TY - CHAP A1 - Groß, Rolf Fritz A1 - Thulfaut, Christian A1 - Renz, Ulrich ED - Jamal, Rahman ED - Jaschinski, Hans T1 - On-Line Simulation mit LabView: Experimentelle und numerische Analyse homogener Gasphasenreaktionen aus Kraftwerksprozessen, T2 - Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000 N2 - The institute of heat transfer and air conditioning at the Aachen University of Technology operates several test facilities in order to investigate homogeneous and catalytical processes for the reduction of gaseous pollutants (e.g. nitrous oxide) of flue gases in a tempeature range up to 900°C. One test facility consists of a stainless steel reactor in which the influence of reducing additives can be investigated. The software tool, created with LabVIEW 5.01, offers the possibility to measure, visualize and control all relevant physical quantities and to gain a numerical solution of the problem by solving the one dimensional, steady state conservation equations. N2 - Die bei Kohlekraftwerksprozessen entstehenden Rauchgase enthalten einen nicht unerheblichen Teil an Schadgaskomponenten (z.B. Stickoxide), die aus dem Gasstrom entfernt werden müssen. Im Rahmen von Forschungsvorhaben des BMBF und verschiedener Industriepartner betreibt der Lehrstuhl für Wärmeübertragung und Klimatechnik der RWTH Aachen Pilotanlagen und Prüfstände für Untersuchungen auf dem Gebiet der homogenen und heterogen-katalytischen Schadstoffreduktion heißer Rauchgase bei Temperaturen bis zu 900 °C. Für die Erforschung der Minderungspotentiale geeigneter, auf Distickstoffoxid reduzierend wirkender Additive, wie Wasserstoffperoxid, oder auch Katalysatoren, befindet sich ein Reaktor in Betrieb, der eine Untersuchung der Reaktionskinetik bei der Entfernung von Schadgaskomponenten aus einem lnertgasstrom ermöglicht. Wesentlich für den Erfolg der Forschungsarbeit ist eine auf das spezielle Projekt genau abgestimmte Meß- und Regelungstechnik. Neben der Auswahl geeigneter Hardwarekomponenten ist auch die Softwareentwicklung unter einer leistungsstarken und zuverlässigen Programmierumgebung von großer Bedeutung. Hierbei dient die unter LabVIEW 5.01 entwickelte Datenerfassung- und Auswertesoftware zum einen der Messung, Visualisierung und Regelung der relevanten Temperaturen, Drücke, Konzentrationen und Volumenströme einzelner Gaskomponenten. Zum anderen ermöglicht sie parallel eine numerische Simulation der Vorgänge innerhalb des Reaktors zur Anpassung reaktionskinetischer Parameter aus den sich ergebenden Versuchsdaten durch Lösung eindimensionaler, stationärer Erhaltungsgleichungen. Y1 - 2000 SN - 3-7785-2789-4 (print) SP - 103 EP - 108 PB - Hüthig CY - Heidelberg ER - TY - CHAP A1 - Groß, Rolf Fritz A1 - Müller, D. A1 - Herting, D. A1 - Schneemann, A. A1 - Renz, Ulrich ED - Rahman, Jamal ED - Jaschinski, Hans T1 - Modulare Messdatenerfassung in Forschung und Lehre T2 - Virtuelle Instrumente in der Praxis : Begleitband zum Kongress VIP '97 N2 - The Lehrstuhl für Wärmeübertragung und Klimatechnik at the Aachen University of Technology operates several test facilities to investigate fundamentals of heat and mass transfer supported by the Deutsche Forschungsgemeinschaft, the Minister für Forschung und Technologie and the industry. In order to get high-resolution and reproselection of hardware components is as critical as the design of software routines to perform successful and accurate measurements. In the following the development of the measurement and control system for three different test facilities is presented and discussed. Special attention is given to the education of students within the framework of laboratories and scientific experiments. Y1 - 1997 SN - 978-3-7785-2667-5 Pp. SP - 282 EP - 288 PB - Hüthig CY - Heidelberg ER - TY - CHAP A1 - Groß, Rolf Fritz A1 - Hecken, M. A1 - Renz, Ulrich ED - Dittler, A. ED - Hemmer, G. ED - Kasper, G. T1 - Hot gas filtration with ceramic filter candles: experimental and numerical investigations on fluid flow during element cleaning T2 - High temperature gas cleaning. Vol. 2 N2 - Ceramic hot gas filters are widely used in combined cycles based on pressurised fluidised beds. They fulfil most of the demands with respect to cleaning efficiency and long time durability, but their operation regarding the consumption of pulse gas and energy still has to be optimised. Experimental investigations were carried out to measure the flow field, the pressure and the gas temperature inside the filter candle during pulse jet cleaning. These results are compared with the results of a numerical procedure based on a solution of the two - dimensional conservation equations for momentum and energy. The observed difficulties handling different flow regimes like highly turbulent flow as well as Darcy flow simultaneously are discussed. KW - 20 fossil-fueled power plants KW - hot gas cleanup KW - ceramics KW - filtration KW - gas flow Y1 - 1999 SN - 3-9805220-1-6 N1 - 4th International Symposium and Exhibition on Gas Cleaning at High Temperatures, 22.-24.09.1999, Karlsruhe SP - 862 EP - 873 PB - KIT Institut für Mechanische Verfahrenstechnik und Mechanik CY - Karlsruhe ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Berger, J. A1 - Groß, H. T1 - Gebäudeautomation - Betriebsdatenerfassung und Gebäudeleittechnik im Klartext T1 - Operating data- and facility management in clear JF - HLH. Heizung, Lüftung/Klima, Haustechnik KW - Heizung KW - Lüftung KW - Klimatechnik KW - Lüftungstechnik KW - Haustechnik Y1 - 2003 SN - 1436-5103 VL - 54 IS - 2 SP - 81 PB - Springer CY - Düsseldorf ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Berger, J. T1 - Quo Vadis - Ausblick in die Gebäudeleittechnik der Zukunft T1 - Whitherfacility management? An outlook to the future JF - HLH. Heizung, Lüftung/Klima, Haustechnik N2 - Auf dem Weg zum vernetzten Haus stoßen Hersteller und Planer, insbesondere im privaten Wohnungsbau, zur Zeit noch auf erhebliche Widerstände bei der Durchdringung des Marktes. N2 - Producers and planners of facility management systems are still faced with building owners' reluctance, especially when it comes to private homes. Y1 - 2005 SN - 1436-5103 VL - 56 IS - 1 SP - 39 EP - 41 PB - Springer CY - Düsseldorf ER - TY - THES A1 - Groß, Rolf Fritz T1 - Zur Kinetik homogener Gasphasenreaktionen nitroser Komponenten in Rauchgasen einer kohlebefeuerten Wirbelschicht KW - Kohlefeuerung KW - Wirbelschichtfeuerung KW - Stickstoffoxide KW - Reduktion KW - Rohrreaktor Y1 - 2002 SN - 3-8322-0004-5 (softcover) SN - 3-8322-0004-6 (elektronisch) N1 - Dissertation RWTH Aachen PB - Shaker CY - Aachen ER - TY - CHAP A1 - Groß, Rolf Fritz T1 - Möglichkeiten und Grenzen für Forschung an Fachhochschulen T2 - Smart Building Convention und BIMconvention in Aachen im September Y1 - 2018 N1 - 10. und 11. September 2018, Aachen ER - TY - JOUR A1 - Gorzalka, Philip A1 - Schmiedt, Jacob Estevam A1 - Schorn, Christian T1 - Automated Generation of an Energy Simulation Model for an Existing Building from UAV Imagery JF - Buildings N2 - An approach to automatically generate a dynamic energy simulation model in Modelica for a single existing building is presented. It aims at collecting data about the status quo in the preparation of energy retrofits with low effort and costs. The proposed method starts from a polygon model of the outer building envelope obtained from photogrammetrically generated point clouds. The open-source tools TEASER and AixLib are used for data enrichment and model generation. A case study was conducted on a single-family house. The resulting model can accurately reproduce the internal air temperatures during synthetical heating up and cooling down. Modelled and measured whole building heat transfer coefficients (HTC) agree within a 12% range. A sensitivity analysis emphasises the importance of accurate window characterisations and justifies the use of a very simplified interior geometry. Uncertainties arising from the use of archetype U-values are estimated by comparing different typologies, with best- and worst-case estimates showing differences in pre-retrofit heat demand of about ±20% to the average; however, as the assumptions made are permitted by some national standards, the method is already close to practical applicability and opens up a path to quickly estimate possible financial and energy savings after refurbishment. KW - Modelica KW - heat transfer coefficient KW - heat demand KW - building energy modelling KW - building energy simulation Y1 - 2021 U6 - http://dx.doi.org/10.3390/buildings11090380 SN - 2075-5309 N1 - This article belongs to the Special Issue "Application of Computer Technology in Buildings" VL - 11 IS - 9 PB - MDPI CY - Basel ER - TY - CHAP A1 - Gorzalka, Philip A1 - Dahlke, Dennis A1 - Göttsche, Joachim A1 - Israel, Martin A1 - Patel, Dhruvkumar A1 - Prahl, Christoph A1 - Schmiedt, Jacob Estevam A1 - Frommholz, Dirk A1 - Hoffschmidt, Bernhard A1 - Linkiewicz, Magdalena T1 - Building Tomograph–From Remote Sensing Data of Existing Buildings to Building Energy Simulation Input T2 - EBC, Annex 71, Fifth expert meeting, October 17-19, 2018, Innsbruck, Austria Y1 - 2018 ER - TY - CHAP A1 - Gonsior, Daniel A1 - Hoffschmidt, Bernhard T1 - Innovative Rußfilter für LKW-Dieselmotoren (Innotrap) T2 - Feinstaubforschung in Nordrhein-Westfalen. LANUV-Fachbericht. 9 Y1 - 2008 SN - 1864-3930 SP - 13 EP - 14 PB - Landesamt für Natur, Umwelt und Verbraucherschutz Nordrhein-Westfalen CY - Recklinghausen ER -