen ER - TY - CHAP A1 - Duong, Minh Tuan A1 - Nguyen, N. H. A1 - Staat, Manfred T1 - Modeling and simulation of a growing mass by the Smoothed Finite Element Method (SFEM) T2 - Conference proceedings of the YIC GACM 2015 : 3rd ECCOMAS Young Investigators Conference and 6th GACM Colloquium on Computational Mechanics , Aachen, Germany, 20.07.2015 - 23.07.2015 / ed.: Stefanie Elgeti ; Jaan-Willem Simon Y1 - 2015 SP - 1 EP - 4 PB - RWTH Aachen University CY - Aachen ER - TY - CHAP A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - A simplification for shakedown analysis of hardening structures T2 - Conference proceedings of the YIC GACM 2015 : 3rd ECCOMAS Young Investigators Conference and 6th GACM Colloquium on Computational Mechanics , Aachen , Germany, 20.07.2015 - 23.07.2015 / ed.: Stefanie Elgeti ; Jaan-Willem Simon Y1 - 2015 SP - 1 EP - 4 PB - RWTH Aachen University CY - Aachen ER - TY - CHAP A1 - Frotscher, Ralf A1 - Staat, Manfred ED - Nithiarasu, Perumal T1 - Homogenization of a cardiac tissue construct T2 - CMBE15 : 4th International Conference on Computational & Mathematical Biomedical Engineering ; 29th June - 1st July 2015 ; École Normale Supérieure de Cachan ; Cachan (Paris), France Y1 - 2015 SN - 2227-9385 N1 - Konferenzband unter: http://www.compbiomed.net/getfile.php?type=12/site_documents&id=Proceedings_2227-9385_compressed.pdf SP - 645 EP - 648 PB - CMBE CY - [s.l.] ER - TY - CHAP A1 - Frotscher, Ralf A1 - Duong, Minh Tuan A1 - Staat, Manfred T1 - Simulating beating cardiomyocytes with electromechanical coupling T2 - II. International Conference on Biomedical Technology : 28-30 October 2015 Hannover, Germany / T. Lenarz, P. Wriggers (Eds.) Y1 - 2015 SP - 1 EP - 2 ER - TY - JOUR A1 - Duong, Minh Tuan A1 - Nguyen, Nhu Huynh A1 - Staat, Manfred T1 - Physical response of hyperelastic models for composite materials and soft tissues JF - Asia pacific journal on computational engineering Y1 - 2015 U6 - http://dx.doi.org/10.1186/s40540-015-0015-x SN - 2196-1166 VL - 2 IS - 3 (December 2015) SP - 1 EP - 18 ER - TY - CHAP A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Effect of wind on flight style optimisation in ski jumping T2 - 15th International Symposium on Computer Simulation in Biomechanics ; July 9th-11th 2015, Edinburgh, UK Y1 - 2016 SP - 53 EP - 54 PB - The University of Edinburgh ; Loughborough University CY - Edinburgh ER - TY - JOUR A1 - Goßmann, Matthias A1 - Frotscher, Ralf A1 - Linder, Peter A1 - Bayer, Robin A1 - Epple, U. A1 - Staat, Manfred A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard T1 - Mechano-pharmacological characterization of cardiomyocytes derived from human induced pluripotent stem cells JF - Cellular physiology and biochemistry N2 - Background/Aims: Common systems for the quantification of cellular contraction rely on animal-based models, complex experimental setups or indirect approaches. The herein presented CellDrum technology for testing mechanical tension of cellular monolayers and thin tissue constructs has the potential to scale-up mechanical testing towards medium-throughput analyses. Using hiPS-Cardiac Myocytes (hiPS-CMs) it represents a new perspective of drug testing and brings us closer to personalized drug medication. Methods: In the present study, monolayers of self-beating hiPS-CMs were grown on ultra-thin circular silicone membranes and deflect under the weight of the culture medium. Rhythmic contractions of the hiPS-CMs induced variations of the membrane deflection. The recorded contraction-relaxation-cycles were analyzed with respect to their amplitudes, durations, time integrals and frequencies. Besides unstimulated force and tensile stress, we investigated the effects of agonists and antagonists acting on Ca²⁺ channels (S-Bay K8644/verapamil) and Na⁺ channels (veratridine/lidocaine). Results: The measured data and simulations for pharmacologically unstimulated contraction resembled findings in native human heart tissue, while the pharmacological dose-response curves were highly accurate and consistent with reference data. Conclusion: We conclude that the combination of the CellDrum with hiPS-CMs offers a fast, facile and precise system for pharmacological, toxicological studies and offers new preclinical basic research potential. KW - Inotropic compounds KW - Pharmacology KW - Ion channels KW - CellDrum KW - Heart tissue culture KW - Induced pluripotent stem cells KW - Cardiac myocytes Y1 - 2016 U6 - http://dx.doi.org/10.1159/000443124 SN - 1421-9778 (Online) SN - 1015-8987 (Print) VL - 38 IS - 3 SP - 1182 EP - 1198 PB - Karger CY - Basel ER - TY - JOUR A1 - Frotscher, Ralf A1 - Muanghong, Danita A1 - Dursun, Gözde A1 - Goßmann, Matthias A1 - Temiz Artmann, Aysegül A1 - Staat, Manfred T1 - Sample-specific adaption of an improved electro-mechanical model of in vitro cardiac tissue JF - Journal of Biomechanics N2 - We present an electromechanically coupled computational model for the investigation of a thin cardiac tissue construct consisting of human-induced pluripotent stem cell-derived atrial, ventricular and sinoatrial cardiomyocytes. The mechanical and electrophysiological parts of the finite element model, as well as their coupling are explained in detail. The model is implemented in the open source finite element code Code_Aster and is employed for the simulation of a thin circular membrane deflected by a monolayer of autonomously beating, circular, thin cardiac tissue. Two cardio-active drugs, S-Bay K8644 and veratridine, are applied in experiments and simulations and are investigated with respect to their chronotropic effects on the tissue. These results demonstrate the potential of coupled micro- and macroscopic electromechanical models of cardiac tissue to be adapted to experimental results at the cellular level. Further model improvements are discussed taking into account experimentally measurable quantities that can easily be extracted from the obtained experimental results. The goal is to estimate the potential to adapt the presented model to sample specific cell cultures. KW - hiPS cardiomyocytes KW - Homogenization KW - Hodgkin–Huxley models KW - Frequency adaption KW - Electromechanical modeling KW - Drug simulation KW - Computational biomechanics KW - Cardiac tissue Y1 - 2016 U6 - http://dx.doi.org/10.1016/j.jbiomech.2016.01.039 SN - 0021-9290 (Print) SN - 1873-2380 (Online) VL - 49 IS - 12 SP - 2428 EP - 2435 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hackl, Michael A1 - Müller, Lars-Peter A1 - Staat, Manfred A1 - Kahmann, Stephanie Lucina A1 - Wegmann, Kilian T1 - Proximal phalangeal neck fractures of the hand — a biomechanical comparison of three fixation techniques JF - Knee surgery, sports traumatology, arthroscopy N2 - Plate osteosynthesis of displaced proximal phalangeal neck fractures of the hand allows early mobilization due to a stable internal fixation. Nevertheless, joint stiffness—because of soft tissue irritation—represents a common complication leading to high complication rates. Del Pinal et al. recently reported promising clinical results for a new, minimally invasive fixation technique with a cannulated headless intramedullary compression screw. Hence, the aim of this study was to compare plate fixation of proximal phalangeal neck fractures to less two less invasive techniques: Crossed k-wire fixation and intramedullary screw fixation. We hypothesized that these fixation techniques provide inferior stability when compared to plate osteosynthesis. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00167-016-4080-7 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 148 EP - 149 PB - Springer CY - Berlin ER - TY - JOUR A1 - Hackl, Michael A1 - Kahmann, Stephanie Lucina A1 - Wegmann, Kilian A1 - Ries, Christian A1 - Staat, Manfred A1 - Müller, Lars-Peter T1 - Shortening osteotomy of the proximal radius — a treatment option for isolated osteoarthritis of the lateral column of the elbow joint? JF - Knee surgery, sports traumatology, arthroscopy N2 - Treatment of posttraumatic osteoarthritis of the radial column of the elbow joint remains a challenging yet common issue. While partial joint replacement leads to high revision rates, radial head excision has shown to severely increase joint instability. Shortening osteotomy of the radius could be an option to decrease the contact pressure of the radiohumeral joint and thereby pain levels without causing valgus instability. Hence, the aim of this biomechanical study was to evaluate the effects of radial shortening on axial load distribution and valgus stability of the elbow joint. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00167-016-4080-7 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 128 EP - 129 PB - Springer CY - Berlin ER - TY - JOUR A1 - Hackl, Michael A1 - Leschinger, T. A1 - Staat, Manfred A1 - Müller, Lars-Peter A1 - Wegmann, Kilian T1 - Reconstruction of the interosseous membrane in the Essex Lopresti lesion — a biomechanical evaluation JF - Knee surgery, sports traumatology, arthroscopy N2 - Surgical reconstruction of the interosseous membrane (IOM) could restore longitudinal forearm stability to avoid persisting disability due to capituloradial and ulnocarpal impingement in Essex Lopresti lesions. This biomechanical study aimed to assess longitudinal forearm stability of intact specimens, after sectioning of the IOM and after reconstruction with a TightRope construct using either a single or double bundle technique. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00167-016-4080-7 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 130 EP - 131 PB - Springer CY - Berlin ER - TY - JOUR A1 - Wegmann, Kilian A1 - Hackl, Michael A1 - Staat, Manfred A1 - Mayer, Katharina A1 - Müller, Lars-Peter T1 - Double plate osteosynthesis of proximal ulna fractures: biomechanical and clinical results JF - Knee surgery, sports traumatology, arthroscopy N2 - While plate fixation of proximal ulna fractures might lead to superior clinical results compared to tension band wiring, regular plates represent an established risk factor for wound complications. The olecranon double plates (Medartis, Basel, CH) might decrease complications related to the osteosynthesis because of their low profile and better anatomical fit. This study aimed to evaluate the biomechanical performance and clinical results of the olecranon double plates. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00167-016-4079-0 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 58 EP - 59 PB - Springer CY - Berlin ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Staat, Manfred ED - Erni, Daniel T1 - Female pelvic floor dysfunction: progress weakening of the support system T2 - 1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen N2 - The structure of the female pelvic floor (PF) is an inter-related system of bony pelvis,muscles, pelvic organs, fascias, ligaments, and nerves with multiple functions. Mechanically, thepelvic organ support system are of two types: (I) supporting system of the levator ani (LA) muscle,and (II) the suspension system of the endopelvic fascia condensation [1], [2]. Significantdenervation injury to the pelvic musculature, depolimerization of the collagen fibrils of the softvaginal hammock, cervical ring and ligaments during pregnancy and vaginal delivery weakens thenormal functions of the pelvic floor. Pelvic organ prolapse, incontinence, sexual dysfunction aresome of the dysfunctions which increases progressively with age and menopause due toweakened support system according to the Integral theory [3]. An improved 3D finite elementmodel of the female pelvic floor as shown in Fig. 1 is constructed that: (I) considers the realisticsupport of the organs to the pelvic side walls, (II) employs the improvement of our previous FEmodel [4], [5] along with the patient based geometries, (III) incorporates the realistic anatomy andboundary conditions of the endopelvic (pubocervical and rectovaginal) fascia, and (IV) considersvarying stiffness of the endopelvic fascia in the craniocaudal direction [3]. Several computationsare carried out on the presented computational model with healthy and damaged supportingtissues, and comparisons are made to understand the physiopathology of the female PF disorders. Y1 - 2016 U6 - http://dx.doi.org/10.17185/duepublico/40821 SP - 11 EP - 12 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Jung, Alexander A1 - Staat, Manfred ED - Erni, Daniel T1 - Computing olympic gold: Ski jumping as an example T2 - 1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen Y1 - 2016 SN - 978-3-940402-06-6 U6 - http://dx.doi.org/10.17185/duepublico/40821 SP - 54 EP - 55 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Kahmann, Stephanie A1 - Hackl, Michael A1 - Wegmann, Kilian A1 - Müller, Lars-Peter A1 - Staat, Manfred ED - Erni, Daniel T1 - Impact of a proximal radial shortening osteotomy on the distribution of forces and the stability of the elbow T2 - 1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen N2 - The human arm consists of the humerus (upper arm), the medial ulna and the lateral radius (forearm). The joint between the humerus and the ulna is called humeroulnar joint and the joint between the humerus and the radius is called humeroradial joint. Lateral and medial collateral ligaments stabilize the elbow. Statistically, 2.5 out of 10,000 people suffer from radial head fractures [1]. In these fractures the cartilage is often affected. Caused by the injured cartilage, degenerative diseases like posttraumatic arthrosis may occur. The resulting pain and reduced range of motion have an impact on the patient’s quality of life. Until now, there has not been a treatment which allows typical loads in daily life activities and offers good long-term results. A new surgical approach was developed with the motivation to reduce the progress of the posttraumatic arthrosis. Here, the radius is shortened by 3 mm in the proximal part [2]. By this means, the load of the radius is intended to be reduced due to a load shift to the ulna. Since the radius is the most important stabilizer of the elbow it has to be confirmed that the stability is not affected. In the first test (Fig. 1 left), pressure distributions within the humeroulnar and humeroradial joints a native and a shortened radius were measured using resistive pressure sensors (I5076 and I5027, Tekscan, USA). The humerus was loaded axially in a tension testing machine (Z010, Zwick Roell, Germany) in 50 N steps up to 400 N. From the humerus the load is transmitted through both the radius and the ulna into the hand which is fixed on the ground. In the second test (Fig. 1 right), the joint stability was investigated using a digital image correlation system to measure the displacement of the ulna. Here, the humerus is fixed with a desired flexion angle and the unconstrained forearm lies on the ground. A rope connects the load actuator with a hook fixed in the ulna. A guide roller is used so that the rope pulls the ulna horizontally when a tensile load is applied. This creates a moment about the elbow joint with a maximum value of 7.5 Nm. Measurements were performed with varying flexion angles (0°, 30°, 60°, 90°, 120°). For both tests and each measurement, seven specimens were used. Student ́s t-test was employed to determine whether the mean values of the measurements in native specimen and operated specimens differ significantly. Y1 - 2016 U6 - http://dx.doi.org/10.17185/duepublico/40821 SP - 7 EP - 8 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Staat, Manfred A1 - Duong, Minh Tuan T1 - Smoothed Finite Element Methods for Nonlinear Solid Mechanics Problems: 2D and 3D Case Studies T2 - Proceedings of the National Science and Technology Conference on Mechanical - Transportation Engineering (NSCMET 2016), 13th October 2016, Hanoi, Vietnam, Vol.2 N2 - The Smoothed Finite Element Method (SFEM) is presented as an edge-based and a facebased techniques for 2D and 3D boundary value problems, respectively. SFEMs avoid shortcomings of the standard Finite Element Method (FEM) with lower order elements such as overly stiff behavior, poor stress solution, and locking effects. Based on the idea of averaging spatially the standard strain field of the FEM over so-called smoothing domains SFEM calculates the stiffness matrix for the same number of degrees of freedom (DOFs) as those of the FEM. However, the SFEMs significantly improve accuracy and convergence even for distorted meshes and/or nearly incompressible materials. Numerical results of the SFEMs for a cardiac tissue membrane (thin plate inflation) and an artery (tension of 3D tube) show clearly their advantageous properties in improving accuracy particularly for the distorted meshes and avoiding shear locking effects. Y1 - 2016 SP - 440 EP - 445 ER - TY - CHAP A1 - Tran, Ngoc Trinh A1 - Tran, Thanh Ngoc A1 - Matthies, Hermann G. A1 - Stavroulakis, Georgios Eleftherios A1 - Staat, Manfred T1 - FEM Shakedown of uncertain structures by chance constrained programming T2 - PAMM Proceedings in Applied Mathematics and Mechanics Y1 - 2016 U6 - http://dx.doi.org/10.1002/pamm.201610346 SN - 1617-7061 N1 - Special Issue: Joint 87th Annual Meeting of the International Association of Applied Mathematics and Mechanics (GAMM) and Deutsche Mathematiker-Vereinigung VL - 16 IS - 1 SP - 715 EP - 716 ER - TY - CHAP A1 - Duong, Minh Tuan A1 - Jung, Alexander A1 - Frotscher, Ralf A1 - Staat, Manfred ED - Papadrakakis, M. T1 - A 3D electromechanical FEM-based model for cardiac tissue T2 - ECCOMAS Congress 2016, VII European Congress on Computational Methods in Applied Sciences and Engineering. Crete Island, Greece, 5–10 June 2016 Y1 - 2016 N1 - revised after the conference P11367 ER - TY - CHAP A1 - Tran, Ngoc Trinh A1 - Tran, Thanh Ngoc A1 - Matthies, H. G. A1 - Stavroulakis, G. E. A1 - Staat, Manfred ED - Papadrakakis, M. T1 - Shakedown analysis of plate bending analysis under stochastic uncertainty by chance constrained programming T2 - ECCOMAS Congress 2016, VII European Congress on Computational Methods in Applied Sciences and Engineering. Crete Island, Greece, 5–10 June 2016 Y1 - 2016 ER - TY - JOUR A1 - Hackl, M. A1 - Andermahr, J. A1 - Staat, Manfred A1 - Bremer, I. A1 - Borggrefe, J. A1 - Prescher, A. A1 - Müller, L. P. A1 - Wegmann, K. T1 - Suture button reconstruction of the central band of the interosseous membrane in Essex-Lopresti lesions: a comparative biomechanical investigation JF - The Journal of Hand Surgery (European Volume) Y1 - 2017 U6 - http://dx.doi.org/10.1177/1753193416665943 SN - 2043-6289 (Online) SN - 1753-1934 (Print) VL - 42 IS - 4 SP - 370 EP - 376 PB - Sage CY - London ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Frotscher, Ralf A1 - Staat, Manfred ED - Natal Jorge, Renato T1 - Significance of fibre geometry on passive-active response of pelvic muscles to evaluate pelvic dysfunction T2 - BioMedWomen: Proceedings of the international conference on clinical and bioengineering for women's health Y1 - 2016 SN - 978-1-138-02910-1 SP - 185 EP - 188 PB - CRC Press CY - Boca Raton ER - TY - JOUR A1 - Staat, Manfred T1 - Limit and shakedown analysis under uncertainty JF - Tap chi Khoa hoc & ung dung - Dai hoc Ton Duc Thang Y1 - 2012 N1 - = Journal of Applied Sciences - Ton Duc Thang University VL - 19 SP - 45 EP - 47 ER - TY - JOUR A1 - Hackl, Michael A1 - Wegmann, Kilian A1 - Kahmann, Stephanie Lucina A1 - Heinze, Nicolai A1 - Staat, Manfred A1 - Neiss, Wolfram F. A1 - Scaal, Martin A1 - Müller, Lars P. T1 - Radial shortening osteotomy reduces radiocapitellar contact pressures while preserving valgus stability of the elbow JF - Knee Surgery, Sports Traumatology, Arthroscopy Y1 - 2017 U6 - http://dx.doi.org/10.1007/s00167-017-4468-z SN - 1433-7347 VL - 25 IS - 7 SP - 2280 EP - 2288 PB - Springer CY - Berlin ER - TY - JOUR A1 - Michael, Hackl A1 - Mayer, Katharina A1 - Weber, Mareike A1 - Staat, Manfred A1 - van Riet, Roger A1 - Burkhart, Klau Josef A1 - Müller, Lars Peter A1 - Wegmann, Kilian T1 - Plate osteosynthesis of proximal ulna fractures : a biomechanical micromotion analysis JF - The journal of hand surgery Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.jhsa.2017.05.014 SN - 0363-5023 VL - 42 IS - 10 SP - 834.e1 EP - 834.e7 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ciritsis, Alexander A1 - Horbach, Andreas A1 - Staat, Manfred A1 - Kuhl, Christiane K. A1 - Kraemer, Nils Andreas T1 - Porosity and tissue integration of elastic mesh implants evaluated in vitro and in vivo JF - Journal of Biomedical Materials Research: Part B: Applied Biomaterials N2 - Purpose In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model. Material and Methods Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio). Results In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4% for TPU and of 1.2% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF. Conclusion The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827–833, 2018. Y1 - 2018 U6 - http://dx.doi.org/10.1002/jbm.b.33877 SN - 1552-4981 VL - 106 IS - 2 SP - 827 EP - 833 PB - Wiley CY - New York, NY ER - TY - CHAP A1 - Abel, Alexander A1 - Pérez-Viana, Daniel A1 - Ciritsis, Bernard A1 - Staat, Manfred ED - Erni, Daniel ED - Fischerauer, Alice ED - Himmel, Jörg ED - Seeger, Thomas ED - Thelen, Klaus T1 - Prevention of femur neck fractures through femoroplasty T2 - 2nd YRA MedTech Symposium 2017 : June 8th - 9th / 2017 / Hochschule Ruhr-West Y1 - 2017 SN - 978-3-9814801-9-1 U6 - http://dx.doi.org/10.17185/duepublico/43984 N1 - A young researchers track of the 7th IEEE Workshop & SENSORICA 2017 SP - 114 EP - 115 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Birgel, Stefan A1 - Leschinger, Tim A1 - Wegmann, Kilian A1 - Staat, Manfred ED - Erni, Daniel ED - Fischerauer, Alice ED - Himmel, Jörg ED - Seeger, Thomas ED - Thelen, Klaus T1 - Calculation of muscle forces and joint reaction loads in shoulder area via an OpenSim based computer calculation T2 - 2nd YRA MedTech Symposium 2017 : June 8th - 9th / 2017 / Hochschule Ruhr-West Y1 - 2017 SN - 978-3-9814801-9-1 U6 - http://dx.doi.org/10.17185/duepublico/43984 N1 - A young researchers track of the 7th IEEE Workshop & SENSORICA 2017 N1 - In der Druckausgabe des Abstractbandes ist dieser Beitrag lose als Erratum beigefügt. SP - 116 EP - 117 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Jabbari, Medisa A1 - Bhattarai, Aroj A1 - Anding, Ralf A1 - Staat, Manfred ED - Erni, Daniel ED - Fischerauer, Alice ED - Himmel, Jörg ED - Seeger, Thomas ED - Thelen, Klaus T1 - Biomechanical simulation of different prosthetic meshes for repairing uterine/vaginal vault prolapse T2 - 2nd YRA MedTech Symposium 2017 : June 8th - 9th / 2017 / Hochschule Ruhr-West Y1 - 2017 SN - 978-3-9814801-9-1 U6 - http://dx.doi.org/10.17185/duepublico/43984 N1 - A young researchers track of the 7th IEEE Workshop & SENSORICA 2017 SP - 118 EP - 119 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Horbach, Andreas A1 - Duong, Minh Tuan A1 - Staat, Manfred T1 - Modelling of compressible and orthotropic surgical mesh implants based on optical deformation measurement JF - Journal of the mechanical behavior of biomedical materials Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.jmbbm.2017.06.012 SN - 1751-6161 VL - 74 SP - 400 EP - 410 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Duong, Minh Tuan A1 - Nguyen, Nhu Huynh A1 - Staat, Manfred T1 - Physical response of hyperelastic models for composite materials and soft tissues T2 - Advances in Composite Material Y1 - 2017 SN - 978-1-61896-300-0 (Hardcover), 978-1-61896-299-7 (Paperback) N1 - Chapter 5 PB - Scientific Research Publishing CY - Wuhan ER - TY - CHAP A1 - Tran, N. T. A1 - Tran, Thanh Ngoc A1 - Matthies, M. G. A1 - Stavroulakis, G. E. A1 - Staat, Manfred T1 - Shakedown Analysis Under Stochastic Uncertainty by Chance Constrained Programming T2 - Advances in Direct Methods for Materials and Structures N2 - In this paper we propose a stochastic programming method to analyse limit and shakedown of structures under uncertainty condition of strength. Based on the duality theory, the shakedown load multiplier formulated by the kinematic theorem is proved actually to be the dual form of the shakedown load multiplier formulated by static theorem. In this investigation a dual chance constrained programming algorithm is developed to calculate simultaneously both the upper and lower bounds of the plastic collapse limit and the shakedown limit. The edge-based smoothed finite element method (ES-FEM) with three-node linear triangular elements is used for structural analysis. Y1 - 2017 SN - 978-3-319-59810-9 U6 - http://dx.doi.org/10.1007/978-3-319-59810-9_6 SP - 85 EP - 103 PB - Springer CY - Cham ER - TY - GEN A1 - Hackl, Michael A1 - Wegmann, Kilian A1 - Kahmann, Stephanie Lucina A1 - Heinze, Nicolai A1 - Staat, Manfred A1 - Neiss, Wolfram F. A1 - Scaal, Martin A1 - Müller, Lars P. T1 - Reply to the letter to the editor: shortening osteotomy of the proximal radius T2 - Knee Surgery, Sports Traumatology, Arthroscopy Y1 - 2017 U6 - http://dx.doi.org/10.1007/s00167-017-4666-8 VL - 25 IS - 10 SP - 3328 EP - 3329 ER - TY - JOUR A1 - Birgel, Stefan A1 - Leschinger, Tim A1 - Wegmann, Kilian A1 - Staat, Manfred T1 - Calculation of muscle forces and joint reaction loads in the shoulder area via an OpenSim based computer model JF - tm - Technisches Messen N2 - Using the OpenSim software and verified anatomical data, a computer model for the calculation of biomechanical parameters is developed and used to determine the effect of a reattachment of the Supraspinatus muscle with a medial displacement of the muscle attachment point, which may be necessary for a rupture of the supraspinatus tendon. The results include the influence of the operation on basic biomechanical parameters such as the lever arm, as well as the calculated the muscle activations for the supraspinatus and deltoid. In addition, the influence on joint stability is examined by an analysis of the joint reaction force. The study provides a detailed description of the used model, as well as medical findings to a reattachment of the supraspinatus. Mit der Software OpenSim und überprüften anatomischen Daten wird ein Computermodell zur Berechnung von biomechanischen Parametern entwickelt und genutzt, um den Effekt einer Refixierung des Supraspinatusmuskels mit einer medialen Verschiebung des Muskelansatzpunktes zu ermitteln, wie sie unter anderem nach einem Riss der Supraspinatussehne notwendig sein kann. Die Ergebnisse umfassen hierbei den Einfluss der Operation auf grundlegende biomechanische Parameter wie den Hebelarm sowie die berechneten Muskelaktivierungen für den Supraspinatus und Deltoideus. Zusätzlich wird der Einfluss auf die Gelenkstabilität betrachtet und durch eine Analyse der Gelenkreaktionskraft untersucht. Die Studie bietet eine detaillierte Beschreibung des genutzten Modells, sowie medizinische Erkenntnisse zu einer Refixierung des Supraspinatus. Y1 - 2018 U6 - http://dx.doi.org/10.1515/teme-2017-0114 SN - 2196-7113 VL - 85 IS - 5 SP - 321 EP - 330 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Bhattarai, Aroj A1 - Jabbari, Medisa A1 - Anding, Ralf A1 - Staat, Manfred T1 - Surgical treatment of vaginal vault prolapse using different prosthetic mesh implants: a finite element analysis JF - tm - Technisches Messen N2 - Particularly multiparous elderly women may suffer from vaginal vault prolapse after hysterectomy due to weak support from lax apical ligaments. A decreased amount of estrogen and progesterone in older age is assumed to remodel the collagen thereby reducing tissue stiffness. Sacrocolpopexy is either performed as open or laparoscopic surgery using prosthetic mesh implants to substitute lax ligaments. Y-shaped mesh models (DynaMesh, Gynemesh, and Ultrapro) are implanted in a 3D female pelvic floor finite element model in the extraperitoneal space from the vaginal cuff to the first sacral (S1) bone below promontory. Numerical simulations are conducted during Valsalva maneuver with weakened tissues modeled by reduced tissue stiffness. Tissues are modeled as incompressible, isotropic hyperelastic materials whereas the meshes are modeled either as orthotropic linear elastic or as isotropic hyperlastic materials. The positions of the vaginal cuff and the bladder base are calculated from the pubococcygeal line for female pelvic floor at rest, for prolapse and after repair using the three meshes. Due to mesh mechanics and mesh pore deformation along the loaded direction, the DynaMesh with regular rectangular mesh pores is found to provide better mechanical support to the organs than the Gynemesh and the Ultrapro with irregular hexagonal mesh pores. Insbesondere ältere, mehrgebährende Frauen leiden häufiger an einem Scheidenvorfall nach einer Hysterektomie aufgrund der schwachen Unterstützung durch laxe apikale Bänder. Es wird angenommen, dass eine verringerte Menge an Östrogen und Progesteron im höheren Alter das Kollagen umformt, wodurch die Gewebesteifigkeit reduziert wird. Die Sakrokolpopexie ist eine offene oder laparoskopische Operation, die mit prothetischen Netzimplantaten durchgeführt wird, um laxe Bänder zu ersetzen. Y-förmige Netzmodelle (DynaMesh, Gynemesh und Ultrapro) werden in einem 3D-Modell des weiblichen Beckenbodens im extraperitonealen Raum vom Vaginalstumpf bis zum Promontorium implantiert. Numerische Simulationen werden während des Valsalva-Manövers mit geschwächtem Gewebe durchgeführt, das durch eine reduzierte Gewebesteifigkeit modelliert wird. Die Gewebe werden als inkompressible, isotrop hyperelastische Materialien modelliert, während die Netze entweder als orthotrope linear elastische oder als isotrope hyperlastische Materialien modelliert werden. Die Positionen des Vaginalstumpfs, der Blase und der Harnröhrenachse werden anhand der Pubococcygeallinie aus der Ruhelage, für den Prolaps und nach der Reparatur unter Verwendung der drei Netze berechnet. Aufgrund der Netzmechanik und der Netzporenverformung bietet das DynaMesh mit regelmäßigen rechteckigen Netzporen eine bessere mechanische Unterstützung und eine Neupositionierung des Scheidengewölbes, der Blase und der Urethraachse als Gynemesh und Ultrapro mit unregelmäßigen hexagonalen Netzporen. Y1 - 2018 U6 - http://dx.doi.org/10.1515/teme-2017-0115 SN - 2196-7113 VL - 85 IS - 5 SP - 331 EP - 342 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Kohler, Annette A1 - Kirschner-Hermanns, Ruth A1 - Staat, Manfred A1 - Brehmer, Bernhard T1 - Pathogenese, funktionelle und anatomische Aspekte der weiblichen Belastungsinkontinenz T1 - Female stress incontinence: aspects of pathogenesis and functional anatomy JF - Aktuelle Urologie N2 - Der vorliegende Artikel fokussiert sich auf die weibliche Belastungsinkontinenz als Insuffizienz der Speicherfunktion der Blase, auch wenn im klinischen Alltag die Harninkontinenz der Frau häufig verschiedene Ursachen hat und insbesondere eine Belastungsinkontinenz im Alter und bei neurologischer Komorbidität nur selten isoliert vorkommt. Das kleine Becken der Frau ist sowohl als Funktions- als auch als strukturelle Einheit zu betrachten. Dabei unterliegen bei der Frau Blase, Harnröhre, Gebärmutter und Enddarm sowie die muskulären und ligamentösen Strukturen des kleinen Beckens durch Fertilitätsphase, mögliche Schwangerschaften, Geburten und Menopausen-Phase, über das „normale Altern“ hinaus, gravierenden Veränderungen. This article focuses on female stress incontinence in the form of pelvic floor dysfunction and urethral sphincter deficiency, although isolated stress incontinence accounts for less than half of all incontinence cases. Especially in women of old age and those with neurological comorbidities, the causes of incontinence are mostly multifactorial. Also it has to be considered that the female bladder, urethra, uterus and rectum as well as the muscular and ligamentous structures of the female pelvis minor are affected by phases of fertility, possible pregnancies, births and menopause in addition to the normal ageing process. Y1 - 2018 U6 - http://dx.doi.org/10.1055/s-0043-120616 SN - 1438-8820 VL - 49 IS - 1 SP - 47 EP - 51 PB - Thieme CY - Stuttgart ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - Computational Analysis of Pelvic Floor Dysfunction T2 - Women's Health and Biomechanics N2 - Pelvic floor dysfunction (PFD) is characterized by the failure of the levator ani (LA) muscle to maintain the pelvic hiatus, resulting in the descent of the pelvic organs below the pubococcygeal line. This chapter adopts the modified Humphrey material model to consider the effect of the muscle fiber on passive stretching of the LA muscle. The deformation of the LA muscle subjected to intra-abdominal pressure during Valsalva maneuver is compared with the magnetic resonance imaging (MRI) examination of a nulliparous female. Numerical result shows that the fiber-based Humphrey model simulates the muscle behavior better than isotropic constitutive models. Greater posterior movement of the LA muscle widens the levator hiatus due to lack of support from the anococcygeal ligament and the perineal structure as a consequence of birth-related injury and aging. Old and multiparous females with uncontrolled urogenital and rectal hiatus tend to develop PFDs such as prolapse and incontinence. KW - Pelvic muscle KW - Muscle fibers KW - Passive stretching KW - Pelvic floor dysfunction Y1 - 2018 SN - 978-3-319-71574-2 U6 - http://dx.doi.org/10.1007/978-3-319-71574-2_17 N1 - Lecture Notes in Computational Vision and Biomechanics, vol 29 SP - 217 EP - 230 PB - Springer CY - Cham ER - TY - JOUR A1 - Bhattarai, Aroj A1 - Staat, Manfred T1 - Modelling of Soft Connective Tissues to Investigate Female Pelvic Floor Dysfunctions JF - Computational and Mathematical Methods in Medicine N2 - After menopause, decreased levels of estrogen and progesterone remodel the collagen of the soft tissues thereby reducing their stiffness. Stress urinary incontinence is associated with involuntary urine leakage due to pathological movement of the pelvic organs resulting from lax suspension system, fasciae, and ligaments. This study compares the changes in the orientation and position of the female pelvic organs due to weakened fasciae, ligaments, and their combined laxity. A mixture theory weighted by respective volume fraction of elastin-collagen fibre compound (5%), adipose tissue (85%), and smooth muscle (5%) is adopted to characterize the mechanical behaviour of the fascia. The load carrying response (other than the functional response to the pelvic organs) of each fascia component, pelvic organs, muscles, and ligaments are assumed to be isotropic, hyperelastic, and incompressible. Finite element simulations are conducted during Valsalva manoeuvre with weakened tissues modelled by reduced tissue stiffness. A significant dislocation of the urethrovesical junction is observed due to weakness of the fascia (13.89 mm) compared to the ligaments (5.47 mm). The dynamics of the pelvic floor observed in this study during Valsalva manoeuvre is associated with urethral-bladder hypermobility, greater levator plate angulation, and positive Q-tip test which are observed in incontinent females. Y1 - 2018 U6 - http://dx.doi.org/10.1155/2018/9518076 SN - 1748-6718 VL - 2018 IS - Article ID 9518076 SP - 1 EP - 16 PB - Hindawi CY - New York, NY ER - TY - JOUR A1 - Jung, Alexander A1 - Müller, Wolfram A1 - Staat, Manfred T1 - Wind and fairness in ski jumping: A computer modelling analysis JF - Journal of Biomechanics N2 - Wind is closely associated with the discussion of fairness in ski jumping. To counter-act its influence on the jump length, the International Ski Federation (FIS) has introduced a wind compensation approach. We applied three differently accurate computer models of the flight phase with wind (M1, M2, and M3) to study the jump length effects of various wind scenarios. The previously used model M1 is accurate for wind blowing in direction of the flight path, but inaccuracies are to be expected for wind directions deviating from the tangent to the flight path. M2 considers the change of airflow direction, but it does not consider the associated change in the angle of attack of the skis which additionally modifies drag and lift area time functions. M3 predicts the length effect for all wind directions within the plane of the flight trajectory without any mathematical simplification. Prediction errors of M3 are determined only by the quality of the input data: wind velocity, drag and lift area functions, take-off velocity, and weight. For comparing the three models, drag and lift area functions of an optimized reference jump were used. Results obtained with M2, which is much easier to handle than M3, did not deviate noticeably when compared to predictions of the reference model M3. Therefore, we suggest to use M2 in future applications. A comparison of M2 predictions with the FIS wind compensation system showed substantial discrepancies, for instance: in the first flight phase, tailwind can increase jump length, and headwind can decrease it; this is opposite of what had been anticipated before and is not considered in the current wind compensation system in ski jumping. Y1 - 2018 U6 - http://dx.doi.org/10.1016/j.jbiomech.2018.05.001 SN - 0021-9290 IS - 75 SP - 147 EP - 153 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Corrigendum to “Flight style optimization in ski jumping on normal, large, and ski flying hills” [J. Biomech 47 (2014) 716–722] JF - Journals of Biomechanics Y1 - 2018 U6 - http://dx.doi.org/10.1016/j.jbiomech.2018.02.001 SN - 0021-9290 N1 - refers to Journal of Biomechanics Vol 47, Issue 3, Pages 716-722: https://doi.org/10.1016/j.jbiomech.2013.11.021 SP - 313 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Tran, Ngoc Trinh A1 - Matthies, Hermann G. A1 - Stavroulakis, Georgios Eleftherios A1 - Staat, Manfred T1 - Direct plastic structural design by chance constrained programming T2 - 6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK N2 - We propose a stochastic programming method to analyse limit and shakedown of structures under random strength with lognormal distribution. In this investigation a dual chance constrained programming algorithm is developed to calculate simultaneously both the upper and lower bounds of the plastic collapse limit or the shakedown limit. The edge-based smoothed finite element method (ES-FEM) using three-node linear triangular elements is used. Y1 - 2018 ER - TY - CHAP A1 - Jung, Alexander A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - Electromechanical model of hiPSC-derived ventricular cardiomyocytes cocultured with fibroblasts T2 - 6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK N2 - The CellDrum provides an experimental setup to study the mechanical effects of fibroblasts co-cultured with hiPSC-derived ventricular cardiomyocytes. Multi-scale computational models based on the Finite Element Method are developed. Coupled electrical cardiomyocyte-fibroblast models (cell level) are embedded into reaction-diffusion equations (tissue level) which compute the propagation of the action potential in the cardiac tissue. Electromechanical coupling is realised by an excitation-contraction model (cell level) and the active stress arising during contraction is added to the passive stress in the force balance, which determines the tissue displacement (tissue level). Tissue parameters in the model can be identified experimentally to the specific sample. Y1 - 2018 ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael ED - Staat, Manfred ED - Heitzer, Michael T1 - Probabilistic limit and shakedown problems T2 - Numerical methods for limit and shakedown analysis. Deterministic and probabilistic problems Y1 - 2003 SN - 3-00-010001-6 N1 - NIC Series VL - 15 SP - 217 EP - 268 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Staat, Manfred ED - Artmann, Gerhard ED - Temiz Artmann, Aysegül ED - Zhubanova, Azhar A. ED - Digel, Ilya T1 - Mechanics of soft tissue reactions to textile mesh implants T2 - Biological, Physical and Technical Basics of Cell Engineering N2 - For pelvic floor disorders that cannot be treated with non-surgical procedures, minimally invasive surgery has become a more frequent and safer repair procedure. More than 20 million prosthetic meshes are implanted each year worldwide. The simple selection of a single synthetic mesh construction for any level and type of pelvic floor dysfunctions without adopting the design to specific requirements increase the risks for mesh related complications. Adverse events are closely related to chronic foreign body reaction, with enhanced formation of scar tissue around the surgical meshes, manifested as pain, mesh erosion in adjacent structures (with organ tissue cut), mesh shrinkage, mesh rejection and eventually recurrence. Such events, especially scar formation depend on effective porosity of the mesh, which decreases discontinuously at a critical stretch when pore areas decrease making the surgical reconstruction ineffective that further augments the re-operation costs. The extent of fibrotic reaction is increased with higher amount of foreign body material, larger surface, small pore size or with inadequate textile elasticity. Standardized studies of different meshes are essential to evaluate influencing factors for the failure and success of the reconstruction. Measurements of elasticity and tensile strength have to consider the mesh anisotropy as result of the textile structure. An appropriate mesh then should show some integration with limited scar reaction and preserved pores that are filled with local fat tissue. This chapter reviews various tissue reactions to different monofilament mesh implants that are used for incontinence and hernia repairs and study their mechanical behavior. This helps to predict the functional and biological outcomes after tissue reinforcement with meshes and permits further optimization of the meshes for the specific indications to improve the success of the surgical treatment. Y1 - 2018 SN - 978-981-10-7904-7 U6 - http://dx.doi.org/10.1007/978-981-10-7904-7_11 SP - 251 EP - 275 PB - Springer CY - Singapore ER - TY - CHAP A1 - Duong, Minh Tuan A1 - Seifarth, Volker A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard A1 - Staat, Manfred ED - Artmann, Gerhard ED - Temiz Artmann, Aysegül ED - Zhubanova, Azhar A. ED - Digel, Ilya T1 - Growth Modelling Promoting Mechanical Stimulation of Smooth Muscle Cells of Porcine Tubular Organs in a Fibrin-PVDF Scaffold T2 - Biological, Physical and Technical Basics of Cell Engineering N2 - Reconstructive surgery and tissue replacements like ureters or bladders reconstruction have been recently studied, taking into account growth and remodelling of cells since living cells are capable of growing, adapting, remodelling or degrading and restoring in order to deform and respond to stimuli. Hence, shapes of ureters or bladders and their microstructure change during growth and these changes strongly depend on external stimuli such as training. We present the mechanical stimulation of smooth muscle cells in a tubular fibrin-PVDFA scaffold and the modelling of the growth of tissue by stimuli. To this end, mechanotransduction was performed with a kyphoplasty balloon catheter that was guided through the lumen of the tubular structure. The bursting pressure was examined to compare the stability of the incubated tissue constructs. The results showed the significant changes on tissues with training by increasing the burst pressure as a characteristic mechanical property and the smooth muscle cells were more oriented with uniformly higher density. Besides, the computational growth models also exhibited the accurate tendencies of growth of the cells under different external stimuli. Such models may lead to design standards for the better layered tissue structure in reconstructing of tubular organs characterized as composite materials such as intestines, ureters and arteries. KW - Mechanical simulation KW - Growth modelling KW - Ureter KW - Bladder KW - Reconstruction Y1 - 2018 SN - 978-981-10-7904-7 U6 - http://dx.doi.org/10.1007/978-981-10-7904-7_9 SP - 209 EP - 232 PB - Springer CY - Singapore ER - TY - CHAP A1 - Frotscher, Ralf A1 - Staat, Manfred ED - Artmann, Gerhard ED - Temiz Artmann, Aysegül ED - Zhubanova, Azhar A. ED - Digel, Ilya T1 - Towards Patient-Specific Computational Modeling of hiPS-Derived Cardiomyocyte Function and Drug Action T2 - Biological, Physical and Technical Basics of Cell Engineering N2 - Human-induced pluripotent stem cell-derived cardiomyocytes (hiPS-CM) today are widely used for the investigation of normal electromechanical cardiac function, of cardiac medication and of mutations. Computational models are thus established that simulate the behavior of this kind of cells. This section first motivates the modeling of hiPS-CM and then presents and discusses several modeling approaches of microscopic and macroscopic constituents of human-induced pluripotent stem cell-derived and mature human cardiac tissue. The focus is led on the mapping of the computational results one can achieve with these models onto mature human cardiomyocyte models, the latter being the real matter of interest. Model adaptivity is the key feature that is discussed because it opens the way for modeling various biological effects like biological variability, medication, mutation and phenotypical expression. We compare the computational with experimental results with respect to normal cardiac function and with respect to inotropic and chronotropic drug effects. The section closes with a discussion on the status quo of the specificity of computational models and on what challenges have to be solved to reach patient-specificity. Y1 - 2018 SN - 978-981-10-7904-7 U6 - http://dx.doi.org/10.1007/978-981-10-7904-7_10 SP - 233 EP - 250 PB - Springer CY - Singapore ER - TY - CHAP A1 - Kahmann, Stephanie Lucina A1 - Uschok, Stephan A1 - Wegmann, Kilian A1 - Müller, Lars-P. A1 - Staat, Manfred T1 - Biomechanical multibody model with refined kinematics of the elbow T2 - 6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK N2 - The overall objective of this study is to develop a new external fixator, which closely maps the native kinematics of the elbow to decrease the joint force resulting in reduced rehabilitation time and pain. An experimental setup was designed to determine the native kinematics of the elbow during flexion of cadaveric arms. As a preliminary study, data from literature was used to modify a published biomechanical model for the calculation of the joint and muscle forces. They were compared to the original model and the effect of the kinematic refinement was evaluated. Furthermore, the obtained muscle forces were determined in order to apply them in the experimental setup. The joint forces in the modified model differed slightly from the forces in the original model. The muscle force curves changed particularly for small flexion angles but their magnitude for larger angles was consistent. Y1 - 2018 ER - TY - CHAP A1 - Goh, Kheng Lim A1 - Topçu, Murat A1 - Madabhushi, Gopal S. P. A1 - Staat, Manfred ED - Maia, Fatima Raquel Azevedo ED - Miguel Oliveira, J. ED - Reis, Rui L. T1 - Collagen fibril reinforcement in connective tissue extracellular matrices T2 - Handbook of the extracellular matrix N2 - The connective tissues such as tendons contain an extracellular matrix (ECM) comprising collagen fibrils scattered within the ground substance. These fibrils are instrumental in lending mechanical stability to tissues. Unfortunately, our understanding of how collagen fibrils reinforce the ECM remains limited, with no direct experimental evidence substantiating current theories. Earlier theoretical studies on collagen fibril reinforcement in the ECM have relied predominantly on the assumption of uniform cylindrical fibers, which is inadequate for modelling collagen fibrils, which possessed tapered ends. Recently, Topçu and colleagues published a paper in the International Journal of Solids and Structures, presenting a generalized shear-lag theory for the transfer of elastic stress between the matrix and fibers with tapered ends. This paper is a positive step towards comprehending the mechanics of the ECM and makes a valuable contribution to formulating a complete theory of collagen fibril reinforcement in the ECM. KW - Connective tissues KW - Extracellular matrix (ECM) KW - Collagen fibrils KW - Mechanical stability KW - Tapered ends Y1 - 2023 SN - 978-3-030-92090-6 (Print) SN - 978-3-030-92090-6 (Online) U6 - http://dx.doi.org/10.1007/978-3-030-92090-6_6-1 SP - 1 EP - 20 PB - Springer Nature CY - Cham ER - TY - CHAP A1 - Bhattarai, Aroj A1 - Staat, Manfred ED - Fernandes, P.R. ED - Tavares, J. M. T1 - Pectopexy to repair vaginal vault prolapse: a finite element approach T2 - Proceedings CMBBE 2018 N2 - The vaginal prolapse after hysterectomy (removal of the uterus) is often associated with the prolapse of the vaginal vault, rectum, bladder, urethra or small bowel. Minimally invasive surgery such as laparoscopic sacrocolpopexy and pectopexy are widely performed for the treatment of the vaginal prolapse with weakly supported vaginal vault after hysterectomy using prosthetic mesh implants to support (or strengthen) lax apical ligaments. Implants of different shape, size and polymers are selected depending on the patient’s anatomy and the surgeon’s preference. In this computational study on pectopexy, DynaMesh®-PRP soft, GYNECARE GYNEMESH® PS Nonabsorbable PROLENE® soft and Ultrapro® are tested in a 3D finite element model of the female pelvic floor. The mesh model is implanted into the extraperitoneal space and sutured to the vaginal stump with a bilateral fixation to the iliopectineal ligament at both sides. Numerical simulations are conducted at rest, after surgery and during Valsalva maneuver with weakened tissues modeled by reduced tissue stiffness. Tissues and prosthetic meshes are modeled as incompressible, isotropic hyperelastic materials. The positions of the organs are calculated with respect to the pubococcygeal line (PCL) for female pelvic floor at rest, after repair and during Valsalva maneuver using the three meshes. Y1 - 2018 N1 - 15th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering and 3rd Conference on Imaging and Visualization. CMBBE 2018. 26-29 March 2018, Lisbon, Portugal ER - TY - JOUR A1 - Leschinger, Tim A1 - Birgel, Stefan A1 - Hackl, Michael A1 - Staat, Manfred A1 - Müller, Lars Peter A1 - Wegmann, Kilian T1 - A musculoskeletal shoulder simulation of moment arms and joint reaction forces after medialization of the supraspinatus footprint in rotator cuff repair JF - Computer Methods in Biomechanics and Biomedical Engineering Y1 - 2019 U6 - http://dx.doi.org/10.1080/10255842.2019.1572749 IS - Early view PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Horbach, Andreas A1 - Staat, Manfred T1 - Optical strain measurement for the modeling of surgical meshes and their porosity JF - Current Directions in Biomedical Engineering N2 - The porosity of surgical meshes makes them flexible for large elastic deformation and establishes the healing conditions of good tissue in growth. The biomechanic modeling of orthotropic and compressible materials requires new materials models and simulstaneoaus fit of deformation in the load direction as well as trannsversely to to load. This nonlinear modeling can be achieved by an optical deformation measurement. At the same time the full field deformation measurement allows the dermination of the change of porosity with deformation. Also the socalled effective porosity, which has been defined to asses the tisssue interatcion with the mesh implants, can be determined from the global deformation of the surgical meshes. Y1 - 2018 U6 - http://dx.doi.org/10.1515/cdbme-2018-0045 SN - 2364-5504 VL - Band 4 IS - 1 SP - 181 EP - 184 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Bhattarai, Aroj A1 - Staat, Manfred T1 - Computational comparison of different textile implants to correct apical prolapse in females JF - Current Directions in Biomedical Engineering N2 - Prosthetic textile implants of different shapes, sizes and polymers are used to correct the apical prolapse after hysterectomy (removal of the uterus). The selection of the implant before or during minimally invasive surgery depends on the patient’s anatomical defect, intended function after reconstruction and most importantly the surgeon’s preference. Weakness or damage of the supporting tissues during childbirth, menopause or previous pelvic surgeries may put females in higher risk of prolapse. Numerical simulations of reconstructed pelvic floor with weakened tissues and organ supported by textile product models: DynaMesh®-PRS soft, DynaMesh®-PRP soft and DynaMesh®-CESA from FEG Textiletechnik mbH, Germany are compared. Y1 - 2018 U6 - http://dx.doi.org/10.1515/cdbme-2018-0159 VL - 4 IS - 1 SP - 661 EP - 664 PB - De Gruyter CY - Berlin ER - TY - RPRT A1 - Bhattarai, Aroj A1 - Frotscher, Ralf A1 - Durong, Minh Tuán A1 - Staat, Manfred T1 - Schlussbericht zu BINGO. Optimierung des Systems Netzimplantat-Beckenboden zur therapeutischen Gewebeverstärkung nach der Integraltheorie. Y1 - 2016 N1 - Förderkennzeichen BMBF 03FH073PX2 CY - Aachen ER - TY - JOUR A1 - Staat, Manfred T1 - Rezension zu: K. Zimmermann, Technische Mechanik – multimedial. Fachbuch Verlag Leipzig (2000) JF - Technische Mechanik Y1 - 2002 SN - 0232-3869 VL - 22 IS - 1 SP - 76 EP - 77 ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred T1 - Modeling and simulation of human induced pluripotent stem cell-derived cardiac tissue JF - GAMM - Mitteilungen der Gesellschaft für Angewandte Mathematik und Mechanik Y1 - 2019 U6 - http://dx.doi.org/10.1002/gamm.201900002 SN - 1522-2608 VL - 42 IS - 4 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Schieren, Mark A1 - Kleinschmidt, Joris A1 - Schmutz, Axel A1 - Loop, Torsten A1 - Gatzweiler, Karl-Heinz A1 - Staat, Manfred A1 - Wappler, Frank A1 - Defosse, Jerome T1 - Comparison of forces acting on maxillary incisors during tracheal intubation with different laryngoscopy techniques: a blinded manikin study JF - Anaesthesia Y1 - 2019 SN - 1365-2044 U6 - http://dx.doi.org/10.1111/anae.14815 N1 - Die Anhänge "Table S1 (Impact of sex and level of training on dental force. Results presented as median (IQR [range]) and n (%))" und "Appendix S1 (Measurement technique.)" stehen unter "Supporting Information" zum Download bereit. VL - 74 IS - 12 PB - Wiley-Blackwell CY - Oxford ER - TY - JOUR A1 - Linder, Peter A1 - Beckler, Matthias A1 - Doerr, Leo A1 - Stoelzle-Feix, Sonja A1 - Fertig, Niels A1 - Jung, Alexander A1 - Staat, Manfred A1 - Gossmann, Matthias T1 - A new in vitro tool to investigate cardiac contractility under physiological mechanical conditions JF - Journal of Pharmacological and Toxicological Methods Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.vascn.2019.05.162 SN - 1056-8719 VL - 99 IS - Article number 106595 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Gossmann, Matthias A1 - Thomas, Ulrich A1 - Horváth, András A1 - Dragicevic, Elena A1 - Stoelzle-Feix, Sonja A1 - Jung, Alexander A1 - Raman, Aravind Hariharan A1 - Staat, Manfred A1 - Linder, Peter T1 - A higher-throughput approach to investigate cardiac contractility in vitro under physiological mechanical conditions JF - Journal of Pharmacological and Toxicological Methods Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.vascn.2020.106843 VL - 105 IS - Article 106843 PB - Elsevier CY - New York, NY ER - TY - CHAP A1 - Tran, Ngoc Trinh A1 - Staat, Manfred T1 - FEM shakedown analysis of Kirchhoff-Love plates under uncertainty of strength T2 - Proceedings of UNCECOMP 2021 N2 - A new formulation to calculate the shakedown limit load of Kirchhoff plates under stochastic conditions of strength is developed. Direct structural reliability design by chance con-strained programming is based on the prescribed failure probabilities, which is an effective approach of stochastic programming if it can be formulated as an equivalent deterministic optimization problem. We restrict uncertainty to strength, the loading is still deterministic. A new formulation is derived in case of random strength with lognormal distribution. Upper bound and lower bound shakedown load factors are calculated simultaneously by a dual algorithm. Y1 - 2021 SN - 978-618-85072-6-5 U6 - http://dx.doi.org/10.7712/120221.8041.19047 N1 - Proceedings of UNCECOMP 2021, 4th International Conference on Uncertainty Quantification in Computational Sciences and Engineering, streamed from Athens, Greece, 28–30 June 2021. SP - 323 EP - 338 ER - TY - JOUR A1 - Hackl, Michael A1 - Buess, Eduard A1 - Kammerlohr, Sandra A1 - Nacov, Julia A1 - Staat, Manfred A1 - Leschinger, Tim A1 - Müller, Lars P. A1 - Wegmann, Kilian T1 - A "comma sign"-directed subscapularis repair in anterosuperior rotator cuff tears yields biomechanical advantages in a cadaveric model JF - The american journal of sports medicine Y1 - 2021 U6 - http://dx.doi.org/10.1177/03635465211031506 SN - 1552-3365 SN - 0363-5465 VL - 49 IS - 12 SP - 3212 EP - 3217 PB - Sage CY - London ER - TY - JOUR A1 - Staat, Manfred T1 - An extension strain type Mohr–Coulomb criterion JF - Rock mechanics and rock engineering N2 - Extension fractures are typical for the deformation under low or no confining pressure. They can be explained by a phenomenological extension strain failure criterion. In the past, a simple empirical criterion for fracture initiation in brittle rock has been developed. In this article, it is shown that the simple extension strain criterion makes unrealistic strength predictions in biaxial compression and tension. To overcome this major limitation, a new extension strain criterion is proposed by adding a weighted principal shear component to the simple criterion. The shear weight is chosen, such that the enriched extension strain criterion represents the same failure surface as the Mohr–Coulomb (MC) criterion. Thus, the MC criterion has been derived as an extension strain criterion predicting extension failure modes, which are unexpected in the classical understanding of the failure of cohesive-frictional materials. In progressive damage of rock, the most likely fracture direction is orthogonal to the maximum extension strain leading to dilatancy. The enriched extension strain criterion is proposed as a threshold surface for crack initiation CI and crack damage CD and as a failure surface at peak stress CP. Different from compressive loading, tensile loading requires only a limited number of critical cracks to cause failure. Therefore, for tensile stresses, the failure criteria must be modified somehow, possibly by a cut-off corresponding to the CI stress. Examples show that the enriched extension strain criterion predicts much lower volumes of damaged rock mass compared to the simple extension strain criterion. Y1 - 2021 U6 - http://dx.doi.org/10.1007/s00603-021-02608-7 SN - 1434-453X N1 - Corresponding author: Manfred Staat VL - 54 IS - 12 SP - 6207 EP - 6233 PB - Springer Nature CY - Cham ER - TY - CHAP A1 - Tran, Ngoc Trinh A1 - Trinh, Tu Luc A1 - Dao, Ngoc Tien A1 - Giap, Van Tan A1 - Truong, Manh Khuyen A1 - Dinh, Thuy Ha A1 - Staat, Manfred T1 - Limit and shakedown analysis of structures under random strength T2 - Proceedings of (NACOME2022) The 11th National Conference on Mechanics, Vol. 1. Solid Mechanics, Rock Mechanics, Artificial Intelligence, Teaching and Training, Hanoi, December 2-3, 2022 N2 - Direct methods comprising limit and shakedown analysis is a branch of computational mechanics. It plays a significant role in mechanical and civil engineering design. The concept of direct method aims to determinate the ultimate load bearing capacity of structures beyond the elastic range. For practical problems, the direct methods lead to nonlinear convex optimization problems with a large number of variables and onstraints. If strength and loading are random quantities, the problem of shakedown analysis is considered as stochastic programming. This paper presents a method so called chance constrained programming, an effective method of stochastic programming, to solve shakedown analysis problem under random condition of strength. In this our investigation, the loading is deterministic, the strength is distributed as normal or lognormal variables. KW - Reliability of structures KW - Stochastic programming KW - Chance constrained programming KW - Shakedown analysis KW - Limit analysis Y1 - 2022 SN - 978-604-357-084-7 SP - 510 EP - 518 PB - Nha xuat ban Khoa hoc tu nhien va Cong nghe (Verlag Naturwissenschaft und Technik) CY - Hanoi ER - TY - JOUR A1 - Jayaraman, Chandrasekaran A1 - Mummidisetty, Chaitanya Krishna A1 - Loesch, Alexandra A1 - Kaur, Sandi A1 - Hoppe-Ludwig, Shenan A1 - Staat, Manfred A1 - Jayaraman, Arun T1 - Postural and metabolic benefits of using a forearm support walker in older adults with impairments JF - Archives of Physical Medicine and Rehabilitation Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.apmr.2018.10.001 SN - 0003-9993 VL - Volume 100 IS - Issue 4 SP - 638 EP - 647 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Tran, Ngoc Trinh A1 - Staat, Manfred T1 - Direct plastic structural design under lognormally distributed strength by chance constrained programming JF - Optimization and Engineering N2 - We propose the so-called chance constrained programming model of stochastic programming theory to analyze limit and shakedown loads of structures under random strength with a lognormal distribution. A dual chance constrained programming algorithm is developed to calculate simultaneously both the upper and lower bounds of the plastic collapse limit and the shakedown limit. The edge-based smoothed finite element method (ES-FEM) is used with three-node linear triangular elements. Y1 - 2020 U6 - http://dx.doi.org/10.1007/s11081-019-09437-2 SN - 1573-2924 VL - 21 IS - 1 SP - 131 EP - 157 PB - Springer Nature CY - Cham ER - TY - JOUR A1 - Meyer, Carolin A1 - Gaalen, Kerstin van A1 - Leschinger, Tim A1 - Scheyerer, Max J. A1 - Neiss, Wolfram F. A1 - Staat, Manfred A1 - Müller, Lars P. A1 - Wegmann, Kilian T1 - Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement JF - BioMed Research International Y1 - 2019 U6 - http://dx.doi.org/10.1155/2019/9232813 SP - Article ID 9232813 ER - TY - PAT A1 - Staat, Manfred A1 - Horbach, Andreas A1 - Gatzweiler, Karl-Heinz T1 - Biaxiales Materialprüfsystem und Verfahren zu dessen Anwendung N2 - System und Verfahren zur Durchführung von Messungen biaxialer und kreuzförmiger Zugversuche, wobei ein Weg oder eine Kraft auf eine Materialprobe über mindestens zwei Nadelarme mit Nadeln geleitet wird, die in einem Gehäuse gelagert sind, wobei die Arme und/oder Nadelarme für eine ungehinderte Querkontraktion bei gleichmäßiger Lasteinleitung um eine Achse drehbar gelagert und seitlich auslenkbar sind. Y1 - 2019 N1 - Patent DE102017116067 ER - TY - BOOK A1 - Staat, Manfred A1 - Erni, Daniel T1 - Symposium Proceedings; 3rd YRA MedTech Symposium 2019: May 24 / 2019 / FH Aachen Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Hunker, Jan A1 - Jung, Alexander A1 - Goßmann, Matthias A1 - Linder, Peter A1 - Staat, Manfred ED - Staat, Manfred ED - Erni, Daniel T1 - Development of a tool to analyze the conduction speed in microelectrode array measurements of cardiac tissue T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - The discovery of human induced pluripotent stem cells reprogrammed from somatic cells [1] and their ability to differentiate into cardiomyocytes (hiPSC-CMs) has provided a robust platform for drug screening [2]. Drug screenings are essential in the development of new components, particularly for evaluating the potential of drugs to induce life-threatening pro-arrhythmias. Between 1988 and 2009, 14 drugs have been removed from the market for this reason [3]. The microelectrode array (MEA) technique is a robust tool for drug screening as it detects the field potentials (FPs) for the entire cell culture. Furthermore, the propagation of the field potential can be examined on an electrode basis. To analyze MEA measurements in detail, we have developed an open-source tool. Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 7 EP - 8 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Raman, Aravind Hariharan A1 - Jung, Alexander A1 - Horváth, András A1 - Becker, Nadine A1 - Staat, Manfred ED - Staat, Manfred ED - Erni, Daniel T1 - Modification of a computer model of human stem cell-derived cardiomyocyte electrophysiology based on Patch-Clamp measurements T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - Human induced pluripotent stem cells (hiPSCs) have shown to be promising in disease studies and drug screenings [1]. Cardiomyocytes derived from hiPSCs have been extensively investigated using patch-clamping and optical methods to compare their electromechanical behaviour relative to fully matured adult cells. Mathematical models can be used for translating findings on hiPSCCMs to adult cells [2] or to better understand the mechanisms of various ion channels when a drug is applied [3,4]. Paci et al. (2013) [3] developed the first model of hiPSC-CMs, which they later refined based on new data [3]. The model is based on iCells® (Fujifilm Cellular Dynamics, Inc. (FCDI), Madison WI, USA) but major differences among several cell lines and even within a single cell line have been found and motivate an approach for creating sample-specific models. We have developed an optimisation algorithm that parameterises the conductances (in S/F=Siemens/Farad) of the latest Paci et al. model (2018) [5] using current-voltage data obtained in individual patch-clamp experiments derived from an automated patch clamp system (Patchliner, Nanion Technologies GmbH, Munich). Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 10 EP - 11 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Jung, Alexander A1 - Müller, Wolfram A1 - Staat, Manfred T1 - Optimization of the flight technique in ski jumping: the influence of wind Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.jbiomech.2019.03.023 IS - Early view PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Knox, Ronald A1 - Bruggemann, Andrea A1 - Gossmann, Matthias A1 - Thomas, Ulrich A1 - Horváth, András A1 - Dragicevic, Elena A1 - Stoelzle-Feix, Sonja A1 - Fertig, Niels A1 - Jung, Alexander A1 - Raman, Aravind Hariharan A1 - Staat, Manfred A1 - Linder, Peter T1 - Combining physiological relevance and throughput for in vitro cardiac contractility measurement JF - Biophysical Journal N2 - Despite increasing acceptance of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) in safety pharmacology, controversy remains about the physiological relevance of existing in vitro models for their mechanical testing. We hypothesize that existing signs of immaturity of the cell models result from an improper mechanical environment. We cultured hiPSC-CMs in a 96-well format on hyperelastic silicone membranes imitating their native mechanical environment, resulting in physiological responses to compound stimuli.We validated cell responses on the FLEXcyte 96, with a set of reference compounds covering a broad range of cellular targets, including ion channel modulators, adrenergic receptor modulators and kinase inhibitors. Acute (10 - 30 min) and chronic (up to 7 days) effects were investigated. Furthermore, the measurements were complemented with electromechanical models based on electrophysiological recordings of the used cell types.hiPSC-CMs were cultured on freely-swinging, ultra-thin and hyperelastic silicone membranes. The weight of the cell culture medium deflects the membranes downwards. Rhythmic contraction of the hiPSC-CMs resulted in dynamic deflection changes which were quantified by capacitive distance sensing. The cells were cultured for 7 days prior to compound addition. Acute measurements were conducted 10-30 minutes after compound addition in standard culture medium. For chronic treatment, compound-containing medium was replaced daily for up to 7 days. Electrophysiological properties of the employed cell types were recorded by automated patch-clamp (Patchliner) and the results were integrated into the electromechanical model of the system.Calcium channel agonist S Bay K8644 and beta-adrenergic stimulator isoproterenol induced significant positive inotropic responses without additional external stimulation. Kinase inhibitors displayed cardiotoxic effects on a functional level at low concentrations. The system-integrated analysis detected alterations in beating shape as well as frequency and arrhythmic events and we provide a quantitative measure of these. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.bpj.2019.11.3104 SN - 0006-3495 N1 - Raman, Arayind Hariharan im Artikel unter dem Namen: Raman, Alexander H. VL - 118 IS - Issue 3, Supplement 1 SP - 570a PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Rausch, Valentin A1 - Kahmann, Stephanie Lucina A1 - Baltschun, Christoph A1 - Staat, Manfred A1 - Müller, Lars P. A1 - Wegmann, Kilian T1 - Pressure distribution to the distal biceps tendon at the radial tuberosity: a biomechanical study JF - The Journal of Hand Surgery N2 - Purpose Mechanical impingement at the narrow radioulnar space of the tuberosity is believed to be an etiological factor in the injury of the distal biceps tendon. The aim of the study was to compare the pressure distribution at the proximal radioulnar space between 2 fixation techniques and the intact state. Methods Six right arms and 6 left arms from 5 female and 6 male frozen specimens were used for this study. A pressure transducer was introduced at the height of the radial tuberosity with the intact distal biceps tendon and after 2 fixation methods: the suture-anchor and the cortical button technique. The force (N), maximum pressure (kPa) applied to the radial tuberosity, and the contact area (mm²) of the radial tuberosity with the ulna were measured and differences from the intact tendon were detected from 60° supination to 60° pronation in 15° increments with the elbow in full extension and in 45° and 90° flexion of the elbow. Results With the distal biceps tendon intact, the pressures during pronation were similar regardless of extension and flexion and were the highest at 60° pronation with 90° elbow flexion (23.3 ± 53.5 kPa). After repair of the tendon, the mean peak pressure, contact area, and total force showed an increase regardless of the fixation technique. Highest peak pressures were found using the cortical button technique at 45° flexion of the elbow and 60° pronation. These differences were significantly different from the intact tendon. The contact area was significantly larger in full extension and 15°, 30°, and 60° pronation using the cortical button technique. Conclusions Pressures on the distal biceps tendon at the radial tuberosity increase during pronation, especially after repair of the tendon. Clinical relevance Mechanical impingement could play a role in both the etiology of primary distal biceps tendon ruptures and the complications occurring after fixation of the tendon using certain techniques. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.jhsa.2020.01.006 SN - 0363-5023 VL - 45 IS - 8 SP - 776.e1 EP - 776.e9 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Abel, Alexander A1 - Kahmann, Stephanie Lucina A1 - Mellon, Stephen A1 - Staat, Manfred A1 - Jung, Alexander T1 - An open-source tool for the validation of finite element models using three-dimensional full-field measurements JF - Medical Engineering & Physics N2 - Three-dimensional (3D) full-field measurements provide a comprehensive and accurate validation of finite element (FE) models. For the validation, the result of the model and measurements are compared based on two respective point-sets and this requires the point-sets to be registered in one coordinate system. Point-set registration is a non-convex optimization problem that has widely been solved by the ordinary iterative closest point algorithm. However, this approach necessitates a good initialization without which it easily returns a local optimum, i.e. an erroneous registration. The globally optimal iterative closest point (Go-ICP) algorithm has overcome this drawback and forms the basis for the presented open-source tool that can be used for the validation of FE models using 3D full-field measurements. The capability of the tool is demonstrated using an application example from the field of biomechanics. Methodological problems that arise in real-world data and the respective implemented solution approaches are discussed. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.medengphy.2019.10.015 SN - 1350-4533 VL - 77 SP - 125 EP - 129 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hackl, Michael A1 - Nacov, Julia A1 - Kammerlohr, Sandra A1 - Staat, Manfred A1 - Buess, Eduard A1 - Leschinger, Tim A1 - Müller, Lars P. A1 - Wegmann, Kilian T1 - Intratendinous Strain Variations of the Supraspinatus Tendon Depending on Repair Technique: A Biomechanical Analysis Regarding the Cause of Medial Cuff Failure JF - The American Journal of Sports Medicine Y1 - 2021 U6 - http://dx.doi.org/10.1177/03635465211006138 SN - 1552-3365 SN - 0363-5465 VL - 49 IS - 7 SP - 1847 EP - 1853 PB - Sage CY - London ER - TY - RPRT A1 - Stölzle-Feix, Sonja A1 - Thomas, Ulrich A1 - Engelstädter, Max A1 - Goßmann, Matthias A1 - Linder, Peter A1 - Staat, Manfred A1 - Raman, Aravind Hariharan A1 - Jung, Alexander A1 - Fertig, Niels T1 - Plattformtechnologie für kardiale Sicherheitspharmakologie basierend auf teilsynthetischem Herzmuskelgewebe (FLEXcyte) : gemeinsamer FuE-Abschlussbericht aller Partner des Verbundprojektes : Projektlaufzeit: 01.10.2018 bis 30.09.2020 Y1 - 2021 U6 - http://dx.doi.org/10.2314/KXP:1813208581 N1 - Förderkennzeichen BMBF 02P18K020-021 Verbundnummer 01185221 PB - Nanion Technologies GmbH CY - München ER - TY - GEN A1 - Jung, Alexander A1 - Müller, Wolfram A1 - Staat, Manfred T1 - Corrigendum to “Wind and fairness in ski jumping: A computer modelling analysis” [J. Biomech. 75 (2018) 147–153] T2 - Journal of Biomechanics Y1 - 2021 U6 - http://dx.doi.org/10.1016/j.jbiomech.2021.110690 SN - 0021-9290 N1 - Refers to: Alexander Jung, Wolfram Müller, Manfred Staat: Wind and fairness in ski jumping: A computer modelling analysis. Journal of Biomechanics, Volume 75. 25 June 2018. Pages 147-153. https://doi.org/10.1016/j.jbiomech.2018.05.001 VL - 128 IS - Article number: 110690 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred T1 - Erratum to "Modeling and simulation of human induced pluripotent stem cell-derived cardiac tissue" [GAMM-Mitteilungen, (2019), 42, 4, 10.1002/gamm.201900002] JF - GAMM-Mitteilungen Y1 - 2020 U6 - http://dx.doi.org/10.1002/gamm.202000011 SN - 1522-2608 N1 - Refers to: Modeling and simulation of human induced pluripotent stem cell-derived cardiac tissue. Alexander Jung, Manfred Staat. Volume 42, Issue 4. GAMM-Mitteilungen, 2019. https://doi.org/10.1002/gamm.201900002 VL - 43 IS - 4 PB - Wiley-VCH GmbH CY - Weinheim ER - TY - JOUR A1 - Bhattarai, Aroj A1 - Horbach, Andreas A1 - Staat, Manfred A1 - Kowalczyk, Wojciech A1 - Tran, Thanh Ngoc T1 - Virgin passive colon biomechanics and a literature review of active contraction constitutive models JF - Biomechanics N2 - The objective of this paper is to present our findings on the biomechanical aspects of the virgin passive anisotropic hyperelasticity of the porcine colon based on equibiaxial tensile experiments. Firstly, the characterization of the intestine tissues is discussed for a nearly incompressible hyperelastic fiber-reinforced Holzapfel–Gasser–Ogden constitutive model in virgin passive loading conditions. The stability of the evaluated material parameters is checked for the polyconvexity of the adopted strain energy function using positive eigenvalue constraints of the Hessian matrix with MATLAB. The constitutive material description of the intestine with two collagen fibers in the submucosal and muscular layer each has been implemented in the FORTRAN platform of the commercial finite element software LS-DYNA, and two equibiaxial tensile simulations are presented to validate the results with the optical strain images obtained from the experiments. Furthermore, this paper also reviews the existing models of the active smooth muscle cells, but these models have not been computationally studied here. The review part shows that the constitutive models originally developed for the active contraction of skeletal muscle based on Hill’s three-element model, Murphy’s four-state cross-bridge chemical kinetic model and Huxley’s sliding-filament hypothesis, which are mainly used for arteries, are appropriate for numerical contraction numerical analysis of the large intestine. KW - virgin passive KW - strain energy function KW - smooth muscle contraction KW - viscoelasticity KW - damage Y1 - 2022 U6 - http://dx.doi.org/10.3390/biomechanics2020013 SN - 2673-7078 VL - 2 IS - 2 SP - 138 EP - 157 PB - MDPI CY - Basel ER - TY - CHAP A1 - Staat, Manfred A1 - Tran, Ngoc Trinh T1 - Strain based brittle failure criteria for rocks T2 - Proceedings of (NACOME2022) The 11th National Conference on Mechanics, Vol. 1. Solid Mechanics, Rock Mechanics, Artificial Intelligence, Teaching and Training, Hanoi, December 2-3, 2022 N2 - When confining pressure is low or absent, extensional fractures are typical, with fractures occurring on unloaded planes in rock. These “paradox” fractures can be explained by a phenomenological extension strain failure criterion. In the past, a simple empirical criterion for fracture initiation in brittle rock has been developed. But this criterion makes unrealistic strength predictions in biaxial compression and tension. A new extension strain criterion overcomes this limitation by adding a weighted principal shear component. The weight is chosen, such that the enriched extension strain criterion represents the same failure surface as the Mohr–Coulomb (MC) criterion. Thus, the MC criterion has been derived as an extension strain criterion predicting failure modes, which are unexpected in the understanding of the failure of cohesive-frictional materials. In progressive damage of rock, the most likely fracture direction is orthogonal to the maximum extension strain. The enriched extension strain criterion is proposed as a threshold surface for crack initiation CI and crack damage CD and as a failure surface at peak P. Examples show that the enriched extension strain criterion predicts much lower volumes of damaged rock mass compared to the simple extension strain criterion. KW - Extension fracture KW - Extension strain criterion KW - Mohr–Coulomb criterion KW - Evolution of damage Y1 - 2023 SN - 978-604-357-084-7 SP - 500 EP - 509 PB - Nha xuat ban Khoa hoc tu nhien va Cong nghe (Verlag Naturwissenschaft und Technik) CY - Hanoi ER - TY - JOUR A1 - Tran, Ngoc Trinh A1 - Trinh, Tu Luc A1 - Dao, Ngoc Tien A1 - Giap, Van Tan A1 - Truong, Manh Khuyen A1 - Dinh, Thuy Ha A1 - Staat, Manfred T1 - FEM shakedown analysis of structures under random strength with chance constrained programming JF - Vietnam Journal of Mechanics N2 - Direct methods, comprising limit and shakedown analysis, are a branch of computational mechanics. They play a significant role in mechanical and civil engineering design. The concept of direct methods aims to determine the ultimate load carrying capacity of structures beyond the elastic range. In practical problems, the direct methods lead to nonlinear convex optimization problems with a large number of variables and constraints. If strength and loading are random quantities, the shakedown analysis can be formulated as stochastic programming problem. In this paper, a method called chance constrained programming is presented, which is an effective method of stochastic programming to solve shakedown analysis problems under random conditions of strength. In this study, the loading is deterministic, and the strength is a normally or lognormally distributed variable. KW - limit analysis KW - shakedown analysis KW - chance constrained programming KW - stochastic programming KW - reliability of structures Y1 - 2022 U6 - http://dx.doi.org/10.15625/0866-7136/17943 SN - 0866-7136 SN - 2815-5882 VL - 44 IS - 4 SP - 459 EP - 473 PB - Vietnam Academy of Science and Technology (VAST) ER - TY - GEN A1 - Topcu, Murat A1 - Madabhushi, Gopal Santana Phani A1 - Staat, Manfred T1 - Datasets from FEM Simulations done with COMSOL Multiphysics and Code_Aster N2 - Datasets from FEM Simulations done with COMSOL Multiphysics and Code_Aster for an elastic stress transfer between matrix and fibres having a variable radius. KW - Natural fibres KW - Polymer-matrix composites KW - Biocomposites KW - Stress concentrations KW - Finite element analysis (FEA) Y1 - 2022 U6 - http://dx.doi.org/10.6084/m9.figshare.19333295.v2 ER - TY - JOUR A1 - Leschinger, Tim A1 - Besch, Katharina A1 - Aydin, Cansu A1 - Staat, Manfred A1 - Scaal, Martin A1 - Müller, Lars Peter A1 - Wegmann, Kilian T1 - Irreparable rotator cuff tears: a biomechanical comparison of superior capsuloligamentous complex reconstruction techniques and an interposition graft technique JF - The Orthopaedic Journal of Sports Medicine Y1 - 2019 U6 - http://dx.doi.org/10.1177/2325967119864590 VL - 7 IS - 8 SP - 1 EP - 5 ER - TY - JOUR A1 - Bhattarai, Aroj A1 - Staat, Manfred T1 - A computational study of organ relocation after laparoscopic pectopexy to repair posthysterectomy vaginal vault prolapse JF - Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization Y1 - 2019 U6 - http://dx.doi.org/10.1080/21681163.2019.1670095 SN - 2168-1171 PB - Taylor & Francis CY - London ER - TY - BOOK A1 - Staat, Manfred A1 - Heitzer, Michael T1 - Numerical methods for limit and shakedown analysis. Deterministic and probabilistic problems. Y1 - 2003 SN - 3-00-010001-6 N1 - NIC Series Vol. 15 / Ed. by Staat, M; Heitzer, M. PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - JOUR A1 - Rausch, Valentin A1 - Harbrecht, Andreas A1 - Kahmann, Stephanie Lucina A1 - Fenten, Thomas A1 - Jovanovic, Nebojsa A1 - Hackl, Michael A1 - Müller, Lars P. A1 - Staat, Manfred A1 - Wegmann, Kilian T1 - Osteosynthesis of Phalangeal Fractures: Biomechanical Comparison of Kirschner Wires, Plates, and Compression Screws JF - The Journal of Hand Surgery N2 - Purpose The aim of this study was to compare several osteosynthesis techniques (intramedullary headless compression screws, T-plates, and Kirschner wires) for distal epiphyseal fractures of proximal phalanges in a human cadaveric model. Methods A total of 90 proximal phalanges from 30 specimens (index, ring, and middle fingers) were used for this study. After stripping off all soft tissue, a transverse distal epiphyseal fracture was simulated at the proximal phalanx. The 30 specimens were randomly assigned to 1 fixation technique (30 per technique), either a 3.0-mm intramedullary headless compression screw, locking plate fixation with a 2.0-mm T-plate, or 2 oblique 1.0-mm Kirschner wires. Displacement analysis (bending, distraction, and torsion) was performed using optical tracking of an applied random speckle pattern after osteosynthesis. Biomechanical testing was performed with increasing cyclic loading and with cyclic load to failure using a biaxial torsion-tension testing machine. Results Cannulated intramedullary compression screws showed significantly less displacement at the fracture site in torsional testing. Furthermore, screws were significantly more stable in bending testing. Kirschner wires were significantly less stable than plating or screw fixation in any cyclic load to failure test setup. Conclusions Intramedullary compression screws are a highly stable alternative in the treatment of transverse distal epiphyseal phalangeal fractures. Kirschner wires seem to be inferior regarding displacement properties and primary stability. Clinical relevance Fracture fixation of phalangeal fractures using plate osteosynthesis may have the advantage of a very rigid reduction, but disadvantages such as stiffness owing to the more invasive surgical approach and soft tissue irritation should be taken into account. Headless compression screws represent a minimally invasive choice for fixation with good biomechanical properties. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.jhsa.2020.04.010 SN - 0363-5023 VL - 45 IS - 10 SP - 987.e1 EP - 987.e8 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Tran, Ngoc Trinh A1 - Staat, Manfred T1 - Direct plastic structural design under random strength and random load by chance constrained programming JF - European Journal of Mechanics - A/Solids Y1 - 2021 U6 - http://dx.doi.org/10.1016/j.euromechsol.2020.104106 SN - 0997-7538 VL - 85 IS - Article 104106 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Horbach, Andreas A1 - Staat, Manfred A1 - Perez-Viana, Daniel A1 - Simmen, Hans-Peter A1 - Neuhaus, Valentin A1 - Pape, Hans-Christoph A1 - Prescher, Andreas A1 - Ciritsis, Bernhard T1 - Biomechanical in vitro examination of a standardized low-volume tubular femoroplasty JF - Clinical Biomechanics N2 - Background Osteoporosis is associated with the risk of fractures near the hip. Age and comorbidities increase the perioperative risk. Due to the ageing population, fracture of the proximal femur also proves to be a socio-economic problem. Preventive surgical measures have hardly been used so far. Methods 10 pairs of human femora from fresh cadavers were divided into control and low-volume femoroplasty groups and subjected to a Hayes fall-loading fracture test. The results of the respective localization and classification of the fracture site, the Singh index determined by computed tomography (CT) examination and the parameters in terms of fracture force, work to fracture and stiffness were evaluated statistically and with the finite element method. In addition, a finite element parametric study with different position angles and variants of the tubular geometry of the femoroplasty was performed. Findings Compared to the control group, the work to fracture could be increased by 33.2%. The fracture force increased by 19.9%. The used technique and instrumentation proved to be standardized and reproducible with an average poly(methyl methacrylate) volume of 10.5 ml. The parametric study showed the best results for the selected angle and geometry. Interpretation The cadaver studies demonstrated the biomechanical efficacy of the low-volume tubular femoroplasty. The numerical calculations confirmed the optimal choice of positioning as well as the inner and outer diameter of the tube in this setting. The standardized minimally invasive technique with the instruments developed for it could be used in further comparative studies to confirm the measured biomechanical results. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.clinbiomech.2020.105104 VL - 80 IS - Art. 105104 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Topçu, Murat A1 - Madabhushi, Gopal S.P. A1 - Staat, Manfred T1 - A generalized shear-lag theory for elastic stress transfer between matrix and fibres having a variable radius JF - International Journal of Solids and Structures N2 - A generalized shear-lag theory for fibres with variable radius is developed to analyse elastic fibre/matrix stress transfer. The theory accounts for the reinforcement of biological composites, such as soft tissue and bone tissue, as well as for the reinforcement of technical composite materials, such as fibre-reinforced polymers (FRP). The original shear-lag theory proposed by Cox in 1952 is generalized for fibres with variable radius and with symmetric and asymmetric ends. Analytical solutions are derived for the distribution of axial and interfacial shear stress in cylindrical and elliptical fibres, as well as conical and paraboloidal fibres with asymmetric ends. Additionally, the distribution of axial and interfacial shear stress for conical and paraboloidal fibres with symmetric ends are numerically predicted. The results are compared with solutions from axisymmetric finite element models. A parameter study is performed, to investigate the suitability of alternative fibre geometries for use in FRP. KW - Natural fibres KW - Polymer-matrix composites KW - Biocomposites KW - Stress concentrations KW - Finite element analysis Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.ijsolstr.2022.111464 SN - 0020-7683 VL - 239–240 IS - Art. No. 111464 PB - Elsevier CY - New York, NY ER - TY - JOUR A1 - Defosse, Jerome A1 - Kleinschmidt, Joris A1 - Schmutz, Axel A1 - Loop, Torsten A1 - Staat, Manfred A1 - Gatzweiler, Karl-Heinz A1 - Wappler, Frank A1 - Schieren, Mark T1 - Dental strain on maxillary incisors during tracheal intubation with double-lumen tubes and different laryngoscopy techniques - a blinded manikin study JF - Journal of Cardiothoracic and Vascular Anesthesia KW - anaesthetic complications KW - dental trauma KW - difficult airway KW - double-lumen tube intubation KW - videolaryngoscopy Y1 - 2022 U6 - http://dx.doi.org/10.1053/j.jvca.2022.02.017 SN - 1053-0770 VL - 36 IS - 8, Part B SP - 3021 EP - 3027 PB - Elsevier CY - New York, NY ER - TY - JOUR A1 - Bhattarai, Aroj A1 - May, Charlotte Anabell A1 - Staat, Manfred A1 - Kowalczyk, Wojciech A1 - Tran, Thanh Ngoc T1 - Layer-specific damage modeling of porcine large intestine under biaxial tension JF - Bioengineering N2 - The mechanical behavior of the large intestine beyond the ultimate stress has never been investigated. Stretching beyond the ultimate stress may drastically impair the tissue microstructure, which consequently weakens its healthy state functions of absorption, temporary storage, and transportation for defecation. Due to closely similar microstructure and function with humans, biaxial tensile experiments on the porcine large intestine have been performed in this study. In this paper, we report hyperelastic characterization of the large intestine based on experiments in 102 specimens. We also report the theoretical analysis of the experimental results, including an exponential damage evolution function. The fracture energies and the threshold stresses are set as damage material parameters for the longitudinal muscular, the circumferential muscular and the submucosal collagenous layers. A biaxial tensile simulation of a linear brick element has been performed to validate the applicability of the estimated material parameters. The model successfully simulates the biomechanical response of the large intestine under physiological and non-physiological loads. KW - biaxial tensile experiment KW - anisotropy KW - hyperelastic KW - constitutive modeling KW - damage Y1 - 2022 U6 - http://dx.doi.org/10.3390/bioengineering9100528 SN - 2306-5354 N1 - Der Artikel gehört zum Sonderheft "Computational Biomechanics" VL - 9 IS - 10, Early Access SP - 1 EP - 17 PB - MDPI CY - Basel ER - TY - JOUR A1 - Colombo, Daniele A1 - Drira, Slah A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - An element-based formulation for ES-FEM and FS-FEM models for implementation in standard solid mechanics finite element codes for 2D and 3D static analysis JF - International Journal for Numerical Methods in Engineering N2 - Edge-based and face-based smoothed finite element methods (ES-FEM and FS-FEM, respectively) are modified versions of the finite element method allowing to achieve more accurate results and to reduce sensitivity to mesh distortion, at least for linear elements. These properties make the two methods very attractive. However, their implementation in a standard finite element code is nontrivial because it requires heavy and extensive modifications to the code architecture. In this article, we present an element-based formulation of ES-FEM and FS-FEM methods allowing to implement the two methods in a standard finite element code with no modifications to its architecture. Moreover, the element-based formulation permits to easily manage any type of element, especially in 3D models where, to the best of the authors' knowledge, only tetrahedral elements are used in FS-FEM applications found in the literature. Shape functions for non-simplex 3D elements are proposed in order to apply FS-FEM to any standard finite element. KW - distorted element KW - ES-FEM KW - FS-FEM KW - non-simplex S-FEM elements KW - S-FEM Y1 - 2022 U6 - http://dx.doi.org/10.1002/nme.7126 SN - 1097-0207 VL - 124 IS - 2 SP - 402 EP - 433 PB - Wiley CY - Chichester ER - TY - BOOK A1 - Staat, Manfred A1 - Digel, Ilya A1 - Trzewik, Jürgen A1 - Sielemann, Stefanie A1 - Erni, Daniel A1 - Zylka, Waldemar T1 - Symposium Proceedings; 4th YRA MedTech Symposium 2024 : February 1 / 2024 / FH Aachen Y1 - 2024 SN - 978-3-940402-65-3 U6 - http://dx.doi.org/10.17185/duepublico/81475 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Eschweiler, J. A1 - Laack, Walter van A1 - Staat, Manfred T1 - Elektromyographische Untersuchungen zur Kräftigung der Oberschenkelmuskulatur mit einem myoelektrischen Stimulator nach arthroskopischen Eingriffen am Kniegelenk JF - Orthopädische Praxis. 43 (2007), H. 10 Y1 - 2007 SN - 0030-588x SP - 539 EP - 542 ER - TY - JOUR A1 - Laack, Walter van A1 - Levers, A. A1 - Staat, Manfred T1 - Gonarthrosetherapie auf Kernspinresonanzbasis mit MBST-Vierjahresbeobachtungen JF - Orthopädische Nachrichten : Zeitung für Orthopädie und Unfallchirurgie. 2013, H. 7/8 Y1 - 2013 SN - 1437-2193 SP - 13 PB - Biermann CY - Köln ER - TY - JOUR A1 - Levers, A. A1 - Staat, Manfred A1 - Laack, Walter van T1 - Analyse der Langzeitwirkung der MBST® KernspinResonanzTherapie bei Gonarthrose T1 - Analysis of the Long-term Effect of the MBST® Nuclear Magnetic Resonance Therapy on Gonarthrosis N2 - Originalausgabe: Orthopädische Praxis Jg. 47. 2011 H. 11; S. 536-543. Mit freundlicher Genehmigung des Verlags Zusammenfassung: Auf der Basis von Patientenabfragen mittels Fragebogen zum Schmerzempfinden und zur Einschränkung bei Aktivitäten des alltäglichen Lebens wird die Langzeitwirkung der MBST® KernspinResonanz-Therapie bei Gonarthrose untersucht. An der Studie nahmen 39 Patienten teil, bei denen die Therapie bis zu vier Jahre zurückliegt. Neben einer Gesamtbetrachtung wird der Erfolg auch in Abhängigkeit von Alter, Geschlecht und sportlicher Aktivität analysiert. Insgesamt weist die Studie auf eine anhaltende Verbesserung des Gesundheitszustands mit zum Teil deutlicher Schmerzlinderung auch noch nach vier Jahren hin, jedoch mit einer leichten Schmerzzunahme gegen Ende des Untersuchungszeitraums von vier Jahren. Eine tendenziell positivere Wirkung bei Frauen, älteren Menschen oder auch sportlich nicht-aktiven Patienten lässt auf eine mögliche Beeinflussung des Erfolgs der Therapie durch (Über-)Belastung im Alltag schließen. Ein zusätzlich positiver Effekt der Therapie auf die Knochendichte ist ebenfalls denkbar, dies bleibt jedoch offen. N2 - Original edition: Orthopädische Praxis Vol. 47. 2011 Issue 11; P. 536-543. On the friendly authority of the publisher. Abstract: Based upon a questionnaire for patient-queries regarding pain-sensation and activity-restrictions during everyday task, the long-term effect of MBST® nuclear magnetic resonance therapy is studied in osteoarthritis of the knee. 39 patients, whose therapy dates back up to four years, participated in the study. In addition to an overall view, the success of this therapy is also analyzed regarding age, gender and physical activities. Overall, the study pointed out a sustained improvement in the patients´ local health-status with a significant pain-relief even after four years, but also with a slight increase in pain towards the end of that four-year period. There tends to be more positive effect on women, on elderly of also on even non-sports-active patients which suggest a possible influence by daily (over)-stressing on the success of the therapy. An additional positive effect of the therapy on bone density is also conceivable, however, this remains open. KW - Kniegelenkarthrose KW - Gonarthrose KW - MBST KW - Arthosetherapie KW - gonarthrosis KW - MBST KW - arthrosis therapy Y1 - 2011 ER - TY - JOUR A1 - Gorissen, P. A1 - Staat, Manfred A1 - Laack, Walter van T1 - Experimentelle Kraftmessungen als Beitrag zur Wirksamkeitsbeurteilung von Schienbeinschonern im Fußballsport T1 - Experimental measurement of forces as a contribution to evaluate the effectiveness of shin guards in soccer N2 - Diese Studie beschäftigte sich mit der Dämpfungswirkung von Schienbeinschonern, wie sie beim Fußball zum Einsatz kommen. Sie wurde mit Hilfe eines Pendelhammers durchgeführt, der verschiedene Aufschlagkräfte auf die Schoner ermöglichte. Dabei wurde deutlich, dass Schienbeinschoner die beste Wirkung bei Maximalkräften unterhalb von 5kN erreichen können, dass bei größerer Belastung allerdings Verbesserungsbedarf besteht. Hierfür konnte, u.a. durch den Einsatz neuer Materialien, ein guter Ansatzpunkt im „adäquaten Zusammenspiel von Schale und Polsterung“ der Schoner gefunden werden. Die Untersuchung hat weiterhin gezeigt, dass zumindest teilweise eine deutliche Verbesserung der Dämpfungswirkung der Schienbeinschoner in den letzten Jahren erreicht werden konnte. N2 - This study was conducted to test the damping effects of commercially available soccer shin guards on their damping effects. Therefore a pendulum impact apparatus with varying impact forces was used. It became clear that shin guards show the best effect at maximum forces of less than 5kN. There is however a need for improvement at greater impact forces. A good starting point was found in an „appropriate interaction of shell and padding” of the shin guard. It was further clarified that a significant improvement on the damping effect could be achieved at least partially over the last years. KW - Fußball KW - Schienbeinschoner KW - Aufschlagversuch Y1 - 2012 SN - 2193-5785 ER - TY - JOUR A1 - Keutmann, Sabine A1 - Staat, Manfred A1 - Laack, Walter van T1 - Untersuchung der thermischen Auswirkung von therapeutischem Ultraschall N2 - Zusammenfassung: In der Orthopädie zählt der therapeutische Ultraschall als Mittel zur Prävention und Therapiebegleitung. Er hat mechanische, thermische und physiko-chemische Auswirkungen auf den menschlichen Körper. Um mehr Erkenntnisse über die thermischen Auswirkungen zu erlangen, wurden Versuche an einem Hydrogel-Phantom und an Probanden durchgeführt. Dabei entstand eine signifikante Erwärmung des Gewebes, welche beim Probandenversuch an der Oberfläche und beim Hydrogelversuch in der Tiefe gemessen wurde. Summary: In orthopaedics, therapeutic ultrasound is a tool of prevention and therapy support. It has mechanical, thermal and physico-chemical effects on the human body. Tests with a hydrogel phantom and with human probands have been performed in order to obtain more knowledge about their thermal effects. Both tests measured temperature increases in cell tissue, on the surface with the human proband test and in depth with the hydrogel phantom test. T2 - Research about the thermal effects of therapeutic ultrasound Y1 - 2018 SN - 2193-5793 SN - 2193-5785 (Druckausgabe) VL - 7 IS - 10 SP - 518 EP - 522 PB - Deutscher Ärzte-Verl. CY - Köln ER - TY - JOUR A1 - Zhen, Manghao A1 - Liang, Yunpei A1 - Staat, Manfred A1 - Li, Quanqui A1 - Li, Jianbo T1 - Discontinuous fracture behaviors and constitutive model of sandstone specimens containing non-parallel prefabricated fissures under uniaxial compression JF - Theoretical and Applied Fracture Mechanics N2 - The deformation and damage laws of non-homogeneous irregular structural planes in rocks are the basis for studying the stability of rock engineering. To investigate the damage characteristics of rock containing non-parallel fissures, uniaxial compression tests and numerical simulations were conducted on sandstone specimens containing three non-parallel fissures inclined at 0°, 45° and 90° in this study. The characteristics of crack initiation and crack evolution of fissures with different inclinations were analyzed. A constitutive model for the discontinuous fractures of fissured sandstone was proposed. The results show that the fracture behaviors of fissured sandstone specimens are discontinuous. The stress–strain curves are non-smooth and can be divided into nonlinear crack closure stage, linear elastic stage, plastic stage and brittle failure stage, of which the plastic stage contains discontinuous stress drops. During the uniaxial compression test, the middle or ends of 0° fissures were the first to crack compared to 45° and 90° fissures. The end with small distance between 0° and 45° fissures cracked first, and the end with large distance cracked later. After the final failure, 0° fissures in all specimens were fractured, while 45° and 90° fissures were not necessarily fractured. Numerical simulation results show that the concentration of compressive stress at the tips of 0°, 45° and 90° fissures, as well as the concentration of tensile stress on both sides, decreased with the increase of the inclination angle. A constitutive model for the discontinuous fractures of fissured sandstone specimens was derived by combining the logistic model and damage mechanic theory. This model can well describe the discontinuous drops of stress and agrees well with the whole processes of the stress–strain curves of the fissured sandstone specimens. KW - Constitutive model KW - Damage mechanics theory KW - Discontinuous fractures KW - Uniaxial compression test KW - Non-parallel fissures Y1 - 2024 U6 - http://dx.doi.org/10.1016/j.tafmec.2024.104373 SN - 0167-8442 VL - 131 IS - Art. No. 104373 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Levers, A. A1 - Staat, Manfred A1 - Laack, Walter van T1 - Analysis of the long-term effect of the MBST® nuclear magnetic resonance therapy on gonarthrosis JF - Orthopedic Practice Y1 - 2016 VL - 47 IS - 11 SP - 521 EP - 528 ER - TY - JOUR A1 - Linden, A. A1 - Fischöder, M. A1 - Laack, Walter van A1 - Staat, Manfred T1 - Einschränkung von Taluskippung und -vorschub durch Sprunggelenkorthesen nach fibularer Bandruptur JF - OUP Zeitschrift für die orthopädische und unfallchirurgische Praxis N2 - Die fibulare Bandruptur zählt zu einer der am häufigsten auftretenden Verletzungen des Bewegungsapparats. In den meisten Fällen wird heute die konservativ frühfunktionelle Therapie mit Sprunggelenkorthesen allgemein bevorzugt. Im Rahmen der vorliegenden Studie wurden 14 verschiedene Sprunggelenkorthesen im Hinblick auf ihre Einschränkung von Taluskippung und Talusvorschub untersucht. Zur Simulation einer fibularen Bandruptur wurde ein Unterschenkelmodell aus Holz mit Fußteil, mit angelegten Orthesen in einen Scheuba-Halteapparat eingespannt und mit 150 N seitlich sowie anterior-posterior belastet. Anhand der erstellten "gehaltenen" Röntgenaufnahmen konnten Taluskippung und Talusvorschub jeder einzelnen Orthese eindeutig bestimmt werden. Die meisten Orthesen erreichten zufriedenstellende Ergebnisse. Es stellte sich heraus, dass vor allem eine eng anliegende, im Gelenkbereich anatomisch angepasste Form vorteilhaft zu sein scheint. N2 - The ankle sprain is actually one of the most common injuries. Nowadays the conservative pre-functional therapy with ankle braces is generally preferred. In the present study 14 different ankle braces were tested with regard to their ability to constrict the talar tilt and anterior drawer displacement. As part of the tests a wooden model of a foot was used in order to simulate an ankle sprain. This model was clamped in a Scheuba-device with different ankle braces and a force of 150 N was applied to it. The stress radiographs showed different talar tilts and anterior drawers of each brace. Most ankle braces achieved a satisfying result. It has become obvious that a tight fitting and an anatomically designed shape seem to be favourable. T2 - Constraint of talar tilt and anterior drawer by different ankle braces after the rupture of fibular ligaments KW - Sprunggelenkorthesen KW - fibulare Bandruptur KW - Distorsion des oberen Sprunggelenks KW - ankle sprain KW - rupture of the fibular ligament KW - ankle braces Y1 - 2013 SN - 2193-5785 U6 - http://dx.doi.org/10.3238/oup.2013.0306-0309 VL - 2 IS - 6 SP - 306 EP - 309 PB - Deutscher Ärzte-Verl. CY - Köln ER - TY - JOUR A1 - Nguyen, Nhu Huynh A1 - Duong, Minh Tuan A1 - Tran, Thanh Ngoc A1 - Pham, Phu Tinh A1 - Grottke, O. A1 - Tolba, R. A1 - Staat, Manfred T1 - Influence of a freeze–thaw cycle on the stress–stretch curves of tissues of porcine abdominal organs JF - Journal of Biomechanics N2 - The paper investigates both fresh porcine spleen and liver and the possible decomposition of these organs under a freeze–thaw cycle. The effect of tissue preservation condition is an important factor which should be taken into account for protracted biomechanical tests. In this work, tension tests were conducted for a large number of tissue specimens from twenty pigs divided into two groups of 10. Concretely, the first group was tested in fresh state; the other one was tested after a freeze-thaw cycle which simulates the conservation conditions before biomechanical experiments. A modified Fung model for isotropic behavior was adopted for the curve fitting of each kind of tissues. Experimental results show strong effects of the realistic freeze–thaw cycle on the capsule of elastin-rich spleen but negligible effects on the liver which virtually contains no elastin. This different behavior could be explained by the autolysis of elastin by elastolytic enzymes during the warmer period after thawing. Realistic biomechanical properties of elastin-rich organs can only be expected if really fresh tissue is tested. The observations are supported by tests of intestines. KW - Autolysis KW - Decomposition KW - Freeze–thaw process KW - Spleen KW - Liver Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jbiomech.2012.07.008 SN - 1873-2380 VL - 45 IS - 14 SP - 2382 EP - 2386 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Novacek, V. A1 - Tran, Thanh Ngoc A1 - Klinge, U. A1 - Tolba, R. H. A1 - Staat, Manfred A1 - Bronson, D. G. A1 - Miesse, A. M. A1 - Whiffen, J. A1 - Turquier, F. T1 - Finite element modelling of stapled colorectal end-to-end anastomosis : Advantages of variable height stapler design JF - Journal of Biomechanics N2 - The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge. KW - Variable height stapler design KW - Anastomotic leakage KW - Finite element modelling KW - End-to-end colorectal anastomosis KW - Surgical staplers Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jbiomech.2012.07.021 SN - 1873-2380 VL - 45 IS - 115 SP - 2693 EP - 2697 PB - Elsevier CY - Amsterdam ER -