TY - JOUR A1 - Frank, T. A1 - Buchwald, D. A1 - Pennekamp, W. A1 - Reber, D. A1 - Sponagel, Stefan A1 - Laszkovics, A. A1 - Weber, Hans-Joachim T1 - Röntgenologische Untersuchung der Strömungseigenschaften funktioneller Komponenten der Herz-Lungen-Maschine JF - Kardiotechnik. 18 (2009), H. 2 Y1 - 2009 SN - 0941-2670 N1 - gedruckt in der Bibliothek unter der Signatur 63 Z 629 SP - 31 EP - 35 ER - TY - JOUR A1 - Hartung, Frank A1 - Rey, J. A1 - Mathieu, B. A1 - Lozano, D. T1 - Media aware overlay routing in Ambient Networks / Rey, J. ; Mathieu, B. ; Lozano, D. ; Herborn, S. ; Ahmed, K. ; Schmid, S. ; Goebbels, S. ; Hartung, F. ; Kampmann, M. JF - 16th IEEE International Symposium on Personal, Indoor and Mobile Radio Communications, 2005. PIMRC 2005. Date:11-14 Sept. 2005 ; Vol. 2 Y1 - 2004 SP - 952 EP - 957 ER - TY - BOOK A1 - Breitbach, Gerd A1 - Frank, D. A1 - Schubert, F. T1 - Bestimmung des Verformungs- und Versagensverhaltens von stengelkristallinen Gasturbinenschaufeln aus IN 792 DS / D. Frank ; F. Schubert ; G. Breitbach ... Y1 - 1996 N1 - Zugl.: Aachen, Techn. Hochsch., Diss. , 1996. - (Berichte des Forschungszentrums Jülich ; 3315). - Report-Nr.: Jül 3315 PB - Forschungszentrum Jülich, Zentralbibliothek CY - Jülich ER - TY - JOUR A1 - Dieringer, Matthias A. A1 - Renz, Wolfgang A1 - Lindel, Tomasz D. A1 - Seifert, Frank A1 - Frauenrath, Tobias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Waiczies, Helmar A1 - Hoffmann, Werner A1 - Rieger, Jan A1 - Pfeiffer, Harald A1 - Ittermann, Bernd A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Design and application of a four-channel transmit/receive surface coil for functional cardiac imaging at 7T JF - Journal of Magnetic Resonance Imaging N2 - Purpose To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T. Materials and Methods A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3. Results Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach. Conclusion A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated. Y1 - 2011 U6 - https://doi.org/10.1002/jmri.22451 SN - 1522-2586 VL - 33 IS - 3 SP - 736 EP - 741 PB - Wiley-Liss CY - New York ER -