TY - JOUR A1 - Schwager, Christian A1 - Flesch, Robert A1 - Schwarzbözl, Peter A1 - Herrmann, Ulf A1 - Teixeira Boura, Cristiano José T1 - Advanced two phase flow model for transient molten salt receiver system simulation JF - Solar Energy N2 - In order to realistically predict and optimize the actual performance of a concentrating solar power (CSP) plant sophisticated simulation models and methods are required. This paper presents a detailed dynamic simulation model for a Molten Salt Solar Tower (MST) system, which is capable of simulating transient operation including detailed startup and shutdown procedures including drainage and refill. For appropriate representation of the transient behavior of the receiver as well as replication of local bulk and surface temperatures a discretized receiver model based on a novel homogeneous two-phase (2P) flow modelling approach is implemented in Modelica Dymola®. This allows for reasonable representation of the very different hydraulic and thermal properties of molten salt versus air as well as the transition between both. This dynamic 2P receiver model is embedded in a comprehensive one-dimensional model of a commercial scale MST system and coupled with a transient receiver flux density distribution from raytracing based heliostat field simulation. This enables for detailed process prediction with reasonable computational effort, while providing data such as local salt film and wall temperatures, realistic control behavior as well as net performance of the overall system. Besides a model description, this paper presents some results of a validation as well as the simulation of a complete startup procedure. Finally, a study on numerical simulation performance and grid dependencies is presented and discussed. KW - Molten salt solar tower KW - Molten salt receiver system KW - Dynamic simulation KW - Two-phase modelling KW - Transient flux distribution Y1 - 2022 U6 - https://doi.org/10.1016/j.solener.2021.12.065 SN - 0038-092X (print) SN - 1471-1257 (online) VL - 232 SP - 362 EP - 375 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Sattler, Johannes Christoph A1 - Chico Caminos, Ricardo Alexander A1 - Atti, Vikrama Nagababu A1 - Ürlings, Nicolas A1 - Dutta, Siddharth A1 - Ruiz, Victor A1 - Kalogirou, Soteris A1 - Ktistis, Panayiotis A1 - Agathokleous, Rafaela A1 - Alexopoulos, Spiros A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Dynamic simulation tool for a performance evaluation and sensitivity study of a parabolic trough collector system with concrete thermal energy storage T2 - AIP Conference Proceedings 2303 Y1 - 2020 U6 - https://doi.org/10.1063/5.0029277 SN - 0094-243X N1 - SOLARPACES 2019: International Conference on Concentrating Solar Power and Chemical Energy Systems, 1–4 October 2019, Daegu, South Korea SP - 160004 PB - American Institute of Physics CY - Melville, NY ER - TY - JOUR A1 - Blanke, Tobias A1 - Reger, Vitali A1 - Döring, Bernd A1 - Göttsche, Joachim A1 - Kuhnhenne, Markus T1 - Koaxiale Stahlenergiepfähle JF - Stahlbau N2 - Ein entscheidender Teil der Energiewende ist die Wärmewende im Gebäudesektor. Ein Schlüsselelement sind hier Wärmepumpen. Diese benötigen eine Wärmequelle, der sie Energie entziehen können, um sie auf ein höheres Temperaturniveau zu transformieren. Diese Wärmequelle kann bspw. das Erdreich sein, dessen Wärme durch Erdsonden erschlossen werden kann. In diesem Beitrag werden in Stahlpfähle integrierte Koaxialsonden mit dem Stand der Technik von Erdsonden gleichen Durchmessers bezüglich ihrer thermischen Leistungsmerkmale verglichen. Die Stahlenergiepfähle bieten neben der Wärmegewinnung weitere Vorteile, da sie auch eine statische Funktion übernehmen und rückstandsfrei zurückgebaut werden können. Es werden analytische und numerische Berechnungen vorgestellt, um die thermischen Potenziale beider Systeme zu vergleichen. Außerdem wird ein Testaufbau gezeigt, bei dem Stahlenergiepfähle in zwei verschiedenen Längen mit vorhandenen gängigen Erdsonden verglichen werden können. Die Berechnungen zeigen einen deutlichen thermischen Mehrertrag zwischen 26 % und 148 % der Stahlenergiepfähle gegenüber dem Stand der Technik abhängig vom Erdreich. Die Messergebnisse zeigen einen thermischen Mehrertrag von über 100 %. Es lässt sich also signifikante Erdsondenlänge einsparen. Dabei ist zu beachten, dass sich damit der thermisch genutzte Bereich des Erdreichs reduziert, wodurch die thermische Regeneration und/oder das Langzeitverhalten des Erdreichs an Bedeutung gewinnt. Y1 - 2021 VL - 90. 2021 IS - 6 SP - 417 EP - 424 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Schossig, Peter A1 - Dötsch, Christian A1 - Drück, Harald A1 - Göttsche, Joachim A1 - Huenges, Ernst A1 - Kabus, Frank A1 - Tamme, Rainer T1 - Wärmespeicher für die Hausenergieversorgung JF - Wärme und Kälte - Energie aus Sonne und Erde : Jahrestagung des Forschungsverbunds Sonnenenergie in Kooperation mit der Landesinitiative Zukunftsenergie NRW / Stadermann, Gerd, Hrsg. Y1 - 2005 UR - http://publica.fraunhofer.de/documents/N-54108.html SP - 120 EP - 125 PB - Forschungsverbund Sonnenenergie CY - Berlin ER - TY - CHAP A1 - Frantz, Cathy A1 - Binder, Matthias A1 - Busch, Konrad A1 - Ebert, Miriam A1 - Heinrich, Andreas A1 - Kaczmarkiewicz, Nadine A1 - Schlögl-Knothe, Bärbel A1 - Kunze, Tobias A1 - Schuhbauer, Christian A1 - Stetka, Markus A1 - Schwager, Christian A1 - Spiegel, Michael A1 - Teixeira Boura, Cristiano José A1 - Bauer, Thomas A1 - Bonk, Alexander A1 - Eisen, Stefan A1 - Funck, Bernhard T1 - Basic Engineering of a High Performance Molten Salt Tower Receiver System T2 - AIP Conference Proceedings N2 - The production of dispatchable renewable energy will be one of the most important key factors of the future energy supply. Concentrated solar power (CSP) plants operated with molten salt as heat transfer and storage media are one opportunity to meet this challenge. Due to the high concentration factor of the solar tower technology the maximum process temperature can be further increased which ultimately decreases the levelized costs of electricity of the technology (LCOE). The development of an improved tubular molten salt receiver for the next generation of molten salt solar tower plants is the aim of this work. The receiver is designed for a receiver outlet temperature up to 600 °C. Together with a complete molten salt system, the receiver will be integrated into the Multi-Focus-Tower (MFT) in Jülich (Germany). The paper describes the basic engineering of the receiver, the molten salt tower system and a laboratory corrosion setup. Y1 - 2020 U6 - https://doi.org/10.1063/5.0085895 N1 - SOLARPACES 2020: 26th International Conference on Concentrating Solar Power and Chemical Energy Systems, 28 September – 2 October 2020, Freiburg, Germany SP - 1 EP - 10 ER - TY - CHAP A1 - Kreyer, Jörg A1 - Müller, Marvin A1 - Esch, Thomas T1 - A Map-Based Model for the Determination of Fuel Consumption for Internal Combustion Engines as a Function of Flight Altitude N2 - In addition to very high safety and reliability requirements, the design of internal combustion engines (ICE) in aviation focuses on economic efficiency. The objective must be to design the aircraft powertrain optimized for a specific flight mission with respect to fuel consumption and specific engine power. Against this background, expert tools provide valuable decision-making assistance for the customer. In this paper, a mathematical calculation model for the fuel consumption of aircraft ICE is presented. This model enables the derivation of fuel consumption maps for different engine configurations. Depending on the flight conditions and based on these maps, the current and the integrated fuel consumption for freely definable flight emissions is calculated. For that purpose, an interpolation method is used, that has been optimized for accuracy and calculation time. The mission boundary conditions flight altitude and power requirement of the ICE form the basis for this calculation. The mathematical fuel consumption model is embedded in a parent program. This parent program presents the simulated fuel consumption by means of an example flight mission for a representative airplane. The focus of the work is therefore on reproducing exact consumption data for flight operations. By use of the empirical approaches according to Gagg-Farrar [1] the power and fuel consumption as a function of the flight altitude are determined. To substantiate this approaches, a 1-D ICE model based on the multi-physical simulation tool GT-Suite® has been created. This 1-D engine model offers the possibility to analyze the filling and gas change processes, the internal combustion as well as heat and friction losses for an ICE under altitude environmental conditions. Performance measurements on a dynamometer at sea level for a naturally aspirated ICE with a displacement of 1211 ccm used in an aviation aircraft has been done to validate the 1-D ICE model. To check the plausibility of the empirical approaches with respect to the fuel consumption and performance adjustment for the flight altitude an analysis of the ICE efficiency chain of the 1-D engine model is done. In addition, a comparison of literature and manufacturer data with the simulation results is presented. Y1 - 2020 U6 - https://doi.org/10.25967/490162 N1 - 68. Deutscher Luft- und Raumfahrtkongress 30.09.-02.10.2019, Darmstadt PB - DGLR CY - Bonn ER - TY - JOUR A1 - El Moussaoui, Noureddine A1 - Talbi, Sofian A1 - Atmane, Ilyas A1 - Kassmi, Khalil A1 - Schwarzer, Klemens A1 - Chayeb, Hamid A1 - Bachiri, Najib T1 - Feasibility of a new design of a Parabolic Trough Solar Thermal Cooker (PSTC) JF - Solar Energy N2 - In this article, we describe the structure, the functioning, and the tests of parabolic trough solar thermal cooker (PSTC). This oven is designed to meet the needs of rural residents, including Urban, which requires stable cooking temperatures above 200 °C. The cooking by this cooker is based on the concentration of the sun's rays on a glass vacuum tube and heating of the oil circulate in a big tube, located inside the glass tube. Through two small tubes, associated with large tube, the heated oil, rise and heats the pot of cooking pot containing the food to be cooked (capacity of 5 kg). This cooker is designed in Germany and extensively tested in Morocco for use by the inhabitants who use wood from forests. During a sunny day, having a maximum solar radiation around 720 W/m2 and temperature ambient around 26 °C, maximum temperatures recorded of the small tube, the large tube and the center of the pot are respectively: 370 °C, 270 °C and 260 °C. The cooking process with food at high (fries, ..), we show that the cooking oil temperature rises to 200 °C, after 1 h of heating, the cooking is done at a temperature of 120 °C for 20 min. These temperatures are practically stable following variations and decreases in the intensity of irradiance during the day. The comparison of these results with those of the literature shows an improvement of 30–50 % on the maximum value of the temperature with a heat storage that could reach 60 min of autonomy. All the results obtained show the good functioning of the PSTC and the feasibility of cooking food at high temperature (>200 °C). Y1 - 2020 U6 - https://doi.org/10.1016/j.solener.2020.03.079 SN - 0038-092X VL - 201 IS - Vol. 201 (May 2020) SP - 866 EP - 871 PB - Elsevier CY - Amsterdam ER - TY - RPRT A1 - Esch, Thomas A1 - Damm, Marc André A1 - Kalbhenn, Hartmut T1 - Auslegung und Simulation eines Hybridantriebs für den teilelektrischen Betrieb eines Luftfahrzeuges der allgemeinen Luftfahrt : Schlussbericht für das Forschungsvorhaben ; Förderperiode 01.07.2009 - 31.05.2012 T1 - HyFly ; Design and simulation of a partially electrified operatin of an aircraft of the general aviation Y1 - 2013 U6 - https://doi.org/10.2314/GBV:780055411 N1 - Report-Nr.: 1709X08 CY - Aachen ; Hannover ER - TY - JOUR A1 - Groß, Rolf Fritz A1 - Timmer, H. T1 - Energetische und betriebswirtschaftliche Bewertung von Kühlsystemen für Kühllager JF - HLH. Heizung, Lüftung/Klima, Haustechnik KW - Heizung KW - Lüftung KW - Klimatechnik KW - Lüftungstechnik KW - Haustechnik Y1 - 1998 SN - 1436-5103 VL - 49 IS - 9 SP - 74 EP - 77 PB - Springer CY - Düsseldorf ER - TY - CHAP A1 - Thulfaut, Christian A1 - Groß, Rolf Fritz A1 - Renz, Ulrich ED - Jamal, Rahman ED - Jaschinski, Hans T1 - Messwerterfassung und –auswertung mit LabView: Experimentelle Analyse der Mischungsgüte in Hybridzellenkühltürmen T2 - Virtuelle Instrumente in der Praxis. Begleitband zum Kongress VIP 2000 N2 - Zur Kühlung von Abwärmeströmen aus Kraftwerksprozessen werden in zunehmenden Maße Hybridzellenkühltürme mit Zwangskonvektion eingesetzt, deren wesentlicher Vorteil ihre geringe Bauhöhe ist. Um bei derartigen Kühltürmen eine Sichtbehinderung oder Glatteisgefährdung durch bodennahen Nebel zu vermeiden, muss durch eine optimale Vermischung des Trocken- und Naßluftanteils gewährleistet sein, daß aus der Kühlturmkrone keine Nebelschwaden austreten. In Zusammenarbeit mit der Industrie betreibt der Lehrstuhl für Wärmeübertragung und Klimatechnik der RWTH Aachen einen Versuchsstand zur Erfassung der Mischungsgüte in Hybridzellenkühltürmen. In maßstabsgerechter Nachbildung können dabei am Modell alle relevanten Einflußgrößen wie Kühlturmgeometrie, Gestaltung zusätzlicher Mischeinbauten sowie die Betriebsparameter variiert werden. Mit Hilfe einer unter LabView 5.01 erstellten Software werden sowohl die l3etriebszustüncle online überwacht, als auch die benötigten Meßwerte zur Bestimmung der Mischungsgüte erfaßt. Über die grafische Oberfläche können sämtliche Meßoptionen gesteuert sowie alle Meßdaten visualisiert und kontrolliert werden. In das LabView-Programm sind darüber hinaus Routinen zur Auswertung der Daten implementiert worden, die sowohl eine direkte Darstellung der Ergebnisse in Form von Diagrammen ermöglichen, als auch zur Weiterverarbeitung einen Datenexport in eine Microsoft- Excel-Tabelle vorsehen. N2 - The Institute of Heat Transfer and Air Conditioning at the Aachen University of Technology operates in co-operation with industrial partners a test facility in order to investigate mixture quality in hybrid cooling towers. In a scaled mock-up a variation of all relevant data such as the geometry of the cooling tower, the design of additional mixers and the operation parameters could be realized. A software tool, created with LabView 5.01, offers the possibility to control the whole process and to measure all relevant quantities. The graphic user interface permits an online control and a visualization of the measured values. Beyond this the program is not only able to evaluate the data and to represent the results in form of diagrams, but also to export the data directly into an Microsoft-Excel-sheet for further analysing. Y1 - 2000 SN - 3-7785-2789-4 (print) SP - 54 EP - 60 PB - Hüthig CY - Heidelberg ER -