TY - CHAP A1 - Logen, Steffen A1 - Höfken, Hans-Wilhelm A1 - Schuba, Marko T1 - Simplifying RAM Forensics : A GUI and Extensions for the Volatility Framework T2 - 2012 Seventh International Conference on Availability, Reliability and Security (ARES), 20-24 August 2012, Prague, Czech Republic N2 - The Volatility Framework is a collection of tools for the analysis of computer RAM. The framework offers a multitude of analysis options and is used by many investigators worldwide. Volatility currently comes with a command line interface only, which might be a hinderer for some investigators to use the tool. In this paper we present a GUI and extensions for the Volatility Framework, which on the one hand simplify the usage of the tool and on the other hand offer additional functionality like storage of results in a database, shortcuts for long Volatility Framework command sequences, and entirely new commands based on correlation of data stored in the database. Y1 - 2012 SN - 978-1-4673-2244-7 U6 - https://doi.org/10.1109/ARES.2012.12 SP - 620 EP - 624 PB - IEEE CY - New York ER - TY - JOUR A1 - Ferrein, Alexander A1 - Siebel, Nils T. A1 - Steinbauer, Gerald T1 - Hybrid control for autonomous systems — Integrating learning, deliberation and reactive control JF - Robotics and Autonomous Systems Y1 - 2010 U6 - https://doi.org/10.1016/j.robot.2010.06.003 SN - 0921-8890 VL - 58 IS - 9 SP - 1037 EP - 1038 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Niemüller, Tim A1 - Ferrein, Alexander A1 - Lakemeyer, Gerhard T1 - A Lua-based behavior engine for controlling the humanoid robot Nao JF - RoboCup 2009: Robot Soccer World Cup XIII Y1 - 2010 U6 - https://doi.org/10.1007/978-3-642-11876-0_21 N1 - Part of the book series: Lecture Notes in Computer Science ((LNAI,volume 5949)) N1 - 13th RoboCup International Symposium, Graz, Austria, June/July, 2009 SP - 240 EP - 251 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Orzada, Stephan A1 - Solbach, Klaus A1 - Gratz, Marcel A1 - Brunheim, Sascha A1 - Fiedler, Thomas M. A1 - Johst, Sören A1 - Bitz, Andreas A1 - Shooshtary, Samaneh A1 - Abuelhaija, Ashraf A1 - Voelker, Maximilian N. A1 - Rietsch, Stefan H. G. A1 - Kraff, Oliver A1 - Maderwald, Stefan A1 - Flöser, Martina A1 - Oehmingen, Mark A1 - Quick, Harald H. A1 - Ladd, Mark E. T1 - A 32-channel parallel transmit system add-on for 7T MRI JF - Plos one Y1 - 2019 U6 - https://doi.org/10.1371/journal.pone.0222452 ER - TY - JOUR A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Johst, Sören A1 - Gratz, Marcel A1 - Völker, Maximilian N. A1 - Kraff, Oliver A1 - Abuelhaija, Ashraf A1 - Fiedler, Thomas M. A1 - Solbach, Klaus A1 - Quick, Harald H. A1 - Ladd, Mark E. T1 - Analysis of an integrated 8-Channel Tx/Rx body array for use as a body coil in 7-Tesla MRI JF - Frontiers in Physics Y1 - 2017 U6 - https://doi.org/10.3389/fphy.2017.00017 SN - 2296-424X N1 - Article number 17 VL - 5 IS - Jun ER - TY - JOUR A1 - Scholl, Ingrid A1 - Palm, Christoph A1 - Lehmann, Thomas Martin A1 - Spitzer, Klaus T1 - Quantitative Farbmessung in laryngoskopischen Bildern. Palm, C; Scholl, I; Lehmann, TM; Spitzer, K. JF - Bildverarbeitung für die Medizin 1998. Hrsg.: Thomas Lehmann ... Y1 - 1998 SN - 3-540-63885-7 SP - 412 EP - 416 PB - Springer CY - Berlin ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus temperature limits JF - Medical Physics Y1 - 2017 U6 - https://doi.org/10.1002/mp.12034 N1 - This article is corrected by: Errata: Erratum: “RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus tissue temperature limits” [Med. Phys. 44(1), 143–157 (2017)] Volume 44, Issue 2, 772 VL - 44 IS - 1 SP - 143 EP - 157 ER - TY - JOUR A1 - Dieringer, Matthias A. A1 - Renz, Wolfgang A1 - Lindel, Tomasz Dawid A1 - Seifert, Frank A1 - Frauenrath, Tobias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Waiczies, Helmar A1 - Hoffmann, Werner A1 - Rieger, Jan A1 - Pfeiffer, Harald A1 - Ittermann, Bernd A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Design and application of a four-channel transmit/receive surface coil for functional cardiac imaging at 7T JF - Journal of Magnetic Resonance Imaging N2 - Purpose To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T. Materials and Methods A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3. Results Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach. Conclusion A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated. Y1 - 2011 U6 - https://doi.org/10.1002/jmri.22451 SN - 1522-2586 VL - 33 IS - 3 SP - 736 EP - 741 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Clemens, Markus A1 - Bitz, Andreas T1 - Safety of subjects during radiofrequency exposure in ultra-high-field magnetic resonance imaging JF - IEEE Letters on Electromagnetic Compatibility Practice and Applications N2 - Magnetic resonance imaging (MRI) is one of the most important medical imaging techniques. Since the introduction of MRI in the mid-1980s, there has been a continuous trend toward higher static magnetic fields to obtain i.a. a higher signal-to-noise ratio. The step toward ultra-high-field (UHF) MRI at 7 Tesla and higher, however, creates several challenges regarding the homogeneity of the spin excitation RF transmit field and the RF exposure of the subject. In UHF MRI systems, the wavelength of the RF field is in the range of the diameter of the human body, which can result in inhomogeneous spin excitation and local SAR hotspots. To optimize the homogeneity in a region of interest, UHF MRI systems use parallel transmit systems with multiple transmit antennas and time-dependent modulation of the RF signal in the individual transmit channels. Furthermore, SAR increases with increasing field strength, while the SAR limits remain unchanged. Two different approaches to generate the RF transmit field in UHF systems using antenna arrays close and remote to the body are investigated in this letter. Achievable imaging performance is evaluated compared to typical clinical RF transmit systems at lower field strength. The evaluation has been performed under consideration of RF exposure based on local SAR and tissue temperature. Furthermore, results for thermal dose as an alternative RF exposure metric are presented. Y1 - 2020 SN - 2637-6423 U6 - https://doi.org/10.1109/LEMCPA.2020.3029747 VL - 2 IS - 3 SP - 1 EP - 8 PB - IEEE CY - New York, NY ER - TY - BOOK A1 - Scholl, Ingrid ED - Lehmann, Thomas Martin ED - Spitzer, Klaus T1 - Bildverarbeitung für die Medizin : Algorithmen - Systeme - Anwendungen ; proceedings des Aachener Workshops am 8. und 9. November 1996 / Institut für Medizinische Informatik und Biometrie der RWTH Aachen. Hrsg. von Thomas Lehmann ; Ingrid Scholl ; Klaus Spitzer Y1 - 1996 SN - 3-86073-519-5 PB - Verlag der Augustinus-Buchhandlung CY - Aachen ER - TY - CHAP A1 - Scholl, Ingrid A1 - Bartella, Alexander K. A1 - Moluluo, Cem A1 - Ertural, Berat A1 - Laing, Frederic A1 - Suder, Sebastian T1 - MedicVR : Acceleration and Enhancement Techniques for Direct Volume Rendering in Virtual Reality T2 - Bildverarbeitung für die Medizin 2019 : Algorithmen – Systeme – Anwendungen Y1 - 2019 SN - 978-3-658-25326-4 U6 - https://doi.org/10.1007/978-3-658-25326-4_32 SP - 152 EP - 157 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Scholl, Ingrid A1 - Schubert, Nicole A1 - Ziener, Pascal A1 - Pietrzyk, Uwe T1 - GPU-basiertes Volumenrendering von multimodalen medizinischen Bilddaten in Echtzeit JF - Bildverarbeitung für die Medizin 2010 N2 - Die vorliegende Arbeit zeichnet sich dadurch aus, dass registrierte unsegmentierte Volumina aus multimodalen Bilddatensätzen (z.B. MRT, PET) gleichzeitig in einer 3D-Rekonstruktion visualisiert werden und in Echtzeit manipuliert werden können. Ermöglicht wird die Echtzeitfähigkeit durch die Programmierung der Algorithmen zur direkten Volumenvisualisierung auf der Grafikkarte mittels der neuen CUDA-Technologie. Die Zuordnung der Farbeigenschaften wird über 1D-Transferfunktionen für jedes Volumen getrennt gesteuert. So können durch die interaktive Veränderung der 1D-Transferfunktion Detailinformationen aus den zwei Bilddatensätzen getrennt kontrolliert werden und die Vorteile der verschiedenen Bildmodalitäten in einer Visualisierung genutzt werden. Mittels dieses interaktiven Frameworks können neue Erkenntnisse insbesondere über neurodegenerativen Erkrankungen gewonnen werden. Y1 - 2010 SN - 978-3-642-11967-5 N1 - Bildverarbeitung für die Medizin 2010 - Algorithmen - Systeme - Anwendungen, Aachen, Germany, March 14-16, 2010 SP - 400 EP - 404 PB - Springer CY - Berlin ER - TY - JOUR A1 - Schmitt, Robert A1 - Scholl, Ingrid A1 - Cai, Yu A1 - Xia, Ji A1 - Dziwoki, Paul A1 - Harding, Martin A1 - Pavim, Alberto T1 - Machine vision system for inline inspection in carbide insert production JF - Proceedings of the 36th International MATADOR Conference N2 - In steps of the production chain of carbide inserts, such as unloading or packaging, the conformity test of the insert type is done manually, which causes a statistic increase of errors due to monotony and fatigue of the worker and the wide variety of the insert types. A machine vision system is introduced that captures digital frames of the inserts in the production line, analyses inspects automatically and measures four quality features: coating colour, edge radius, plate shape and chip-former geometry. This new method has been tested on several inserts of different types and has shown that the prevalent insert types can be inspected and robustly classified in real production environment and therefore improves the manufacturing automation. Y1 - 2010 SN - 978-1-84996-431-9 U6 - https://doi.org/10.1007/978-1-84996-432-6_77 N1 - 36th MATADOR Conference, University of Manchester, July 2010 SP - 339 EP - 342 PB - Springer CY - Berlin ER - TY - JOUR A1 - Schlamann, M. A1 - Yoon, M.-S. A1 - Maderwald, S. A1 - Pietrzyk, Thomas A1 - Bitz, Andreas A1 - Gerwig, M. A1 - Forsting, M. A1 - Ladd, S. C. A1 - Ladd, M. E. A1 - Kastrup, O. T1 - Auswirkungen der Magnetresonanztomografie auf die Elektrophysiologie des motorischen Kortex: eine Studie mit transkranieller Magnetstimulation T1 - Effects of MRI on the electrophysiology of the motor cortex: a TMS study JF - RöFo - Fortschritte auf dem Giebiet der Röntgenstrahlen und der bildgebenden Verfahren Y1 - 2009 U6 - https://doi.org/10.1055/s-0028-1109038 SN - 1438-9029 VL - 181 IS - 3 SP - 215 EP - 219 PB - Thieme CY - Stuttgart ER -