TY - JOUR A1 - Helsper, Christoph T1 - Kondensationskernzähler und ihre Anwendung in der Reinraumtechnik JF - Swiss Chem. 8 (1986) Y1 - 1986 SN - 0251-1703 SP - 63 EP - 66 ER - TY - JOUR A1 - Helsper, Christoph T1 - Integritätsprüfung an LF-Anlagen mit Hilfe von Prüfaerosolen JF - Pharma-Technologie-Journal. 14 (1993), H. 2 Y1 - 1993 SN - 0931-9700 SP - 36 EP - 42 ER - TY - JOUR A1 - Helsper, Christoph T1 - Probleme der Staubprobenahme bei der Filterprüfung JF - Filtrieren und Separieren (1995) Y1 - 1995 SN - 0933-5927 SP - 5 EP - 13 ER - TY - JOUR A1 - Helsper, Christoph T1 - Partikelmesstechnik JF - Reinraumtechnik , Hrsg.: Gail, Lothar Y1 - 2002 SN - 3-540-66885-3 SP - 57 EP - 82 PB - Springer CY - Berlin [u.a.] ER - TY - JOUR A1 - Helsper, Christoph T1 - Messverfahren zur Charakterisierung der Abscheidung luftgetragener Partikel in Filtern JF - Schutzmaßnahmen vor mikrobiellen Belastungen des Innenraumes / VII. Lübecker Fachtagung für Umwelthygiene. [Hrsg.:] Reinhard Keller ... Y1 - 2003 N1 - Lübecker Fachtagung für Umwelthygiene <7, 2003, Lübeck> SP - 35 EP - 61 PB - Inst. f. Medizinische Mikrobiologie u. Hygiene d. Med. Univ. CY - Lübeck ER - TY - JOUR A1 - Helsper, Christoph T1 - Kondensationskernzähler in der Reinraummeßtechnik - Meßbereichsgrenzen nach unten verschoben JF - Reinraumtechnik. 5 (1988) Y1 - 1988 SP - 36 EP - 39 ER - TY - JOUR A1 - Helsper, Christoph A1 - Bartz, H. T1 - Theoretische Bestimmung des Abscheidegrades eines Filters bei verschiedenen Betriebszuständen / Bartz, H. ; Helsper, C. JF - Staub, Reinhaltung der Luft. 47 (1987) Y1 - 1987 SN - 0039-0771 SP - 112 EP - 114 ER - TY - BOOK A1 - Helsper, Christoph A1 - Beßling, Harro A1 - Kiock, R. A1 - Fißan, H. J. T1 - Experimentelle Untersuchung der Partikelanzahlkonzentration im Windkanal für den Einsatz von laseranemometrischen Verfahren / Beßling, Harro; Kiock, R.; Helsper, C.; Fißan, H. J. Y1 - 1979 N1 - Deutsche Forschungs- und Versuchsanstalt für Luft- und Raumfahrt (Köln). Forschungsbericht. 79-28. PB - DFVLR CY - Köln ER - TY - CHAP A1 - Helsper, Christoph A1 - Dressler, Jörg ED - Gail, Lothar ED - Gommel, Udo ED - Hortig, Hans-Peter T1 - Partikelmesstechnik T2 - Reinraumtechnik N2 - Der Schutz von Produkten vor der Kontamination durch Partikel gilt als eine zentrale Aufgabe der Reinraumtechnik. Da es dabei um Kontaminationseffekte weit unterhalb der visuellen Wahrnehmbarkeit geht, braucht es leistungsfähige Verfahren, um die Messgröße „Partikelkontamination“ über den gesamten Bereich, den Anwender fordern, präzise zu bestimmen. Neben der Partikelhäufigkeit ist dabei die Größe der Partikel, die sowohl das Transportverhalten wie auch die mögliche Wirkung auf das Produkt beeinflusst, von entscheidender Bedeutung. Ferner kann es für die Ermittlung von Kontaminationsquellen von Interesse sein, die Form und die chemische Natur der Partikel zu bestimmen (z. B. textile Fasern, Metallabrieb, flüssige Tröpfchen). Die Partikelhäufigkeit wird üblicherweise als Konzentration, d. h. bezogen auf das analysierte Gasvolumen angegeben. Bei den in reinen Technologien üblichen niedrigen Konzentrationen dient als Häufigkeitsmaß die Partikelanzahlkonzentration, also die Partikelanzahl pro Volumeneinheit des Trägermediums. Y1 - 2012 SN - 978-3-642-19435-1 U6 - http://dx.doi.org/10.1007/978-3-642-19435-1_3 VL - 2012 SP - 69 EP - 95 PB - Springer CY - Berlin ET - 3 ER - TY - JOUR A1 - Helsper, Christoph A1 - Fißan, H. J. T1 - Techniken zur Kalibrierung von Staubmeßgeräten / Fißan, H. J.; Helsper, C. JF - Schwebstoffe und Stäube : analyt. u. techn. Aspekte ; Kolloquium Nürnberg 1981 Y1 - 1982 SN - 3-18-090429-1 N1 - VDI Berichte; 429 SP - 59 EP - 64 PB - VDI-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Helsper, Christoph A1 - Fißan, H. J. T1 - Zur Reaktion von Rauchdetektoren auf Brandkenngrößen / Fißan, H. J.; Helsper, C. JF - Tagungsbericht zum Internationalen Vortragsseminar über Probleme der automatischen Brandent-deckung / Institut für Elektrische Nachrichtentechnik. Technische Hochschule Aachen ; Fachgebiet Nachrichtentechnik. Universität Duisburg, Gesamthochschule . 8. Internationales Vortragsseminar "AUBE 82" Y1 - 1982 SP - 20 EP - 37 CY - Duisburg ER - TY - JOUR A1 - Helsper, Christoph A1 - Fißan, H. J. A1 - Franzen, H. T1 - Bestimmung der Größenverteilung von Aerosolen aus Verbrennungsvorgängen mit einem elektrostatischen Aerosolanalysator JF - Aerosole in Naturwissenschaft, Medizin und Technik : Bericht der Tagung der Gesellschaft für Aerosolforschung e.V. 4, 1976 Y1 - 1976 SP - 118 EP - 126 ER - TY - JOUR A1 - Helsper, Christoph A1 - Fißan, H. J. A1 - Kasper, W. T1 - Kalibrierung der Partikelgrößenbestimmung von optischen Partikelzählern / Fißan, H. J.; Helsper, C. ; Kasper, W. JF - 3. Europäisches Symposion Partikelmeßtechnik : [PARTEC, eine Veranstaltung der Reihe Partikel-Technologie Nürnberg ; Nürnberg, 9. - 11. Mai 1984 ; preprints] = 3. European Symposium on Particle Characterization / Veranst.: GVC, Gesellschaft Verfahrenstechnik und Chemieingenieurwesen im Verein Deutscher Ingenieure (VDI). Red. Bearb.: Kurt Leschonski Y1 - 1984 N1 - Europäisches Symposion Partikelmesstechnik <3, 1984, Nürnberg> ; PARTEC <1984, Nürnberg> SP - 263 EP - 274 PB - NMA Nürnberger Messe- und Ausstellungsges. CY - Nürnberg ER - TY - BOOK A1 - Helsper, Christoph A1 - Fißan, Heinz A1 - Ahrens, Werner T1 - Entwicklung eines Meßsystems zur direkten Bestimmung der Partikelgrößenverteilung von Aerosolen aus Verbrennungsvorgängen / Fißan, Heinz; Helsper, Christoph; Ahrens, Werner Y1 - 1979 SN - 3-531-02827-8 N1 - Forschungsberichte des Landes Nordrhein Westfalen, Nr. 2827 PB - Westdeutscher Verl. CY - Opladen ER - TY - JOUR A1 - Helsper, Christoph A1 - Mölter, W. T1 - Determination and Neutralization of the Charge Produced by the Dispersion of Powders JF - Journal of Aerosol Science. 18 (1987), H. 6 Y1 - 1987 SN - 0021-8502 SP - 877 EP - 880 ER - TY - JOUR A1 - Helsper, Christoph A1 - Mölter, W. A1 - Kaminski, S. T1 - Automatisierter Test von Luftfiltermedien für Hochleistungsschwebstoffilter und Entstaubungsfilter / Mölter, W. ; Helsper, C. ; Kaminski, S. JF - Staub, Reinhaltung der Luft. 50 (1990) Y1 - 1990 SN - 0039-0771 SP - 311 EP - 317 ER - TY - JOUR A1 - Helsper, Christoph A1 - Mölter, W. A1 - Mölter, L. T1 - Korngrößenanalyseverfahren für trockene Pulver und Stäube von 0,5-25 µm JF - Chemie-Technik. 16 (1986) Y1 - 1986 SN - 0340-9961 SP - 140 EP - 144 ER - TY - JOUR A1 - Herrmann, Ulf A1 - Schwarzenbart, Marc A1 - Dittmann-Gabriel, Sören T1 - Speicher statt Kohle. Integration thermischer Stromspeicher in vorhandene Kraftwerksstandorte JF - BWK : Das Energie-Fachmagazin Y1 - 2019 SN - 1436-4883 VL - 71 IS - 4 SP - 42 EP - 45 PB - Springer-VDI-Verl. CY - Düsseldorf ER - TY - BOOK A1 - Hodapp, Josef T1 - Die direkte Selbst-Regelung einer Asynchronmaschine mit einem Signalprozessor Y1 - 1989 SN - 3-18-147508-4 N1 - Zugl.: Bochum, Univ., Diss., 1988 ; Fortschritt-Berichte VDI : Reihe 8 ; 175 PB - VDI-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Hoffschmidt, Bernhard T1 - Keramische Mischer : Überhitzung ausgeschlossen JF - Nachrichten : Magazin des Deutschen Zentrums für Luft- und Raumfahrt / DLR (2000) Y1 - 2000 SN - 0937-0420 SP - 26 EP - 27 ER - TY - BOOK A1 - Hoffschmidt, Bernhard T1 - Vergleichende Bewertung verschiedener Konzepte volumetrischer Strahlungsempfänger. - (Forschungsbericht / Deutsches Zentrum für Luft- und Raumfahrt e.V. ; 1997,35) Y1 - 1997 SN - 1434-8454 N1 - Zugl.: Aachen, Techn. Hochsch., Diss. ; Reportnr.: DLR FB 97 35 PB - DLR CY - Köln ER - TY - JOUR A1 - Hoffschmidt, Bernhard T1 - Das Solar-Institut Jülich an der Fachhochschule Aachen JF - Regenerative Energien in Deutschland und in Polen : Aspekte im Hinblick auf den EU-Beitritt Polens ; 6./7. Mai 2004, Lodz/Polen ; Tagungsband / VDI-Gesellschaft Energietechnik. 1. - Aufl. Y1 - 2004 SN - 3-931384-47-0 SP - 277 EP - 280 PB - VDI-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Hoffschmidt, Bernhard T1 - Jenseits von Spanien. Das Solarthermische Versuchs- und Demonstrationskraftwerk Jülich (STJ) JF - DLR-Nachrichten (2008) Y1 - 2008 SN - 0937-0420 N1 - Sonderheft Energie SP - 38 EP - 39 ER - TY - JOUR A1 - Hoffschmidt, Bernhard A1 - Koll, Gerrit T1 - Die Zukunft der Stromerzeugung ; die Entwicklung der Luftreceivertechnologie bei Kraftanlagen München / Gerrit Koll ; Berhard Hoffschmidt JF - Nachrichten : Magazin des Deutschen Zentrums für Luft- und Raumfahrt / DLR (2005) Y1 - 2005 SN - 0937-0420 N1 - Sonderheft Solarforschung SP - 42 EP - 46 ER - TY - JOUR A1 - Hoffschmidt, Bernhard A1 - Krödel, Matthias A1 - Geigl, Florian T1 - Die Kraft der Sonne / Matthias Krödel ; Florian Geigl ; Bernhard Hoffschmidt JF - Nachrichten : Magazin des Deutschen Zentrums für Luft- und Raumfahrt / DLR (2002) Y1 - 2002 SN - 0937-0420 SP - 18 EP - 19 ER - TY - BOOK A1 - Hoffschmidt, Bernhard A1 - Lan, Marco A1 - Fricke, Barbara A1 - Anthrakidis, Anette A1 - Peter, Stefan T1 - Struktur und Dynamik einer Stromversorgung mit einem hohen Anteil erneuerbarer Energieerzeuger. Kurzbezeichnung: Energiestudie. Schlussbericht Y1 - 2010 N1 - BMU-Forschungsbericht. Bundesministerium für Umwelt, Naturschutz und Reaktorsicherheit / 2010 / 20110602205 PB - Solar-Institut, FH Aachen CY - Jülich ER - TY - JOUR A1 - Hoffschmidt, Bernhard A1 - Pitz-Paal, R. A1 - Hennecke, K. T1 - Solare Heißlufterzeugung für Temperaturen bis über 250 Grad C JF - Tagung München, 16. und 17. März 1999 . 1999. - (VDI-Berichte ; 1457) Y1 - 1999 SN - 3-18-091457-2 SP - 323 EP - 332 PB - VDI-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Holtschoppen, B. A1 - Butenweg, Christoph A1 - Meskouris, Konstantin T1 - Erdbebensichere Auslegung von Industrieanlagen JF - Der Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen ; offizielle Zeitschrift der VDI-Gesellschaft Bautechnik Y1 - 2009 SN - 0005-6650 IS - März SP - S9 EP - S14 PB - VDI Fachmedien CY - Düsseldorf ER - TY - CHAP A1 - Holtschoppen, Britta A1 - Cornelissen, Philipp A1 - Butenweg, Christoph A1 - Meskouris, Konstantin T1 - Vereinfachtes Berechnungsverfahren zur Berücksichtigung der Interaktionsschwingung bei flüssigkeitsgefüllten Tankbauwerken unter seismischer Belastung T2 - Berichte der Fachtagung Baustatik-Baupraxis 11 : am 21. und 22. Februar 2011 an der Universität Innsbruck / Hrsg. Gernot Beer ... Y1 - 2011 SN - 978-3-85125-115-9 SP - 155 EP - 162 PB - Inst. für Baustatik, Techn. Univ. Graz CY - Graz ER - TY - BOOK A1 - Hoyler, Friedrich T1 - Untersuchung der (p,alpha)-Reaktion an Kernen der sd-Schale und ihre mikroskopische Analyse Y1 - 1982 N1 - Tübingen, Univ., Diss., 1982 CY - Tübingen ER - TY - JOUR A1 - Ille, F. A1 - Schramm, S. A1 - Adam, M. A1 - Backes, K. A1 - Faber, Christian A1 - Anthrakidis, Anette T1 - Kraft-Wärme-Kälte-Kopplung im Leistungsbereich von 10 kW mit periodisch arbeitender Sorptionsmaschine JF - VDI-Tage der Gebäudetechnik 2008 : Tagung Dortmund, 28. und 29. Mai 2008 / VDI-Gesellschaft Technische Gebäudeausrüstung Y1 - 2008 SN - 978-3-18-092043-6 N1 - VDI-Berichte ; 2043 ; 2. VDI-Tage der Gebäudetechnik 2008, VDI-Gesellschaft Technische Gebäudeausrüstung (VDI-TGA), Dortmund, DE, 28.-29. Mai, 2008 SP - 103 EP - 116 PB - VDI-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Jellinghaus, Sabine A1 - Göttsche, Joachim A1 - Hoffschmidt, Bernhard T1 - Beleuchtung mit gesteuertem Farblicht - Bewertung eines Prototypen JF - Zwölftes Symposium Innovative Lichttechnik in Gebäuden : 26./27. Januar 2006, Kloster Banz, Bad Staffelstein / OTTI - Training, Seminare, Tagungen. [Fachliche Gesamtleitung: Claus Steffan. Veranst.: OTTI, Bereich Erneuerbare Energien. Mitveranst.: Architektenkammer Baden-Württemberg, Stuttgart ...] / . - (Wissen für Profis) Y1 - 2006 SN - 3-934681-43-3 N1 - Symposium Innovative Lichttechnik in Gebäuden <12, 2006, Kloster Banz> ; Ostbayerisches Technologie-Transfer-Institut / Bereich Erneuerbare Energien SP - 89 EP - 93 PB - OTTI, Bereich Erneuerbare Energien CY - Regensburg ER - TY - CHAP A1 - Jordan, Frank A1 - Katz, Christiane A1 - Pieper, Martin T1 - Online-Kollaboration in der Mathematik: Ein Design-Based-Research-Projekt T2 - Forschungsimpulse für hybrides Lehren und Lernen an Hochschulen N2 - Die Studie erörtert anhand eines Fallbeispiels aus der Mathematik für Ingenieur*innen, wie didaktische Gestaltungsprinzipien für Soziale Präsenz, Kollaboration und das Lösen von praxisnahen Problemen mit mathematischem Denken in einer Online-Umgebung aussehen können. Hierfür zieht der Beitrag den forschungsmethodologischen Rahmen Design-Based Research (DBR) hinzu und berichtet über Zwischenergebnisse. DBR wird an dieser Stelle als eine systematische Herangehensweise an kurzfristige Lehrveränderungen und als Chance auf dem Weg zu einer neuen Hochschullehre nach der COVID-19-Pandemie dargestellt, die theoretische und empirische Erkenntnisse mit Praxisverknüpfung und -relevanz vereint. Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:832-cos4-9465 SP - 245 EP - 261 PB - TH Köln CY - Köln ER - TY - JOUR A1 - Jungbluth, Christian A1 - Borchert, Jörg T1 - Möglichkeiten der Strompreisbeeinflussung im oligopolistischen Markt JF - ZNER Zeitschrift für Neues Energierecht Y1 - 2008 IS - 4 SP - 314 EP - 323 ER - TY - CHAP A1 - Karvanek, Eva A1 - Butenweg, Christoph A1 - Ebenau, Carsten T1 - Bautechnische Prüfung und Bauüberwachung der Arena „Auf Schalke“ T2 - Berichte der Fachtagung Baustatik - Baupraxis 8 am 21. und 22. März 2002 in Braunschweig / Hrsg. Dieter Dinkler Y1 - 2002 SN - 3-926031-95-6 SP - 237 EP - 245 PB - TU Braunschweig, Institut für Statik CY - Braunschweig ER - TY - CHAP A1 - Kaspar, K. A1 - Groebel, Simone A1 - Kuperjans, Isabel A1 - Dielmann, Klaus-Peter A1 - Selmer, Thorsten T1 - Charakterisierung der Biozönose von Biogasfermentern in Abhängigkeit verschiedener Substrate T2 - Biogas 2013 : 6. Innovationskongress, 23. - 24.05.2013, Osnabrück, Tagungsband Y1 - 2013 SN - 978-3-9813776-3-7 SP - 69 EP - 74 PB - Profair Consult+Project CY - Hildesheim ER - TY - GEN A1 - Kaster, Jan Mathis T1 - Untersuchungen zur Specklereduktion bei der Infrarot-Laser gestützten Ferndetektion von TNT-Oberflächenkontaminationen T1 - Studies on specklereduction in the infrared laser based remote detection of TNT surface contaminations N2 - Das Ziel der vorliegenden Arbeit ist die Specklereduktion bei der Infrarotlaser-gestützten abbildenden Ferndetektion von TNT-Oberflächenkontaminationen. Für die Detektion wird die Probenoberfläche mit einem abstimmbaren Quantenkaskadenlaser bei verschiedenen Wellenzahlen im Spektralbereich von 1340cm-1 bis 1380cm-1 bestrahlt, während eine Infrarot-Kamera Bilder der bestrahlten Fläche aufzeichnet. Diese Bilder werden dann so verarbeitet, dass im Ausgabebild die chemisch spezifische TNT-Absorption durch eine Änderung der Helligkeit örtlich aufgelöst erkennbar werden. Da kohärente Strahlung, welche beispielsweise an optisch rauen Oberflächen reflektiert wird, aufgrund der stochastischen Verteilung der Oberflächenrautiefe mit der einfallenden Strahlung lateral unterschiedlich interferiert, entsteht ein „Rauschen“ in der aufgezeichneten Strahlungsleistungsverteilung, das sog. Speckle-Phänomen. Die Empfindlichkeit der oben skizzierten Lasergestützten Messtechnik wird im Wesentlichen durch diesen Effekt limitiert. Um die durch Laserspeckles verursachten Rauschanteile zu reduzieren, gibt es verschiedene Möglichkeiten. Durch Reduktion von zeitlicher und räumlicher Kohärenz der Strahlung wird deren Interferenzfähigkeit reduziert und durch Variieren des Specklemusters während einer Bildaufzeichnung führen Mittelungen unkorrelierter Rauschanteile zu einer Specklekontrastreduktion. Letztere Möglichkeit resultiert daraus, dass Laserspeckles statistisch durch die Familie der Gammaverteilungen beschrieben werden können. Demnach verbessert sich das Signal-zu-Rausch-Verhältnis mit der Anzahl gemittelter, unkorrelierter Rauschmuster proportional zur Wurzel dieser Anzahl. Ein im MIR-Spektralbereich umsetzbarer Ansatz, der all diese Möglichkeiten berücksichtigt, wurde bereits 1971 von Lowenthal und Joyeaux vorgeschlagen und im Rahmen der vorliegenden Arbeit für den infraroten Spektralbereich adaptiert. Dazu wird die Strahlung mit zwei CVD-Diamant-Wafern moduliert; ein Wafer ist dabei stationär und der andere rotiert mit ca. 70Hz. In der vorliegenden Arbeit konnte mit diesem Ansatz eine Verbesserung des Signal-zu-Rausch-Verhältnisses in der betrachteten Strahlungsleistungs¬verteilung von ursprünglich 3 auf etwa 45 erzielt werden. So konnten erstmals TNT-Kontaminationen von bis zu 10µg/cm² in einem Abstand von 5m abbildend nachgewiesen werden. Dies entspricht der Kontamination durch einen mit TNT leicht verunreinigten Fingerabdruck. KW - Speckle KW - Infrarot-Reflexions-Absorptions-Spektroskopie KW - MIR-Spektroskopie KW - Infrarotmesstechnik KW - Quantenkaskadenlaser KW - Fernerkundung KW - Trinitrotol Y1 - 2009 ER - TY - BOOK A1 - Kern, Alexander T1 - Blitz- und Überspannungsschutz für Anlagen der regenerativen Energietechnik Y1 - 2004 PB - Fachhochschule Aachen, Abt. Jülich CY - Aachen ER - TY - JOUR A1 - Kern, Alexander T1 - Beispiele für EMV-Maßnahmen in großflächigen Anlagen JF - EMV von Gebäuden, Anlagen und Geräten : praktische Umsetzung der technischen, wirtschaftlichen und gesetzlichen Anforderungen für die CE-Kennzeichnung / Anton Kohling (Hrsg.). Gerd Balzer... Y1 - 1998 SN - 3-8007-2261-5 PB - VDE-Verl. CY - Berlin [u.a.] ER - TY - BOOK A1 - Kern, Alexander T1 - Theoretische und experimentelle Untersuchung der Erwärmung von Metallblechen bei Blitzeinschlag Y1 - 1990 N1 - Diss. PB - Univ. der Bundeswehr CY - München ER - TY - JOUR A1 - Kern, Alexander T1 - Physik der Blitzentladung und Blitzstrom-Parameter bei natürlichen Blitzen Y1 - 1993 N1 - Wehrtechnisches Symposium Elektromagnetische Verträglichkeit <5, 1993, Mannheim> ER - TY - JOUR A1 - Kern, Alexander T1 - Blitz-Störschutz als Maßnahme der EMV am Beispiel einer ausgedehnten Industrieanlage Y1 - 1995 N1 - Forum für Sachverständige, Fa. Dehn + Söhne <2, 1995, Nürnberg> ER - TY - JOUR A1 - Kern, Alexander T1 - Blitz-Schutzzonen mit Schirmungen und Schnittstellen JF - Blitzschutz für Gebäude und elektrische Anlagen : Vorträge der VDE/ABB-Fachtagung am 29. Februar und 1. März 1996 in Kassel / Veranst.: Ausschuß Blitzschutz und Blitzforschung (ABB) im VDE-Verband Dt. Elektrotechniker e.V. Wiss. Tagungsleit.: F. Noack. - (Verband Deutscher Elektrotechniker: VDE-Fachbericht ; 49) Y1 - 1996 SN - 3-8007-2161-9 N1 - Blitzschutztagung <1, 1996, Kassel> ; Verband Deutscher Elektrotechniker / Ausschuss für Blitzschutz und Blitzforschung PB - VDE-Verl. CY - Berlin [u.a.] ER - TY - JOUR A1 - Kern, Alexander T1 - Ertüchtigung des Blitzschutzsystems für ein Bürogebäude auf der Basis von VDE V 0185 Teil 100 (ENV 61024-1) und VDE 0185 Teil 103 (IEC 1312-1) Y1 - 1998 N1 - Forum Verband Deutscher Blitzschutzfirmen e.V. <1998, Köln> ER - TY - JOUR A1 - Kern, Alexander T1 - Aktueller Stand zu Risikoabschätzungen bei Blitzeinschlägen - Was ist neu in der IEC 61662 Edition 2? Y1 - 2000 N1 - Forum Verband Deutscher Blitzschutzfirmen e.V. <2000, Köln> ER - TY - JOUR A1 - Kern, Alexander T1 - Neue deutsche Blitzschutz-Normung. Reihe DIN EN 62305 / VDE 01 85-305-x:2006 JF - Der Eisenbahningenieur. 58 (2007), H. 8 Y1 - 2007 SN - 0013-2810 N1 - in der Bereichsbibliothek Bayernallee vorhanden SP - 18 EP - 22 ER - TY - JOUR A1 - Kern, Alexander T1 - Die neuen Blitzschutznormen der Reihe DIN EN 62305 (VDE 0185-305-x) JF - ETZ : Elektrotechnik + Automation. 2006 (2006), H. 2 Y1 - 2006 SN - 0170-1711 N1 - 2. ISSN: 0948-7387 ; In der Bibliothek unter 23 Z 133 (Eupener Str.) und 63 ZS 035 (Jülich) vorhanden. SP - 42 EP - 45 ER - TY - JOUR A1 - Kern, Alexander T1 - Überarbeitung der Blitzschutznorm IEC 62305 JF - Elektropraktiker. 63 (2009), H. 4 Y1 - 2009 SN - 0013-5569 SP - 391 EP - 394 ER - TY - CHAP A1 - Kern, Alexander T1 - Die neue DIN EN 62305-2 (VDE 0185-305-2) Ed.2:2013-02 - Änderungen zur Ed.l und zugehörige Beiblätter T2 - 10. VDE, VBB-Blitzschutztagung : Vorträge der 10. VDE, ABB-Fachtagung vom 24. bis 25. Oktober 2013 in Neu-Ulm. (VDE-Fachbericht ; 70) Y1 - 2013 SN - 978-3-8007-3540-2 SP - 9 EP - 16 PB - VDE-Verl. CY - Berlin ER - TY - CHAP A1 - Kern, Alexander T1 - Abschätzung des Blitzschadensrisikos für bauliche Anlagen - Die neue Bestimmung DIN V VDE V 0185 Teil 2 : 2002 - Allgemeines, Abschätzungsverfahren, Berechnungsbeispiele N2 - Ein vorausschauendes Risikomanagement beinhaltet, Risiken für das Unternehmen zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent, welche Risiken sinnvollerweise über Versicherungen abgedeckt werden sollten. Beim Versicherungsmanagement ist jedoch zu bedenken, dass zur Erreichung bestimmter Ziele Versicherungen nicht immer geeignet sind (z.B. Erhaltung der Lieferfähigkeit). Eintrittswahrscheinlichkeiten bestimmter Risiken lassen sich durch Versicherungen nicht verändern. Bei Unternehmen, die mit umfangreichen elektronischen Einrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Berücksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nicht-Verfügbarkeit der elektronischen Einrichtungen und damit der Produktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardware-Schaden an der betroffenen Anlage oft bei weitem übersteigt. Im Blitzschutz gewinnt innovatives Denken in Schadensrisiken langsam an Bedeutung. Risikoanalysen haben die Objektivierung und Quantifizierung der Gefährdung von baulichen Anlagen und ihrer Inhalte durch direkte und indirekte Blitzeinschläge zum Ziel. Seinen Niederschlag hat dieses neue Denken in der neuen deutschen Vornorm DIN V 0185-2 VDE V 0185 Teil 2 [1] gefunden. Die hier vorgegebene Risikoanalyse gewährleistet, dass ein für alle Beteiligten nachvollziehbares Blitzschutz-Konzept erstellt werden kann, das technisch und wirtschaftlich optimiert ist, d.h. bei möglichst geringem Aufwand den notwendigen Schutz gewährleisten kann. Die sich aus der Risikoanalyse ergebenden Schutzmaßnahmen sind dann in den weiteren Normenteilen der neuen Reihe VDE V 0185 [2, 3] detailliert beschrieben. KW - Blitzschutz KW - Risikomanagement KW - Risikoabschätzung KW - Lightning protection KW - Risk management KW - Risk assessment Y1 - 2003 ER - TY - JOUR A1 - Kern, Alexander T1 - Risikomanagement für den Blitzschutz - Abschätzung des Blitzschadensrisikos nach der neuen Vornorm VDE V 0185 Teil 2 : 2002 N2 - Ein vorausschauendes Risikomanagement beinhaltet, Risiken zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent,welche Risiken sinnvoll über Versicherungen abgedeckt werden sollten. Bei Unternehmen, die mit umfangreichen elektronischenEinrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Berücksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nichtverfügbarkeit der elektronischen Einrichtungen und damit derProduktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardwareschaden an der betroffenen Anlage oft bei weitem übersteigt. KW - Blitzschutz KW - Risikomanagement KW - Risikoabschätzung KW - Lightning protection KW - Risk management KW - Risk assessment Y1 - 2003 ER - TY - CHAP A1 - Kern, Alexander T1 - Risikomanagement : Abschätzung des Schadensrisikos für bauliche Anlagen - Die neue Vornorm DIN V VDE V 0185 Teil 2 : 2002 N2 - Alle Unternehmen sind vielfältigen Risiken ausgesetzt, die Finanz- und Betriebsbereiche einschließlich Dienstleistungen betreffen können. Die Firmen müssen üblicherweise Risiken eingehen, um im Wettbewerb bestehen zu können. Entscheidend ist, dass man sich über die Risiken bewusst ist, diese einschätzen und kontrollieren kann. Falsche Einschätzungen, Versäumnisse und Fehlentscheidungen können empfindliche finanzielle Schäden bis hin zum Totalverlust nach sich ziehen. Ein effektives Risikomanagement ist heute als wichtiger Sicherheitsfaktor anzusehen und sollte zur strategischen Unternehmensführung gehören. Ein vorausschauendes Risikomanagement beinhaltet, Risiken für das Unternehmen zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent, welche Risiken sinnvollerweise über Versicherungen abgedeckt werden sollten. Beim Versicherungsmanagement ist jedoch zu bedenken, dass zur Erreichung bestimmter Ziele Versicherungen nicht geeignet sind (z.B. Erhaltung der Lieferfähigkeit). Eintrittswahrscheinlichkeiten bestimmter Risiken lassen sich durch Versicherungen nicht verändern. Bei Unternehmen, die mit umfangreichen elektronischen Einrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Berücksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nicht-Verfügbarkeit der elektronischen Einrichtungen und damit der Produktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardware-Schaden an der betroffenen Anlage oft bei weitem übersteigt. Im Blitzschutz gewinnt innovatives Denken in Schadensrisiken langsam an Bedeutung. Risikoanalysen haben die Objektivierung und Quantifizierung der Gefährdung von baulichen Anlagen und ihrer Inhalte durch direkte und indirekte Blitzeinschläge zum Ziel. Seinen Niederschlag hat dieses neue Denken in der neuen deutschen Norm DIN V 0185-2 VDE V 0185 Teil 2 gefunden. Die hier vorgegebene Risikoanalyse gewährleistet, dass ein für alle Beteiligten nachvollziehbares Blitzschutz-Konzept erstellt werden kann, das technisch und wirtschaftlich optimiert ist, d.h. bei möglichst geringem Aufwand den notwendigen Schutz gewährleisten kann. Die sich aus der Risikoanalyse ergebenden Schutzmaßnahmen sind dann in den weiteren Normenteilen der neuen Reihe VDE V 0185 detailliert beschrieben. KW - Blitzschutz KW - Risikomanagement KW - Risikoabschätzung KW - Versicherung KW - Lightning protection KW - Risk management KW - Risk assessment ; Insurance Y1 - 2002 ER - TY - CHAP A1 - Kern, Alexander T1 - Risikomanagement nach DIN V 0185-2 VDE V 0185 Teil 2: 2002-11 - Einige Beispiele und erste Erfahrungen T1 - Risk management based on DIN V 0185-2 VDE V 0185 part 2: 2002-11 - Some examples and first experiences N2 - Die neue Vornorm VDE V 0185 Teil 2 „Risikomanagement: Abschätzung des Schadensrisikos für bauliche Anlagen“ [1] ist seit November 2002 gültig. Sie ermöglicht nicht nur die Ermittlung der Schutzklasse eines Blitzschutzsystems, sondern auch die Untersuchung zur Notwendigkeit anderer Schutzmaßnahmen gegen Blitzeinwirkungen (Überspannungsschutzgeräte in Unterverteilern und/oder an Endgeräten, Schirmung des Gebäudes und/oder interner Räume, Potentialsteuerung, Brandmelde- und Feuerlöscheinrichtungen, etc.) nach objektiven Kriterien und damit in einer für alle Beteiligten grundsätzlich nachvollziehbaren Art und Weise. Dass eine solche Analyse rel. komplex sein muss und der intensiven Beschäftigung bedarf, ist deshalb nicht verwunderlich. Die Komplexität des Verfahrens sollte allerdings nicht dazu führen, die Vornorm als Ganzes abzulehnen. Die Vornorm beruht auf dem Stand der Diskussion im internationalen Normengremium IEC TC81 WG9 Ende des Jahres 2000. Integriert wurden einige nationale Besonderheiten, die aus Sicht des zuständigen Normenkomitees DKE K251 erforderlich erschienen. In Deutschland konnten und können nun erste breite Erfahrungen in der Anwendung dieser Risikoanalyse gesammelt werden; in anderen Ländern ist dies noch nicht möglich. Diese Erfahrungen können dann, nach Diskussion im nationalen Rahmen, in die internationale Normenarbeit eingebracht werden. Im folgenden Beitrag sollen einige, seit Erscheinen der Vornorm oft wiederkehrende Fragen dargestellt und Lösungsvorschläge vorgestellt werden. Dabei wird auch auf die Tendenzen im internationalen Normengremium IEC TC81 WG9 eingegangen, d.h. auf den aktuellen Entwurf zur IEC 62305-2 [3]. Die Lösungsvorschläge werden begründet, sind allerdings weitestgehend subjektive Meinung des Autors. Für übliche bauliche Anlagen ist die Anwendung der Vornorm rel. einfach möglich. Auch für spezielle Fälle können die darin festgelegten Verfahren herangezogen werden; allerdings sind dann einige weiterführende Überlegungen notwendig, die der Planer von Blitzschutzsystemen durchführen muss. Anhand zweier Beispiele soll die Anwendung der VDE V 0185 Teil 2 auf solche speziellen Fälle dargestellt werden. KW - Blitzschutz KW - Risikomanagement KW - Lightning protection KW - risk management Y1 - 2003 ER - TY - JOUR A1 - Kern, Alexander T1 - Blitz- und Überspannungsschutz von Kernkraftwerken - Nachweisführung der ausreichenden Sicherheit für leittechnische Einrichtungen auch bei Blitzeinschlägen mit extremen Parametern JF - Atw. International Journal for Nuclear Power N2 - Für das Auftreten extremer Wetterereignisse werden für Kernkraftwerke Eintrittshäufigkeiten für nicht mehr beherrschbare Zustände von unter 10⁻⁴/a gefordert. Dies gilt auch für die Einwirkung von Blitzeinschlägen. Die bisherige Nachweisführung zu Blitz- und Überspannungsschutz eines KKW in Deutschland ist deterministisch. In diesem Bericht werden das Vorgehen für einen entsprechenden Nachweis für leittechnische Einrichtungen der Sicherheitstechnik von KKW, der zur geforderten Zielgröße der Eintrittshäufigkeit führt. Die Ergebnisse werden zusammenfassend bewertet. Y1 - 2016 SN - 1431-5254 VL - 61 IS - 8/9 SP - 534 EP - 543 PB - Inforum CY - Berlin ER - TY - CHAP A1 - Kern, Alexander T1 - Optimierung des Blitzschutzes bei Biogasanlagen T1 - Improvement of lightning protection for biogas plants T2 - 12. VDE/ABB-Blitzschutztagung : Beiträge der 12. VDE/ABB-Fachtagung, 12.-13. Oktober 2017, Aschaffenburg Y1 - 2017 SN - 978-3-8007-4459-6 SP - 48 EP - 56 ER - TY - JOUR A1 - Kern, Alexander A1 - Beierl, O. A1 - Zischank, W. T1 - DIN EN 62 305-3 - Berechnung des Trennungsabstands (Anmerkungen zur Anwendung der Berechnungsverfahren und vereinfachte Verfahren zur Abschätzung der Stromaufteilung) / Kern, A. ; Beierl, O. ; Zischank, W. JF - Elektropraktiker. 63 (2009), H. 3 Y1 - 2009 SN - 0013-5569 SP - 218 EP - 222 PB - HUSS-MEDIEN GmbH CY - Berlin ER - TY - CHAP A1 - Kern, Alexander A1 - Beierl, Ottmar A1 - Zischank, Wolfgang T1 - Calculation of the separation distance according to IEC 62305-3: 2006-10 - Remarks for the application and simplified methods N2 - [Paper of the X International Symposium on Lightning Protection 9th - 13th November, 2009 - Curitiba, Brazil. 6 pages] The international standard IEC 62305-3, published in 2006, requires as an integral part of the lightning protection system (LPS) the consideration of a separation distance between the conductors of the LPS and metal and electrical installations inside the structure to be protected. IEC 62305-3 gives two different methods for this calculation: a standard, simplified approach and a more detailed approach, which differ especially regarding the treatment of the current sharing effect on the LPS conductors. Hence, different results for the separation distance are possible, leading to some discrepancies in the use of the standard. The standard approach defined in the main part (Clause 6.3) and in Annex C of the standard in some cases may lead to a severe oversizing of the required separation distance. The detailed approach described in Annex E naturally gives more correct results. However, a calculation of the current sharing amongst all parts of the air-termination and downconductor network is necessary, in many cases requiring the use of network analysis programs. In this paper simplified methods for the assessment of the current sharing are presented, which are easy to use as well as sufficiently adequate. KW - Blitzschutz KW - Lightning protection Y1 - 2009 N1 - Paper in: [10. International Symposium on Lightning Protection 9. 13. November 2009, Curitiba, Brasilien. 6 Seiten] ER - TY - JOUR A1 - Kern, Alexander A1 - Braun, Christian T1 - Neuerungen bei der Blitzschutznorm. Teil 2 JF - etz Elektrotechnik und Automation Y1 - 2013 SN - 0170-1711 N1 - Printausg. in der Bibliothek der FH Aachen vorhanden: 23 Z 133 ; 63 ZS 035 VL - Bd. 134 IS - H. 8 SP - 66 EP - 69 PB - VDE-Verlag CY - Wuppertal ER - TY - CHAP A1 - Kern, Alexander A1 - Brocke, Ralph T1 - Planung von Fangeinrichtungen mit dem dynamischen elektro-geometrischen Modell - Mögliche praktische Anwendungen T1 - Design of air-terminations using the dynamic electro-geometrical model - Possible practical applications T2 - 12. VDE/ABB-Blitzschutztagung : Beiträge der 12. VDE/ABB-Fachtagung, 12.-13. Oktober 2017, Aschaffenburg Y1 - 2017 SN - 978-3-8007-4459-6 SP - 75 EP - 82 ER - TY - JOUR A1 - Kern, Alexander A1 - Dikta, Gerhard T1 - Bewerten von Schäden durch Blitzeinwirkungen JF - Elektropraktiker. 62 (2008), H. 4 Y1 - 2008 SN - 0013-5569 SP - 338 EP - 342 ER - TY - JOUR A1 - Kern, Alexander A1 - Dikta, Gerhard A1 - Krichel, Frank T1 - Zur Wahrscheinlichkeit für Schäden an elektrischen und elektronischen Einrichtungen durch indirekte Blitzeinschläge - Auswertung von Schadensstatistiken, analytischen und numerischen Berechnungen JF - 7. VDE-ABB-Blitzschutztagung : Vorträge der VDE-ABB-Fachtagung vom 15. bis 16. November 2007 in Neu-Ulm / Veranst.: Ausschuss für Blitzschutz und Blitzforschung (ABB) im VDE, Verband der Elektrotechnik, Elektronik, Informationstechnik e.V. Wiss. Tagungsltg.: K. Stimper Y1 - 2007 SN - 978-3-8007-3062-9 N1 - VDE-Fachbericht ; 64 ; Blitzschutztagung <7, 2007, Neu-Ulm> SP - 1 EP - 9 PB - VDE-Verl. CY - Berlin ER - TY - JOUR A1 - Kern, Alexander A1 - Hasse, P. A1 - Wiesinger, J. A1 - Zischank, Wolfgang J. T1 - Aktuelles aus der Blitzforschung JF - ETZ : Elektrotechnik + Automation. 112 (1991), H. 1 Y1 - 1991 SN - 0170-1711 N1 - 2. ISSN: 0948-7387 ER - TY - JOUR A1 - Kern, Alexander A1 - Heidler, Fridolin A1 - Zahlmann, P. A1 - Zischank, Wolfgang J. T1 - Blitzschutz JF - ETZ : Elektrotechnik + Automation. 114 (1993), H. 2 Y1 - 1993 SN - 0170-1711 N1 - 2. ISSN: 0948-7387 ER - TY - JOUR A1 - Kern, Alexander A1 - Kaiser, Ludwig T1 - Auswirkungen des EMVG auf leittechnische Einrichtungen in großflächigen Industrieanlagen / von Ludwig Kaiser ; Alexander Kern JF - ETZ : Elektrotechnik + Automation. 116 (1995), H. 9 Y1 - 1995 SN - 0170-1711 N1 - 2. ISSN: 0948-7387 ; In der Bibliothek unter 23 Z 133 (Eupener Str.) und 63 ZS 035 (Jülich) vorhanden. SP - 16 EP - 18 ER - TY - JOUR A1 - Kern, Alexander A1 - Klöters, Georg A1 - Pferdmenges, Jörg T1 - Blitzschutzoptimierung in der LST an nicht-elektrifizierten Strecken JF - Signal und Draht. 101 (2009), H. 4 Y1 - 2009 SN - 0037-4997 SP - 17 EP - 21 PB - DVV Media Group CY - Hamburg ER - TY - JOUR A1 - Kern, Alexander A1 - Krichel, Frank T1 - Überlegungen zum Blitzschutzkonzept für regenerative Energieanlagen N2 - Dem Blitzschutz von Anlagen der regenerativen Energien kommt in Zukunft eine steigende Bedeutung zu. Dabei ist es notwendig zu berücksichtigen, dass die Schutzmaßnahmen technisch/wirtschaftlich ausgewogen sind. Erbauer, Besitzer oder Benutzer von netzautarken Hybridanlagen haben zu entscheiden, ob die Anlage einen Schutz braucht oder nicht. Um diese Entscheidung zu fällen, ist eine Risikoanalyse als erster Schritt sinnvoll. Diese muss dabei die für die Hybridanlage relevanten Schadenarten und spezifischen Parameter, Werte und Randbedingungen mit einbeziehen. Dazu ist die Hilfe eines Blitzschutzexperten sehr hilfreich. KW - Alternative Energiequelle KW - Energietechnische Anlage KW - Blitzschutz KW - Blitzschutz KW - Regenerative Energieanlagen KW - Lightning protection KW - renewable energy Y1 - 2003 ER - TY - CHAP A1 - Kern, Alexander A1 - Krämer, Heinz-Josef T1 - Blitzschutzkonzept für eine bauliche Anlage mit Stahlkonstruktion und metallenen Wänden N2 - Bauliche Anlagen mit Stahlkonstruktionen (bzw. auch Stahlbetonskelett- Konstruktionen) und metallenen Wänden sind bereits in sehr großer Zahl errichtet. Dazu gehören kleinere bis größere Lagerhallen ebenso wie Einkaufszentren. Sie zeichnen sich durch große Flexibilität, einfache Planung, kurze Bauzeit und rel. geringe Kosten aus. Auch in der nahen Zukunft ist deshalb mit Planung und Errichtung weiterer solcher baulicher Anlagen zu rechnen. Abhängig von der Nutzung der Hallen sind auch mehr oder weniger umfangreiche elektrische und elektronische Systeme vorhanden, die wichtige Funktionen sicherstellen müssen. Der Blitzschutz für diese baulichen Anlagen sollte sich also nicht nur im „klassischen“ Gebäude-Blitzschutz nach DIN V 0185-3 VDE V 0185 Teil 3 [1] erschöpfen; ein Ergänzung hin zu einem sinnvollen Grundschutz der elektrischen und elektronischen Systeme nach DIN V 0185-4 VDE V 0185 Teil 4 [2] ist anzuraten. Im folgenden Beitrag wird ein Konzept vorgestellt, mit dem ein hochwertiger Blitzschutz sowohl der baulichen Anlage und der darin befindlichen Personen, als auch der elektrischen und elektronischen Systeme verwirklicht werden kann. Insbesondere bei großflächigen Hallen stellen sich dabei besondere Anforderungen. Das Konzept und die zugehörigen blitzschutz-technischen Maßnahmen können drei Hauptbereichen zugeordnet werden: - Äußerer Blitzschutz; - Innerer Blitzschutz; - weitergehende besondere Maßnahmen. Das Konzept sowie die Maßnahmen werden allgemein beschrieben und teilweise anhand einer ausgeführten Anlage mit Fotos beispielhaft dokumentiert. KW - Blitzschutz KW - Stahlbetonkonstruktion KW - Lightning protection KW - reinforced concrete Y1 - 2003 ER - TY - JOUR A1 - Kern, Alexander A1 - Landers, E.-U. T1 - Die neuen Blitzschutz-Vornormen der Reihe VDE-V 0185:2002 Y1 - 2002 ER - TY - JOUR A1 - Kern, Alexander A1 - Landers, E.-U. T1 - Die künftige deutsche Blitzschutznormung (2/3) – Reihe DIN EN 62305:2006 – Teil 2: Risikomanagement JF - De : der Elektro- und Gebäudetechniker / Ausgabe ZV. 81 (2006), H. 18 - 19 Y1 - 2006 SN - 1617-1160 ER - TY - JOUR A1 - Kern, Alexander A1 - Landers, E.-U. A1 - Scheibe, K. A1 - Zahlmann, P. T1 - Die künftige deutsche Blitzschutznormung (1) : Reihe DIN EN 62305 / VDE 0185-305-x:2006 JF - De : der Elektro- und Gebäudetechniker / Ausgabe ZV. 81 (2006), H. 15-16 Y1 - 2006 SN - 1617-1160 N1 - In der Bibliothek vorhanden: 23 Z 863 (Bibliothek Eupener Str.) SP - 26 EP - 30 ER - TY - CHAP A1 - Kern, Alexander A1 - Meppelink, Jan T1 - Neue Möglichkeiten elektrischer Anschlüsse an die Bewehrung und Untersuchung der Wirkung von Blitzströmen in bewehrtem Beton N2 - Im Rahmen eines modernen Blitzschutzsystems für Stahlbeton-Bauten bietet es sich an, die Betonbewehrung zu benutzen: - Sie kann die Funktionen der Ableitungseinrichtungen und des Blitzschutz- Potentialausgleichs bei einem klassischen Gebäude-Blitzschutz übernehmen [1]; - Sie kann, ggf. bei entsprechender Ergänzung, als ein geschlossener Käfig ausgebildet werden und damit eine deutliche Reduzierung der Belastung elektrischer / elektronischer Systeme durch blitzinduzierte elektromagnetische Felder erbringen (LEMP-Schutz [2]). Die Nutzung der Bewehrung ist dabei grundsätzlich gleichermaßen bei Neubauten wie auch bei Ertüchtigungen möglich und sinnvoll. So stellt die Nutzung der Bewehrung beispielsweise im Bereich von Großkraftwerken eine wesentliche Ertüchtigungsmaßnahme für den Blitzschutz elektrischer und elektronischer Einrichtungen dar: - Einerseits wird der Blitzschutz-Potentialausgleich durch den Anschluss metallener Einrichtungen wie Elektronik-Schränke, Kabeltrag-Konstruktionen, Rohrleitungen, etc. an die Bewehrung deutlich verbessert. - Andererseits kann bei größeren Gebäuden die elektromagnetische Schirmwirkung durch die elektrische Überbrückung von vorhandenen Dehnfugen bei Stahlbetonbauten optimiert werden. Diese Dehnfugen sind teilweise nur unzureichend überbrückt, so dass bei Blitzeinschlag in das betreffende oder ein benachbartes Gebäude an Kabelstrecken, die über die Dehnfuge hinwegführen, rel. hohe Spannungen induziert werden können [2, 3]. Die sich um das gesamte Gebäude herumziehende oder zwischen zwei Gebäuden befindliche Dehnfuge muss deshalb im Abstand von maximal einigen Metern überbrückt werden. Im Falle von Blitzschutz-Ertüchtigungen in vorhandenen Gebäuden wird bisher an jeder geplanten Anschlussstelle die Bewehrung großflächig (∅ wenige 10 cm) freigelegt, dort ein elektrischer Anschluss zu dem Bewehrungsstab hergestellt, z.B. mittels eines Erdungsfestpunkts, und dann die Betonoberfläche wieder geschlossen. Je nach prognostizierter Strombelastung wird teilweise versucht, den über den Anschluss fließenden Strom bereits auf mehrere Bewehrungsstäbe zu verteilen. Dazu sind entweder die kreuzenden Stäbe zu verschweißen oder es sind direkt Anschlüsse an zwei Bewehrungsstäbe herzustellen. All dieses bedeutet einen hohen Aufwand bei der Freilegung der Bewehrung und auch wieder bei der Schließung der entstandenen Betonlöcher. Es soll deshalb hier untersucht werden, ob es beispielsweise zum Zwecke des Blitzschutz-Potentialausgleichs und auch zur Überbrückung von Dehnfugen ausreichend ist, den Anschluss an die Bewehrung nach einfachen Verfahren nur jeweils an einen Bewehrungsstab herzustellen. Damit würde der finanzielle und administrative Aufwand an Betonarbeiten deutlich reduziert. Die hier dargestellten Verfahren sind dabei insbesondere für den Einsatz bei Blitzschutz-Ertüchtigungen in bestehenden Gebäuden vorgesehen. Abschließend sollen deshalb die Möglichkeiten zur Prüfung korrekter Anschlüsse, die Grenzen der Verfahren sowie auch die Grenzen der Anwendbarkeit bei Neuanlagen diskutiert werden. KW - Blitzschutz KW - Stahlbetonkonstruktion KW - Lightning Protection KW - reinforced concrete Y1 - 2001 ER - TY - CHAP A1 - Kern, Alexander A1 - Neskakis, Apostolos A1 - Müller, Klaus-Peter T1 - Blitzschutzkonzept für eine netz-autarke Hybridanlage am Beispiel der Anlage VATALI auf Kreta N2 - Netz-autarke Anlagen bestehen üblicherweise aus einer oder mehreren Photovoltaik- (PV-) Anlagen, ggf. auch Solarthermie- (ST-) Anlagen und einem oder mehreren kleineren Windgeneratoren (sie werden deshalb auch als Hybridanlagen bezeichnet) und werden vor allem in Gegenden mit sehr schlechter öffentlicher Energieversorgung eingesetzt, d.h. insbesondere in rel. dünn bewohnten Gebieten und in Entwicklungsländern. Der Blitzschutz von netz-autarken Hybridanlagen ist ein bislang noch vergleichsweise unzureichend bearbeitetes Fachgebiet. Für große Windenergie-Anlagen (WEA) wurde in den letzten Jahren eine Zahl von FuE-Projekten durchgeführt, zum Großteil finanziert durch die öffentliche Hand, zum kleineren Teil auch durch die Industrie, d.h. die WEAHersteller. Dabei wurden bestehende Defizite im Design der WEA festgestellt und Maßnahmen vorgeschlagen, die vor den mechanischen Zerstörungen insbesondere des Rotors und vor den Störungen und Zerstörungen an den elektrischen / elektronischen Systemen der WEA weitgehend Schutz bieten [1, 2, 3]. Der Stand-der- Normung ist im Entwurf DIN VDE 0127 Teil 24 „Blitzschutz für Windenergieanlagen“ (dt. Übersetzung des internationalen Drafts IEC 61400-24 „Wind turbine generator systems; Part 24: Lightning Protection“) dokumentiert [4]. Die Maßnahmen sind allerdings insbesondere für größere WEA vorgesehen; im Falle kleinerer WEA lassen sie sich nur bedingt umsetzen. Trotzdem sind auch kleinere WEA rel. stark blitzeinschlaggefährdet, wenn sie auf einer Bergkuppe o.ä. platziert werden. Für solche kleinere WEA, wie sie bei Hybridanlagen üblicherweise Verwendung finden, müssen die Blitzschutzmaßnahmen aus der DIN VDE 0127 Teil 24 angepasst werden. Für PV- und ST-Anlagen ist eine entsprechende Blitzschutz-Norm noch nicht in Sicht. Hier ist vor allem der Schutz gegen direkte Blitzeinschläge in die Anlage bzw. die Gebäude noch nicht ausreichend beachtet. Blitzfangeinrichtungen sind oft nicht vorgesehen. In aller Regel hat man dabei bisher eine Ausführungsform des Blitzschutzes realisiert, die primär einen Ferneinschlag berücksichtigt und die dabei entstehenden induzierten, rel. energieschwachen Überspannungen durch schwächere Schutzelemente wie Rückstromdioden, Bypassdioden und zum Teil thermisch überwachte Varistoren begrenzt [5, 6, 7]. Diese Schutzelemente können allerdings bei Naheinschlägen bzw. Direkteinschlägen überlastet und damit zerstört werden. Darüber hinaus können Nahoder Direkteinschläge auch zur Schwächung der elektrischen Festigkeit der PVModulisolierung führen. Die Folge davon sind lokale extreme Wärmeentwicklungen, die sogar ein Schmelzen von Glas (sekundärer Langzeiteffekt) hervorrufen könnten. Bei einem Blitzeinschlag in die netz-autarke Hybridanlage VATALI auf Kreta im Jahre 2000 wurden sowohl einige mechanische wie auch elektrische Komponenten der Anlage zerstört bzw. zum Teil schwer beschädigt. Die Anlage VATALI besaß zum Zeitpunkt des Blitzeinschlags keinen wirksamen Blitzschutz. Der Gesamtschaden der Hardware belief sich auf ca. 60.000,- EURO. Die exponierte Stellung der Anlage auf einer Bergspitze stellte und stellt nach wie vor ein enormes Blitzeinschlag-Risiko dar, so dass auch zukünftig mit Blitzeinwirkungen gerechnet werden muss. Die Anlage wurde inspiziert, blitzschutz-technische Erfordernisse definiert und daraus Ertüchtigungsmaßnahmen abgeleitet, die mit überschaubarem Aufwand realisierbar sind. KW - Blitzschutz KW - Hybridanlage KW - Regenerative Energieanlagen KW - Lightning protection KW - renewable energy KW - hybrid system Y1 - 2001 ER - TY - JOUR A1 - Kern, Alexander A1 - Scheibe, Klaus T1 - Die neuen internationalen Blitzschutz-Standards der Reihe IEC 62305:2010 : Überblick und Stand der Umsetzung in die nationale Normenreihe DIN EN 62305 JF - 9. VDE/ABB-Blitzschutztagung : Vorträge der 9. VDE/ABB-Fachtagung vom 27. bis 28. Oktober 2011 in Neu-Ulm / Veranst.: Ausschuss für Blitzschutz und Blitzforschung (ABB) im VDE Verband der Elektrotechnik Elektronik Informationstechnik e.V. Wiss. Tagungsleitung: K. Stimper Y1 - 2011 SN - 978-3-8007-3380-4 N1 - VDE/ABB-Blitzschutztagung ; (9 ; 2011.10.27-28 ; Neu-Ulm) SP - 7 EP - 12 PB - VDE-Verl. CY - Berlin ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof T1 - Auswahl von Blitzschutzmassnahmen nach DIN EN 623305 (VDE 0185-305-x) JF - etz Elektrotechnik und Automation. 127 (2007), H. 8 Y1 - 2007 SN - 0948-7387 N1 - in der Bibliothek unter den Signaturen : 23 Z 133 und 63 ZS 035 vorhanden SP - 83 EP - 90 ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof T1 - Trennungsabstand bei Blitzschutzsystemen. Die Anforderungen nach VDE 0185-305-3:2006:10 JF - de- Der Elektro- und Gebäudetechniker (2007) Y1 - 2007 SP - 43 EP - 48 ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Die dynamische Blitzkugel : Wahrscheinlichkeitsberechnung für Blitzeinschläge in Gebäude JF - De Fachzeitschrift für das Elektrohandwerk. 13-14 (2010) Y1 - 2010 SP - 24 EP - 29 ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Detaillierte Berechnung der Einfangwirksamkeiten von Fangeinrichtungen mit einem dynamischen elektro-geometrischen Modell - Detailed calculation of the interception efficiencies for airtermination systems using a dynamic electro-geometrical model Y1 - 2011 N1 - 9. VDE/ABB-Blitzschutztagung, Neu-Ulm 2011 SP - 1 EP - 5 ER - TY - BOOK A1 - Kern, Alexander A1 - Wettingfeld, Jürgen T1 - Blitzschutzsysteme 1 : allgemeine Grundsätze, Risikomanagement, Schutz von baulichen Anlagen und Personen ; Erläuterungen zu den Normen DIN EN 62305-1 (VDE 0185-305-1):2011-10, DIN EN 62305-2 (VDE 0185-305-2):2013-02, DIN EN 62305-3 (VDE 0185-305-3):2011-10. (VDE-Schriftenreihe Normen verständlich ; 44) Y1 - 2014 SN - 978-3-8007-3511-2 PB - VDE-Verl. CY - Berlin [u.a.] ER - TY - BOOK A1 - Kern, Alexander A1 - Wettingfeld, Jürgen T1 - Blitzschutzsysteme 2 : Schutz für besondere bauliche Anlagen ; Schutz für elektrische und elektronische Systeme in baulichen Anlagen ; Erläuterungen zu den Normen DIN EN 62305-3 (VDE 0185-305-3):2011-10, DIN EN 62305-4 (VDE 0185-305-4):2011-10. (VDE-Schriftenreihe Normen verständlich ; 160) Y1 - 2015 SN - 978-3-8007-3653-9 PB - VDE-Verl. CY - Berlin [u.a.] ER - TY - JOUR A1 - Kern, Alexander A1 - Zischank, Wolfgang A1 - Beierl, Ottmar T1 - Anmerkungen zur Berechnung des Trennungsabstands nach DIN EN 62305-3 (VDE 0185-305-3): 2006-10 / Zischank, Wolfgang ; Beierl, Ottmar ; Kern, Alexander JF - 7. VDE-ABB-Blitzschutztagung : Vorträge der VDE-ABB-Fachtagung vom 15. bis 16. November 2007 in Neu-Ulm / Veranst.: Ausschuss für Blitzschutz und Blitzforschung (ABB) im VDE, Verband der Elektrotechnik, Elektronik, Informationstechnik e.V. Wiss. Tagungsltg.: K. Stimper Y1 - 2007 SN - 978-3-8007-3062-9 N1 - VDE-Fachbericht ; 64 ; Blitzschutztagung <7, 2007, Neu-Ulm> SP - 1 EP - 8 PB - VDE-Verl. CY - Berlin ER - TY - JOUR A1 - Kern, Alexander A1 - Zischank, Wolfgang J. T1 - Längsspannung an blitzstromdurchflossenen Schirmkabeln - Einfluß paralleler Entlastungsleitungen JF - Elektrie : wissenschaftlich-technische Zeitschrift der Elektrotechnik. 47 (1993), H. 6 Y1 - 1993 SN - 0013-5399 N1 - 2. ISSN: 0013-5400 ER - TY - JOUR A1 - Kirschkamp, T. A1 - Jöckel, M. A1 - Wählisch, Georg A1 - Barry, J. C. T1 - Konstruktion eines Modellauges zur Simulation von Purkinje-Spiegelbildern für die Bestimmung der Krümmungsradien und der Lage der Augenlinse JF - Biomedizinische Technik = Biomedical Engineering Y1 - 1998 SN - 1862-278X (E-Journal); 0013-5585 (Print) N1 - Printausg. in der Bibliothek vorhanden: 63 Z 471-1998/99 VL - Bd. 43 IS - H. 11 SP - 318 EP - 325 ER - TY - CHAP A1 - Knoche, K. F. A1 - Kruska, Martin A1 - Weber, P. A1 - Kuperjans, Isabel ED - Schulz, Werner F. T1 - Energiemanagement T2 - Lexikon Nachhaltiges Wirtschaften. - (Lehr- und Handbücher zur ökologischen Unternehmensführung und Umweltökonomie) Y1 - 2001 SN - 3-486-24523-6 SP - 88 EP - 92 PB - Oldenbourg CY - München [u.a.] ER - TY - CHAP A1 - Koller, R. A1 - Stellberg, Michael T1 - Schnappverbindungen T2 - Handbuch der Verbindungstechnik / hrsg. von Carl-Otto Bauer Y1 - 1991 SN - 3-446-14609-1 SP - 294 EP - 324 PB - Hanser CY - München ER - TY - JOUR A1 - Koller, R. A1 - Stellberg, Michael T1 - Hilfsmittel zum systematischen Konstruieren : Ordnen von Spannverbindungen JF - Industrie-Anzeiger. Bd. 109 (1987), H. 24 Y1 - 1987 SN - 0019-9036 SP - 28 - 29 EP - 31 - 32 ER - TY - JOUR A1 - Koller, R. A1 - Stellberg, Michael T1 - Ein Weg zu einer systematischen Konstruktion und Ordnung von Schnappverbindungen JF - Konstruktion : Zeitschrift für Produktentwicklung und Ingenieur-Werkstoffe. Bd 39 (1987), H. 8 Y1 - 1987 SN - 0720-5953 SP - 315 EP - 320 ER - TY - BOOK A1 - Kraus, Bernd A1 - Faber, Christian A1 - Hoffschmidt, Bernhard A1 - Schwarzer, Klemens T1 - Entwicklung und Optimierung der Einsatzmöglichkeiten einfacher solarer Luftkollektoren aus bestehenden Fassadenelementen im Industriehallenbau : Abschlussbericht ; Projektdauer: 1.9.2003 - 28.5.2005 / Solar-Institut Jülich (SIJ), FH Aachen, Aachen University of Applied Sciences. Projektleitung: Bernd Kraus Y1 - 2005 PB - Technische Informationsbibliothek u. Universitätsbibliothek CY - Hannover ER - TY - CHAP A1 - Krichel, Frank A1 - Kern, Alexander A1 - Krämer, Heinz-Josef A1 - Wettingfeld, Jürgen A1 - Reetz, Josef A1 - Kienlein, Manfred T1 - Blitzschutzmaßnahmen für Photovoltaik- und kleine Windenergieanlagen – Einige Beispiele T1 - Lightning Protection for photovoltaic and small wind energy power plants N2 - Ein von der Arbeitsgemeinschaft (AG) Solar NRW und diversen Industriepartnern gefördertes und an der Fachhochschule Aachen, Abt. Jülich durchgeführtes Forschungsprojekt „Blitzschutz für netz-autarke Hybridanlagen“ machte es möglich, sich mit dem Blitzschutz speziell solcher Anlagen näher zu beschäftigen. Vermehrt bekannt gewordene Schadensfälle an nicht netz-gekoppelten Hybridanlagen waren der Auslöser, den Schutz zu überdenken. Definiertes Ziel war es, für netz-autarke energietechnische Anlagen ein Konzept zum Schutz vor Blitzeinwirkungen zu erstellen. Diese Anlagen bestehen üblicherweise aus einer oder mehreren Photovoltaikanlagen, ggf. auch Solarthermieanlagen und einem oder mehreren kleineren Windgeneratoren (sie werden deshalb auch als Hybridanlagen bezeichnet). Zur Erhöhung der Versorgungssicherheit kann noch ein Dieselaggregat dazukommen. Hybridanlagen werden vor allem in Gebieten mit sehr schlechter öffentlicher Energieversorgung eingesetzt, d.h. insbesondere in relativ dünn bewohnten Gebieten und in Entwicklungsländern. Dem Blitzschutz von Hybridanlagen kommt dabei eine steigende Bedeutung zu. Besonderes Augenmerk in dem genannten Forschungsprojekt sollte dabei auf die technisch/wirtschaftliche Ausgewogenheit des Schutzes gelegt werden: • die Schutzmaßnahmen sollen nur in solchen Fällen eingesetzt werden, wo dies als Ergebnis von Risikoanalysen sinnvoll erscheint; • für typische netz-autarke Hybridanlagen sollen die Schutzmaßnahmen ohne deutliche Verteuerung realisierbar sein (es soll also kein absoluter Schutz realisiert werden; ggf. soll lediglich der auftretende Schaden soweit möglich minimiert werden). Dazu wurde in einem ersten Schritt zunächst eine Aufnahme des Iststandes einiger typischer netz-autarker Hybridanlagen und deren einzelnen Komponenten durchgeführt. Aufgrund dessen wurde eine umfassende Risikoanalyse zur Blitzbedrohung dieser Anlagen auf der Basis von VDE V 0185 Teil 2:2002-11 [1] erstellt. Die Ergebnisse mündeten in ein technisch/wirtschaftlich ausgewogenes Konzept für den Anlagen- Blitzschutz (d.h. insbesondere dem Schutz vor direkten Blitzeinschlägen und deren unmittelbaren Auswirkungen) nach VDE V 0185 Teil 3:2002-11 [2] und für den Elektronik-Blitzschutz (d.h. für den Schutz vor Überspannungen durch direkte, insbesondere aber auch indirekte Blitzeinschläge) nach VDE V 0185 Teil 4:2002-11 [3]. Aufgrund der gesammelten Ergebnisse konnten dabei allgemeine Empfehlungen für den Äußeren und Inneren Blitzschutz von regenerativen Energieerzeugungssystemen erstellt werden. Diese sollen in Schulungen einmünden, die für Hersteller und Betreiber von Hybridanlagen angeboten werden. Durch die Anwendung wird der Schutz der Anlagen vor Blitzeinwirkung und elektromagnetischen Störungen verbessert, was sich in einer reduzierten Ausfallwahrscheinlichkeit bzw. erhöhten Verfügbarkeit wiederspiegelt. An einigen ausgewählten Anlagen werden mit Hilfe der im Projekt involvierten Industriepartner die Schutzmaßnahmen realisiert. Hierbei entstanden den Eigentümern bzw. Betreibern der Anlagen keine Kosten. In diesem Beitrag werden beispielhaft drei Anlagenprojekte detailliert gezeigt. Es handelt sich dabei um eine Schweinezuchtfarm in Magallón (Spanien, Zaragozza), das bioklimatische Haus (Kreta, Heraklion) und die Tegernseer- Hütte (Deutschland, Lenggries). KW - Blitzschutz KW - Photovoltaikanlagen KW - Windenergieanlagen KW - Lightning protection KW - photovoltaic system KW - wind turbine Y1 - 2003 ER - TY - CHAP A1 - Kubalski, T. A1 - Butenweg, Christoph T1 - Ausfachungsmauerwerk unter kombinierter seismischer Beanspruchung T2 - Erdbeben und bestehende Bauten : 14. D-A-C-H Tagung 20.08. - 21.08.2015, ETH Zürich. (Dokumentation / SIA ; D 0255) Y1 - 2015 SN - 978-3-03732-060-0 SP - 117 EP - 122 PB - SGEB CY - Zürich ER - TY - JOUR A1 - Kubalski, Thomas A1 - Butenweg, Christoph T1 - Modelling strategies for horizontally loaded infill masonry T1 - Modellierungsansätze für horizontal beanspruchtes Ausfachungsmauerwerk JF - Mauerwerk : European journal of masonry Y1 - 2015 U6 - http://dx.doi.org/10.1002/dama.201500675 VL - Volume 19 IS - Issue 5 SP - 363 EP - 369 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Kubalski, Thomas A1 - Butenweg, Christoph A1 - El-Deib, Khaled ED - Jesse, Dirk T1 - Vereinfachte Berücksichtigung der Rahmentragwirkung in Mauerwerksgebäuden T1 - Simplified consideratioon of framing effects in masonry buildings JF - Bautechnik N2 - Aufgrund der gestiegenen Anforderungen durch höhere Ein-wirkungen aus Wind und Erdbeben ist eine Verbesserung und Optimierung der Berechnungs- und Bemessungsansätze für Mauerwerksbauten erforderlich. Eine bessere Ausnutzung der Tragwerksreserven ist durch die Berücksichtigung der Rah-mentragwirkung mit einer Aktivierung der Deckenscheiben in den Rechenmodellen möglich, die in der Praxis aufgrund der Komplexität der Wand-Decken-Interaktion bislang nicht aus-genutzt wird. Im vorliegenden Aufsatz wird ein vereinfachter Ansatz auf Grundlage der mitwirkenden Plattenbreite von Schubwänden aus Mauerwerk vorgestellt, der die wesentli-chen Einfl ussfaktoren in parametrisierten Tabellen erfasst. Damit steht den Tragwerksplanern ein einfach anwendbares Werkzeug zur Verfügung, um die Rahmentragwirkung in der Mauerwerksbemessung anzusetzen. N2 - Due to the increased requirements resulting from higher wind and earthquake loads, it is necessary to improve and optimise the calculation and design approaches for masonry structures. An important contribution to a better utilisation of the structural load-bearing reserves is the consideration of the framing ef-fects through the activation of the fl oor slabs in the calculation models, which has not been utilised in practice so far due to the complexity of the wall-slab interaction. The paper presents a simplifi ed approach based on the contributory slab width, which captures the essential infl uencing factors in parameter-ised tables. This provides structural engineers with a simple tool to exploit the frame load-bearing effect in masonry design. KW - Rahmentragwirkung KW - Mauerwerksgebäude KW - Wand-Decken-Interaktion KW - Momentenverteilung KW - DIN EN 1996 Y1 - 2022 U6 - http://dx.doi.org/10.1002/bate.202200081 SN - 0932-8351 SN - 1437-0999 VL - 99 IS - 12 SP - 865 EP - 928 PB - Ernst & Sohn CY - Berlin ER - TY - CHAP A1 - Kuhlmann, W. A1 - Bettzieche, V. A1 - Roesler, F. A1 - Butenweg, Christoph A1 - Könke, C. A1 - Meskouris, Konstantin T1 - Baudynamische Untersuchung von Talsperren des Ruhrverbandes T2 - Neubewertung der Erdbebensicherheit von Talsperren in Deutschland : DGEB-Workshop, 28. November 2003 in Potsdam = Assessment of the seismic safety of dams in Germany / organisiert von der Deutschen Gesellschaft für Erdbebeningenieurwesen und Baudynamik. K. Meskouris ... (Hrsg.) (DGEB-Publikation ; Nr. 12) Y1 - 2005 SN - 3-930108-08-9 SP - 37 EP - 48 PB - DGEB CY - Aachen ER - TY - JOUR A1 - Kuhlmann, Wolfram A1 - Butenweg, Christoph A1 - Bettzieche, Volker T1 - Experimentelle und numerische Untersuchungen zur baudynamischen Beurteilung von Talsperren JF - Wasserwirtschaft : Hydrologie, Wasserbau, Hydromechanik, Gewässer, Ökologie, Boden Y1 - 2006 SN - 0043-0978 (E-Journal); 0043-0978 (Print) VL - Band 96 IS - Heft 5 SP - 10 EP - 16 ER - TY - CHAP A1 - Kuhlmann, Wolfram A1 - Butenweg, Christoph A1 - Bettzieche, Volker A1 - Meskouris, Konstantin T1 - Experimentelle und numerische Untersuchungen zur baudynamischen Beurteilung von Talsperren des Ruhrverbandes T2 - 13. Deutsches Talsperrensymposium in Weimar Y1 - 2004 SP - 1 EP - 26 ER - TY - JOUR A1 - Kuhlmann, Wolfram A1 - Butenweg, Christoph A1 - Meskouris, Konstantin T1 - Baudynamische Untersuchung des Aachener Doms unter Erdbebenbelastung JF - Bautechnik : Zeitschrift für den gesamten Ingenieurbau Y1 - 2003 U6 - http://dx.doi.org/10.1002/bate.200305080 SN - 1437-0999 (E-Journal); 0005-6820 (Print); 0932-8351 (Print) N1 - Als Printausgabe in der Bibliothek Bayernallee vorhanden: 13 Z 177 VL - Vol. 80 IS - Iss. 10 SP - 675 EP - 684 ER - TY - CHAP A1 - Kuhlmann, Wolfram A1 - Butenweg, Christoph A1 - Meskouris, Konstantin A1 - Kempen, Thomas T1 - Simulation des Tragverhaltens des Aachener Doms im Erdbebenfall T2 - Die karolingische Pfalzkapelle in Aachen : Material, Bautechnik, Restaurierung. (Arbeitshefte der rheinischen Denkmalpflege ; 78) Y1 - 2012 SN - 978-3-88462-325-1 SP - 237 EP - 248 PB - Wernersche Verlags-Gesellschaft CY - Worms ER - TY - JOUR A1 - Kuperjans, Isabel T1 - Exergetische und exergoökonomische Analyse thermischer Prozesse JF - Arbeitsbericht / Institut für Wirtschaftswissenschaften, Rheinisch-Westfälische Technische Hochschule Aachen Y1 - 1996 IS - 06 ER - TY - THES A1 - Kuperjans, Isabel T1 - Verfahren zur Analyse und Bewertung industrieller Energieanlagen Y1 - 2000 N1 - Aachen, Techn. Hochsch., Diss., 2000 CY - Aachen ER - TY - JOUR A1 - Kuperjans, Isabel T1 - Gute Planung ist alles : Energieeffizienz in der Pharmaproduktion JF - Pharma + Food Y1 - 2011 SN - 1434-8942 VL - 2011 IS - 2 SP - 8 EP - 10 PB - Hüthig CY - Heidelberg ER - TY - CHAP A1 - Kuperjans, Isabel A1 - Augenstein, Eckardt T1 - „EUSEBIA – Software zur Analyse und Verbesserung der betrieblichen Energiewirtschaft T2 - Optimierung in der Energieversorgung : Tagung Veitshöchheim, 9. und 10. Oktober 2001. - (VDI-Berichte ; 1627) Y1 - 2001 SN - 3-18-091627-3 SP - 267 EP - 268 PB - VDI-Verl. CY - Düsseldorf ER -