TY - JOUR A1 - Thust, M. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Naser, S. A1 - Müller-Veggian, Mattea A1 - Kordos, P. A1 - Lüth, H. T1 - Crosssensitivity of a capacitive penicillin sensor combined with a diffusion barrier JF - Proceedings : The Hague, The Netherlands, September 12 - 15, 1999 / [ed. by M. Bartek]. Vol 1. Y1 - 1999 SN - 90-76699-02-X N1 - Eurosensors ; (13, 1999, 's-Gravenhage) ; Eurosensors ; (13 : ; 1999.09.12-15 : ; The Hague) ; European Conference on Solid-State Transducers ; (13 : ; 1999.09.12-15 : ; The Hague) SP - 573 EP - 576 CY - The Hague, The Netherlands ER - TY - CHAP A1 - Poghossian, Arshak A1 - Ingebrandt, S. A1 - Platen, J. A1 - Schöning, Michael Josef T1 - Field-effect sensors with charged macromolecules – from micro towards nano aspects T2 - Biochemical Sensing Utilisation of Micro-and Nanotechnologies, Warschau, Nov. 2005 : Lecture Notes of the ICB Seminar / ed.: M. Mascini, W. Torbicz Y1 - 2006 SP - 74 EP - 81 PB - Polish Academy Sciences Press CY - Warsaw ER - TY - JOUR A1 - Poghossian, Arshak A1 - Jablonski, Melanie A1 - Koch, Claudia A1 - Bronder, Thomas A1 - Rolka, David A1 - Wege, Christina A1 - Schöning, Michael Josef T1 - Field-effect biosensor using virus particles as scaffolds for enzyme immobilization JF - Biosensors and Bioelectronics N2 - A field-effect biosensor employing tobacco mosaic virus (TMV) particles as scaffolds for enzyme immobilization is presented. Nanotubular TMV scaffolds allow a dense immobilization of precisely positioned enzymes with retained activity. To demonstrate feasibility of this new strategy, a penicillin sensor has been developed by coupling a penicillinase with virus particles as a model system. The developed field-effect penicillin biosensor consists of an Al-p-Si-SiO₂-Ta₂O₅-TMV structure and has been electrochemically characterized in buffer solutions containing different concentrations of penicillin G. In addition, the morphology of the biosensor surface with virus particles was characterized by scanning electron microscopy and atomic force microscopy methods. The sensors possessed a high penicillin sensitivity of ~ 92 mV/dec in a nearly-linear range from 0.1 mM to 10 mM, and a low detection limit of about 50 µM. The long-term stability of the penicillin biosensor was periodically tested over a time period of about one year without any significant loss of sensitivity. The biosensor has also been successfully applied for penicillin detection in bovine milk samples. Y1 - 2018 U6 - https://doi.org/10.1016/j.bios.2018.03.036 SN - 0956-5663 VL - 110 SP - 168 EP - 174 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bäcker, Matthias A1 - Schusser, Sebastian A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Multi-Parametererfassung mit siliziumbasiertem Sensorchip: Aus Drei mach Eins JF - GIT Labor-Fachzeitschrift Y1 - 2014 SN - 0016-3538 IS - 2 SP - 28 EP - 30 PB - Wiley ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak A1 - Schultze, J. W. A1 - Lüth, H. T1 - Field-effect based multifunctional hybrid sensor module for the determination of both (bio-)chemical and physical paramters JF - Proceedings of SPIE. 4576 (2002) Y1 - 2002 SP - 149 EP - 159 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Berndsen, L. A1 - Schöning, Michael Josef T1 - Chemical sensor as a physical sensor: ISFET-based flowvelocity, flow-direction and diffusion-coefficient sensor JF - Book of abstracts / ed. by J. Saneistr. Y1 - 2002 SN - 80-01-02576-4 N1 - Eurosensors ; (16, 2002, Praha) SP - 649 EP - 652 PB - Czech Technical University, Faculty of Electrical Engineering, Department of Measurement CY - Prague ER - TY - JOUR A1 - Näther, Niko A1 - Auger, V. A1 - Poghossian, Arshak A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - A miniaturized flow-through cell in SU-8 technique for EIS sensors JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 994 EP - 995 ER - TY - CHAP A1 - Poghossian, Arshak A1 - Weiland, Maryam A1 - Schöning, Michael Josef ED - Lvova, Larisa ED - Kirsanov, Dmitry ED - di Natale, Corrado ED - Legin, Audrey T1 - Nanoplate field-effect capacitors: a new transducer structure for multiparameter (bio-)chemical sensing T2 - Multisensor system for chemical analysis : materials and sensors N2 - An array of electrically isolated nanoplate field-effect silicon-on-insulator (SOI) capacitors as a new transducer structure for multiparameter (bio-)chemical sensing is presented. The proposed approach allows addressable biasing and electrical readout of multiple nanoplate field-effect capacitive (bio-)chemical sensors on the same SOI chip, as well as differential-mode measurements. The realized sensor chip has been applied for pH and penicillin concentration measurements, electrical monitoring of polyelectrolyte multilayer formation, and the label-free electrical detection of consecutive deoxyribonucleic acid (DNA) hybridization and denaturation events. Y1 - 2014 SN - 978-981-4411-15-8 ; 978-981-4411-16-5 U6 - https://doi.org/10.1201/b15491-11 SP - 333 EP - 373 PB - Jenny Stanford Publishing CY - Singapore ET - 1 ER - TY - JOUR A1 - Buniatyan, V. A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Aroutiounian, V. M. A1 - Schöning, Michael Josef T1 - BaxSr1-x TiO3/pc-Si heterojunction capacitance JF - Armenian journal of physics Y1 - 2013 SN - 1829-1171 VL - 6 IS - 4 SP - 188 EP - 197 PB - National Academy of Sciences of Armenia CY - Yerevan ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak A1 - Schultze, Joachim W. T1 - Measuring seven parameters by two ISFET modules in a microcell set-up JF - Int. Journal of Computational Engineering Science. 4 (2003), H. 2 Y1 - 2003 SN - 1465-8763 SP - 257 EP - 260 ER - TY - CHAP A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Schöning, Michael Josef ED - Abdelghani, Adnane ED - Schöning, Michael Josef T1 - (Bio-­)chemical sensor array based on nanoplate SOI capacitors T2 - Nanoscale Science and Technology (NS&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012 Y1 - 2012 SP - 31 EP - 31 ER - TY - JOUR A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Reisert, Steffen A1 - Kramer, Friederike A1 - Begoyan, Vardges K. A1 - Buniatyan, Vahe V. A1 - Schöning, Michael Josef T1 - Multi-parameter sensing using high-k oxide of barium strontium titanate JF - Physica status solidi (a) N2 - High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors. In this work, a Si-based sensor chip containing Pt interdigitated electrodes covered with a thin BST layer (485 nm) has been developed for multi-parameter chemical sensing. The chip has been applied for the contactless measurement of the electrolyte conductivity, the detection of adsorbed charged macromolecules (positively charged polyelectrolytes of polyethylenimine) and the concentration of hydrogen peroxide (H2O2) vapor. The experimental results of functional testing of individual sensors are presented. The mechanism of the BST sensitivity to charged polyelectrolytes and H2O2 vapor has been proposed and discussed. Y1 - 2015 U6 - https://doi.org/10.1002/pssa.201431911 SN - 1862-6319 VL - 212 IS - 6 SP - 1259 PB - Wiley CY - Weinheim ER - TY - CHAP A1 - Schusser, Sebastian A1 - Leinhos, Marcel A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef ED - Abdelghani, Adnane ED - Schöning, Michael Josef T1 - Biopolymer-degradation monitoring by chip-­based impedance spectroscopy technique T2 - Nanoscale Science and Technology (NS&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012 Y1 - 2012 SP - 47 EP - 47 ER - TY - JOUR A1 - Karschuck, Tobias A1 - Schmidt, Stefan A1 - Achtsnicht, Stefan A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Multiplexing system for automated characterization of a capacitive field-effect sensor array JF - Physica Status Solidi A N2 - In comparison to single-analyte devices, multiplexed systems for a multianalyte detection offer a reduced assay time and sample volume, low cost, and high throughput. Herein, a multiplexing platform for an automated quasi-simultaneous characterization of multiple (up to 16) capacitive field-effect sensors by the capacitive–voltage (C–V) and the constant-capacitance (ConCap) mode is presented. The sensors are mounted in a newly designed multicell arrangement with one common reference electrode and are electrically connected to the impedance analyzer via the base station. A Python script for the automated characterization of the sensors executes the user-defined measurement protocol. The developed multiplexing system is tested for pH measurements and the label-free detection of ligand-stabilized, charged gold nanoparticles. KW - Capacitive field-effect sensor KW - Gold nanoparticles KW - Label-free detection KW - Multicell KW - Multiplexing Y1 - 2023 U6 - https://doi.org/10.1002/pssa.202300265 SN - 1862-6300 (Print) SN - 1862-6319 (Online) N1 - Corresponding author: Michael Josef Schöning VL - 220 IS - 22 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Wendlandt, Tim A1 - Koch, Claudia A1 - Britz, Beate A1 - Liedek, Anke A1 - Schmidt, Nora A1 - Werner, Stefan A1 - Gleba, Yuri A1 - Vahidpour, Farnoosh A1 - Welden, Melanie A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Facile Purification and Use of Tobamoviral Nanocarriers for Antibody-Mediated Display of a Two-Enzyme System JF - Viruses N2 - Immunosorbent turnip vein clearing virus (TVCV) particles displaying the IgG-binding domains D and E of Staphylococcus aureus protein A (PA) on every coat protein (CP) subunit (TVCVPA) were purified from plants via optimized and new protocols. The latter used polyethylene glycol (PEG) raw precipitates, from which virions were selectively re-solubilized in reverse PEG concentration gradients. This procedure improved the integrity of both TVCVPA and the wild-type subgroup 3 tobamovirus. TVCVPA could be loaded with more than 500 IgGs per virion, which mediated the immunocapture of fluorescent dyes, GFP, and active enzymes. Bi-enzyme ensembles of cooperating glucose oxidase and horseradish peroxidase were tethered together on the TVCVPA carriers via a single antibody type, with one enzyme conjugated chemically to its Fc region, and the other one bound as a target, yielding synthetic multi-enzyme complexes. In microtiter plates, the TVCVPA-displayed sugar-sensing system possessed a considerably increased reusability upon repeated testing, compared to the IgG-bound enzyme pair in the absence of the virus. A high coverage of the viral adapters was also achieved on Ta2O5 sensor chip surfaces coated with a polyelectrolyte interlayer, as a prerequisite for durable TVCVPA-assisted electrochemical biosensing via modularly IgG-assembled sensor enzymes. KW - biosensor KW - horseradish peroxidase (HRP) KW - glucose oxidase (GOx) KW - enzyme cascade KW - turnip vein clearing virus (TVCV) KW - tobacco mosaic virus (TMV) Y1 - 2023 U6 - https://doi.org/doi.org/10.3390/v15091951 SN - 1999-4915 N1 - This article belongs to the Special Issue "Tobamoviruses 2023" VL - 9 IS - 15 PB - MDPI CY - Basel ER -