TY - JOUR A1 - Abel, Alexander A1 - Kahmann, Stephanie Lucina A1 - Mellon, Stephen A1 - Staat, Manfred A1 - Jung, Alexander T1 - An open-source tool for the validation of finite element models using three-dimensional full-field measurements JF - Medical Engineering & Physics N2 - Three-dimensional (3D) full-field measurements provide a comprehensive and accurate validation of finite element (FE) models. For the validation, the result of the model and measurements are compared based on two respective point-sets and this requires the point-sets to be registered in one coordinate system. Point-set registration is a non-convex optimization problem that has widely been solved by the ordinary iterative closest point algorithm. However, this approach necessitates a good initialization without which it easily returns a local optimum, i.e. an erroneous registration. The globally optimal iterative closest point (Go-ICP) algorithm has overcome this drawback and forms the basis for the presented open-source tool that can be used for the validation of FE models using 3D full-field measurements. The capability of the tool is demonstrated using an application example from the field of biomechanics. Methodological problems that arise in real-world data and the respective implemented solution approaches are discussed. Y1 - 2020 U6 - https://doi.org/10.1016/j.medengphy.2019.10.015 SN - 1350-4533 VL - 77 SP - 125 EP - 129 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Savitskaya, I.S. A1 - Kistaubayeva, A.S. A1 - Ignatova, L.V. A1 - Digel, Ilya T1 - Antimicrobial and wound healing properties of a bacterial cellulose based material containing B. subtilis cells JF - Heliyon Y1 - 2019 U6 - https://doi.org/10.1016/j.heliyon.2019.e02592 SN - 2405-8440 VL - 5 IS - 10 SP - Artikelnummer e02592 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Gehler, M. A1 - Ober-Blöbaum, S. A1 - Dachwald, Bernd T1 - Application of discrete mechanics and optimal control to spacecraft in non-keplerian motion around small solar system bodies T2 - Procceedings of the 60th International Astronautical Congress N2 - Prolonged operations close to small solar system bodies require a sophisticated control logic to minimize propellant mass and maximize operational efficiency. A control logic based on Discrete Mechanics and Optimal Control (DMOC) is proposed and applied to both conventionally propelled and solar sail spacecraft operating at an arbitrarily shaped asteroid in the class of Itokawa. As an example, stand-off inertial hovering is considered, recently identified as a challenging part of the Marco Polo mission. The approach is easily extended to stand-off orbits. We show that DMOC is applicable to spacecraft control at small objects, in particular with regard to the fact that the changes in gravity are exploited by the algorithm to optimally control the spacecraft position. Furthermore, we provide some remarks on promising developments. KW - Spacecraft Y1 - 2009 SN - 978-161567908-9 N1 - 60th International Astronautical Congress 2009, IAC 2009; Daejeon; South Korea; 12 October 2009 through 16 October 2009 SP - 1360 EP - 1371 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hunker, Jan L. A1 - Gossmann, Matthias A1 - Raman, Aravind Hariharan A1 - Linder, Peter T1 - Artificial neural networks in cardiac safety assessment: Classification of chemotherapeutic compound effects on hiPSC-derived cardiomyocyte contractility JF - Journal of Pharmacological and Toxicological Methods Y1 - 2021 U6 - https://doi.org/10.1016/j.vascn.2021.107044 SN - 1056-8719 VL - 111 IS - Article number 107044 PB - Elsevier CY - New York ER - TY - CHAP A1 - Lanzl, I. A1 - Seidova, S.-F. A1 - Dühring, C. von A1 - Kotliar, Konstantin ED - Erb, Carl T1 - Befunde der dynamischen Gefäßanalyse am Auge bei Gesunden und Glaukom-Patienten mit praxisrelevanter Bedeutung T2 - Mikrozirkulation beim Glaukom Y1 - 2009 N1 - Search on Glaucoma SP - 33 EP - 39 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Horbach, Andreas A1 - Staat, Manfred A1 - Perez-Viana, Daniel A1 - Simmen, Hans-Peter A1 - Neuhaus, Valentin A1 - Pape, Hans-Christoph A1 - Prescher, Andreas A1 - Ciritsis, Bernhard T1 - Biomechanical in vitro examination of a standardized low-volume tubular femoroplasty JF - Clinical Biomechanics N2 - Background Osteoporosis is associated with the risk of fractures near the hip. Age and comorbidities increase the perioperative risk. Due to the ageing population, fracture of the proximal femur also proves to be a socio-economic problem. Preventive surgical measures have hardly been used so far. Methods 10 pairs of human femora from fresh cadavers were divided into control and low-volume femoroplasty groups and subjected to a Hayes fall-loading fracture test. The results of the respective localization and classification of the fracture site, the Singh index determined by computed tomography (CT) examination and the parameters in terms of fracture force, work to fracture and stiffness were evaluated statistically and with the finite element method. In addition, a finite element parametric study with different position angles and variants of the tubular geometry of the femoroplasty was performed. Findings Compared to the control group, the work to fracture could be increased by 33.2%. The fracture force increased by 19.9%. The used technique and instrumentation proved to be standardized and reproducible with an average poly(methyl methacrylate) volume of 10.5 ml. The parametric study showed the best results for the selected angle and geometry. Interpretation The cadaver studies demonstrated the biomechanical efficacy of the low-volume tubular femoroplasty. The numerical calculations confirmed the optimal choice of positioning as well as the inner and outer diameter of the tube in this setting. The standardized minimally invasive technique with the instruments developed for it could be used in further comparative studies to confirm the measured biomechanical results. Y1 - 2020 U6 - https://doi.org/10.1016/j.clinbiomech.2020.105104 VL - 80 IS - Art. 105104 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Jan Thimo, Grundmann A1 - Bauer, Waldemar A1 - Biele, Jens A1 - Boden, Ralf A1 - Ceriotti, Matteo A1 - Cordero, Federico A1 - Dachwald, Bernd A1 - Dumont, Etienne A1 - Grimm, Christian D. A1 - Hercik, David T1 - Capabilities of Gossamer-1 derived small spacecraft solar sails carrying Mascot-derived nanolanders for in-situ surveying of NEAs JF - Acta Astronautica Y1 - 2019 U6 - https://doi.org/10.1016/j.actaastro.2018.03.019 SN - 0094-5765 VL - 156 IS - 3 SP - 330 EP - 362 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Neumaier, Felix A1 - Weiss, Miriam A1 - Veldeman, Michael A1 - Kotliar, Konstantin A1 - Wiesmann, Martin A1 - Schulze-Steinen, Henna A1 - Höllig, Anke A1 - Clusmann, Hans A1 - Schubert, Gerrit Alexander A1 - Albanna, Walid T1 - Changes in endogenous daytime melatonin levels after aneurysmal subarachnoid hemorrhage – preliminary findings from an observational cohort study JF - Clinical Neurology and Neurosurgery N2 - Aneurysmal subarachnoid hemorrhage (aSAH) is associated with early and delayed brain injury due to several underlying and interrelated processes, which include inflammation, oxidative stress, endothelial, and neuronal apoptosis. Treatment with melatonin, a cytoprotective neurohormone with anti-inflammatory, anti-oxidant and anti-apoptotic effects, has been shown to attenuate early brain injury (EBI) and to prevent delayed cerebral vasospasm in experimental aSAH models. Less is known about the role of endogenous melatonin for aSAH outcome and how its production is altered by the pathophysiological cascades initiated during EBI. In the present observational study, we analyzed changes in melatonin levels during the first three weeks after aSAH. KW - constructive alignment KW - examination KW - long-term retention KW - multimodal KW - practical learning Y1 - 2021 U6 - https://doi.org/10.1016/j.clineuro.2021.106870 SN - 0303-8467 VL - 208 IS - Article No.: 106870 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Knox, Ronald A1 - Bruggemann, Andrea A1 - Gossmann, Matthias A1 - Thomas, Ulrich A1 - Horváth, András A1 - Dragicevic, Elena A1 - Stoelzle-Feix, Sonja A1 - Fertig, Niels A1 - Jung, Alexander A1 - Raman, Aravind Hariharan A1 - Staat, Manfred A1 - Linder, Peter T1 - Combining physiological relevance and throughput for in vitro cardiac contractility measurement JF - Biophysical Journal N2 - Despite increasing acceptance of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) in safety pharmacology, controversy remains about the physiological relevance of existing in vitro models for their mechanical testing. We hypothesize that existing signs of immaturity of the cell models result from an improper mechanical environment. We cultured hiPSC-CMs in a 96-well format on hyperelastic silicone membranes imitating their native mechanical environment, resulting in physiological responses to compound stimuli.We validated cell responses on the FLEXcyte 96, with a set of reference compounds covering a broad range of cellular targets, including ion channel modulators, adrenergic receptor modulators and kinase inhibitors. Acute (10 - 30 min) and chronic (up to 7 days) effects were investigated. Furthermore, the measurements were complemented with electromechanical models based on electrophysiological recordings of the used cell types.hiPSC-CMs were cultured on freely-swinging, ultra-thin and hyperelastic silicone membranes. The weight of the cell culture medium deflects the membranes downwards. Rhythmic contraction of the hiPSC-CMs resulted in dynamic deflection changes which were quantified by capacitive distance sensing. The cells were cultured for 7 days prior to compound addition. Acute measurements were conducted 10-30 minutes after compound addition in standard culture medium. For chronic treatment, compound-containing medium was replaced daily for up to 7 days. Electrophysiological properties of the employed cell types were recorded by automated patch-clamp (Patchliner) and the results were integrated into the electromechanical model of the system.Calcium channel agonist S Bay K8644 and beta-adrenergic stimulator isoproterenol induced significant positive inotropic responses without additional external stimulation. Kinase inhibitors displayed cardiotoxic effects on a functional level at low concentrations. The system-integrated analysis detected alterations in beating shape as well as frequency and arrhythmic events and we provide a quantitative measure of these. Y1 - 2020 U6 - https://doi.org/10.1016/j.bpj.2019.11.3104 SN - 0006-3495 N1 - Raman, Arayind Hariharan im Artikel unter dem Namen: Raman, Alexander H. VL - 118 IS - Issue 3, Supplement 1 SP - 570a PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Corrigendum to “Flight style optimization in ski jumping on normal, large, and ski flying hills” [J. Biomech 47 (2014) 716–722] JF - Journals of Biomechanics Y1 - 2018 U6 - https://doi.org/10.1016/j.jbiomech.2018.02.001 SN - 0021-9290 N1 - refers to Journal of Biomechanics Vol 47, Issue 3, Pages 716-722: https://doi.org/10.1016/j.jbiomech.2013.11.021 SP - 313 PB - Elsevier CY - Amsterdam ER -