TY - JOUR A1 - Bung, Daniel Bernhard A1 - Crookston, Brian M. A1 - Valero, Daniel T1 - Turbulent free-surface monitoring with an RGB-D sensor: the hydraulic jump case JF - Journal of Hydraulic Research Y1 - 2020 U6 - https://doi.org/10.1080/00221686.2020.1844810 SN - 1814-2079 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Erpicum, Sebastien A1 - Crookston, Brian M. A1 - Bombardelli, Fabian A1 - Bung, Daniel Bernhard A1 - Felder, Stefan A1 - Mulligan, Sean A1 - Oertel, Mario A1 - Palermo, Michele T1 - Hydraulic structures engineering: An evolving science in a changing world JF - Wires Water Y1 - 2021 U6 - https://doi.org/10.1002/wat2.1505 SN - 2049-1948 VL - 8 IS - 2 PB - Wiley CY - Weinheim ER - TY - RPRT A1 - Hebel, Christoph A1 - Merkens, Torsten A1 - Feyerl, Günter A1 - Kemper, Hans A1 - Busse, Daniel T1 - Elektromobilität - Verbundprojekt "COSTARTebus": Comprehensive strategy to accelerate the integration of electric-buses into existing public transport systems - Teilprojekt A : Berichtszeitraum: 01.01.2018-31.10.2020 Y1 - 2021 N1 - Förderkennzeichen BMVI 03EMEN10A Verbundnummer 01182550 PB - Fachhochschule Aachen CY - Aachen ER - TY - RPRT A1 - Thoma, Andreas A1 - Laarmann, Lukas A1 - Merkens, Torsten A1 - Franzke, Till A1 - Möhren, Felix A1 - Buttermann, Lilly A1 - van der Weem, Dirk A1 - Fischer, Maximilian A1 - Misch, Philipp A1 - Böhme, Mirijam A1 - Röth, Thilo A1 - Hebel, Christoph A1 - Ritz, Thomas A1 - Franke, Marina A1 - Braun, Carsten T1 - Entwicklung eines intermodalen Mobilitätskonzeptes für die Pilotregion NRW/Rhein-Maas Euregio und Schaffung voller Kundenakzeptanz durch Transfer von Standards aus dem PKW-Bereich auf ein Flugtaxi : Schlussbericht : Projektakronym: SkyCab (Kategorie B) : Laufzeit in Monaten: 6 : Hauptthema: Kategorie B: Innovative Ideen mit Bezug zu UAS/Flugtaxis Y1 - 2020 N1 - Förderkennzeichen BMVI 45UAS1027A-F PB - FH Aachen CY - Aachen ER - TY - RPRT A1 - Kluge, Katharina A1 - Kirsch, Ansgar A1 - Budach, Christoph T1 - Digitale Lehre in der Geotechnik: Aktueller Stand und weitere Entwicklungen T2 - geotechntik N2 - Digitale Lehrmaterialien werden seit mehreren Jahren in den Hochschulen eingesetzt und eröffnen ganz neue Wege zur Vermittlung des Lehrstoffs. Die Erstellung dieser Lehrmaterialien kann allerdings je nach Art und Qualität sehr zeitintensiv sein und für Lehrende einen großen Mehraufwand bedeuten. Im Rahmen eines Kooperationsprojekts zur Erstellung von Lehrvideos für geotechnische Feld- und Laborversuche haben die Autoren dieses Beitrags allerdings die Erfahrung gemacht, dass das gemeinsame, hochschulübergreifende Erstellen von Lehrmaterialien viele Vorteile mit sich bringt. Dadurch inspiriert, führten die Autoren dieses Berichts eine Umfrage unter den deutschsprachigen Geotechnik-Lehrstühlen der (Technischen) Universitäten und (Fach-)Hochschulen durch. Nach drei Semestern, in denen Lehrveranstaltungen an den Hochschulen aufgrund der Corona-Pandemie überwiegend digital durchgeführt werden mussten, war es ein Ziel dieser Umfrage, den Bestand und den Einsatz digitaler Lehrmaterialien im Fachgebiet Geotechnik zu erheben. Ein weiteres Ziel war die Initiierung eines Netzwerks, in dem sich Geotechnik-Professorinnen und -Professoren zu Lehrthemen austauschen können und gemeinsam (digitale) Lehrmaterialien erstellen und nutzen. Der vorliegende Beitrag stellt das gemeinsame Lehrprojekt der Autoren vor, präsentiert die Ergebnisse der durchgeführten Umfrage und berichtet über die ersten Aktivitäten des neuen Netzwerks. KW - digitale Lehre KW - Geotechnik KW - digital teaching KW - geotechnical engineering KW - Didaktik Y1 - 2022 U6 - https://doi.org/10.1002/gete.202200013 SN - 0172-6145 (Print) SN - 2190-6653 (Online) IS - Early View PB - Ernst & Sohn CY - Berlin ER - TY - CHAP A1 - Blanke, Tobias A1 - Schmidt, Katharina S. A1 - Göttsche, Joachim A1 - Döring, Bernd A1 - Frisch, Jérôme A1 - van Treeck, Christoph ED - Weidlich, Anke ED - Neumann, Dirk ED - Gust, Gunther ED - Staudt, Philipp ED - Schäfer, Mirko T1 - Time series aggregation for energy system design: review and extension of modelling seasonal storages T2 - Energy Informatics N2 - Using optimization to design a renewable energy system has become a computationally demanding task as the high temporal fluctuations of demand and supply arise within the considered time series. The aggregation of typical operation periods has become a popular method to reduce effort. These operation periods are modelled independently and cannot interact in most cases. Consequently, seasonal storage is not reproducible. This inability can lead to a significant error, especially for energy systems with a high share of fluctuating renewable energy. The previous paper, “Time series aggregation for energy system design: Modeling seasonal storage”, has developed a seasonal storage model to address this issue. Simultaneously, the paper “Optimal design of multi-energy systems with seasonal storage” has developed a different approach. This paper aims to review these models and extend the first model. The extension is a mathematical reformulation to decrease the number of variables and constraints. Furthermore, it aims to reduce the calculation time while achieving the same results. KW - Energy system KW - Renewable energy KW - Mixed integer linear programming (MILP) KW - Typical periods KW - Time-series aggregation Y1 - 2022 U6 - https://doi.org/10.1186/s42162-022-00208-5 SN - 2520-8942 N1 - 11th DACH+ Conference on Energy Informatics, 15-16 September 2022, Freiburg, Germany VL - 5 IS - 1, Article number: 17 PB - Springer Nature ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Timmer, H. T1 - Energetische und betriebswirtschaftliche Bewertung von Kühlsystemen für Kühllager JF - HLH. Heizung, Lüftung/Klima, Haustechnik KW - Heizung KW - Lüftung KW - Klimatechnik KW - Lüftungstechnik KW - Haustechnik Y1 - 1998 SN - 1436-5103 VL - 49 IS - 9 SP - 74 EP - 77 PB - Springer CY - Düsseldorf ER - TY - CHAP A1 - Thulfaut, Christian A1 - Groß, Rolf Fritz A1 - Renz, Ulrich ED - Jamal, Rahman ED - Jaschinski, Hans T1 - Messwerterfassung und –auswertung mit LabView: Experimentelle Analyse der Mischungsgüte in Hybridzellenkühltürmen T2 - Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000 N2 - Zur Kühlung von Abwärmeströmen aus Kraftwerksprozessen werden in zunehmenden Maße Hybridzellenkühltürme mit Zwangskonvektion eingesetzt, deren wesentlicher Vorteil ihre geringe Bauhöhe ist. Um bei derartigen Kühltürmen eine Sichtbehinderung oder Glatteisgefährdung durch bodennahen Nebel zu vermeiden, muss durch eine optimale Vermischung des Trocken- und Naßluftanteils gewährleistet sein, daß aus der Kühlturmkrone keine Nebelschwaden austreten. In Zusammenarbeit mit der Industrie betreibt der Lehrstuhl für Wärmeübertragung und Klimatechnik der RWTH Aachen einen Versuchsstand zur Erfassung der Mischungsgüte in Hybridzellenkühltürmen. In maßstabsgerechter Nachbildung können dabei am Modell alle relevanten Einflußgrößen wie Kühlturmgeometrie, Gestaltung zusätzlicher Mischeinbauten sowie die Betriebsparameter variiert werden. Mit Hilfe einer unter LabView 5.01 erstellten Software werden sowohl die l3etriebszustüncle online überwacht, als auch die benötigten Meßwerte zur Bestimmung der Mischungsgüte erfaßt. Über die grafische Oberfläche können sämtliche Meßoptionen gesteuert sowie alle Meßdaten visualisiert und kontrolliert werden. In das LabView-Programm sind darüber hinaus Routinen zur Auswertung der Daten implementiert worden, die sowohl eine direkte Darstellung der Ergebnisse in Form von Diagrammen ermöglichen, als auch zur Weiterverarbeitung einen Datenexport in eine Microsoft- Excel-Tabelle vorsehen. N2 - The Institute of Heat Transfer and Air Conditioning at the Aachen University of Technology operates in co-operation with industrial partners a test facility in order to investigate mixture quality in hybrid cooling towers. In a scaled mock-up a variation of all relevant data such as the geometry of the cooling tower, the design of additional mixers and the operation parameters could be realized. A software tool, created with LabView 5.01, offers the possibility to control the whole process and to measure all relevant quantities. The graphic user interface permits an online control and a visualization of the measured values. Beyond this the program is not only able to evaluate the data and to represent the results in form of diagrams, but also to export the data directly into an Microsoft-Excel-sheet for further analysing. Y1 - 2000 SN - 3-7785-2789-4 (print) SP - 54 EP - 60 PB - Hüthig CY - Heidelberg ER - TY - CHAP A1 - Groß, Rolf Fritz A1 - Thulfaut, Christian A1 - Renz, Ulrich ED - Jamal, Rahman ED - Jaschinski, Hans T1 - On-Line Simulation mit LabView: Experimentelle und numerische Analyse homogener Gasphasenreaktionen aus Kraftwerksprozessen, T2 - Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000 N2 - The institute of heat transfer and air conditioning at the Aachen University of Technology operates several test facilities in order to investigate homogeneous and catalytical processes for the reduction of gaseous pollutants (e.g. nitrous oxide) of flue gases in a tempeature range up to 900°C. One test facility consists of a stainless steel reactor in which the influence of reducing additives can be investigated. The software tool, created with LabVIEW 5.01, offers the possibility to measure, visualize and control all relevant physical quantities and to gain a numerical solution of the problem by solving the one dimensional, steady state conservation equations. N2 - Die bei Kohlekraftwerksprozessen entstehenden Rauchgase enthalten einen nicht unerheblichen Teil an Schadgaskomponenten (z.B. Stickoxide), die aus dem Gasstrom entfernt werden müssen. Im Rahmen von Forschungsvorhaben des BMBF und verschiedener Industriepartner betreibt der Lehrstuhl für Wärmeübertragung und Klimatechnik der RWTH Aachen Pilotanlagen und Prüfstände für Untersuchungen auf dem Gebiet der homogenen und heterogen-katalytischen Schadstoffreduktion heißer Rauchgase bei Temperaturen bis zu 900 °C. Für die Erforschung der Minderungspotentiale geeigneter, auf Distickstoffoxid reduzierend wirkender Additive, wie Wasserstoffperoxid, oder auch Katalysatoren, befindet sich ein Reaktor in Betrieb, der eine Untersuchung der Reaktionskinetik bei der Entfernung von Schadgaskomponenten aus einem lnertgasstrom ermöglicht. Wesentlich für den Erfolg der Forschungsarbeit ist eine auf das spezielle Projekt genau abgestimmte Meß- und Regelungstechnik. Neben der Auswahl geeigneter Hardwarekomponenten ist auch die Softwareentwicklung unter einer leistungsstarken und zuverlässigen Programmierumgebung von großer Bedeutung. Hierbei dient die unter LabVIEW 5.01 entwickelte Datenerfassung- und Auswertesoftware zum einen der Messung, Visualisierung und Regelung der relevanten Temperaturen, Drücke, Konzentrationen und Volumenströme einzelner Gaskomponenten. Zum anderen ermöglicht sie parallel eine numerische Simulation der Vorgänge innerhalb des Reaktors zur Anpassung reaktionskinetischer Parameter aus den sich ergebenden Versuchsdaten durch Lösung eindimensionaler, stationärer Erhaltungsgleichungen. Y1 - 2000 SN - 3-7785-2789-4 (print) SP - 103 EP - 108 PB - Hüthig CY - Heidelberg ER - TY - RPRT A1 - Christ, Ansgar A1 - Groß, Rolf Fritz A1 - Renz, Ulrich T1 - Strömungs-, Filterkuchen- und Abreinigungsmodelle für Heißgasfilter, Teilvorhaben "Numerische Simulation des Abreinigungsvorganges und der Rohgasströmung" KW - Prozesssimulation KW - Filterkuchen KW - Druckvergasung KW - Druckwirbelschichtfeuerung KW - Rauchgasreinigung Y1 - 1998 U6 - https://doi.org/10.2314/GBV:50431601X N1 - Verbundprojekt im Rahmen der Projektträgerschaft BEO des BMBF der Partner RWTH Aachen, Lehrstuhl für Wärmeübertragung und Klimatechnik Brandenburgische Technische Universität Cottbus, Lehrstuhl Regelungstechnik Universität Karlsruhe, Institut für Mechanische Verfahrenstechnik und Mechanik LLB Lurgi Lentjes Babcock Energietechnik GmbH, Oberhausen Förderkennzeichen: 0326831B Abschlußbericht ER - TY - CHAP A1 - Dautzenberg, H. A1 - Groß, Rolf Fritz A1 - Renz, Ulrich ED - Jamal, Rahman T1 - Meßtechnik auf dem Prüfstand: Forschung zur Heißgasfiltration T2 - Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 1996 N2 - Im Rahmen von Forschungsvorhaben des BMBF und verschiedener Industriepartner betreibt der Lehrstuhl für Wärmeübertragung und Klimatechnik der RWTH Aachen Pilotanlagen und Prüfstände für Untersuchungen auf dem Gebiet der Heißgasfiltration mit keramischen Filterelementen. Als wesentlicher Garant für den Erfolg der Forschungsarbeit muß die auf das jeweilige Projekt genau abgestimmte Meß- und Regelungstechnik angesehen werden. Hierbei zählt neben der Auswahl geeigneter Hardwarekomponenten auch die Softwareentwicklung unter einer leistungsstarken und zuverlässigen Programmierumgebung. Anhand des Aufbaus dreier Versuchsanlagen im Technikumsmaßstab soll das Anforderungsprofil an die Meßtechnik bis hin zur Umsetzung innerhalb der Anlage skizziert werden. Der Heißgasfiltrationsprüfstand im Heizkraftwerk der RWTH Aachen dient der Beobachtung des Reinigungsverhaltens keramischer Filterelemente bei der Heißgasentstaubung im Temperaturbereich bis 850 Grad C. Wesentlich für die Meßwerterfassung ist hierbei die Kopplung eines Orion-Datenloggers der Firma Schlumberger mit LabView 4.0. Im Hochtemperaturofen des Lehrstuhls werden instationäre Druckmessungen an einer keramischen Filterkerze während eines Abreinigungsimpulses bei 950 Grad C mit hoher Samplingrate durchgeführt. Hierbei übernimmt eine durch LabView 4.0 angesteuerte E-Series Karte der Firma National Instruments die Signalaufnahme. Die katalytische Schadstoffreduktion und Entstaubung heißer Rauchgase bei 900 Grad C sind Ziele der Untersuchungen in einer erstellten Versuchsanlage mit einem Quarzglasreaktor. Die Signalerfassung und -konditionierung erfolgt über SCXI in Verbindung mit LabView 4.0, die Steuerung der Anlage übernehmen zwei Multifunktionskarten (National Instruments). KW - keramischer Werkstoff KW - Filter (Stofftrennung) KW - Filtration KW - Entstaubung KW - Staubfilter Y1 - 1996 N1 - 5.-6. November 1996 Forum der Technik München, Germany SP - 202 EP - 208 PB - National Instruments Germany CY - München ER - TY - CHAP A1 - Groß, Rolf Fritz A1 - Müller, D. A1 - Herting, D. A1 - Schneemann, A. A1 - Renz, Ulrich ED - Rahman, Jamal ED - Jaschinski, Hans T1 - Modulare Messdatenerfassung in Forschung und Lehre T2 - Virtuelle Instrumente in der Praxis : Begleitband zum Kongress VIP '97 N2 - The Lehrstuhl für Wärmeübertragung und Klimatechnik at the Aachen University of Technology operates several test facilities to investigate fundamentals of heat and mass transfer supported by the Deutsche Forschungsgemeinschaft, the Minister für Forschung und Technologie and the industry. In order to get high-resolution and reproselection of hardware components is as critical as the design of software routines to perform successful and accurate measurements. In the following the development of the measurement and control system for three different test facilities is presented and discussed. Special attention is given to the education of students within the framework of laboratories and scientific experiments. Y1 - 1997 SN - 978-3-7785-2667-5 Pp. SP - 282 EP - 288 PB - Hüthig CY - Heidelberg ER - TY - CHAP A1 - Schulze-Buxloh, Lina A1 - Groß, Rolf Fritz A1 - Ulbrich, Michelle T1 - Digital planning using building information modelling and virtual reality: new approach for students’ remote practical training under lockdown conditions in the course of smart building engineering T2 - Proceedings of International Conference on Education in Mathematics, Science and Technology 2021 N2 - The worldwide Corona pandemic has severely restricted student projects in the higher semesters of engineering courses. In order not to delay the graduation, a new concept had to be developed for projects under lockdown conditions. Therefore, unused rooms at the university should be digitally recorded in order to develop a new usage concept as laboratory rooms. An inventory of the actual state of the rooms was done first by taking photos and listing up all flaws and peculiarities. After that, a digital site measuring was done with a 360° laser scanner and these recorded scans were linked to a coherent point cloud and transferred to a software for planning technical building services and supporting Building Information Modelling (BIM). In order to better illustrate the difference between the actual and target state, two virtual reality models were created for realistic demonstration. During the project, the students had to go through the entire digital planning phases. Technical specifications had to be complied with, as well as documentation, time planning and cost estimate. This project turned out to be an excellent alternative to on-site practical training under lockdown conditions and increased the students’ motivation to deal with complex technical questions. KW - smart building engineering KW - building information modelling KW - virtual reality KW - lockdown conditions KW - emote practical training Y1 - 2021 SN - 978-1-952092-17-6 N1 - International Conference on Education in Mathematics, Science and Technology 2021, April 1-4, 2021 in Antalya, Turkey SP - 118 EP - 123 PB - ISTES Organization CY - San Antonio, TX ER - TY - CHAP A1 - Duran Paredes, Ludwin A1 - Mottaghy, Darius A1 - Herrmann, Ulf A1 - Groß, Rolf Fritz T1 - Online ground temperature and soil moisture monitoring of a shallow geothermal system with non-conventional components T2 - EGU General Assembly 2020 N2 - We present first results from a newly developed monitoring station for a closed loop geothermal heat pump test installation at our campus, consisting of helix coils and plate heat exchangers, as well as an ice-store system. There are more than 40 temperature sensors and several soil moisture content sensors distributed around the system, allowing a detailed monitoring under different operating conditions.In the view of the modern development of renewable energies along with the newly concepts known as Internet of Things and Industry 4.0 (high-tech strategy from the German government), we created a user-friendly web application, which will connect the things (sensors) with the open network (www). Besides other advantages, this allows a continuous remote monitoring of the data from the numerous sensors at an arbitrary sampling rate.Based on the recorded data, we will also present first results from numerical simulations, taking into account all relevant heat transport processes.The aim is to improve the understanding of these processes and their influence on the thermal behavior of shallow geothermal systems in the unsaturated zone. This will in turn facilitate the prediction of the performance of these systems and therefore yield an improvement in their dimensioning when designing a specific shallow geothermal installation. Y1 - 2020 N1 - EGU General Assembly 2020, Online, 4–8 May 2020 ER - TY - RPRT A1 - Ayar, A. A1 - Fielenbach, C. A1 - Groß, Rolf Fritz A1 - Holfeld, T. A1 - Lockemann, S. A1 - Severin, C. A1 - Thulfaut, Christian A1 - Hillemacher, B. T1 - Druckkohlenstaubverbrennung von rheinischer Braunkohle : Abschlussbericht T1 - Pressure combustion of rhenish brown coal : final report N2 - Im Rahmen des Forschungsschwerpunkts 3 wurde experimentell und theoretisch die NO{sub x}-Bildung und -Reduktion bei der Druckkohlenstaubverbrennung untersucht. Der zuvor beschriebene Einfluss der Kohlemahlung auf die Flamme konnte auch anhand der NO{sub x}-Messungen an der DKSF-Anlage Aachen bestaetigt werden. Waehrend mit Braunkohle im Staubfeuerungsbetrieb noch keine eindeutige Druckabhaengigkeit nachgewiesen werden konnte, haben vom Lehrstuhl durchgefuehrte NO{sub x}-Messungen an der DKSF-Anlage Dorsten im Schmelzkammerfeuerungsbetrieb mit der Steinkohle Spitzbergen zwischen 9 und 13 bar ein Absinken der Stickoxidkonzentrationen mit steigendem Druck ergeben. Fuer die rheinische Braunkohle soll dieser Druckeinfluss in den naechsten Versuchsfahrten ausfuehrlicher untersucht werden. Es wurde anhand von numerischen Simulationen zu einer Braunkohleflamme der 6. Versuchsfahrt ein Vergleich zwischen der NO{sub x}-Modellierung im Standard-FLUENT-Code und in dem mit User Defined Subroutines der international flame research foundation (IFRF), Ijmuiden, erweiterten FLUENT-Code vorgenommen. Es zeigte sich, dass bei der Modellierung der Stickoxidbildung die unterschiedlich vorhergesagten Flammentemperaturen eine entscheidende Rolle spielen. Eine genauere Analyse der NO{sub x}-Modelle im Vergleich zu Messergebnissen ist bei einer Schmelzkammerfeuerung mit einer stabilen Flamme vorzunehmen. Es wurden zusaetzlich Messungen zur Untersuchung der Kinetik homogener Gasphasenreaktionen in Rauchgasen an einem Stahlreaktor durchgefuehrt. Dabei wurde sowohl der thermisch bedingte als auch der durch zudosierte Additive katalysierte Abbau nitroser Komponenten betrachtet. Vergleichend wurden mit einem am Lehrstuhl entwickelten Programm die Kinetik beschrieben. Hierbei wird mit einer Sensitivitaetsanalyse eine Reduzierung der detaillierten Darstellung der Reaktionskinetik erreicht, die es erlaubt, mit einem CFD-Code wie FLUENT zwei- und dreidimensionale Rechnungen zum Abbau verschiedener Rauchgaskomponenten durchzufuehren. Die Uebereinstimmung zwischen ein- und zweidimensionalen Rechnungen und den Messungen ist gut. N2 - NOx formation and reduction in the coal combustion process was investigated both experimentally and theoretically. The influence of coal grain size described in earlier publications was proved by the measurements at the DKSF test facility at Aachen. While no pressure dependence was established so far for lignite, measurements on Spitzbergen coal at 9 - 13 bar showed a decrease in NOx concentrations with increasing pressure. This effect will be investigated for Rhenish brown coal in further experiments. Modelling by the standard FLUENT code and by the user defined subroutines of the FLUENT code developed by the International Flame Research Foundation (IFRF), Ijmuiden, showed that the different predictions of flame temperatures have a decisive role in the modelling of NOx formation. A more accurate analysis of the NOx models as compared to ther measurements will be carried out in a melting chamber furnace with a stable flame. Additionally, measurements were carried out for investigating the kinetics of homogeneous gaseous phase reactions in flue gases, i.e. the thermal and additive-catalysed degradation of nitrous components was investigated. The kinetics of the process was also described by a code developed at Aachen University. On the base of a sensitivity analysis, a reduction of the detailed modelling of the reaction kinetics is achieved which permits 2D and 3D calculations on the decomposition of different flue gas components using a CFD code like FLUENT. The 1D and 2D calculations and the measurements were found to be in good agreement. Y1 - 2003 N1 - Druckkohlenstaubverbrennung von rheinischer Braunkohle Förderkennzeichen: 0327072 Abschlussbericht zum Forschungsvorhaben ausführende Stelle: Lehrstuhl fur Wärmeübertragung und Klimatechnik der RWTH Aachen Professor Dr.-Ing. U. Renz ER - TY - JOUR A1 - Thulfaut, Christian A1 - Groß, Rolf Fritz T1 - Experimentelle Untersuchung der Luftstromvermischung in Hybridzellenkühltürmen JF - HLH. Heizung, Lüftung/Klima, Haustechnik N2 - Zwangsbelüftete Nasskühltürme haben im Gegensatz zur Trockenkühlung bei naßkaltem Wetter Nebelschwaden zur Folge. Dagegen ist bei Naßkühlung die spezifische Kühlleistung durch abgeführte Kondensationswärme höher als bei der Trockenkühlung. Hybridzellenkühltürme kombinieren beide Methoden, so daß ein Mischstrom beider Abluftströme die Wasserdampf-Sättigungsgrenze nicht überschreitet. Durch das Mischungsverhältnis kann man den gewünschten Sättigungsgrad einstellen. Je dichter dieser an der Sättigungsgrenze liegt, desto höher ist die Kühlleistung. Der von unten zugeführte Luftstrom der Naßkühlung und der seitlich zugeführte trockene Abluftstrom müssen sehr gut durchmischt werden, um über den gesamten Austrittsquerschnitt des Kühlturms die Sättigungsgrenze nicht zu überschreiten. In einem maßstabsgerechten Modell wurde der Mischungsgrad mit und ohne Einbauten untersucht. Über ein Raster von 10 mal 10 Punkten wurde die örtliche Temperaturverteilung ermittelt. Wärmebilanzen ergeben dann die Mischungsgüte in einer Ebene oberhalb der Zellenkrone. Während ohne Mischeinbauten der Trockenluftanteil in der Mitte des Querschnitts bei unter 15 % liegt erhöhen Einbauten den Trockenluftanteil auf 30 % bis über 40 %. Dabei wurde die Trockenluft auf jeder Kühlturmseite durch 4 konisch zulaufende, unten offene und oben geschlitzte Einbauten kanalisiert. Die Nassluft wurde durch eine im Querschnitt dreieckige Rinne in Richtung der Trockenluftauslässe umgelenkt. Im Raster leicht zu lokalisierende Abweichungen vom gewünschten Mittelwert zeigen Potential für die weitere Verbesserung der Einbauten. KW - Trockenkühlturm KW - Nasskühlturm KW - kombiniertes Verfahren KW - Mischen KW - Abluft Y1 - 2000 SN - 1436-5103 VL - 51 IS - 8 SP - 48 EP - 49 PB - Springer CY - Düsseldorf ER - TY - CHAP A1 - Groß, Rolf Fritz A1 - Hecken, M. A1 - Renz, Ulrich ED - Dittler, A. ED - Hemmer, G. ED - Kasper, G. T1 - Hot gas filtration with ceramic filter candles: experimental and numerical investigations on fluid flow during element cleaning T2 - High temperature gas cleaning. Vol. 2 N2 - Ceramic hot gas filters are widely used in combined cycles based on pressurised fluidised beds. They fulfil most of the demands with respect to cleaning efficiency and long time durability, but their operation regarding the consumption of pulse gas and energy still has to be optimised. Experimental investigations were carried out to measure the flow field, the pressure and the gas temperature inside the filter candle during pulse jet cleaning. These results are compared with the results of a numerical procedure based on a solution of the two - dimensional conservation equations for momentum and energy. The observed difficulties handling different flow regimes like highly turbulent flow as well as Darcy flow simultaneously are discussed. KW - 20 fossil-fueled power plants KW - hot gas cleanup KW - ceramics KW - filtration KW - gas flow Y1 - 1999 SN - 3-9805220-1-6 N1 - 4th International Symposium and Exhibition on Gas Cleaning at High Temperatures, 22.-24.09.1999, Karlsruhe SP - 862 EP - 873 PB - KIT Institut für Mechanische Verfahrenstechnik und Mechanik CY - Karlsruhe ER - TY - CHAP A1 - Groß, Rolf Fritz T1 - Möglichkeiten und Grenzen für Forschung an Fachhochschulen T2 - Smart Building Convention und BIMconvention in Aachen im September Y1 - 2018 N1 - 10. und 11. September 2018, Aachen ER - TY - RPRT A1 - Höfler, Matthias A1 - Groß, Rolf Fritz T1 - Optimierung der Oxidationskinetik von Sulfit zu Sulfat durch effiziente feinblasige Belüftung bei Anlagen zur Rauchgasentschwefelung fossil befeuerter Kraftwerke und Industrieanlagen mittels Seewasser ("Optiox") N2 - Das Forschungsvorhaben Optiox beschäftigt sich mit der Optimierung eines Belüftungsbeckens zur Rauchgasentschwefelung fossil befeuerter Kraftwerke mittels Seewasser. Unter Neutralisierung der entstehenden Hydroniumionen (H3O+) durch die natürliche Alkalität des Seewassers dissoziiert Schwefeldioxid aus dem Rauchgase im vorgeschalteten Absorber beim Phasenübergang von der Gas- in die Flüssigphase zu Sulfiten. Im Belüftungsbecken werden diese Sulfite mittels eingeblasener Luft zu Sulfaten oxidiert, was zu einer geringen Erhöhung der Sulfatfracht vor Einleitung ins Meer führt, die unterhalb der natürlichen Schwankungen liegt. Daneben dient das Belüftungsbecken der Konditionierung des Seewassers hinsichtlich pH-Wert und Sauerstoffgehalt und ist mit hoch effizienten Belüftern ausgestattet, deren Spezifikation den jeweiligen Randbedingungen, wie Abscheideleistung des Absorbers, Beckengeometrie sowie lokalen Gegebenheiten angepasst wird. Y1 - 2016 N1 - Projektlaufzeit: 10/2012 – 09/2015 Gefördert durch: BMBF – Förderkennlinie Ingenieurnachwuchs Kooperationspartner: Doosan Lentjes GmbH, Ratingen, FH Aachen, Fachbereich Energietechnik, Prof. Dr.-Ing. Rolf Groß ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Berger, J. T1 - Quo Vadis - Ausblick in die Gebäudeleittechnik der Zukunft T1 - Whitherfacility management? An outlook to the future JF - HLH. Heizung, Lüftung/Klima, Haustechnik N2 - Auf dem Weg zum vernetzten Haus stoßen Hersteller und Planer, insbesondere im privaten Wohnungsbau, zur Zeit noch auf erhebliche Widerstände bei der Durchdringung des Marktes. N2 - Producers and planners of facility management systems are still faced with building owners' reluctance, especially when it comes to private homes. Y1 - 2005 SN - 1436-5103 VL - 56 IS - 1 SP - 39 EP - 41 PB - Springer CY - Düsseldorf ER -