TY - CHAP A1 - Pomp, Stefan A1 - Schwarzbözl, Peter A1 - Koll, Gerrit A1 - Hennecke, Klaus A1 - Schmitz, Mark A1 - Hoffschmidt, Bernhard T1 - Advanced concept for a solar thermal power plant with open volumetric air receiver T2 - SolarPACES 2010 : the CSP Conference: electricity, fuels and clean water from concentrated solar energy ; 21 to 24 September 2010, Perpignan, France Y1 - 2010 SP - 97 EP - 98 PB - Soc. OSC CY - Saint Maur ER - TY - JOUR A1 - Reisgen, Uwe A1 - Schleser, Markus A1 - Abdurakhmanov, Aydemir A1 - Turichin, Gleb A1 - Valdaitseva, Elena A1 - Bach, Friedrich-Wilhelm A1 - Hassel, Thomas A1 - Beniyashi, Alexander T1 - Investigation of factors influencing the formation of weld defects in non-vacuum electron beam welding JF - The Paton welding journal N2 - The influence of welding condition parameters and properties of material on formation of defects, such as humping and undercuts, in non-vacuum electron beam welding was investigated. The influence of separate welding parameters on the quality of welds was determined. Y1 - 2012 SN - 0957-798X VL - 2012 IS - 2 SP - 11 EP - 18 PB - Paton Publishing House CY - Kiev ER - TY - CHAP A1 - Achenbach, Timm A1 - Bosch, Timo A1 - Breitbach, Gerd A1 - Sauerborn, Markus T1 - Simulation zur Absorption und Wärmeübertragung an Solarturmabsorbern T2 - 77. Jahrestagung der DPG und DPG-Frühjahrstagung : 4.-8.3.2013 Y1 - 2013 SP - 1 EP - 14 ER - TY - RPRT A1 - Hoffschmidt, Bernhard T1 - HelioScan : Machbarkeitsstudie zur Entwicklung einer radargestützten Positionsregelung von Heliostatenfeldern für Solarturmkraftwerke : Schlussbericht : Laufzeit: 01.07.2010 - 31.12.2012 : Förderkennzeichen 325234A Y1 - 2013 PB - Bundesministerium für Umwelt, Naturschutz und Reaktorsicherheit CY - Berlin ER - TY - JOUR A1 - Vieira da Silva, Maria Eugenia A1 - Schwarzer, Klemens A1 - Hoffschmidt, Bernhard A1 - Pinheiro Rodrigues, Frederico A1 - Schwarzer, Tarik A1 - Costa Rocha, Paulo Alexandre T1 - Mass transfer correlation for evaporation–condensation thermal process in the range of 70 °C–95 °C JF - Renewable energy Y1 - 2013 SN - 1879-0682 (E-Journal); 0960-1481 (Print) VL - Vol. 53 SP - 174 EP - 179 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Hoffschmidt, Bernhard A1 - Alexopoulos, Spiros T1 - Perspektiven für Solarthermische Kraftwerke im Sonnengürtel T2 - Energiewende : Aspekte, Optionen, Herausforderungen : Vorträge auf der DPG-Frühjahrstagung Arbeitskreis Energie in der Deutschen Physikalischen Gesellschaft Berlin, 26. bis 28. März 2012 / hrsg. von Hardo Bruhns Y1 - 2012 SP - 81 EP - 93 PB - DPG CY - Baf Honnef ER - TY - JOUR A1 - Hagenkamp, Markus A1 - Blanke, Tobias A1 - Döring, Bernd T1 - Thermoelectric building temperature control: a potential assessment JF - International Journal of Energy and Environmental Engineering N2 - This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants. Y1 - 2021 U6 - https://doi.org/10.1007/s40095-021-00424-x N1 - Corresponding author: Markus Hagenkamp VL - 13 SP - 241 EP - 254 PB - Springer CY - Berlin ER - TY - CHAP A1 - Fricke, Barbara A1 - Ziolko, C. A1 - Anthrakidis, Anette A1 - Alexopoulos, Spiros A1 - Hoffschmidt, Bernhard A1 - Giese, F. A1 - Dillig, M. T1 - InnoSol - environmental aspects of the open volumetric receiver technology T2 - 30th ISES Biennial Solar World Congress 2011 : : Kassel, Germany, 28 August - 2 September 2011. Vol. 5 Y1 - 2012 SP - 3895 EP - 3900 PB - Curran CY - Red Hook, NY ER - TY - CHAP A1 - Ziolko, Christoph A1 - Fricke, Barbara A1 - Anthrakidis, Anette A1 - Hoffschmidt, Bernhard A1 - Dillig, Marius A1 - Giese, Frank A1 - Schwarzbözl, Peter T1 - Ökobilanzielle Aspekte technologischer Entwicklungen des Solarturmkraftwerks T2 - Forschung und Entwicklung für solarthermische Kraftwerke : 14. Kölner Sonnenkolloquium Mittwoch, 13. Juli 2011, im Auditorium des Campus Jülich der FH Aachen : Kurzfassungen der Vorträge und Poster Y1 - 2011 SP - 2 S. PB - DLR CY - Köln ER - TY - JOUR A1 - Wolisz, Henryk A1 - Schütz, Thomas A1 - Blanke, Tobias A1 - Hagenkamp, Markus A1 - Kohrn, Markus A1 - Wesseling, Mark A1 - Müller, Dirk T1 - Cost optimal sizing of smart buildings' energy system components considering changing end-consumer electricity markets JF - Energy Y1 - 2017 U6 - https://doi.org/10.1016/j.energy.2017.06.025 VL - 137 SP - 715 EP - 728 PB - Elsevier CY - Amsterdam ER -