TY - JOUR A1 - Martin, Conrad A1 - Frauenrath, Tobias A1 - Özerdem, Celal A1 - Renz, Wolfgang A1 - Niendorf, Thoralf T1 - Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging JF - European Radiology N2 - Objective The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments. Methods MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR. Results The consistency with which individual reed sensors would activate at the same field strength was found to be 100% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated. Conclusions MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur. KW - MRI KW - MR safety KW - Magneto alert sensor KW - High field MRI KW - Uktrahigh field MRI Y1 - 2011 U6 - https://doi.org/10.1007/s00330-011-2153-z SN - 1432-1084 VL - 21 SP - 2187 EP - 2192 PB - Springer CY - Berlin, Heidelberg ER - TY - PAT A1 - Bragard, Michael A1 - Hüning, Felix A1 - Kowalewski, Paul T1 - Vorrichtung zur Relativlagenbestimmung [Offenlegungschrift] N2 - Die Erfindung betrifft eine Vorrichtung zur Bestimmung einer Relativlage zwischen einem feststehenden Teil und einem zu demselben in eine Bewegungsrichtung bewegbaren beweglichen Teil, wobei der feststehende Teil mit einem Wiegandsensor versehen ist, wobei der Wiegandsensor zwischen zwei gegenpolig zueinander ausgebildeten Permanentmagneten angeordnet ist und dass der bewegliche Teil eine Mehrzahl von beabstandet zueinander angeordneten Magnetisierungsstegen aus einem magnetisch leitenden Material aufweist, die in der Bewegungsrichtung zumindest eine gleich große Erstreckung aufweisen wie der Permanentmagnet, dass ein Abstand zwischen benachbarten Magnetisierungsstegen derart gewählt ist, dass in einer ersten Relativlage ein erster Permanentmagnet von einem der Magnetisierungsstege überdeckt ist und ein zweiter Permanentmagnet nicht von einem der Magnetisierungsstege überdeckt ist. Y1 - 2023 N1 - Offenlegungschrift zu DE102022115350A1 2023.12.21 ER - TY - CHAP A1 - Penne, Jochen A1 - Profittlich, Martin A1 - Ringbeck, Thorsten A1 - Buxbaum, Bernd ED - D, Nicola D'Apuzzo T1 - Touchless detailed 3D scan of human hand anatomy using time-of-flight cameras T2 - Proceedings of the International Conference on 3D Body Scanning Technologies : Lugano, Switzerland, 19-20 October 2010 Y1 - 2010 SN - 978-3-033-02714-5 SP - 361 EP - 369 PB - Hometrica Consulting CY - Zürich ER - TY - RPRT A1 - Leßenich, Nina A1 - Ritz, Thomas A1 - Wallenborn, Ramona T1 - Prototyping zur Verbesserung der Benutzerfreundlichkeit mobiler Software : Potenziale benutzerfreundlicher Software-Entwicklung ; Info-Broschüre N2 - Mobile Anwendungen nehmen mit der Verbreitung von Smartphones zu. Die Akzeptanz der Nutzer bestimmt den Erfolg solcher mobiler Applikationen dabei maßgeblich. Um diese Anerkennung zu schaffen, ist eine möglichst hohe Gebrauchstauglichkeit, auch Usability genannt, notwendig. Die Informationsbroschüre „Prototyping zur Verbesserung der Benutzerfreundlichkeit mobiler Software“ richtet sich an Personen, die an der Gestaltung und entwicklung von (mobiler) Software beteiligt sind. In dieser Broschüre werden mögliche Potenziale im Bereich einer effizienten und benutzerzentrierten Software-Entwicklung aufgezeigt. Y1 - 2014 PB - eBusiness-Lotse CY - Aachen ER - TY - PAT A1 - Hilgenstock, Jörg A1 - Lange, Robert A1 - Riedel, Helmut A1 - Ringbeck, Thorsten T1 - Verfahren und Entfernungsmessvorrichtung zum Bestimmen der Entfernung zwischen einem Objekt und der Vorrichtung : [Offenlegungsschrift / Europäische Patentanmeldung] T1 - Method and distance measuring device for determining the distance between an object and the device Y1 - 2006 PB - Deutsches Patent- und Markenamt / Europäisches Patentamt CY - München / Den Hague ER - TY - JOUR A1 - Ritz, Thomas A1 - Pisarczyk, Rafael A1 - Sachtleben, Johanna A1 - Leßenich, Nina T1 - Usability Engineering maßgeschneidert : Modellbaukasten zur Entwicklung gebrauchstauglicher mobiler Software JF - Wissenschaft trifft Praxis Y1 - 2014 SN - 2198-8544 (Print) SN - 2198-9362 (Online) N1 - Der Link führt zum vollständigen Heft, der Artikel beginnt auf S.79. VL - 1 IS - 1 SP - 79 EP - 88 PB - Begleitforschung Mittelstand-Digital c/o WIK-Consult GmbH CY - Bad Honnef ER - TY - JOUR A1 - Wallenborn, Ramona A1 - Ritz, Thomas T1 - Mobilität miteinander teilen : städtisches eCarsharing in einer vernetzten Gesellschaft ; [vernetztes Fahren von morgen] JF - Neue Mobilität : das Magazin vom Bundesverband eMobilität Y1 - 2014 SN - 2191-5636 VL - 5 IS - 14 (Herbstausg.) SP - 92 EP - 95 PB - Bundesverband eMobilität BEM CY - Berlin ER - TY - RPRT A1 - Rahier, Michael A1 - Ritz, Thomas A1 - Wallenborn, Ramona T1 - Elektromobilität in einer vernetzten Welt : Potenziale für die IT-Branche bei der Organisation der Mobilität von morgen ; Info-Broschüre N2 - Die Informationsbroschüre „Elektromobilität in einer vernetzten Welt“ richtet sich an IT-Dienstleister. In dieser Broschüre werden mögliche Potenziale im Bereich der Elektromobilität aufgezeigt. Die Mobilität der Zukunft ist eine interdisziplinäre Angelegenheit und kein reines Automotive-Thema mehr. Beispiele wie Mobilitätsmanagement, eCommerce und Individualisierung sind im Mobilitätsbereich für die IT-Branche relevant. Y1 - 2014 PB - eBusiness-Lotse CY - Aachen ER - TY - CHAP A1 - Schwarte, Rudolf A1 - Buxbaum, Bernd A1 - Heinol, Horst-Guenther A1 - Xu, Zhanping A1 - Ringbeck, Thorsten A1 - Zang, Zhigang T1 - Novel 3D-vision systems based on layout optimized PMD-structures T2 - Proceedings / OPTO 98, Internationaler Kongress und Fachausstellung für Optische Sensorik, Messtechnik und Elektronik, 18. - 20. Mai 1998, Kongreßzentrum Erfurt Y1 - 1998 N1 - Internationaler Kongress und Fachausstellung für Optische Sensorik, Messtechnik & Elektronik <3, 1998, Erfurt> ; International Congress and Exhibition on Optoelectronics, Optical Sensors and Measuring Techniques <3, 1998, Erfurt> ; OPTO <3, 1998, Erfurt> SP - 197 EP - 202 PB - ACS Organisations GmbH CY - Wunsdorf ER - TY - JOUR A1 - Dieringer, Matthias A. A1 - Renz, Wolfgang A1 - Lindel, Tomasz D. A1 - Seifert, Frank A1 - Frauenrath, Tobias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Waiczies, Helmar A1 - Hoffmann, Werner A1 - Rieger, Jan A1 - Pfeiffer, Harald A1 - Ittermann, Bernd A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Design and application of a four-channel transmit/receive surface coil for functional cardiac imaging at 7T JF - Journal of Magnetic Resonance Imaging N2 - Purpose To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T. Materials and Methods A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3. Results Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach. Conclusion A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated. Y1 - 2011 U6 - https://doi.org/10.1002/jmri.22451 SN - 1522-2586 VL - 33 IS - 3 SP - 736 EP - 741 PB - Wiley-Liss CY - New York ER -