TY - CHAP A1 - Dielmann, Klaus-Peter A1 - Peters, Bernhard T1 - Micro Turbine Using Different Gases and Liquid Fuels N2 - Micro turbine using different gases and liquid fuels KW - Gasturbine KW - Mikrogasturbine KW - Micro turbine Y1 - 2002 ER - TY - CHAP A1 - Surtees, A. J. A1 - Gillespie, A. A1 - Kern, Alexander A1 - Rousseau, A. T1 - DEVELOPMENT OF A RISK ASSESSMENT CALCULATOR BASED ON A SIMPLIFIED FORM OF THE IEC 62305-2 STANDARD ON LIGHTNING PROTECTION N2 - Neue Blitzschutznorm IEC 62305. Entwicklung einer einfachen Software zur Risikoabwägung N2 - IEC Technical Committee 81 is currently creating the new IEC 62305 series of standards on Lightning Protection. Working Group 9 is responsible for Part 2 of this series, which deals with the assessment and management of risk its CDV (Committee Draft for Voting) stage and has been circulated to National Committees for comment. The paper details the development of the Simplified IEC Risk Assessment Calculator software tool as described in Informative Annex J of IEC62305-2 Ed.1/CDV 2. This tool is intended as a simplified implementation of the more rigorous treatment of risk management found in the written document. It is designed to be relatively intuitive for users who wish to obtain an initial assessment of risk sensitivity, but should not be considered a substitute to a full understanding of the methods provided in the standard when dealing with more complicated structures or those where greater risks to personal or system operation are involved. KW - Risiko KW - Risikoabwägung KW - Blitzrisiko KW - Blitzschutz KW - Risk KW - Risk Management KW - Risk Assessment KW - Lightning Risk KW - Lightning Protection Y1 - 2004 ER - TY - CHAP A1 - Kern, Alexander A1 - Heidler, Fridolin A1 - Seevers, M. A1 - Zischank, Wolfgang J. T1 - Magnetic Fields and Induced Voltages in case of a Direct Strike - Comparison of Results obtained from Measurements at a Scaled Building to those of IEC 62305-4 N2 - In the paper the results obtained from experiments at a modelled reinforced building in case of a direct lightning strike are compared with calculations. The comparison includes peak values of the magnetic field Hmax, its derivative (dH/dt)max and of induced voltages umax in typical cable routings. The experiments are performed at a 1:6 scaled building and the results are extrapolated using the similarity relations theory. The calculations are based on the approximate formulae given in IEC 62305-4 and have to be supplemented by a rough estimation of the additional shielding effect of a second reinforcement layer. The comparison shows, that the measured peak values of the magnetic field and its derivative are mostly lower than the calculated. The induced voltages are in good agreement. Hence, calculations of the induced voltages based on IEC 62305-4 are a good method for lightning protection studies of buildings, where the reinforcement is used as a grid-like electromagnetic shield. N2 - Auswirkungen eines direkten Blitzeinschlages auf ein Gebäude, Vergleich von experimentellen Ergebnissen und Berechnungen basierend auf einer Formel aus der IEC 62305-4 KW - Blitz KW - Direkter Blitzschlag KW - Elektromagnetischer Schutzschild KW - Magnetische Felder KW - Induzierte Spannungen KW - Kalkulation KW - Direct lightning strike KW - electromagnetic shield KW - magnetic fields KW - induced voltages KW - calculations Y1 - 2004 SN - 0304-3886 N1 - Journal of electrostatics: Beitr. auf S. 379 - 385. doi:10.1016/j.elstat.2006.09.004 ER - TY - CHAP A1 - Zischank, Wolfgang J. A1 - Heidler, Fridolin A1 - Wiesinger, J. A1 - Stimper, K. A1 - Kern, Alexander A1 - Seevers, M. T1 - Magnetic Fields and Induced Voltages inside LPZ 1 Measured at a 1:6 Scale Model Building N2 - Laborexperimente zu Blitzschutzzonen in Stahlbetongebäuden anhand eines Modells im Maßstab 1:6 N2 - For the application of the concept of Lightning Protection Zones (LPZ), the knowledge of the magnetic fields and induced voltages inside a structure is necessary. Laboratory experiments have been conducted at a downscaled model of a building (scale factor 1:6) to determine these electromagnetic quantities in case of a direct strike to the structure. The model (3 m x 2 m x 2 m) represented a small industrial building using the reinforcement of the concrete as electromagnetic shield. The magnetic fields and magnetic field derivatives were measured at several location inside the scaled model. Further, the voltages induced on three typical cable routes inside the model was determined. The influence of the lightning current waveshape, point-of-strike, bonding of the cable routes, and bridging of an expansion joint in the middle of the building on these quantities was studied. KW - Blitzschlag KW - Elektromagnetischer Schutzschild KW - Stahlbeton KW - Maßstabsgetreues Modell KW - Lightning KW - electromagnetic shielding KW - reinforced concrete KW - scaled model Y1 - 2004 ER - TY - CHAP A1 - Darveniza, M. A1 - Flisowski, Z. A1 - Kern, Alexander A1 - Landers, E.-U. A1 - LoPiparo, G. A1 - Mazzetti, C. A1 - Rousseau, A. A1 - Sherlock, J. T1 - Application problems of the probabilistic approach to the assessment of risk for structures and services N2 - The paper deals with the development of the probabilistic approach to the assessment of risk due to lightning. Sources of damage, types of damage and types of loss are defined and, accordingly, the procedure for risk analysis and the way of assessment of different risk components is proposed. The way to evaluate the influence of different protection measures (lightning protection system; shielding of structure, cables and equipment; routing of internal wiring; surge protective device) in reducing such probabilities is considered. The paper has been prepared within the framework of the activity of IEC TC81-WG9/CLC TC81-WG4 directed to prepare the draft IEC 62305-2 Risk Management, in cooperation with the Secretary of IEC/CLC TC81. KW - Blitzschutz KW - Risikoabwägung KW - Lightning protection system KW - risk assessment KW - protection measures Y1 - 2002 ER - TY - CHAP A1 - Kern, Alexander A1 - Krichel, Frank T1 - Considerations about the lightning protection system of mains independent renewable energy hybrid-systems - practical experiences N2 - In the paper a lightning protection design concept for renewable energy hybrid-systems without power mains connection is described. Based on a risk analysis protection measures against direct strikes and overvoltages are shown in an overview. The design concept is realized exemplarily for the hybrid-system VATALI on the Greek island Crete. VATALI, not lightning protected at that time, was a victim of a lightning strike in the year 2000 causing destructions and damages of some mechanical and electrical components with costs of approx. 60.000 €. The hardware costs for the protection measures were about 15.000 €: about 50% of the costs are due to protection measures against direct strikes, 50% are due to overvoltage protection. KW - Blitzschutz KW - Erneuerbare Energien KW - Hybridsystem KW - Photovoltaikanlage KW - Windenergieanlage KW - Lightning protection KW - renewable energy KW - hybrid system KW - photovoltaic system KW - wind turbine Y1 - 2002 ER - TY - CHAP A1 - Zischank, Wolfgang J. A1 - Heidler, Fridolin A1 - Kern, Alexander A1 - Metwally, I. A. A1 - Wiesinger, J. A1 - Seevers, M. T1 - Laboratory simulation of direct lightning strokes to a modelled building - measurement of magnetic fields and induced voltages N2 - In IEC 61312-2 equations for the assessment of the magnetic fields inside structures due to a direct lightning strike are given. These equations are based on computer simulations for shields consisting of a single-layer steel grid of a given mesh width. Real constructions, however, contain at least two layers of reinforcement steel grids. The objective of this study was to experimentally determine the additional shielding effectiveness of a second reinforcement layer compared to a single-layer grid. To this end, simulated structures were set up in the high current laboratory. The structures consisted of cubic cages of 2 m side length with one or with two reinforcement grids, respectively. The structures were exposed to direct lightning currents representing the variety of anticipated lightning current waveforms. The magnetic fields and their derivatives at several positions inside the structure as well as the voltage between “floor” and “roof” in the center were determined for different current injection points. From these data the improvement of the shielding caused by a second reinforcement layer is derived. KW - Direkter Blitzschlag KW - Elektromagnetischer Schutzschild KW - Magnetische Felder KW - Induzierte Spannungen KW - Stahlbetonkonstruktion KW - Lightning KW - electromagnetic shielding KW - magnetic field KW - reinforced concrete KW - induced voltage Y1 - 2002 ER - TY - JOUR A1 - Kern, Alexander A1 - Krichel, Frank T1 - Considerations about the lightning protection system of mains independent renewable energy hybrid-systems - practical experiences JF - Journal of electrostatics. 60 (2004), H. 2-4 Y1 - 2004 SN - 0304-3886 N1 - ISSN der E-Ausg.: 0304-3886 SP - 257 EP - 263 ER - TY - JOUR A1 - Kern, Alexander A1 - Zischank, Wolfgang J. A1 - Heidler, Fridolin A1 - Wiesinger, J. [u.a.] T1 - Shielding effectiveness of reinforced concrete cable ducts carrying partial lightning currents JF - Conference proceedings : 14th - 18th September 1998, [Burlington Hotel, Birmingham, United Kingdom] / organised by: School of Engineering and Advanced Technology, Staffordshire University, United Kingdom Y1 - 1998 N1 - International Conference on Lightning Protection <24, 1998, Birmingham> ; School of Engineering and Advanced Technology ; ICLP <4, 1998, Birmingham> CY - Birmingham ER - TY - JOUR A1 - Kern, Alexander A1 - Thomsen, M. T1 - Comparison of single point and equipotential bonding for I&C systems of large-area industrial sites JF - Volume of proceedings : Budapest, Hungary, September 19-23, 1994 / organized by: Technical University of Budapest Y1 - 1994 N1 - International Conference on Lightning Protection <22, 1994, Budapest> ; ICLP <22, 1994, Budapest> ; Budapesti Műszaki Egyetem PB - Techn. Univ. CY - Budapest ER - TY - JOUR A1 - Kern, Alexander A1 - Drumm, F. T1 - Survey of the lightning threat for aircraft based on natural lightning data and fixed in the German Standard DIN VG 95371 / Part 10 JF - Proceedings of the 1994 International Aerospace and Ground Conference on Lightning and Static Electricity : May 14 - 27, 1994, Bundesakademie für Wehrverwaltung und Wehrtechnik Mannheim ; final report / [conference chairman Jan Luiken TerHaseborg] Y1 - 1994 N1 - International Aerospace and Ground Conference on Lightning and Static Electricity <16, 1994, Mannheim> PB - Bundesakad. für Wehrverwaltung und Wehrtechnik CY - Mannheim ER - TY - JOUR A1 - Kern, Alexander A1 - Roth, J. A1 - Wiedmann, J. T1 - Comparison of the damage for various types of fibre reinforced composites due to different lightning test standards (MIL-STD 1757 A, German military VG-standard 96903) JF - Proceedings of the 1992 International Aerospace and Ground Conference on Lightning and Static Electricity : October 6-8, 1992, Trump Taj Mahal, Atlantic City, NJ. Y1 - 1992 N1 - International Conference on Lightning and Static Electricity <1992, Atlantic City, NJ> PB - U.S. Dept. of Transportation, Federal Aviation Administration CY - [Atlantic City, N.J.] ER - TY - JOUR A1 - Kern, Alexander A1 - Zischank, Wolfgang J. T1 - The effect of parallel wires on the longitudinal voltage drop along shielded cables JF - Conference proceedings : 21st International Conference on Lightning Protection, Berlin Congress Center (BCC) Germany, September 22 - 25, 1992 = 21. Internationale Blitzschutzkonferenz / [proceedings ed. staff: J. Pilling ...] Y1 - 1992 SN - 3-8007-1885-5 N1 - International Conference on Lightning Protection <21, 1992, Berlin> ; ICLP <21, 1992, Berlin> PB - VDE-Verl. CY - Berlin [u.a.] ER - TY - JOUR A1 - Kern, Alexander A1 - Wiesinger, J. A1 - Zischank, Wolfgang J. T1 - Calculation of the longitudinal voltage along metal tubes caused by lightning currents and protection measures JF - Seventh International Symposium on High Voltage Engineering : Dresden, August 26 - 30 1991 Y1 - 1991 N1 - International Symposium on High Voltage Engineering <7, 1991, Dresden> PB - Techn. Univ. CY - Dresden ER - TY - JOUR A1 - Kern, Alexander T1 - Simulation and measurement of melting effects on metal sheets caused by direct lightning strikes JF - 1991 International Aerospace and Ground Conference on Lightning and Static Electricity : proceedings of a conference ... held at Cocoa Beach, Florida, April 16-19, 1991 / NASA Y1 - 1991 N1 - International Aerospace and Ground Conference on Lightning and Static Electricity <1991, Cocoa Beach, Fla.> ; United States / National Aeronautics and Space Administration CY - Washington, DC ER - TY - JOUR A1 - Kern, Alexander T1 - The heating of metal sheets caused by direct lightning strikes-model and measurement JF - 20th ICPL / International Conference on Lightning Protection, Congress-Center Casino Interlaken, Switzerland, September 24-28, 1990 = Internationale Blitzschutzkonferenz, Congress-Center Casino Interlaken, Schweiz, 24.-28. September 1990 Y1 - 1990 N1 - International Conference on Lightning Protection <20, 1990, Interlaken> ; Internationale Blitzschutzkonferenz <20, 1990, Interlaken> PB - Schweizerischer Elektrotechnischer Verein CY - [Zürich] ER - TY - JOUR A1 - Zischank, Wolfgang J. A1 - Heidler, Fridolin A1 - Wiesinger, J. A1 - Metwally, I. A1 - Kern, Alexander A1 - Seevers, M. T1 - Laboratory simulation of direct lightning strokes to a modeled building : measurement of magnetic fields and included voltages JF - Journal of electrostatics. 60 (2004), H. 2 - 4 Y1 - 2004 SN - 0304-3886 N1 - ISSN der E-Ausg.: 0304-3886 SP - 223 EP - 232 ER - TY - JOUR A1 - Kern, Alexander A1 - Heidler, Fridolin A1 - Zischank, Wolfgang J. A1 - Frentzel, Ralf T1 - Lightning current distribution and coupling to control cables in power plants or large industrial facilites Y1 - 2002 N1 - International Conference on Grounding and Earthing <2002, Rio de Janeiro> ER - TY - JOUR A1 - Kern, Alexander A1 - Krichel, Frank A1 - Neskakis, Apostolos A1 - Müller, Klaus-Peter (u.a.) T1 - Lightning protection design of a renewable energy hybrid-system without power mains connection Y1 - 2001 N1 - International Conference on Renewable Energies for Islands <2001, Crete> ER - TY - JOUR A1 - Kern, Alexander T1 - Time dependent temperature distribution in metal sheets caused by direct lightning strikes JF - Proceedings / Sixth International Symposium on High Voltage Engineering : 28. August - 1. September, 1989, Westin Canal Place Hotel, New Orleans, Louisiana, USA Y1 - 1989 N1 - International Symposium on High Voltage Engineering <6, 1989, New Orleans, La.> PB - Mississippi State University CY - Mississippi State, Miss. ER -