TY - JOUR A1 - Kern, Alexander A1 - Dikta, Gerhard T1 - Bewerten von Schäden durch Blitzeinwirkungen JF - Elektropraktiker. 62 (2008), H. 4 Y1 - 2008 SN - 0013-5569 SP - 338 EP - 342 ER - TY - JOUR A1 - Kern, Alexander T1 - Überarbeitung der Blitzschutznorm IEC 62305 JF - Elektropraktiker. 63 (2009), H. 4 Y1 - 2009 SN - 0013-5569 SP - 391 EP - 394 ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Detaillierte Berechnung der Einfangwirksamkeiten von Fangeinrichtungen mit einem dynamischen elektro-geometrischen Modell - Detailed calculation of the interception efficiencies for airtermination systems using a dynamic electro-geometrical model Y1 - 2011 N1 - 9. VDE/ABB-Blitzschutztagung, Neu-Ulm 2011 SP - 1 EP - 5 ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Calculation of interception efficiencies for airterminations using a dynamic electro-geometrical model Y1 - 2011 N1 - XI International Symposium on Lightning Protection (SIPDA), Fortaleza (Brasilien), 2011. SP - 1 EP - 6 PB - IEEE CY - New York ER - TY - JOUR A1 - Landers, Ernst Ulrich A1 - Kern, Alexander T1 - Future evolution of risk management for structures : Advancement for the future IEC 62305-2 Ed3 Y1 - 2011 N1 - XI International Symposium on Lightning Protection (SIPDA), Fortaleza (Brasilien), 2011. SP - 1 EP - 6 PB - IEEE CY - New York ER - TY - JOUR A1 - Kern, Alexander A1 - Zischank, Wolfgang A1 - Beierl, Ottmar T1 - Anmerkungen zur Berechnung des Trennungsabstands nach DIN EN 62305-3 (VDE 0185-305-3): 2006-10 / Zischank, Wolfgang ; Beierl, Ottmar ; Kern, Alexander JF - 7. VDE-ABB-Blitzschutztagung : Vorträge der VDE-ABB-Fachtagung vom 15. bis 16. November 2007 in Neu-Ulm / Veranst.: Ausschuss für Blitzschutz und Blitzforschung (ABB) im VDE, Verband der Elektrotechnik, Elektronik, Informationstechnik e.V. Wiss. Tagungsltg.: K. Stimper Y1 - 2007 SN - 978-3-8007-3062-9 N1 - VDE-Fachbericht ; 64 ; Blitzschutztagung <7, 2007, Neu-Ulm> SP - 1 EP - 8 PB - VDE-Verl. CY - Berlin ER - TY - JOUR A1 - Kern, Alexander A1 - Dikta, Gerhard A1 - Krichel, Frank T1 - Zur Wahrscheinlichkeit für Schäden an elektrischen und elektronischen Einrichtungen durch indirekte Blitzeinschläge - Auswertung von Schadensstatistiken, analytischen und numerischen Berechnungen JF - 7. VDE-ABB-Blitzschutztagung : Vorträge der VDE-ABB-Fachtagung vom 15. bis 16. November 2007 in Neu-Ulm / Veranst.: Ausschuss für Blitzschutz und Blitzforschung (ABB) im VDE, Verband der Elektrotechnik, Elektronik, Informationstechnik e.V. Wiss. Tagungsltg.: K. Stimper Y1 - 2007 SN - 978-3-8007-3062-9 N1 - VDE-Fachbericht ; 64 ; Blitzschutztagung <7, 2007, Neu-Ulm> SP - 1 EP - 9 PB - VDE-Verl. CY - Berlin ER - TY - JOUR A1 - Kern, Alexander A1 - Landers, E.-U. A1 - Scheibe, K. A1 - Zahlmann, P. T1 - Die künftige deutsche Blitzschutznormung (1) : Reihe DIN EN 62305 / VDE 0185-305-x:2006 JF - De : der Elektro- und Gebäudetechniker / Ausgabe ZV. 81 (2006), H. 15-16 Y1 - 2006 SN - 1617-1160 N1 - In der Bibliothek vorhanden: 23 Z 863 (Bibliothek Eupener Str.) SP - 26 EP - 30 ER - TY - JOUR A1 - Kern, Alexander A1 - Heidler, F. A1 - Zischank, W. T1 - Induced overvoltages in cable ducts taking into account the current flow into earth / F. Heidler ; W. Zischank ... A. Kern ... JF - Conference proceedings : 14th - 18th September 1998, [Burlington Hotel, Birmingham, United Kingdom] / organised by: School of Engineering and Advanced Technology, Staffordshire University, United Kingdom Y1 - 1998 N1 - International Conference on Lightning Protection <24, 1998, Birmingham> ; School of Engineering and Advanced Technology ; ICLP <4, 1998, Birmingham> CY - Birmingham ER - TY - JOUR A1 - Kern, Alexander A1 - Braun, Christian T1 - Neuerungen bei der Blitzschutznorm. Teil 2 JF - etz Elektrotechnik und Automation Y1 - 2013 SN - 0170-1711 N1 - Printausg. in der Bibliothek der FH Aachen vorhanden: 23 Z 133 ; 63 ZS 035 VL - Bd. 134 IS - H. 8 SP - 66 EP - 69 PB - VDE-Verlag CY - Wuppertal ER - TY - CHAP A1 - Kern, Alexander T1 - Die neue DIN EN 62305-2 (VDE 0185-305-2) Ed.2:2013-02 - Änderungen zur Ed.l und zugehörige Beiblätter T2 - 10. VDE, VBB-Blitzschutztagung : Vorträge der 10. VDE, ABB-Fachtagung vom 24. bis 25. Oktober 2013 in Neu-Ulm. (VDE-Fachbericht ; 70) Y1 - 2013 SN - 978-3-8007-3540-2 SP - 9 EP - 16 PB - VDE-Verl. CY - Berlin ER - TY - CHAP A1 - Scheibe, K. A1 - Kern, Alexander T1 - Stand der Normung für Überspannungsschutzgeräte T2 - 10. VDE, VBB-Blitzschutztagung : Vorträge der 10. VDE, ABB-Fachtagung vom 24. bis 25. Oktober 2013 in Neu-Ulm. (VDE-Fachbericht ; 70) Y1 - 2013 SN - 978-3-8007-3540-2 SP - 23 EP - 27 PB - VDE-Verl. CY - Berlin ER - TY - CHAP A1 - Wetter, Martin A1 - Kern, Alexander T1 - Number of lightning strikes to tall structures - comparison of calculations and measurements using a modern lightning monitoring system T2 - 2014 International Conference on Lightning Protection (ICLP), Shanghai, China Y1 - 2014 SP - 1 EP - 7 ER - TY - CHAP A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Calculation of interception efficiencies for mesh-type air-terminations according to IEC 62305-3 using a dynamic electro-geometrical model T2 - International Conference on Lightning Protection (ICLP) : 2 - 7 Sept. 2012, Vienna Y1 - 2012 SN - 978-1-4673-1896-9 (E-Book) ; 978-1-4673-1898-3 (Print) SP - 1 EP - 6 PB - IEEE CY - Piscataway, NJ ER - TY - CHAP A1 - Lo Piparo, G. B. A1 - Kern, Alexander A1 - Mazzetti, C. T1 - Some masterpoints about risk due to lightning T2 - International Conference on Lightning Protection (ICLP) : 2 - 7 Sept. 2012, Vienna Y1 - 2012 SN - 978-1-4673-1896-9 (E-Book) ; 978-1-4673-1898-3 (Print) SP - 1 EP - 6 PB - IEEE CY - Piscataway, NJ ER - TY - CHAP A1 - Rousseau, Alain A1 - Kern, Alexander T1 - How to deal with environmental risk in IEC 62305-2 T2 - 2014 International Conference on Lightning Protection (ICLP), Shanghai, China N2 - The 2nd edition of the lightning risk management standard (IEC 62305-2) considers structures, which may endanger environment. In these cases, the loss is not limited to the structure itself, which is valid for usual structures. In the past (Edition 1) this danger was simply taken into account by a special hazard factor, multiplying the existing risk for the structure with a number. Now, in the edition 2, we add to the risk for the structure itself a “second risk” due to the losses outside the structure. The losses outside can be treated independently from what occurs inside. This is a major advantage to analyze the risk for sensitive structures, like chemical plants, nuclear plants, or structures containing explosives, etc. In this paper, the existing procedure given by the European version EN 62305-2 Ed.2 is further developed and applied to a few structures. Y1 - 2014 SP - 521 EP - 527 ER - TY - CHAP A1 - Kern, Alexander A1 - Braun, Christian T1 - Risk management according to IEC 62305-2 edition 2: 2010–12 assessment of structures with a risk of explosion T2 - 2014 International Conference on Lightning Protection (ICLP), Shanghai, China N2 - Risk management for structures with a risk of explosion should be considered very carefully when performing a risk analysis according to IEC 62305-2. In contrast to the 2006 edition of the standard, the 2010 edition describes the topic “Structures with a risk of explosion” in more detail. Moreover, in Germany separate procedures and parameters are defined for the risk analysis of structures with a risk of explosion (Supplement 3 of the German DIN EN 62305-2 standard). This paper describes the contents and the relevant calculations of this Supplement 3, together with a numerical example. Y1 - 2014 SP - 1237 EP - 1242 ER - TY - BOOK A1 - Kern, Alexander A1 - Wettingfeld, Jürgen T1 - Blitzschutzsysteme 1 : allgemeine Grundsätze, Risikomanagement, Schutz von baulichen Anlagen und Personen ; Erläuterungen zu den Normen DIN EN 62305-1 (VDE 0185-305-1):2011-10, DIN EN 62305-2 (VDE 0185-305-2):2013-02, DIN EN 62305-3 (VDE 0185-305-3):2011-10. (VDE-Schriftenreihe Normen verständlich ; 44) Y1 - 2014 SN - 978-3-8007-3511-2 PB - VDE-Verl. CY - Berlin [u.a.] ER - TY - BOOK A1 - Kern, Alexander A1 - Wettingfeld, Jürgen T1 - Blitzschutzsysteme 2 : Schutz für besondere bauliche Anlagen ; Schutz für elektrische und elektronische Systeme in baulichen Anlagen ; Erläuterungen zu den Normen DIN EN 62305-3 (VDE 0185-305-3):2011-10, DIN EN 62305-4 (VDE 0185-305-4):2011-10. (VDE-Schriftenreihe Normen verständlich ; 160) Y1 - 2015 SN - 978-3-8007-3653-9 PB - VDE-Verl. CY - Berlin [u.a.] ER - TY - JOUR A1 - Kern, Alexander T1 - Blitz- und Überspannungsschutz von Kernkraftwerken - Nachweisführung der ausreichenden Sicherheit für leittechnische Einrichtungen auch bei Blitzeinschlägen mit extremen Parametern JF - Atw. International Journal for Nuclear Power N2 - Für das Auftreten extremer Wetterereignisse werden für Kernkraftwerke Eintrittshäufigkeiten für nicht mehr beherrschbare Zustände von unter 10⁻⁴/a gefordert. Dies gilt auch für die Einwirkung von Blitzeinschlägen. Die bisherige Nachweisführung zu Blitz- und Überspannungsschutz eines KKW in Deutschland ist deterministisch. In diesem Bericht werden das Vorgehen für einen entsprechenden Nachweis für leittechnische Einrichtungen der Sicherheitstechnik von KKW, der zur geforderten Zielgröße der Eintrittshäufigkeit führt. Die Ergebnisse werden zusammenfassend bewertet. Y1 - 2016 SN - 1431-5254 VL - 61 IS - 8/9 SP - 534 EP - 543 PB - Inforum CY - Berlin ER -