TY - JOUR A1 - Molinnus, Denise A1 - Hardt, Gabriel A1 - Siegert, Petra A1 - Willenberg, Holger S. A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Detection of Adrenaline in Blood Plasma as Biomarker for Adrenal Venous Sampling JF - Electroanalysis N2 - An amperometric bi-enzyme biosensor based on substrate recycling principle for the amplification of the sensor signal has been developed for the detection of adrenaline in blood. Adrenaline can be used as biomarker verifying successful adrenal venous sampling procedure. The adrenaline biosensor has been realized via modification of a galvanic oxygen sensor with a bi-enzyme membrane combining a genetically modified laccase and a pyrroloquinoline quinone-dependent glucose dehydrogenase. The measurement conditions such as pH value and temperature were optimized to enhance the sensor performance. A high sensitivity and a low detection limit of about 0.5–1 nM adrenaline have been achieved in phosphate buffer at pH 7.4, relevant for measurements in blood samples. The sensitivity of the biosensor to other catecholamines such as noradrenaline, dopamine and dobutamine has been studied. Finally, the sensor has been successfully applied for the detection of adrenaline in human blood plasma. Y1 - 2018 U6 - http://dx.doi.org/10.1002/elan.201800026 SN - 1521-4109 VL - 30 IS - 5 SP - 937 EP - 942 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Oberländer, Jan A1 - Mayer, Marlena A1 - Greeff, Anton A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Spore-based biosensor to monitor the microbicidal efficacy of gaseous hydrogen peroxide sterilization processes JF - Biosensors and Bioelectronics N2 - In this work, a spore-based biosensor is evaluated to monitor the microbicidal efficacy of sterilization processes applying gaseous hydrogen peroxide (H2O2). The sensor is based on interdigitated electrode structures (IDEs) that have been fabricated by means of thin-film technologies. Impedimetric measurements are applied to study the effect of sterilization process on spores of Bacillus atrophaeus. This resilient microorganism is commonly used in industry to proof the sterilization efficiency. The sensor measurements are accompanied by conventional microbiological challenge tests, as well as morphological characterizations with scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The sensor measurements are correlated with the microbiological test routines. In both methods, namely the sensor-based and microbiological one, a tailing effect has been observed. The results are evaluated and discussed in a three-dimensional calibration plot demonstrating the sensor's suitability to enable a rapid process decision in terms of a successfully performed sterilization. Y1 - 2018 U6 - http://dx.doi.org/10.1016/j.bios.2017.12.045 SN - 0956-5663 VL - 104 SP - 87 EP - 94 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Molinnus, Denise A1 - Muschallik, Lukas A1 - Gonzalez, Laura Osorio A1 - Bongaerts, Johannes A1 - Wagner, Torsten A1 - Selmer, Thorsten A1 - Siegert, Petra A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Development and characterization of a field-effect biosensor for the detection of acetoin JF - Biosensors and Bioelectronics N2 - A capacitive electrolyte-insulator-semiconductor (EIS) field-effect biosensor for acetoin detection has been presented for the first time. The EIS sensor consists of a layer structure of Al/p-Si/SiO₂/Ta₂O₅/enzyme acetoin reductase. The enzyme, also referred to as butane-2,3-diol dehydrogenase from B. clausii DSM 8716T, has been recently characterized. The enzyme catalyzes the (R)-specific reduction of racemic acetoin to (R,R)- and meso-butane-2,3-diol, respectively. Two different enzyme immobilization strategies (cross-linking by using glutaraldehyde and adsorption) have been studied. Typical biosensor parameters such as optimal pH working range, sensitivity, hysteresis, linear concentration range and long-term stability have been examined by means of constant-capacitance (ConCap) mode measurements. Furthermore, preliminary experiments have been successfully carried out for the detection of acetoin in diluted white wine samples. Y1 - 2018 U6 - http://dx.doi.org/10.1016/j.bios.2018.05.023 VL - 115 SP - 1 EP - 6 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Molinnus, Denise A1 - Hardt, G. A1 - Käver, L. A1 - Willenberg, H.S. A1 - Kröger, J.-C. A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Chip-based biosensor for the detection of low adrenaline concentrations to support adrenal venous sampling JF - Sensor and Actuators B: Chemical N2 - A chip-based amperometric biosensor referring on using the bioelectrocatalytical amplification principle for the detection of low adrenaline concentrations is presented. The adrenaline biosensor has been prepared by modification of a platinum thin-film electrode with an enzyme membrane containing the pyrroloquinoline quinone-dependent glucose dehydrogenase and glutaraldehyde. Measuring conditions such as temperature, pH value, and glucose concentration have been optimized to achieve a high sensitivity and a low detection limit of about 1 nM adrenaline measured in phosphate buffer at neutral pH value. The response of the biosensor to different catecholamines has also been proven. Long-term stability of the adrenaline biosensor has been studied over 10 days. In addition, the biosensor has been successfully applied for adrenaline detection in human blood plasma for future biomedical applications. Furthermore, preliminary experiments have been carried to detect the adrenaline-concentration difference measured in peripheral blood and adrenal venous blood, representing the adrenal vein sampling procedure of a physician. Y1 - 2018 U6 - http://dx.doi.org/10.1016/j.snb.2018.05.136 SN - 0925-4005 VL - 272 SP - 21 EP - 27 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bronder, Thomas A1 - Jessing, Max P. A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Detection of PCR-Amplified Tuberculosis DNA Fragments with Polyelectrolyte-Modified Field-Effect Sensors JF - Analytical Chemistry N2 - Field-effect-based electrolyte-insulator-semiconductor (EIS) sensors were modified with a bilayer of positively charged weak polyelectrolyte (poly(allylamine hydrochloride) (PAH)) and probe single-stranded DNA (ssDNA) and are used for the detection of complementary single-stranded target DNA (cDNA) in different test solutions. The sensing mechanism is based on the detection of the intrinsic molecular charge of target cDNA molecules after the hybridization event between cDNA and immobilized probe ssDNA. The test solutions contain synthetic cDNA oligonucleotides (with a sequence of tuberculosis mycobacteria genome) or PCR-amplified DNA (which origins from a template DNA strand that has been extracted from Mycobacterium avium paratuberculosis-spiked human sputum samples), respectively. Sensor responses up to 41 mV have been measured for the test solutions with DNA, while only small signals of ∼5 mV were detected for solutions without DNA. The lower detection limit of the EIS sensors was ∼0.3 nM, and the sensitivity was ∼7.2 mV/decade. Fluorescence experiments using SybrGreen I fluorescence dye support the electrochemical results. Y1 - 2018 U6 - http://dx.doi.org/10.1021/acs.analchem.8b01807 SN - 0003-2700 VL - 90 IS - 12 SP - 7747 EP - 7753 PB - ACS Publications CY - Washington, DC ER - TY - JOUR A1 - Jildeh, Zaid B. A1 - Oberländer, Jan A1 - Kirchner, Patrick A1 - Keusgen, Michael A1 - Wagner, Patrick H. A1 - Schöning, Michael Josef T1 - Experimental and Numerical Analyzes of a Sensor Based on Interdigitated Electrodes for Studying Microbiological Alterations JF - physica status solidi (a): applications and materials science N2 - In this work, a cell-based biosensor to evaluate the sterilization efficacy of hydrogen peroxide vapor sterilization processes is characterized. The transducer of the biosensor is based on interdigitated gold electrodes fabricated on an inert glass substrate. Impedance spectroscopy is applied to evaluate the sensor behavior and the alteration of test microorganisms due to the sterilization process. These alterations are related to changes in relative permittivity and electrical conductivity of the bacterial spores. Sensor measurements are conducted with and without bacterial spores (Bacillus atrophaeus), as well as after an industrial sterilization protocol. Equivalent two-dimensional numerical models based on finite element method of the periodic finger structures of the interdigitated gold electrodes are designed and validated using COMSOL® Multiphysics software by the application of known dielectric properties. The validated models are used to compute the electrical properties at different sensor states (blank, loaded with spores, and after sterilization). As a final result, we will derive and tabulate the frequency-dependent electrical parameters of the spore layer using a novel model that combines experimental data with numerical optimization techniques. Y1 - 2018 U6 - http://dx.doi.org/10.1002/pssa.201700920 SN - 1862-6319 VL - 215 IS - 15 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Röhlen, Desiree A1 - Pilas, Johanna A1 - Dahmen, Markus A1 - Keusgen, Michael A1 - Selmer, Thorsten A1 - Schöning, Michael Josef T1 - Toward a Hybrid Biosensor System for Analysis of Organic and Volatile Fatty Acids in Fermentation Processes JF - Frontiers in Chemistry N2 - Monitoring of organic acids (OA) and volatile fatty acids (VFA) is crucial for the control of anaerobic digestion. In case of unstable process conditions, an accumulation of these intermediates occurs. In the present work, two different enzyme-based biosensor arrays are combined and presented for facile electrochemical determination of several process-relevant analytes. Each biosensor utilizes a platinum sensor chip (14 × 14 mm²) with five individual working electrodes. The OA biosensor enables simultaneous measurement of ethanol, formate, d- and l-lactate, based on a bi-enzymatic detection principle. The second VFA biosensor provides an amperometric platform for quantification of acetate and propionate, mediated by oxidation of hydrogen peroxide. The cross-sensitivity of both biosensors toward potential interferents, typically present in fermentation samples, was investigated. The potential for practical application in complex media was successfully demonstrated in spiked sludge samples collected from three different biogas plants. Thereby, the results obtained by both of the biosensors were in good agreement to the applied reference measurements by photometry and gas chromatography, respectively. The proposed hybrid biosensor system was also used for long-term monitoring of a lab-scale biogas reactor (0.01 m³) for a period of 2 months. In combination with typically monitored parameters, such as gas quality, pH and FOS/TAC (volatile organic acids/total anorganic carbonate), the amperometric measurements of OA and VFA concentration could enhance the understanding of ongoing fermentation processes. Y1 - 2018 U6 - http://dx.doi.org/10.3389/fchem.2018.00284 IS - 6 PB - Frontiers CY - Lausanne ER - TY - JOUR A1 - Arreola, Julio A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Toward an immobilization method for spore-based biosensors in oxidative environment JF - Electrochimica Acta Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.electacta.2019.01.148 VL - 302 SP - 394 EP - 401 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bronder, Thomas A1 - Poghossian, Arshak A1 - Jessing, Max P. A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Surface regeneration and reusability of label-free DNA biosensors based on weak polyelectrolyte-modified capacitive field-effect structures JF - Biosensors and Bioelectronics Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.bios.2018.11.019 SN - 0956-5663 VL - 126 SP - 510 EP - 517 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Cornelis, Peter A1 - Givanoudi, Stella A1 - Yongabi, Derick A1 - Iken, Heiko A1 - Duwé, Sam A1 - Deschaume, Olivier A1 - Robbens, Johan A1 - Dedecker, Peter A1 - Bartic, Carmen A1 - Wübbenhorst, Michael A1 - Schöning, Michael Josef A1 - Heyndrickx, Marc A1 - Wagner, Patrick T1 - Sensitive and specific detection of E. coli using biomimetic receptors in combination with a modified heat-transfer method JF - Biosensors and Bioelectronics Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.bios.2019.04.026 SN - 0956-5663 VL - 136 SP - 97 EP - 105 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Arreola, Julio A1 - Keusgen, Michael A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Combined calorimetric gas- and spore-based biosensor array for online monitoring and sterility assurance of gaseous hydrogen peroxide in aseptic filling machines JF - Biosensors and Bioelectronics Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.bios.2019.111628 SN - 0956-5663 VL - 143 IS - 111628 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Welden, Melanie A1 - Severins, Robin A1 - Poghossian, Arshak A1 - Wege, Christina A1 - Siegert, Petra A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Studying the immobilization of acetoin reductase with Tobacco mosaic virus particles on capacitive field-effect sensors T2 - 2022 IEEE International Symposium on Olfaction and Electronic Nose (ISOEN) N2 - A capacitive electrolyte-insulator-semiconductor (EISCAP) biosensor modified with Tobacco mosaic virus (TMV) particles for the detection of acetoin is presented. The enzyme acetoin reductase (AR) was immobilized on the surface of the EISCAP using TMV particles as nanoscaffolds. The study focused on the optimization of the TMV-assisted AR immobilization on the Ta 2 O 5 -gate EISCAP surface. The TMV-assisted acetoin EISCAPs were electrochemically characterized by means of leakage-current, capacitance-voltage, and constant-capacitance measurements. The TMV-modified transducer surface was studied via scanning electron microscopy. KW - Tobacco mosaic virus KW - acetoin KW - capacitive field-effect biosensor KW - enzyme immobilization Y1 - 2022 SN - 978-1-6654-5860-3 (Online) SN - 978-1-6654-5861-0 (Print) U6 - http://dx.doi.org/10.1109/ISOEN54820.2022.9789657 N1 - IEEE International Symposium on Olfaction and Electronic Nose (ISOEN), 29 May 2022 - 01 June 2022, Aveiro, Portugal. PB - IEEE ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Bronder, Thomas A1 - Wu, Chunsheng A1 - Scheja, Sabrina A1 - Jessing, Max A1 - Metzger-Boddien, Christoph A1 - Keusgen, Michael A1 - Poghossian, Arshak T1 - Label-Free DNA Detection with Capacitive Field-Effect Devices—Challenges and Opportunities JF - Proceedings N2 - Field-effect EIS (electrolyte-insulator-semiconductor) sensors modified with a positively charged weak polyelectrolyte layer have been applied for the electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge. The EIS sensors are able to detect the existence of target DNA amplicons in PCR (polymerase chain reaction) samples and thus, can be used as tool for a quick verification of DNA amplification and the successful PCR process. Due to their miniaturized setup, compatibility with advanced micro- and nanotechnologies, and ability to detect biomolecules by their intrinsic molecular charge, those sensors can serve as possible platform for the development of label-free DNA chips. Possible application fields as well as challenges and limitations will be discussed. Y1 - 2017 U6 - http://dx.doi.org/10.3390/proceedings1080719 SN - 2504-3900 N1 - This article belongs to the Proceedings of "Proceedings of the 5th International Symposium on Sensor Science (I3S 2017)" VL - 1 IS - 8 SP - Artikel 719 PB - MDPI CY - Basel ER - TY - JOUR A1 - Molinnus, Denise A1 - Janus, Kevin Alexander A1 - Fang, Anyelina C. A1 - Drinic, Aleksander A1 - Achtsnicht, Stefan A1 - Köpf, Marius A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Thick-film carbon electrode deposited onto a biodegradable fibroin substrate for biosensing applications JF - Physica status solidi (a) N2 - This study addresses a proof-of-concept experiment with a biocompatible screen-printed carbon electrode deposited onto a biocompatible and biodegradable substrate, which is made of fibroin, a protein derived from silk of the Bombyx mori silkworm. To demonstrate the sensor performance, the carbon electrode is functionalized as a glucose biosensor with the enzyme glucose oxidase and encapsulated with a silicone rubber to ensure biocompatibility of the contact wires. The carbon electrode is fabricated by means of thick-film technology including a curing step to solidify the carbon paste. The influence of the curing temperature and curing time on the electrode morphology is analyzed via scanning electron microscopy. The electrochemical characterization of the glucose biosensor is performed by amperometric/voltammetric measurements of different glucose concentrations in phosphate buffer. Herein, systematic studies at applied potentials from 500 to 1200 mV to the carbon working electrode (vs the Ag/AgCl reference electrode) allow to determine the optimal working potential. Additionally, the influence of the curing parameters on the glucose sensitivity is examined over a time period of up to 361 days. The sensor shows a negligible cross-sensitivity toward ascorbic acid, noradrenaline, and adrenaline. The developed biocompatible biosensor is highly promising for future in vivo and epidermal applications. KW - biocompatible materials KW - biodegradable electronic devices KW - biosensors KW - carbon electrodes KW - glucose Y1 - 2022 U6 - http://dx.doi.org/10.1002/pssa.202200100 SN - 1862-6319 N1 - Corresponding author: Michael J. Schöning VL - 219 IS - 23 SP - 1 EP - 9 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Suso, Henri-Pierre A1 - Rysstad, Gunnar A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes JF - Physica status solidi (a) N2 - A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests. KW - calorimetric gas sensor;hydrogen peroxide;wireless sensor system Y1 - 2013 U6 - http://dx.doi.org/10.1002/pssa.201200920 SN - 1862-6319 VL - 210 IS - 5 SP - 877 EP - 883 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Werner, Frederik A1 - Wagner, Torsten A1 - Yoshinobu, Tatsuo A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Frequency behaviour of light-addressable potentiometric sensors JF - Physica Status Solidi (A) N2 - Light-addressable potentiometric sensors (LAPS) are semiconductor-based potentiometric sensors, with the advantage to detect the concentration of a chemical species in a liquid solution above the sensor surface in a spatially resolved manner. The addressing is achieved by a modulated and focused light source illuminating the semiconductor and generating a concentration-depending photocurrent. This work introduces a LAPS set-up that is able to monitor the electrical impedance in addition to the photocurrent. The impedance spectra of a LAPS structure, with and without illumination, as well as the frequency behaviour of the LAPS measurement are investigated. The measurements are supported by electrical equivalent circuits to explain the impedance and the LAPS-frequency behaviour. The work investigates the influence of different parameters on the frequency behaviour of the LAPS. Furthermore, the phase shift of the photocurrent, the influence of the surface potential as well as the changes of the sensor impedance will be discussed. Y1 - 2013 U6 - http://dx.doi.org/10.1002/pssa.201200929 SN - 1521-396X ; 0031-8965 VL - 210 IS - 5 SP - 884 EP - 891 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Pilas, Johanna A1 - Selmer, Thorsten A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Screen-printed carbon electrodes modified with graphene oxide for the design of a reagent-free NAD+-dependent biosensor array JF - Analytical Chemistry Y1 - 2019 U6 - http://dx.doi.org/10.1021/acs.analchem.9b04481 VL - 91 IS - 23 SP - 15293 EP - 15299 PB - ACS Publications CY - Washington ER - TY - JOUR A1 - Wert, Stefan A1 - Iken, Heiko A1 - Schöning, Michael Josef A1 - Matysik, Frank-Michael T1 - Development of a temperature‐pulse enhanced electrochemical glucose biosensor and characterization of its stability via scanning electrochemical microscopy JF - Electroanalysis N2 - Glucose oxidase (GOx) is an enzyme frequently used in glucose biosensors. As increased temperatures can enhance the performance of electrochemical sensors, we investigated the impact of temperature pulses on GOx that was drop-coated on flattened Pt microwires. The wires were heated by an alternating current. The sensitivity towards glucose and the temperature stability of GOx was investigated by amperometry. An up to 22-fold increase of sensitivity was observed. Spatially resolved enzyme activity changes were investigated via scanning electrochemical microscopy. The application of short (<100 ms) heat pulses was associated with less thermal inactivation of the immobilized GOx than long-term heating. Y1 - 2021 U6 - http://dx.doi.org/10.1002/elan.202100089 SN - 1521-4109 IS - Early View PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Jablonski, Melanie A1 - Münstermann, Felix A1 - Nork, Jasmina A1 - Molinnus, Denise A1 - Muschallik, Lukas A1 - Bongaerts, Johannes A1 - Wagner, Torsten A1 - Keusgen, Michael A1 - Siegert, Petra A1 - Schöning, Michael Josef T1 - Capacitive field‐effect biosensor applied for the detection of acetoin in alcoholic beverages and fermentation broths JF - physica status solidi (a) applications and materials science N2 - An acetoin biosensor based on a capacitive electrolyte–insulator–semiconductor (EIS) structure modified with the enzyme acetoin reductase, also known as butane-2,3-diol dehydrogenase (Bacillus clausii DSM 8716ᵀ), is applied for acetoin detection in beer, red wine, and fermentation broth samples for the first time. The EIS sensor consists of an Al/p-Si/SiO₂/Ta₂O₅ layer structure with immobilized acetoin reductase on top of the Ta₂O₅ transducer layer by means of crosslinking via glutaraldehyde. The unmodified and enzyme-modified sensors are electrochemically characterized by means of leakage current, capacitance–voltage, and constant capacitance methods, respectively. KW - acetoin KW - acetoin reductase KW - alcoholic beverages KW - biosensors KW - capacitive field-effect sensors Y1 - 2021 U6 - http://dx.doi.org/10.1002/pssa.202000765 SN - 1862-6319 VL - 218 IS - 13 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Jablonski, Melanie A1 - Poghossian, Arshak A1 - Severin, Robin A1 - Keusgen, Michael A1 - Wege, Christian A1 - Schöning, Michael Josef T1 - Capacitive Field-Effect Biosensor Studying Adsorption of Tobacco Mosaic Virus Particles JF - Micromachines N2 - Plant virus-like particles, and in particular, tobacco mosaic virus (TMV) particles, are increasingly being used in nano- and biotechnology as well as for biochemical sensing purposes as nanoscaffolds for the high-density immobilization of receptor molecules. The sensitive parameters of TMV-assisted biosensors depend, among others, on the density of adsorbed TMV particles on the sensor surface, which is affected by both the adsorption conditions and surface properties of the sensor. In this work, Ta₂O₅-gate field-effect capacitive sensors have been applied for the label-free electrical detection of TMV adsorption. The impact of the TMV concentration on both the sensor signal and the density of TMV particles adsorbed onto the Ta₂O₅-gate surface has been studied systematically by means of field-effect and scanning electron microscopy methods. In addition, the surface density of TMV particles loaded under different incubation times has been investigated. Finally, the field-effect sensor also demonstrates the label-free detection of penicillinase immobilization as model bioreceptor on TMV particles. KW - capacitive field-effect sensor KW - plant virus detection KW - tobacco mosaic virus (TMV) KW - TMV adsorption KW - Ta₂O₅ gate Y1 - 2021 U6 - http://dx.doi.org/10.3390/mi12010057 VL - 12 IS - 1 PB - MDPI CY - Basel ER - TY - JOUR A1 - Jablonski, Melanie A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Wege, Christina A1 - Schöning, Michael Josef T1 - Detection of plant virus particles with a capacitive field-effect sensor JF - Analytical and Bioanalytical Chemistry N2 - Plant viruses are major contributors to crop losses and induce high economic costs worldwide. For reliable, on-site and early detection of plant viral diseases, portable biosensors are of great interest. In this study, a field-effect SiO2-gate electrolyte-insulator-semiconductor (EIS) sensor was utilized for the label-free electrostatic detection of tobacco mosaic virus (TMV) particles as a model plant pathogen. The capacitive EIS sensor has been characterized regarding its TMV sensitivity by means of constant-capacitance method. The EIS sensor was able to detect biotinylated TMV particles from a solution with a TMV concentration as low as 0.025 nM. A good correlation between the registered EIS sensor signal and the density of adsorbed TMV particles assessed from scanning electron microscopy images of the SiO2-gate chip surface was observed. Additionally, the isoelectric point of the biotinylated TMV particles was determined via zeta potential measurements and the influence of ionic strength of the measurement solution on the TMV-modified EIS sensor signal has been studied. KW - Plant virus KW - Capacitive field-effect sensor KW - Tobacco mosaic virus (TMV) KW - Label-free detection KW - Zeta potential Y1 - 2021 U6 - http://dx.doi.org/10.1007/s00216-021-03448-8 SN - 1618-2650 N1 - Corresponding authors: Arshak Poghossian & Michael J. Schöning VL - 413 SP - 5669 EP - 5678 PB - Springer Nature CY - Cham ER - TY - JOUR A1 - Janus, Kevin Alexander A1 - Achtsnicht, Stefan A1 - Tempel, Laura A1 - Drinic, Aleksaner A1 - Kopp, Alexander A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Influence of fibroin membrane composition and curing parameters on the performance of a biodegradable enzymatic biosensor manufactured from Silicon-Free Carbon JF - Physica status solidi : pss. A, Applications and materials science N2 - Herein, fibroin, polylactide (PLA), and carbon are investigated for their suitability as biocompatible and biodegradable materials for amperometric biosensors. For this purpose, screen-printed carbon electrodes on the biodegradable substrates fibroin and PLA are modified with a glucose oxidase membrane and then encapsulated with the biocompatible material Ecoflex. The influence of different curing parameters of the carbon electrodes on the resulting biosensor characteristics is studied. The morphology of the electrodes is investigated by scanning electron microscopy, and the biosensor performance is examined by amperometric measurements of glucose (0.5–10 mM) in phosphate buffer solution, pH 7.4, at an applied potential of 1.2 V versus a Ag/AgCl reference electrode. Instead of Ecoflex, fibroin, PLA, and wound adhesive are tested as alternative encapsulation compounds: a series of swelling tests with different fibroin compositions, PLA, and Ecoflex has been performed before characterizing the most promising candidates by chronoamperometry. Therefore, the carbon electrodes are completely covered with the particular encapsulation material. Chronoamperometric measurements with H2O2 concentrations between 0.5 and 10 mM enable studying the leakage current behavior. KW - amperometric biosensors KW - biocompatible KW - biodegradabl KW - encapsulation materials KW - fibroin Y1 - 2023 U6 - http://dx.doi.org/10.1002/pssa.202300081 SN - 1862-6300 (Print) SN - 1862-6319 (Online) N1 - Corresponding author: Michael J. Schöning VL - 220 IS - 22 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Janus, Kevin Alexander A1 - Achtsnicht, Stefan A1 - Drinic, Aleksander A1 - Kopp, Alexander A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Transient magnesium-based thin-film temperature sensor on a flexible, bioabsorbable substrate for future medical applications JF - Applied Research N2 - In this work, the bioabsorbable materials, namely fibroin, polylactide acid (PLA), magnesium and magnesium oxide are investigated for their application as transient, resistive temperature detectors (RTD). For this purpose, a thin-film magnesium-based meander-like electrode is deposited onto a flexible, bioabsorbable substrate (fibroin or PLA) and encapsulated (passivated) by additional magnesium oxide layers on top and below the magnesium-based electrode. The morphology of different layered RTDs is analyzed by scanning electron microscopy. The sensor performance and lifetime of the RTD is characterized both under ambient atmospheric conditions between 30°C and 43°C, and wet tissue-like conditions with a constant temperature regime of 37°C. The latter triggers the degradation process of the magnesium-based layers. The 3-layers RTDs on a PLA substrate could achieve a lifetime of 8.5 h. These sensors also show the best sensor performance under ambient atmospheric conditions with a mean sensitivity of 0.48 Ω/°C ± 0.01 Ω/°C. KW - Silk fibroin KW - Polylactide acid KW - Bioabsorbable KW - Resistive temperature detector Y1 - 2023 U6 - http://dx.doi.org/10.1002/appl.202300102 SN - 2702-4288 (Print) N1 - Corresponding author: Michael Josef Schöning IS - Accepted manuscript PB - Wiley-VCH ER - TY - CHAP A1 - Schöning, Michael Josef A1 - Abdelghani, Adnane T1 - Advancements in Nanotechnology and Microelectronics (ANM '09) <2009, Tunisia>: Proceedings book ; Tunisia, November, 13 & 14, 2009 / Humboldt Kolleg. Ed. by Michael J. Schöning ; Adnane Abdelghani N2 - The ANM’09 multi-disciplinary scientific program includes topics in the fields of "Nanotechnology and Microelectronics" ranging from "Bio/Micro/Nano Materials and Interfacing" aspects, "Chemical and Bio-Sensors", "Magnetic and Superconducting Devices", "MEMS and Microfluidics" over "Theoretical Aspects, Methods and Modelling" up to the important bridging "Academics meet Industry". KW - Nanopartikel KW - Biosensor KW - Supraleiter KW - MEMS KW - Biophoton KW - Nanotechnology ; Microelectronics ; Biosensors ; Superconductor ; MEMS Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-3113 ER - TY - CHAP A1 - Schöning, Michael Josef A1 - Abdelghani, Adnane T1 - Nanoscale Science and Technology (NS&T’12) : Proceedings Book Humboldt Kolleg <2012, Tunisia> ; Tunisia, 17-19 March, 2012 / ed. by Michael J. Schöning ; Adnane Abdelghani N2 - Proceedings of the 2nd Humboldt Kolleg, Hammamet, Tunisia Organizer: Alexander von Humboldt Stiftung, Germany. pdf 184 p. Welcome Address Dear Participants, Welcome to the 2nd Humboldt Kolleg in “Nanoscale Science and Technology” (NS&T’12) in Tunisia, sponsored by the "Alexander von Humboldt" foundation. The NS&T’12 multidisciplinary scientific program includes seven "hot" topics dealing with "Nanoscale Science and Technology" covering basic and application-oriented research as well as industrial (market) aspects: - Molecular Biophyics, Spectroscopy Techniques, Imaging Microscopy - Nanomaterials Synthesis for Medicine and Bio-chemical Sensors - Nanostructures, Semiconductors, Photonics and Nanodevices - New Technologies in Market Industry - Environment, Electro-chemistry, Bio-polymers and Fuel Cells - Nanomaterials, Photovoltaic, Modelling, Quantum Physics - Microelectronics, Sensors Networks and Embedded Systems We are deeply indebted to all members of the Scientific Committee and General Chairs for joint Sessions and to all speakers and chairmen, who have dedicated invaluable time and efforts for the realization of this event. On behalf of the Organizing Committee, we are cordially inviting you to join the conference and hope that your stay will be fruitful, rewarding and enjoyable. Prof. Dr. Michael J. Schöning, Prof. Dr. Adnane Abdelghani KW - Biosensor KW - Nanotechnologie KW - Nanomaterial KW - Nano Materials KW - Bio-Sensors Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-3544 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schubert, J A1 - Kloock, Joachim P. A1 - Zander, W. A1 - Mourzina, Y. G. A1 - Legin, A. A1 - Vlasov, Y. G. A1 - Lüth, H. T1 - Innovative thin film techniques for microfabricating electrochemical sensors JF - Lecture Notes of the ICB Seminars Y1 - 2002 SP - 55 EP - 66 PB - MCB CY - Warsaw ER - TY - JOUR A1 - Schöning, Michael Josef T1 - Silicon-based biochemical sensors JF - CNI - The Center of Nanoelectronic Systems for Information Technology Y1 - 2003 SP - 165 EP - 170 PB - Foschungszentrum Jülich ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Lüth, H. T1 - Microfabricated semiconductor structures – Advances in (bio-)chemical sensing JF - Coupling of biological and electronic systems : proceedings of the 2nd Caesarium, Bonn, November 1 - 3, 2000 / Karl-Heinz Hoffmann, ed. Y1 - 2002 SN - 3-540-43699-5 SP - 79 EP - 92 PB - Springer CY - Berlin [u.a.] ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schubert, Joachim P. A1 - Kloock, Joachim P. A1 - Zander, W. A1 - Mourzina, Y. G. A1 - Legin, A. A1 - Vlasov, Y. G. A1 - Lüth, H. T1 - Innovative thin film techniques for microfabricating electrochemical sensors JF - Biocybernetics and Biomedical Engineering. 21 (2001), H. 4 Y1 - 2001 SN - 0208-5216 SP - 107 EP - 119 ER - TY - JOUR A1 - Schroth, P. A1 - Weißbecker, B. A1 - Schütz, S. A1 - Ecken, H. A1 - Yoshinobu, T. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Bioelectronic signal processing - intact chemoreceptors coupled to field-effect devices JF - Lecture Notes of the ICB Seminars Y1 - 2002 SP - 28 EP - 42 PB - MCB CY - Warsaw ER - TY - JOUR A1 - Schroth, P. A1 - Weißbecker, B. A1 - Schütz, S. A1 - Ecken, H. A1 - Yoshinobu, T. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Bioelectronic signal processing - intact chemoreceptors coupled to field-effect devices JF - Biocybernetics and Biomedical Engineering. 21 (2001), H. 3 Y1 - 2001 SN - 0208-5216 SP - 27 EP - 42 ER - TY - JOUR A1 - Schöning, Michael Josef T1 - Novel approaches to design siliconbased field-effect sensors JF - Electrochemical Microsystem Technologies, New Trends in Electrochemistry Vol. 2 Y1 - 2002 SP - 384 EP - 408 PB - Taylor & Francis CY - London New York ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Lüth, H. T1 - Novel concepts for silicon-based biosensors JF - Physica Status Solidi (A) (2001) Y1 - 2001 SN - 0031-8965 SP - 65 EP - 77 ER - TY - JOUR A1 - Wagner, Torsten A1 - Beging, Stefan A1 - Rotter, L. A1 - Poghossian, Arshak A1 - Biselli, Manfred A1 - Zang, Werner A1 - Schöning, Michael Josef T1 - Online-Messsysteme für die automatisierte Charakterisierung von feldeffektbasierten Biosensoren JF - 8. Dresdner Sensor-Symposium : Sensoren für Umwelt, Klima und Sicherheit, Biosensoren und Biosysteme, Sensoren und Sensorsysteme für die Prozesstechnik, Trends in der Sensortechnik, Materialentwicklung für die Sensorik; 8. Dresdner Sensor-Symposium, 10. - 12. Dezember 2007, Dresden / Gerald Gerlach ... (Hg.) Y1 - 2007 SN - 978-3-940046-45-1 N1 - Dresdner Sensor-Symposium <8, 2007, Dresden> ; Dresdner Beiträge zur Sensorik ; 29 SP - 257 EP - 260 PB - TUDpress, Verl. der Wissenschaften CY - Dresden ER - TY - JOUR A1 - Poghossian, Arshak A1 - Platen, J. A1 - Schöning, Michael Josef T1 - Towards self-aligned nanostructures by means of layerexpansion technique JF - Electrochimica Acta. 51 (2005), H. 5 Y1 - 2005 SN - 0013-4686 SP - 838 EP - 843 ER - TY - JOUR A1 - Näther, Niko A1 - Rolka, David A1 - Poghossian, Arshak A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - Two microcell flow-injection analysis (FIA) platforms for capacitive silicon-based field-effect sensors JF - Electrochimica Acta. 51 (2005), H. 5 Y1 - 2005 SN - 0013-4686 U6 - http://dx.doi.org/10.1016/j.electacta.2005.04.066 SP - 924 EP - 929 ER - TY - JOUR A1 - Simonis, A. A1 - Dawgul, M. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Miniaturised reference electrodes for field-effect sensors compatible to silicon chip technology JF - Electrochimica Acta. 51 (2005), H. 5 Y1 - 2005 SN - 0013-4686 U6 - http://dx.doi.org/10.1016/j.electacta.2005.04.063 SP - 930 EP - 937 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Näther, Niko A1 - Auger, V. A1 - Poghossian, Arshak A1 - Koudelka-Hep, M. T1 - Miniaturised flow-through cell with integrated capacitive EIS sensor fabricated at wafer level using Si and SU-8 technologies JF - Sensors and Actuators B. 108 (2005), H. 1-2 Y1 - 2005 SN - 0925-4005 N1 - Proceedings of the Tenth International Meeting on Chemical Sensors — IMCS - 10 2004 SP - 986 EP - 992 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Detecting Both Physical and (Bio-)Chemical Parameters by Means of ISFET Devices JF - Electroanalysis. 16 (2004), H. 22 Y1 - 2004 SN - 1040-0397 SP - 1863 EP - 1872 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Recent advances in biologically sensitive field-effect transistors (BioFETs) JF - Analyst. 127 (2002) Y1 - 2002 SN - 0003-2654 SP - 1137 EP - 1151 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Lüth, H. A1 - Schultze, J. W. A1 - Schöning, Michael Josef T1 - (Bio-)chemical and physical microsensor array using an identical transducer principle JF - Scaling down in electrochemistry : electrochemical micro- and nanosystem technology ; proceedings of the 3rd International Symposium on Electrochemical Microsystem Technologies, Garmisch-Patenkirchen, Germany, 11 - 15 September 2000 / ed. by J. W. Schultz Y1 - 2001 SN - 0-08-044014-2 SP - 243 EP - 249 PB - Elsevier [u.a.] CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Yoshinobu, T. A1 - Ecken, H. A1 - Ismail, Md.A.B. A1 - Iwasaki, H. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Chemical imaging sensor and its application to biological systems JF - Scaling down in electrochemistry : electrochemical micro- and nanosystem technology ; proceedings of the 3rd International Symposium on Electrochemical Microsystem Technologies, Garmisch-Patenkirchen, Germany, 11 - 15 September 2000 / ed. by J. W. Schultz Y1 - 2001 SN - 0-08-044014-2 SP - 259 EP - 263 PB - Elsevier [u.a.] CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Schroth, P. A1 - Lüth, H. A1 - Hummel, Hans E. A1 - Schütz, S. A1 - Schöning, Michael Josef T1 - Characterising an insect antenna as a receptor for a biosensor by means of impedance spectroscopy JF - Scaling down in electrochemistry : electrochemical micro- and nanosystem technology ; proceedings of the 3rd International Symposium on Electrochemical Microsystem Technologies, Garmisch-Patenkirchen, Germany, 11 - 15 September 2000 / ed. by J. W. Schultz Y1 - 2001 SN - 0-08-044014-2 SP - 293 EP - 297 PB - Elsevier [u.a.] CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Heiduschka, P. A1 - Romann, I. A1 - Ecken, H. A1 - Schöning, Michael Josef A1 - Schuhmann, W. A1 - Thanos, S. T1 - Defined adhesion and growth of neurones on artificial structured substrates JF - Scaling down in electrochemistry : electrochemical micro- and nanosystem technology ; proceedings of the 3rd International Symposium on Electrochemical Microsystem Technologies, Garmisch-Patenkirchen, Germany, 11 - 15 September 2000 / ed. by J. W. Schultz Y1 - 2001 SN - 0-08-044014-2 SP - 299 EP - 307 PB - Elsevier [u.a.] CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Schöning, Michael Josef T1 - Feldeffektstrukturen mit AgI-Aufdampfschichten als chemische Sensoren JF - KfK-Bericht. 5195 (1993) Y1 - 1993 SN - 0303-4003 SP - 1 EP - 95 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Mai, D.-T. A1 - Mourzina, Y. A1 - Schöning, Michael Josef T1 - Impedance effect of an ion-sensitive membrane: characterisation of an EMIS sensor by impedance spectroscopy, capacitance-voltage and constant-capacitance method JF - Sensors and Actuators B. 103 (2004), H. 1-2 Y1 - 2004 SN - 0925-4005 SP - 423 EP - 428 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kloock, Joachim P. T1 - Labor für Chemo- und Biosensorik an der FH Aachen, Abt. Jülich – Mehr als nur studieren JF - Fachblatt Fachhochschule Aachen (2004) Y1 - 2004 SN - 1430-7707 SP - 18 EP - 19 ER - TY - JOUR A1 - Kloock, Joachim P. A1 - Mourzina, Y.G. A1 - Ermolenko, Y. A1 - Doll, T. A1 - Schubert, J. A1 - Schöning, Michael Josef T1 - Inorganic thin-film sensor membranes with PLD-prepared chalcogenide glasses: Challenges and implementation JF - Sensors. 4 (2004), H. 10 Y1 - 2004 SN - 1424-8220 SP - 156 EP - 162 ER - TY - JOUR A1 - Yoshinobu, T. A1 - Schöning, Michael Josef A1 - Finger, F. A1 - Moritz, W. A1 - Iwasaki, H. T1 - Fabrication of thin-film LAPS with amorphous silicon JF - Sensors. 4 (2004), H. 10 Y1 - 2004 SN - 1424-8220 SP - 163 EP - 169 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Ingebrandt, S. A1 - Yeung, C.-K. A1 - Offenhäusser, A. A1 - Schöning, Michael Josef T1 - Microsensors based on ion-sensitive field-effect transistors for biomedical applications JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 1036 EP - 1037 ER - TY - JOUR A1 - Kassab, T. A1 - Han, Y. A1 - Poghossian, Arshak A1 - Ingebrandt, S. A1 - Offenhäusser, A. A1 - Schöning, Michael Josef T1 - Detection of layerby-layer adsorbed polyelectrolytes by means of field-effect based capacitive EIS structures JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 1034 EP - 1035 ER - TY - JOUR A1 - Moritz, W. A1 - Yoshinobu, T. A1 - Finger, F. A1 - Krause, S. A1 - Xu, M. A1 - Schöning, Michael Josef T1 - Microscopy of impedance and surface ion concentrations JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 1000 EP - 1001 ER - TY - JOUR A1 - Ermolenko, Y. E. A1 - Yoshinobu, T. A1 - Mourzina, Y. G. A1 - Vlasov, Y. G. A1 - Schöning, Michael Josef A1 - Iwasaki, H. T1 - Laserscanned transducer (LSST) as a multisensor system JF - Sensors and Actuators B. 103 (2004), H. 1-2 Y1 - 2004 SN - 0925-4005 SP - 457 EP - 462 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Glück, O. A1 - Thust, M. T1 - Electrochemical methods for the determination of chemical variables in aqueous media JF - The measurement, instrumentation, and sensors handbook / ed.-in-chief John G. Webster. In cooperation with IEEE Press Y1 - 1999 SN - 0-8493-8347-1 SP - 1 EP - 49 PB - CRC Press CY - Boca Raton [u.a.] ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Thust, M. A1 - Kordos, P. A1 - Lüth, H. T1 - Chemical sensing structures - From EIS capacitors to array-type sensors JF - Solid state chemical and biochemical sensors : proceedings of Topical Symposium 9 - "Solid State Chemical and Biochemical Sensors" of the Forum on New Materials of the 9th CIMTEC-World Ceramics Congress and Forum on New Materials Florence, Italy June 14-1 Y1 - 1999 SN - 88-86538-27-8 N1 - Serie Advances in science and technology ; 26 SP - 55 EP - 62 PB - Techna CY - Faenza ER - TY - JOUR A1 - Schütz, S. A1 - Weißbecker, G. A1 - Schroth, P. A1 - Schöning, Michael Josef T1 - Linkage of inanimate structures to biological systems – smart materials in biological micro- nanosystems JF - Smart materials : proceedings of the 1st Caesarium, Bonn, November 17 - 19, 1999 / Karl-Heinz Hoffmann ed. Y1 - 2001 SN - 3-540-67957-X SP - 149 EP - 157 PB - Springer CY - Berlin [u.a.] ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schroth, P. A1 - Schütz, S. T1 - The use of insect chemoreceptors for the assembly of biosensors based on semiconductor field-effect sensors JF - Electroanalysis. 12 (2000), H. 9 Y1 - 2000 SN - 1040-0397 SP - 645 EP - 652 ER - TY - JOUR A1 - Yoshinobu, T. A1 - Ui, Y. A1 - Iwasaki, H. A1 - Näther, Niko A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - Potentiometric imaging in a microfluidic channel JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 998 EP - 999 ER - TY - JOUR A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Otto, R. A1 - Yoshinobu, T. T1 - A handheld 16 channel pen-type LAPS as a platform for (bio-)electrochemical sensing JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 996 EP - 997 ER - TY - JOUR A1 - Näther, Niko A1 - Auger, V. A1 - Poghossian, Arshak A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - A miniaturized flow-through cell in SU-8 technique for EIS sensors JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 994 EP - 995 ER - TY - JOUR A1 - Rolka, David A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Integration of a capacitive EIS sensor into a FIA system for pH and penicillin determination JF - Sensors. 4 (2004) Y1 - 2004 SN - 1424-8220 SP - 84 EP - 94 ER - TY - JOUR A1 - Muck, A. A1 - Wang, J. A1 - Jacobs, M. A1 - Chen, G. A1 - Chatrathi, M. P. A1 - Jurka, V. A1 - Vyborny, Z. A1 - Spillmann, S. D. A1 - Sridharan, G. A1 - Schöning, Michael Josef T1 - Fabrication of poly(methyl methacrylate) microfluidic chips by atmospheric molding JF - Analytical Chemistry. 76 (2004), H. 8 Y1 - 2004 SN - 0003-2700 SP - 2290 EP - 2297 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kloock, Joachim P. A1 - Knobbe, D.-T. A1 - Krause, R. A1 - Block, K. A1 - Wang, J. A1 - Mulchandani, A. A1 - Keusgen, M. T1 - Direktnachweis von Pestiziden und Cyanid mit elektrochemischen Enzymsensoren JF - Sensoren und Messsysteme 2004 : Tagung Ludwigsburg, 15. und 16. März 2004 / VDI-VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2004 SN - 3-18-091829-2 N1 - Auch erschienen als: VDI-Berichte ; 1829 SP - 699 EP - 706 PB - VDI CY - Düsseldorf ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Jünger, M. A1 - Keusgen, M. T1 - Knoblauchgehaltsbestimmungen mit einem feldeffektbasierten Halbleiterbiosensor JF - Sensoren und Messsysteme 2004 : Tagung Ludwigsburg, 15. und 16. März 2004 / VDI-VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2004 SN - 3-18-091829-2 N1 - Auch erschienen als: VDI-Berichte ; 1829 SP - 707 EP - 714 PB - VDI CY - Düsseldorf ER - TY - JOUR A1 - Simonis, A. A1 - Lüth, H. A1 - Wang, J. A1 - Schöning, Michael Josef T1 - Miniaturisierte Referenzelektroden in Siliziumtechnologie für elektrochemische Sensoranwendungen JF - Sensoren und Messsysteme 2004 : Tagung Ludwigsburg, 15. und 16. März 2004 / VDI-VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2004 SN - 3-18-091829-2 N1 - Auch erschienen als: VDI-Berichte ; 1829 SP - 847 EP - 850 PB - VDI CY - Düsseldorf ER - TY - JOUR A1 - Knobbe, D.-T. A1 - Schöning, Michael Josef A1 - Poghossian, Arshak A1 - Mourzina, Y. T1 - Charakterisierung von kapazitiven EMISSensoren mittels Impedanzspektroskopie, Kapazitäts-Spannungs- und Konstant-Kapazitäts-Messung JF - Sensoren und Messsysteme 2004 : Tagung Ludwigsburg, 15. und 16. März 2004 / VDI-VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2004 SN - 3-18-091829-2 N1 - Auch erschienen als: VDI-Berichte ; 1829 SP - 851 EP - 854 PB - VDI CY - Düsseldorf ER - TY - JOUR A1 - Mourzina, Ioulia G. A1 - Yoshinobu, Tatsuo A1 - Ermolenko, Yuri E. A1 - Vlasov, Yuri G. A1 - Schöning, Michael Josef A1 - Iwasaki, H. T1 - Immobilization of urease and cholinesterase on the surface of semiconductor transducer for the development of lightaddressable potentiometric sensors JF - Microchimica Acta. 144 (2004), H. 1-3 Y1 - 2004 SN - 0026-3672 SP - 41 EP - 50 ER - TY - JOUR A1 - Moritz, W. A1 - Yoshinobu, T. A1 - Finger, F. A1 - Krause, S. A1 - Martin-Fernandez, M. A1 - Schöning, Michael Josef T1 - High resolution LAPS using amorphous silicon as the semiconductor material JF - Sensors and Actuators B. 103 (2004), H. 1-2 Y1 - 2004 SN - 0925-4005 SP - 436 EP - 444 ER - TY - JOUR A1 - Glück, O. A1 - Schöning, Michael Josef A1 - Lüth, H. A1 - Emons, H. A1 - Otto, A. T1 - Schwermetallbestimmung mittels Widerstandsmessungen und Voltammetrie an Dünnschichtelektroden JF - Chemie- und Biosensoren : aktuelle Anwendungen und Entwicklungstrends / 3. Dresdner Sensor-Symposium, 8. - 10. Dezember 1997, Dresden-Radebeul. J. P. Baselt ... (Hg.) Y1 - 1998 SN - 3-933168-03-1 N1 - Serie Dresdner Beiträge zur Sensorik ; 5 SP - 165 EP - 168 PB - Dresden Univ. Press CY - Dresden ; München ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Prämassing, T. A1 - Beckers, L. A1 - Zander, W. T1 - Ein langzeitstabiler pH-Sensor auf Siliziumbasis hergestellt in Dünnschichttechnik mittels Laserablation JF - Chemie- und Biosensoren : aktuelle Anwendungen und Entwicklungstrends / 3. Dresdner Sensor-Symposium, 8. - 10. Dezember 1997, Dresden-Radebeul. J. P. Baselt ... (Hg.) Y1 - 1998 SN - 3-933168-03-1 N1 - Serie Dresdner Beiträge zur Sensorik ; 5 SP - 99 EP - 102 PB - Dresden Univ. Press CY - Dresden ; München ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Glück, O. A1 - Schroth, P. A1 - Schütz, S. (u.a.) T1 - Microelectrodes, capacitors and BioFETs: Novel trends in silicon-based biochemical sensing JF - Biocybernetics and Biomedical Engineering. 19 (1999), H. 1 Y1 - 1999 SN - 0208-5216 SP - 105 EP - 126 ER - TY - JOUR A1 - Keusgen, M. A1 - Kloock, Joachim P. A1 - Knobbe, D.-T. A1 - Jünger, M. A1 - Krest, I. A1 - Goldbach, M. A1 - Klein, W. A1 - Schöning, Michael Josef T1 - Direct determination of cyanides by potentiometric biosensors JF - Sensors and Actuators B. 103 (2004), H. 1-2 Y1 - 2004 SN - 0925-4005 SP - 380 EP - 385 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Cherstvy, A. A1 - Ingebrandt, S. A1 - Offenhäusser, A. A1 - Schöning, Michael Josef T1 - Possibilities and limitations of label-free detection of DNA hybridization with field-effect-based devices JF - Sensors and Actuators B. 111-112 (2005) Y1 - 2005 SN - 0925-4005 N1 - Eurosensors XVIII 2004 — The 18th European Conference on Solid-State Transducers SP - 470 EP - 480 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Jacobs, M. A1 - Muck, A. A1 - Knobbe, D.-T. A1 - Wang, J. A1 - Chatrathi, M. A1 - Spillmann, S. T1 - Amperometric PDMS/glass capillary electrophoresis-based biosensor microchip for catechol and dopamin detection JF - Sensors and Actuators B. 108 (2005), H. 1-2 Y1 - 2005 SN - 0925-4005 N1 - Proceedings of the Tenth International Meeting on Chemical Sensors — IMCS - 10 2004 SP - 688 EP - 694 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Wagner, Torsten A1 - Wang, C. A1 - Otto, R. A1 - Yoshinobu, T. T1 - Development of a handheld 16 channel pen-type LAPS for electrochemical sensing JF - Sensors and Actuators B. 108 (2005) Y1 - 2005 SN - 0925-4005 SP - 808 EP - 814 ER - TY - JOUR A1 - Schöning, Michael Josef T1 - "Playing around“ with field-effect sensors on the basis of EIS structures, LAPS and ISFETs JF - Sensors. 5 (2005), H. 3 Y1 - 2005 SN - 1424-8220 SP - 126 EP - 138 ER - TY - JOUR A1 - Simonis, A. A1 - Lüth, H. A1 - Wang, J. A1 - Schöning, Michael Josef T1 - New concepts of miniaturised reference electrodes in silicon technology for potentiometric sensor systems JF - Sensors and Actuators B. 103 (2004), H. 1-2 Y1 - 2004 SN - 0925-4005 SP - 429 EP - 435 ER - TY - JOUR A1 - Schöning, Michael Josef T1 - "Voltohmmetry" – a new transducer principle for electrochemical sensors JF - Ultrathin electrochemical chemo- and biosensors : technology and performance / Vladimir M. Mirsky Y1 - 2004 SN - 3-540-21285-X SP - 117 EP - 140 PB - Springer CY - Berlin [u.a.] ER - TY - JOUR A1 - Keusgen, M. A1 - Jünger, M. A1 - Knobbe, D.-T. A1 - Kloock, Joachim P. A1 - Schöning, Michael Josef T1 - Entwicklung eines potentiometrischen Cyanid-Biosensors auf der Basis von EIS-Strukturen JF - Sensoren für zukünftige Hochtechnologien und Neuentwicklungen für die Verfahrenstechnik / 6. Dresdner Sensor-Symposium, 8. - 10. Dezember 2003, Dresden. Jörg Peter Baselt; Gerald Gerlach (Hg.) Y1 - 2003 SN - 3-935712-92-8 SP - 235 EP - 238 PB - w.e.b.-Univ.-Verl. CY - Dresden ER - TY - JOUR A1 - Thust, M. A1 - Schöning, Michael Josef A1 - Muchandani, A. A1 - Wang, J. A1 - Arzdorf, M. A1 - Mulchandani, P. A1 - Chen, W. T1 - Feldeffekt-Enzymsensor zur Detektion von Pestiziden JF - Sensoren für zukünftige Hochtechnologien und Neuentwicklungen für die Verfahrenstechnik / 6. Dresdner Sensor-Symposium, 8. - 10. Dezember 2003, Dresden. Jörg Peter Baselt; Gerald Gerlach (Hg.) Y1 - 2003 SN - 3-935712-92-8 SP - 125 EP - 128 PB - w.e.b.-Univ.-Verl. CY - Dresden ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - "High-order” hybrid FET module for (bio)chemical and physical sensing JF - Integrated analytical systems / ed. by Salvador Alegret Y1 - 2003 SN - 0-444-51037-0 SP - 587 EP - 623 PB - Elsevier CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Strategies for biosensoric detection of potential drugs in nature JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 1004 EP - 1005 ER - TY - JOUR A1 - Kloock, Joachim P. A1 - Mourzina, Y. A1 - Schubert, J. A1 - Ermelenko, Y. A1 - Schöning, Michael Josef T1 - Pulsed laser deposition: A tool for fabricating thin-film microsensors JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 1032 EP - 1033 ER - TY - JOUR A1 - Ermelenko, Y. A1 - Yoshinobu, T A1 - Mourzina, Y. A1 - Levichev, S. A1 - Furuichi, K. A1 - Vlasov, Y. A1 - Schöning, Michael Josef A1 - Iwasaki, H. T1 - Photocurable membranes for ion-selective light-addressable potentiometric sensors JF - Sensors and Actuators B. 85 (2002), H. 1-2 Y1 - 2002 SN - 0925-4005 SP - 79 EP - 85 ER - TY - JOUR A1 - Vlasov, Y. G. A1 - Mourzina, Y. G. A1 - Legin, A. V. A1 - Ermelenko, Y. E. A1 - Schubert, J. A1 - Schöning, Michael Josef A1 - Lüth, H. T1 - Solid-state thin film sensors based on chalcogenide materials prepared by planar technology and pulsed laser deposition JF - Russian Journal of Applied Chemistry. 75 (2002), H. 3 Y1 - 2002 SN - 1070-4272 SP - 351 EP - 356 ER - TY - JOUR A1 - Kurowski, A. A1 - Schultze, J. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Micro- and nanopatterning of sensor chips by means of macroporous silicon. JF - Sensors and Actuators B. 83 (2002), H. 1-3 Y1 - 2002 SN - 0925-4005 N1 - Selected Papers from TRANSDUCERS '01 EUROSENSORS XV SP - 123 EP - 128 ER - TY - CHAP A1 - Groebel, Simone A1 - Werner, Frederik A1 - Jörres, Niklas A1 - Jansen, F. A1 - Kasper, Katharina A1 - Schiffels, Johannes A1 - Sprenger, B. A1 - Baumann, Marcus A1 - Schöning, Michael Josef A1 - Selmer, Thorsten T1 - Entwicklung einer Sensor-Überwachung für Biogasanlagen auf Basis von Prozessdaten einer Parallelanlage T2 - 10. Dresdner Sensor-Symposium : Dresden, 5. - 7. Dezember 2011 ; miniaturisierte analytische Verfahren, Hochtemperatur-Sensoren, Sensoren für Bioprozess- und Verfahrenstechnik, Sensoren für die Medizin, Chemische Verfahrenstechnik, Lebensmittelanalytik, innovative Sensorlösungen, Sensoren für die Wasserqualität, Selbstüberwachung / Gerald Gerlach ... (Hg.) N2 - Beim Ausbau nachhaltiger, regenerativer Energieversorgung hat die Umwandlung von organischer Biomasse in Biogas ein großes Potential. Der zugrundeliegende, komplexe biologische Prozess wird noch immer unzureichend verstanden und bedarf systematischer Untersuchungen der Prozessparameter, um einen hohen Ertrag bei guter Gasqualität zu ermöglichen. Die Fragestellungen zur Entschlüsselung des Prozesses sind sowohl verfahrenstechnischer als auch mikrobiologischer Natur. Aus mikrobiologischer Sicht ist die Kenntnis der tatsächlich beteiligten prozesstragenden Mikroorganismen von erheblicher Bedeutung, aus verfahrenstechnischer Sicht die Kenntnis der physikalischen und chemischen Faktoren, welche die mikrobiologischen Prozesse und kontrollieren. Im Zusammenspiel aller dieser Parameter wird die Biogasbildung befördert oder behindert, bis zum Abbruch des Prozesses. Eine mögliche Kontrollmethode ist die Messung der metabolischen Aktivität prozesstragender Organismen. Diese soll, beruhend auf fundierten Prozessdaten, gewonnen durch eine Parallelanlage, mit einem lichtadressierbaren potentiometrischen Sensor-System (LAPS) realisiert werden. Dieser Sensor ist in der Lage, pH-Wert-änderungen zu detektieren, die durch den Stoffwechsel der auf dem Chip immobilisierten Organismen hervorgerufen werden, um eine Online-Überwachung von Biogasanlagen zu ermöglichen. Y1 - 2011 SN - 978-3-942710-53-4 U6 - http://dx.doi.org/10.5162/10dss2011/4.3 N1 - Dresdner Beiträge zur Sensorik 43 ; Dresdner Sensor-Symposium ; 10 ; 2011 ; Dresden ; Forschungsgesellschaft für Messtechnik, Sensorik und Medizintechnik ; Zehntes Dresdner Sensor-Symposium ; Dresdner Sensor-Symposium ; (10 ; 2011.12.05-07 ; Dresden) SP - 81 EP - 84 PB - TUDpress CY - Dresden ER - TY - JOUR A1 - Ermelenko, Y. A1 - Yoshinobu, T. A1 - Mourzina, Y. A1 - Furuichi, K. A1 - Levichev, S. A1 - Vlasov, Y. A1 - Schöning, Michael Josef A1 - Iwasaki, H. T1 - Lithium sensor based on the laser scanning semiconductor transducer JF - Analytica Chimica Acta. 459 (2002), H. 1 Y1 - 2002 SN - 0378-4304 SP - 1 EP - 9 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak A1 - Schultze, J. W. A1 - Lüth, H. T1 - Field-effect based multifunctional hybrid sensor module for the determination of both (bio-)chemical and physical paramters JF - Proceedings of SPIE. 4576 (2002) Y1 - 2002 SP - 149 EP - 159 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Berndsen, Lars A1 - Lüth, Hans A1 - Schöning, Michael Josef T1 - Novel concepts for flow-rate and flow-direction determination by means of pH-sensitive ISFETs JF - Proceedings of SPIE. 4560 (2001) Y1 - 2001 SP - 19 EP - 27 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schroth, Peter A1 - Lüth, Hans A1 - Hummel, Hans E. A1 - Schütz, Stefan T1 - Insect chemoreceptors coupled to silicon transistors as innovative biosensors JF - Proceedings of SPIE. 4205 (2001) Y1 - 2001 SP - 152 EP - 162 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak A1 - Yoshinobu, Tatsuo A1 - Lüth, Hans T1 - Semiconductor-based field-effect structures for chemical sensing Y1 - 2001 SP - 188 EP - 198 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kurowski, A. A1 - Thust, M. A1 - Kordos, P. A1 - Schultze, J. W. A1 - Lüth, H. T1 - Capacitive microsensors for biochemical sensing on porous silicon technology JF - Sensors and Actuators B. 64 (2000), H. 1-3 Y1 - 2000 SN - 0925-4005 SP - 59 EP - 64 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schütz, S. A1 - Schroth, P. A1 - Weißbecker, B. A1 - Steffen, A. A1 - Kordos, P. A1 - Hummel, Hans E. T1 - A BioFET on the basis of intact insect antennae JF - Sensors and Actuators B. 47 (1998), H. 1-3 Y1 - 1998 SN - 0925-4005 SP - 235 EP - 238 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Thust, M. A1 - Müller-Veggian, Mattea A1 - Kordos, P. T1 - A novel silicon-based sensor array with capacitive EIS structures JF - Sensors and Actuators B. 47 (1998), H. 1-3 Y1 - 1998 SN - 0925-4005 SP - 225 EP - 230 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Tsarouchas, D. A1 - Schaub, A. A1 - Beckers, L. (u.a.) T1 - A highly long-term stable silicon-based pH sensor using pulsed laser deposition technique JF - Sensors and Actuators B. 35 (1996), H. 1-3 Y1 - 1996 SN - 0925-4005 SP - 228 EP - 233 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Sauke, M. A1 - Steffen, A. A1 - Marso, M. (u.a.) T1 - Ion-sensitive field-effect transistors with ultrathin Langmuir-Blodgett membranes JF - Sensors and Actuators B. 27 (1995), H. 1-3 Y1 - 1995 SN - 0925-4005 SP - 325 EP - 328 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Bruns, M. A1 - Hoffmann, W. A1 - Hoffmann, B. (u.a.) T1 - Iodide ion-sensitive field-effect structures JF - Sensors and Actuators B. 15 (1993), H. 1-3 Y1 - 1993 SN - 0925-4005 SP - 192 EP - 194 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Simonis, Anette A1 - Ruge, Christian A1 - Ecken, Holger A1 - Müller-Veggian, Mattea A1 - Lüth, Hans T1 - A (bio-)chemical Field-effect Sensor with Macroporous Si as Substrate Material and a SiO₂ / LPCVD-Si₃N₄ Double Layer as pH Transducer JF - Sensors. 2 (2002), H. 1 N2 - Macroporous silicon has been etched from n-type Si, using a vertical etching cell where no rear side contact on the silicon wafer is necessary. The resulting macropores have been characterised by means of Scanning Electron Microscopy (SEM). After etching, SiO₂ was thermally grown on the top of the porous silicon as an insulating layer and Si₃N₄ was deposited by means of Low Pressure Chemical Vapour Deposition (LPCVD) as transducer material to fabricate a capacitive pH sensor. In order to prepare porous biosensors, the enzyme penicillinase has been additionally immobilised inside the porous structure. Electrochemical measurements of the pH sensor and the biosensor with an Electrolyte/Insulator/Semiconductor (EIS) structure have been performed in the Capacitance/Voltage (C/V) and Constant capacitance (ConCap) mode. Y1 - 2002 SN - 1424-8220 U6 - http://dx.doi.org/10.3390/s20100011 SP - 11 EP - 22 ER - TY - JOUR A1 - Simonis, A. A1 - Krings, T. A1 - Lüth, H. A1 - Wang, J. A1 - Schöning, Michael Josef T1 - A „hybrid“ thin-film pH sensor with integrated thick-film reference JF - Sensors. 1 (2001), H. 6 Y1 - 2001 SN - 1424-8220 SP - 183 EP - 192 ER -