TY - JOUR A1 - Fiedler, Thomas M. A1 - Orzada, Stephan A1 - Flöser, Martina A1 - Rietsch, Stefan H. G. A1 - Schmidt, Simon A1 - Stelter, Jonathan K. A1 - Wittrich, Marco A1 - Quick, Harald H. A1 - Bitz, Andreas A1 - Ladd, Mark E. T1 - Performance and safety assessment of an integrated transmit array for body imaging at 7 T under consideration of specificabsorption rate, tissue temperature, and thermal dose JF - NMR in Biomedicine N2 - In this study, the performance of an integrated body-imaging array for 7 T with 32 radiofrequency (RF) channels under consideration of local specific absorption rate (SAR), tissue temperature, and thermal dose limits was evaluated and the imaging performance was compared with a clinical 3 T body coil. Thirty-two transmit elements were placed in three rings between the bore liner and RF shield of the gradient coil. Slice-selective RF pulse optimizations for B1 shimming and spokes were performed for differently oriented slices in the body under consideration of realistic constraints for power and local SAR. To improve the B1+ homogeneity, safety assessments based on temperature and thermal dose were performed to possibly allow for higher input power for the pulse optimization than permissible with SAR limits. The results showed that using two spokes, the 7 T array outperformed the 3 T birdcage in all the considered regions of interest. However, a significantly higher SAR or lower duty cycle at 7 T is necessary in some cases to achieve similar B1+ homogeneity as at 3 T. The homogeneity in up to 50 cm-long coronal slices can particularly benefit from the high RF shim performance provided by the 32 RF channels. The thermal dose approach increases the allowable input power and the corresponding local SAR, in one example up to 100 W/kg, without limiting the exposure time necessary for an MR examination. In conclusion, the integrated antenna array at 7 T enables a clinical workflow for body imaging and comparable imaging performance to a conventional 3 T clinical body coil. KW - body imaging at 7 T MRI KW - thermal dose KW - tissue temperature KW - transmit antenna arrays Y1 - 2022 U6 - https://doi.org/10.1002/nbm.4656 SN - 0952-3480 (Print) SN - 1099-1492 (Online) VL - 35 IS - 5 SP - 1 EP - 17 PB - Wiley ER - TY - JOUR A1 - El-Deib, Khaled A1 - Butenweg, Christoph A1 - Klinkel, Sven ED - Jesse, Dirk T1 - Erdbebennachweis von Mauerwerksbauten mit realistischen Modellen und erhöhten Verhaltensbeiwerten JF - Mauerwerk N2 - Die Anwendung des linearen Nachweiskonzepts auf Mauerwerksbauten führt dazu, dass bereits heute Standsicherheitsnachweise für Gebäude mit üblichen Grundrissen in Gebieten mit moderaten Erdbebeneinwirkungen nicht mehr geführt werden können. Diese Problematik wird sich in Deutschland mit der Einführung kontinuierlicher probabilistischer Erdbebenkarten weiter verschärfen. Aufgrund der Erhöhung der seismischen Einwirkungen, die sich vielerorts ergibt, ist es erforderlich, die vorhandenen, bislang nicht berücksichtigten Tragfähigkeitsreserven in nachvollziehbaren Nachweiskonzepten in der Baupraxis verfügbar zu machen. Der vorliegende Beitrag stellt ein Konzept für die gebäudespezifische Ermittlung von erhöhten Verhaltensbeiwerten vor. Die Verhaltensbeiwerte setzen sich aus drei Anteilen zusammen, mit denen die Lastumverteilung im Grundriss, die Verformungsfähigkeit und Energiedissipation sowie die Überfestigkeiten berücksichtigt werden. Für die rechnerische Ermittlung dieser drei Anteile wird ein nichtlineares Nachweiskonzept auf Grundlage von Pushover-Analysen vorgeschlagen, in denen die Interaktionen von Wänden und Geschossdecken durch einen Einspanngrad beschrieben werden. Für die Bestimmung der Einspanngrade wird ein nichtlinearer Modellierungsansatz eingeführt, mit dem die Interaktion von Wänden und Decken abgebildet werden kann. Die Anwendung des Konzepts mit erhöhten gebäudespezifischen Verhaltensbeiwerten wird am Beispiel eines Mehrfamilienhauses aus Kalksandsteinen demonstriert. Die Ergebnisse der linearen Nachweise mit erhöhten Verhaltensbeiwerten für dieses Gebäude liegen deutlich näher an den Ergebnissen nichtlinearer Nachweise und somit bleiben übliche Grundrisse in Erdbebengebieten mit den traditionellen linearen Rechenansätzen nachweisbar. N2 - Seismic verification of masonry buildings based on realistic calculation models and increased behavior factorsWith the application of the traditional linear verification con­cept to masonry structures it is already no longer possible to carry out structural safety verifications even for buildings with standard ground plan configurations in areas with moderate seismicity. This problem will be exacerbated in Germany with the introduction of continuous probabilistic earthquake maps. Due to the increased seismic actions, it is necessary to make the existing load­bearing capacity reserves that have not yet been taken into account available in comprehensible verifica­tion concepts in construction practice. This article presents a concept for the building­specific determination of increased behavior factors. The behavior factors are composed of three components, which take into account the load redistribution in ground plans, the deformation capability and energy dissipation and all kinds of overstrength effects. For the calculation of these three components, a non­linear verification concept based on pushover analyses is applied, in which the interac­tions of walls and floor slabs are described by a level of re­straint. A non­linear modeling approach of the overall building is introduced for the determination of the restraint levels, with which the interaction of walls and floor slabs can be simulated. The results of the linear verifications with increased behavior factors for this building are significantly closer to the results of non­linear verifications and thus the standard ground plan con­figurations in areas with moderate seismicity can still be veri­fied with the traditional linear calculation approaches. KW - Mauerwerksbauten KW - Erdbebeneinwirkung KW - Bemessung KW - Verhaltensbeiwerte KW - Pushover­Analysen Y1 - 2021 U6 - https://doi.org/10.1002/dama.202110014 SN - 1437-1022 SN - 1432-3427 VL - 2021 IS - 3 SP - 110 EP - 119 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Hoffmann, Andreas A1 - Rohrbach, Felix A1 - Uhl, Matthias A1 - Ceblin, Maximilian A1 - Bauer, Thomas A1 - Mallah, Marcel A1 - Jacob, Timo A1 - Heuermann, Holger A1 - Kuehne, Alexander J. C. T1 - Atmospheric pressure plasma-jet treatment of polyacrylonitrile-nonwovens—Stabilization and roll-to-roll processing JF - Journal of Applied Polymer Science N2 - Carbon nanofiber nonwovens represent a powerful class of materials with prospective application in filtration technology or as electrodes with high surface area in batteries, fuel cells, and supercapacitors. While new precursor-to-carbon conversion processes have been explored to overcome productivity restrictions for carbon fiber tows, alternatives for the two-step thermal conversion of polyacrylonitrile precursors into carbon fiber nonwovens are absent. In this work, we develop a continuous roll-to-roll stabilization process using an atmospheric pressure microwave plasma jet. We explore the influence of various plasma-jet parameters on the morphology of the nonwoven and compare the stabilized nonwoven to thermally stabilized samples using scanning electron microscopy, differential scanning calorimetry, and infrared spectroscopy. We show that stabilization with a non-equilibrium plasma-jet can be twice as productive as the conventional thermal stabilization in a convection furnace, while producing electrodes of comparable electrochemical performance. KW - batteries and fuel cells KW - electrospinning KW - fibers KW - irradiation KW - porous materials Y1 - 2022 U6 - https://doi.org/10.1002/app.52887 SN - 0021-8995 (Print) SN - 1097-4628 (Online) N1 - Weitere Informationen: Bundesministerium für Bildung und Forschung, Fördernummer: 13XP5036E. Deutsche Forschungsgemeinschaft, Fördernummern: 390874152, 441209207, 327886311 VL - 139 IS - 37 SP - 1 EP - 9 PB - Wiley ER - TY - JOUR A1 - Heieis, Jule A1 - Böcker, Jonas A1 - D'Angelo, Olfa A1 - Mittag, Uwe A1 - Albracht, Kirsten A1 - Schönau, Eckhard A1 - Meyer, Andreas A1 - Voigtmann, Thomas A1 - Rittweger, Jörn T1 - Curvature of gastrocnemius muscle fascicles as function of muscle–tendon complex length and contraction in humans JF - Physiological Reports N2 - It has been shown that muscle fascicle curvature increases with increasing contraction level and decreasing muscle–tendon complex length. The analyses were done with limited examination windows concerning contraction level, muscle–tendon complex length, and/or intramuscular position of ultrasound imaging. With this study we aimed to investigate the correlation between fascicle arching and contraction, muscle–tendon complex length and their associated architectural parameters in gastrocnemius muscles to develop hypotheses concerning the fundamental mechanism of fascicle curving. Twelve participants were tested in five different positions (90°/105°*, 90°/90°*, 135°/90°*, 170°/90°*, and 170°/75°*; *knee/ankle angle). They performed isometric contractions at four different contraction levels (5%, 25%, 50%, and 75% of maximum voluntary contraction) in each position. Panoramic ultrasound images of gastrocnemius muscles were collected at rest and during constant contraction. Aponeuroses and fascicles were tracked in all ultrasound images and the parameters fascicle curvature, muscle–tendon complex strain, contraction level, pennation angle, fascicle length, fascicle strain, intramuscular position, sex and age group were analyzed by linear mixed effect models. Mean fascicle curvature of the medial gastrocnemius increased with contraction level (+5 m−1 from 0% to 100%; p = 0.006). Muscle–tendon complex length had no significant impact on mean fascicle curvature. Mean pennation angle (2.2 m−1 per 10°; p < 0.001), inverse mean fascicle length (20 m−1 per cm−1; p = 0.003), and mean fascicle strain (−0.07 m−1 per +10%; p = 0.004) correlated with mean fascicle curvature. Evidence has also been found for intermuscular, intramuscular, and sex-specific intramuscular differences of fascicle curving. Pennation angle and the inverse fascicle length show the highest predictive capacities for fascicle curving. Due to the strong correlations between pennation angle and fascicle curvature and the intramuscular pattern of curving we suggest for future studies to examine correlations between fascicle curvature and intramuscular fluid pressure. KW - biomechanics KW - connective tissue KW - physiology KW - ultrasound Y1 - 2023 U6 - https://doi.org/10.14814/phy2.15739 SN - 2051-817X VL - 11 IS - 11 SP - e15739, Seite 1-11 PB - Wiley ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Orzada, Stephan A1 - Flöser, Martina A1 - Rietsch, Stefan H. G. A1 - Quick, Harald H. A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - Performance analysis of integrated RF microstrip transmit antenna arrays with high channel count for body imaging at 7 T JF - NMR in Biomedicine N2 - The aim of the current study was to investigate the performance of integrated RF transmit arrays with high channel count consisting of meander microstrip antennas for body imaging at 7 T and to optimize the position and number of transmit ele- ments. RF simulations using multiring antenna arrays placed behind the bore liner were performed for realistic exposure conditions for body imaging. Simulations were performed for arrays with as few as eight elements and for arrays with high channel counts of up to 48 elements. The B1+ field was evaluated regarding the degrees of freedom for RF shimming in the abdomen. Worst-case specific absorption rate (SARwc ), SAR overestimation in the matrix compression, the number of virtual obser- vation points (VOPs) and SAR efficiency were evaluated. Constrained RF shimming was performed in differently oriented regions of interest in the body, and the devia- tion from a target B1+ field was evaluated. Results show that integrated multiring arrays are able to generate homogeneous B1+ field distributions for large FOVs, espe- cially for coronal/sagittal slices, and thus enable body imaging at 7 T with a clinical workflow; however, a low duty cycle or a high SAR is required to achieve homoge- neous B1+ distributions and to exploit the full potential. In conclusion, integrated arrays allow for high element counts that have high degrees of freedom for the pulse optimization but also produce high SARwc , which reduces the SAR accuracy in the VOP compression for low-SAR protocols, leading to a potential reduction in array performance. Smaller SAR overestimations can increase SAR accuracy, but lead to a high number of VOPs, which increases the computational cost for VOP evaluation and makes online SAR monitoring or pulse optimization challenging. Arrays with interleaved rings showed the best results in the study. KW - body imaging at UHF MRI KW - integrated transmit coil arrays KW - VOP compression Y1 - 2021 U6 - https://doi.org/10.1002/nbm.4515 SN - 0952-3480 (ISSN) SN - 1099-1492 (eISSN) VL - 34 IS - 7 PB - Wiley CY - Weinheim ER - TY - GEN A1 - Graf, Alain-Michel A1 - Steinhof, Rafael A1 - Lotz, Martin A1 - Tippkötter, Nils A1 - Kasper, Cornelia A1 - Beutel, Sascha A1 - Ulber, Roland T1 - Downstream-Processing mit Membranadsorbern zur Isolierung nativer Proteinfraktionen aus Kartoffelfruchtwasser T2 - Chemie Ingenieur Technik N2 - Bei der Stärkeproduktion entstehendes Kartoffelfruchtwasser besitzt mit 2 – 3 % einen hohen Anteil an ernährungsphysiologisch interessanten Proteinen. Die industrielle Gewinnung dieser Proteinfracht liefert jedoch lediglich ein minderwertiges, denaturiertes Produkt. Mit Hilfe der Membranadsorber-Technologie lassen sich aus Kartoffelfruchtwasser unter milden Reaktionsbedingungen native bioaktive Proteinfraktionen gewinnen. Geeignete Trennbedingungen wurden im Labormaßstab entwickelt und in den Technikumsmaßstab übertragen. An Anionenaustauscher-Membranadsorbern mit einer Membranfläche von 10 000 cm2 wurde eine Patatinhaltige Fraktion (44 kDa) mit Bindungskapazitäten von 0,37 mg/cm2 isoliert. Eine niedermolekulare Proteinfraktion mit Protease-Inhibitoren konnte durch Kationenaustauscher-Membranadsorber mit Bindungskapazitäten von 1,00 mg/cm2 gewonnen werden. Sie ist für verschiedenste Applikationen in der pharmazeutischen, kosmetischen und der Nahrungsmittelindustrie interessant z. B. für Appetitzügler oder muskelaufbauende Proteinpräparate. Der Aufreinigung der nativen Proteinfraktionen durch Ultra-/Diafiltration schließt sich die Konfektionierung durch Sprühtrocknung an. Die bioanalytische Charakterisierung der Produkte belegt die Reinheit und die enzymatische Aktivität sowie die Abreicherung von Störkomponenten wie Glykoalkaloide und Polyphenoloxidasen. Y1 - 2009 U6 - https://doi.org/10.1002/cite.200800139 VL - 81 IS - 3 SP - 267 EP - 274 PB - Wiley CY - Weinheim ER -