TY - JOUR A1 - Vögele, Stefan A1 - Rübbelke, Dirk A1 - Govorukha, Kristina A1 - Grajewski, Matthias T1 - Socio-technical scenarios for energy-intensive industries: the future of steel production in Germany JF - Climatic Change Y1 - 2019 U6 - http://dx.doi.org/10.1007/s10584-019-02366-0 SN - 0165-0009 SP - 1 EP - 16 PB - Springer CY - Berlin ER - TY - JOUR A1 - Stulpe, Werner T1 - Aspects of the Quantum-Classical Connection Based on Statistical Maps JF - Foundations of Physics Y1 - 2019 U6 - http://dx.doi.org/10.1007/s10701-019-00269-9 VL - 49 IS - 6 SP - 677 EP - 692 PB - Springer CY - Berlin ER - TY - JOUR A1 - Krome, Cornelia A1 - Höft, Jan A1 - Sander, Volker T1 - Clustering time series applied to energy markets JF - Energy Informatics Y1 - 2019 U6 - http://dx.doi.org/10.1186/s42162-019-0076-0 SN - 2520-8942 VL - 2 IS - Article numer 17 SP - 1 EP - 20 PB - Springer CY - Berlin ER - TY - CHAP A1 - Kotliar, Konstantin ED - Pallikaris, I. ED - Tsilimbaris, M. K. ED - Dastiridou, A. I. T1 - Ocular rigidity: clinical approach T2 - Ocular Rigidity, Biomechanics and Hydrodynamics of the Eye N2 - The term ocular rigidity is widely used in clinical ophthalmology. Generally it is assumed as a resistance of the whole eyeball to mechanical deformation and relates to biomechanical properties of the eye and its tissues. Basic principles and formulas for clinical tonometry, tonography and pulsatile ocular blood flow measurements are based on the concept of ocular rigidity. There is evidence for altered ocular rigidity in aging, in several eye diseases and after eye surgery. Unfortunately, there is no consensual view on ocular rigidity: it used to make a quite different sense for different people but still the same name. Foremost there is no clear consent between biomechanical engineers and ophthalmologists on the concept. Moreover ocular rigidity is occasionally characterized using various parameters with their different physical dimensions. In contrast to engineering approach, clinical approach to ocular rigidity claims to characterize the total mechanical response of the eyeball to its deformation without any detailed considerations on eye morphology or material properties of its tissues. Further to the previous chapter this section aims to describe clinical approach to ocular rigidity from the perspective of an engineer in an attempt to straighten out this concept, to show its advantages, disadvantages and various applications. KW - Coefficient of ocular rigidity KW - Eyeball KW - Corneo-scleral shell KW - Pressure-volume relationship KW - Differential tonometry Y1 - 2021 SN - 978-3-030-64422-2 U6 - http://dx.doi.org/10.1007/978-3-030-64422-2_2 SP - 15 EP - 43 PB - Springer CY - Cham ER - TY - JOUR A1 - Kuerten, David A1 - Kotliar, Konstantin A1 - Fuest, Matthias A1 - Walter, Peter A1 - Hollstein, Muriel A1 - Plange, Niklas ED - Neri, Piergiorgio T1 - Does hemispheric vascular regulation differ significantly in glaucoma patients with altitudinal visual field asymmetry? A single-center, prospective study JF - International Ophthalmology N2 - Purpose Vascular risk factors and ocular perfusion are heatedly discussed in the pathogenesis of glaucoma. The retinal vessel analyzer (RVA, IMEDOS Systems, Germany) allows noninvasive measurement of retinal vessel regulation. Significant differences especially in the veins between healthy subjects and patients suffering from glaucoma were previously reported. In this pilot-study we investigated if localized vascular regulation is altered in glaucoma patients with altitudinal visual field defect asymmetry. Methods 15 eyes of 12 glaucoma patients with advanced altitudinal visual field defect asymmetry were included. The mean defect was calculated for each hemisphere separately (-20.99 ± 10.49 pro- found hemispheric visual field defect vs -7.36 ± 3.97 dB less profound hemisphere). After pupil dilation, RVA measurements of retinal arteries and veins were conducted using the standard protocol. The superior and inferior retinal vessel reactivity were measured consecutively in each eye. Results Significant differences were recorded in venous vessel constriction after flicker light stimulation and overall amplitude of the reaction (p \ 0.04 and p \ 0.02 respectively) in-between the hemispheres spheres. Vessel reaction was higher in the hemisphere corresponding to the more advanced visual field defect. Arterial diameters reacted similarly, failing to reach statistical significance. Conclusion Localized retinal vessel regulation is significantly altered in glaucoma patients with asymmetri altitudinal visual field defects. Veins supplying the hemisphere concordant to a less profound visual field defect show diminished diameter changes. Vascular dysregulation might be particularly important in early glaucoma stages prior to a significant visual field defect. KW - Glaucoma KW - Visual field asymmetry KW - Ocular blood flow KW - RVA KW - Vascular response Y1 - 2021 SN - 1573-2630 U6 - http://dx.doi.org/10.1007/s10792-021-01876-0 VL - 41 IS - 41 SP - 3109 EP - 3119 PB - Springer CY - Berlin ER - TY - JOUR A1 - Lenz, Maximilian A1 - Kahmann, Stephanie Lucina A1 - Behbahani, Mehdi A1 - Pennig, Lenhard A1 - Hackl, Michael A1 - Leschinger, Tim A1 - Müller, Lars Peter A1 - Wegmann, Kilian T1 - Influence of rotator cuff preload on fracture configuration in proximal humerus fractures: a proof of concept for fracture simulation JF - Archives of Orthopaedic and Trauma Surgery N2 - Introduction In regard of surgical training, the reproducible simulation of life-like proximal humerus fractures in human cadaveric specimens is desirable. The aim of the present study was to develop a technique that allows simulation of realistic proximal humerus fractures and to analyse the influence of rotator cuff preload on the generated lesions in regards of fracture configuration. Materials and methods Ten cadaveric specimens (6 left, 4 right) were fractured using a custom-made drop-test bench, in two groups. Five specimens were fractured without rotator cuff preload, while the other five were fractured with the tendons of the rotator cuff preloaded with 2 kg each. The humeral shaft and the shortened scapula were potted. The humerus was positioned at 90° of abduction and 10° of internal rotation to simulate a fall on the elevated arm. In two specimens of each group, the emergence of the fractures was documented with high-speed video imaging. Pre-fracture radiographs were taken to evaluate the deltoid-tuberosity index as a measure of bone density. Post-fracture X-rays and CT scans were performed to define the exact fracture configurations. Neer’s classification was used to analyse the fractures. Results In all ten cadaveric specimens life-like proximal humerus fractures were achieved. Two III-part and three IV-part fractures resulted in each group. The preloading of the rotator cuff muscles had no further influence on the fracture configuration. High-speed videos of the fracture simulation revealed identical fracture mechanisms for both groups. We observed a two-step fracture mechanism, with initial impaction of the head segment against the glenoid followed by fracturing of the head and the tuberosities and then with further impaction of the shaft against the acromion, which lead to separation of the tuberosities. Conclusion A high energetic axial impulse can reliably induce realistic proximal humerus fractures in cadaveric specimens. The preload of the rotator cuff muscles had no influence on initial fracture configuration. Therefore, fracture simulation in the proximal humerus is less elaborate. Using the presented technique, pre-fractured specimens are available for real-life surgical education. KW - Proximal humerus fracture KW - Biomechanical simulation KW - Fracture configuration KW - Fracture simulation KW - Rotator cuff Y1 - 2022 U6 - http://dx.doi.org/10.1007/s00402-022-04471-9 SN - 1434-3916 PB - Springer CY - Berlin, Heidelberg ER - TY - JOUR A1 - Schneider, Jules A1 - Schwabedal, Justus T. C. A1 - Bialonski, Stephan T1 - Schlafspindeln – Funktion, Detektion und Nutzung als Biomarker für die psychiatrische Diagnostik JF - Der Nervenarzt N2 - Hintergrund: Die Schlafspindel ist ein Graphoelement des Elektroenzephalogramms (EEG), das im Leicht- und Tiefschlaf beobachtet werden kann. Veränderungen der Spindelaktivität wurden für verschiedene psychiatrische Erkrankungen beschrieben. Schlafspindeln zeigen aufgrund ihrer relativ konstanten Eigenschaften Potenzial als Biomarker in der psychiatrischen Diagnostik. Methode: Dieser Beitrag liefert einen Überblick über den Stand der Wissenschaft zu Eigenschaften und Funktionen der Schlafspindeln sowie über beschriebene Veränderungen der Spindelaktivität bei psychiatrischen Erkrankungen. Verschiedene methodische Ansätze und Ausblicke zur Spindeldetektion werden hinsichtlich deren Anwendungspotenzial in der psychiatrischen Diagnostik erläutert. Ergebnisse und Schlussfolgerung: Während Veränderungen der Spindelaktivität bei psychiatrischen Erkrankungen beschrieben wurden, ist deren exaktes Potenzial für die psychiatrische Diagnostik noch nicht ausreichend erforscht. Diesbezüglicher Erkenntnisgewinn wird in der Forschung gegenwärtig durch ressourcenintensive und fehleranfällige Methoden zur manuellen oder automatisierten Spindeldetektion ausgebremst. Neuere Detektionsansätze, die auf Deep-Learning-Verfahren basieren, könnten die Schwierigkeiten bisheriger Detektionsmethoden überwinden und damit neue Möglichkeiten für die praktisch KW - Schlafspindeldetektion KW - Psychiatrische Biomarker KW - · Psychiatrische Erkrankungen/Diagnostik KW - Elektroenzephalographie KW - Deep Learning Y1 - 2022 U6 - http://dx.doi.org/10.1007/s00115-022-01340-z SN - 1433-0407 SP - 1 EP - 8 PB - Springer CY - Berlin, Heidelberg ER - TY - CHAP A1 - Bozakov, Zdravko A1 - Sander, Volker T1 - OpenFlow: A Perspective for Building Versatile Networks T2 - Network-Embedded Management and Applications Y1 - 2013 SN - 978-1-4419-6769-5 U6 - http://dx.doi.org/10.1007/978-1-4419-6769-5_11 SP - 217 EP - 245 PB - Springer CY - New York, NY ER - TY - JOUR A1 - Hugenroth, Kristin A1 - Borchardt, Ralf A1 - Ritter, Philine A1 - Groß‑Hardt, Sascha A1 - Meyns, Bart A1 - Verbelen, Tom A1 - Steinseifer, Ulrich A1 - Kaufmann, Tim A. S. A1 - Engelmann, Ulrich M. T1 - Optimizing cerebral perfusion and hemodynamics during cardiopulmonary bypass through cannula design combining in silico, in vitro and in vivo input JF - Scientific Reports N2 - Cardiopulmonary bypass (CPB) is a standard technique for cardiac surgery, but comes with the risk of severe neurological complications (e.g. stroke) caused by embolisms and/or reduced cerebral perfusion. We report on an aortic cannula prototype design (optiCAN) with helical outflow and jet-splitting dispersion tip that could reduce the risk of embolic events and restores cerebral perfusion to 97.5% of physiological flow during CPB in vivo, whereas a commercial curved-tip cannula yields 74.6%. In further in vitro comparison, pressure loss and hemolysis parameters of optiCAN remain unaffected. Results are reproducibly confirmed in silico for an exemplary human aortic anatomy via computational fluid dynamics (CFD) simulations. Based on CFD simulations, we firstly show that optiCAN design improves aortic root washout, which reduces the risk of thromboembolism. Secondly, we identify regions of the aortic intima with increased risk of plaque release by correlating areas of enhanced plaque growth and high wall shear stresses (WSS). From this we propose another easy-to-manufacture cannula design (opti2CAN) that decreases areas burdened by high WSS, while preserving physiological cerebral flow and favorable hemodynamics. With this novel cannula design, we propose a cannulation option to reduce neurological complications and the prevalence of stroke in high-risk patients after CPB. Y1 - 2021 U6 - http://dx.doi.org/10.1038/s41598-021-96397-2 SN - 2045-2322 VL - 11 IS - Art. No. 16800 SP - 1 EP - 12 PB - Springer CY - Berlin ER - TY - JOUR A1 - Poghossian, Arshak A1 - Weil, M. A1 - Cherstvy, A. G. A1 - Schöning, Michael Josef T1 - Electrical monitoring of polyelectrolyte multilayer formation by means of capacitive field-effect devices JF - Analytical and bioanalytical chemistry N2 - The semiconductor field-effect platform represents a powerful tool for detecting the adsorption and binding of charged macromolecules with direct electrical readout. In this work, a capacitive electrolyte–insulator–semiconductor (EIS) field-effect sensor consisting of an Al-p-Si-SiO2 structure has been applied for real-time in situ electrical monitoring of the layer-by-layer formation of polyelectrolyte (PE) multilayers (PEM). The PEMs were deposited directly onto the SiO2 surface without any precursor layer or drying procedures. Anionic poly(sodium 4-styrene sulfonate) and cationic weak polyelectrolyte poly(allylamine hydrochloride) have been chosen as a model system. The effect of the ionic strength of the solution, polyelectrolyte concentration, number and polarity of the PE layers on the characteristics of the PEM-modified EIS sensors have been studied by means of capacitance–voltage and constant-capacitance methods. In addition, the thickness, surface morphology, roughness and wettabilityof the PE mono- and multilayers have been characterised by ellipsometry, atomic force microscopy and water contact-angle methods, respectively. To explain potential oscillations on the gate surface and signal behaviour of the capacitive field-effect EIS sensor modified with a PEM, a simplified electrostatic model that takes into account the reduced electrostatic screening of PE charges by mobile ions within the PEM has been proposed and discussed. Y1 - 2013 U6 - http://dx.doi.org/10.1007/s00216-013-6951-9 SN - 1432-1130 ; 1618-2642 VL - 405 IS - 20 SP - 6425 EP - 6436 PB - Springer CY - Berlin ER -