TY - JOUR A1 - Ribitsch, D. A1 - Heumann, S. A1 - Trotscha, E. A1 - Herrero Acero, E. A1 - Greimel, K. A1 - Leber, R. A1 - Birger-Gruenberger, R. A1 - Deller, S. A1 - Eiteljoerg, I. A1 - Remler, P. A1 - Weber, Th. A1 - Siegert, Petra A1 - Maurer, Karl-Heinz A1 - Donelli, I. A1 - Freddi, G. A1 - Schwab, H. A1 - Guebitz, G. M. T1 - Hydrolysis of polyethyleneterephthalate by p-nitrobenzylesterase from Bacillus subtilis JF - Biotechnology progress Y1 - 2011 SN - 1520-6033 (E-Journal); 8756-7938 (Print) VL - Vol. 27 IS - Iss. 4 SP - 951 EP - 960 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Bäcker, Matthias A1 - Schusser, Sebastian A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Multi-Parametererfassung mit siliziumbasiertem Sensorchip: Aus Drei mach Eins JF - GIT Labor-Fachzeitschrift Y1 - 2014 SN - 0016-3538 IS - 2 SP - 28 EP - 30 PB - Wiley ER - TY - JOUR A1 - Beging, Stefan A1 - Leinhos, Marcel A1 - Jablonski, Melanie A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Studying the spatially resolved immobilisation of enzymes on a capacitive field-effect structure by means of nano-spotting JF - Physica status solidi (a) Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431891 SN - 1862-6319 VL - 212 IS - 6 SP - 1353 EP - 1358 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Oberländer, Jan A1 - Bromm, Alexander A1 - Wendeler, Luisa A1 - Iken, Heiko A1 - Palomar Duran, Marlena A1 - Greeff, Anton A1 - Kirchner, Patrick A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Towards a biosensor to monitor the sterilisation efficiency of aseptic filling machines JF - Physica status solidi (a) N2 - Sterilisation processes are compulsory in medicine, pharmacy, and food industries to prevent infections of consumers and microbiological contaminations of products. Monitoring the sterilisation by conventional microbiological methods is time- and lab-consuming. To overcome this problem, in this work a novel biosensor has been proposed. The sensor enables a fast method to evaluate sterilisation processes. By means of thin-film technology the sensor's transducer structures in form of IDEs (interdigitated electrodes) have been fabricated on a silicon substrate. Physical characterisation of the developed sensor was done by AFM, SEM, and profilometry. Impedance analyses were conducted for the electrical characterisation. As microbiological layer spores of B. atrophaeus have been immobilised on the sensing structure; spores of this type are a well-known sterilisation test organism. Impedance measurements at a fixed frequency over time were performed to monitor the immobilisation process. A sterilisation process according to aseptic filling machines was applied to demonstrate the sensor functionality. After both, immobilisation and sterilisation, a change in impedance could successfully be detected. Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431900 SN - 1862-6319 VL - 212 IS - 6 SP - 1299 EP - 1305 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Reisert, Steffen A1 - Kramer, Friederike A1 - Begoyan, Vardges K. A1 - Buniatyan, Vahe V. A1 - Schöning, Michael Josef T1 - Multi-parameter sensing using high-k oxide of barium strontium titanate JF - Physica status solidi (a) N2 - High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors. In this work, a Si-based sensor chip containing Pt interdigitated electrodes covered with a thin BST layer (485 nm) has been developed for multi-parameter chemical sensing. The chip has been applied for the contactless measurement of the electrolyte conductivity, the detection of adsorbed charged macromolecules (positively charged polyelectrolytes of polyethylenimine) and the concentration of hydrogen peroxide (H2O2) vapor. The experimental results of functional testing of individual sensors are presented. The mechanism of the BST sensitivity to charged polyelectrolytes and H2O2 vapor has been proposed and discussed. Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431911 SN - 1862-6319 VL - 212 IS - 6 SP - 1259 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Jildeh, Zaid B. A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Pieper, Martin T1 - Simulating the electromagnetic‐thermal treatment of thin aluminium layers for adhesion improvement JF - Physica status solidi (a) N2 - A composite layer material used in packaging industry is made from joining layers of different materials using an adhesive. An important processing step in the production of aluminium-containing composites is the surface treatment and consequent coating of adhesive material on the aluminium surface. To increase adhesion strength between aluminium layer and the adhesive material, the foil is heat treated. For efficient heating, induction heating was considered as state-of-the-art treatment process. Due to the complexity of the heating process and the unpredictable nature of the heating source, the control of the process is not yet optimised. In this work, a finite element analysis of the process was established and various process parameters were studied. The process was simplified and modelled in 3D. The numerical model contains an air domain, an aluminium layer and a copper coil fitted with a magnetic field concentrating material. The effect of changing the speed of the aluminium foil (or rolling speed) was studied with the change of the coil current. Statistical analysis was used for generating a general control equation of coil current with changing rolling speed. Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431893 SN - 1862-6319 VL - Vol. 212 IS - 6 SP - 1234 EP - 1241 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Pilas, Johanna A1 - Iken, Heiko A1 - Selmer, Thorsten A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Development of a multi‐parameter sensor chip for the simultaneous detection of organic compounds in biogas processes JF - Physica status solidi (a) N2 - An enzyme-based multi-parameter biosensor is developed for monitoring the concentration of formate, d-lactate, and l-lactate in biological samples. The sensor is based on the specific dehydrogenation by an oxidized β-nicotinamide adenine dinucleotide (NAD+)-dependent dehydrogenase (formate dehydrogenase, d-lactic dehydrogenase, and l-lactic dehydrogenase, respectively) in combination with a diaphorase from Clostridium kluyveri (EC 1.8.1.4). The enzymes are immobilized on a platinum working electrode by cross-linking with glutaraldehyde (GA). The principle of the determination scheme in case of l-lactate is as follows: l-lactic dehydrogenase (l-LDH) converts l-lactate into pyruvate by reaction with NAD+. In the presence of hexacyanoferrate(III), the resulting reduced β-nicotinamide adenine dinucleotide (NADH) is then regenerated enzymatically by diaphorase. The electrochemical detection is based on the current generated by oxidation of hexacyanoferrate(II) at an applied potential of +0.3 V vs. an Ag/AgCl reference electrode. The biosensor will be electrochemically characterized in terms of linear working range and sensitivity. Additionally, the successful practical application of the sensor is demonstrated in an extract from maize silage. Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431894 SN - 1862-6319 VL - 212 IS - 6 SP - 1306 EP - 1312 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Breuer, Lars A1 - Raue, Markus A1 - Kirschbaum, M. A1 - Mang, Thomas A1 - Schöning, Michael Josef A1 - Thoelen, R. A1 - Wagner, Torsten T1 - Light-controllable polymeric material based on temperature-sensitive hydrogels with incorporated graphene oxide JF - Physica status solidi (a) N2 - Poly(N-isopropylacrylamide) (PNIPAAm) hydrogel films with incorporated graphene oxide (GO) were developed and tested as light-stimulated actuators. GO dispersions were synthesized via Hummers method and characterized toward their optical properties and photothermal energy conversion. The hydrogels were prepared by means of photopolymerization. In addition, the influence of GO within the hydrogel network on the lower critical solution temperature (LCST) was investigated by differential scanning calorimetry (DSC). The optical absorbance and the response to illumination were determined as a function of GO concentration for thin hydrogel films. A proof of principle for the stimulation with light was performed. Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431944 SN - 1862-6319 VL - 212 IS - 6 SP - 1368 EP - 1374 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Kharoubi, A. A1 - Schmidt-Trucksäß, A. A1 - Halle, M. A1 - Lanzl, I. T1 - Does internal longitudinal microstructure of retinal veins change with age in medically healthy persons? JF - Acta Ophthalmologica Y1 - 2009 SN - 1600-0420 (E-Journal); 1755-3768 (E-Journal); 0001-639X (Print); 1395-3907 (Print); 1755-375X (Print) VL - Vol. 87 IS - Suppl. S244 SP - 0 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Schiffels, Johannes A1 - Selmer, Thorsten T1 - A flexible toolbox to study protein-assisted metalloenzyme assembly in vitro JF - Biotechnology and Bioengineering Y1 - 2015 U6 - http://dx.doi.org/10.1002/bit.25658 SN - 1097-0290 VL - 112 IS - 11 SP - 2360 EP - 2372 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Voigt, Birgit A1 - Albrecht, Dirk A1 - Sievers, Susanne A1 - Becher, Dörte A1 - Bongaerts, Johannes A1 - Evers, Stefan A1 - Schweder, Thomas A1 - Maurer, Karl-Heinz A1 - Hecker, Michael T1 - High-resolution proteome maps of Bacillus licheniformis cells growing in minimal medium JF - Proteomics Y1 - 2015 U6 - http://dx.doi.org/10.1002/pmic.201400504 SN - 1615-9861 VL - 15 IS - 15 SP - 2629 EP - 2633 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Takenaga, Shoko A1 - Schneider, Benno A1 - Erbay, E. A1 - Biselli, Manfred A1 - Schnitzler, Thomas A1 - Schöning, Michael Josef A1 - Wagner, Torsten T1 - Fabrication of biocompatible lab-on-chip devices for biomedical applications by means of a 3D-printing process JF - Physica status solidi (a) N2 - A new microfluidic assembly method for semiconductor-based biosensors using 3D-printing technologies was proposed for a rapid and cost-efficient design of new sensor systems. The microfluidic unit is designed and printed by a 3D-printer in just a few hours and assembled on a light-addressable potentiometric sensor (LAPS) chip using a photo resin. The cell growth curves obtained from culturing cells within microfluidics-based LAPS systems were compared with cell growth curves in cell culture flasks to examine biocompatibility of the 3D-printed chips. Furthermore, an optimal cell culturing within microfluidics-based LAPS chips was achieved by adjusting the fetal calf serum concentrations of the cell culture medium, an important factor for the cell proliferation. Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201532053 SN - 1862-6319 VL - 212 IS - 6 SP - 1347 EP - 1352 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Molinnus, Denise A1 - Bäcker, Matthias A1 - Iken, Heiko A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Concept for a biomolecular logic chip with an integrated sensor and actuator function JF - Physica status solidi (a) N2 - A concept for a new generation of an integrated multi-functional biosensor/actuator system is developed, which is based on biomolecular logic principles. Such a system is expected to be able to detect multiple biochemical input signals simultaneously and in real-time and convert them into electrical output signals with logical operations such as OR, AND, etc. The system can be designed as a closed-loop drug release device triggered by an enzyme logic gate, while the release of the drug induced by the actuator at the required dosage and timing will be controlled by an additional drug sensor. Thus, the system could help to make an accurate and specific diagnosis. The presented concept is exemplarily demonstrated by using an enzyme logic gate based on a glucose/glucose oxidase system, a temperature-responsive hydrogel mimicking the actuator function and an insulin (drug) sensor. In this work, the results of functional testing of individual amperometric glucose and insulin sensors as well as an impedimetric sensor for the detection of the hydrogel swelling/shrinking are presented. Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431913 SN - 1862-6319 VL - 212 IS - 6 SP - 1382 EP - 1388 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Delle, Lotta E. A1 - Huck, Christina A1 - Bäcker, Matthias A1 - Müller, Frank A1 - Grandthyll, Samuel A1 - Jacobs, Karin A1 - Lilischkis, Rainer A1 - Vu, Xuan T. A1 - Schöning, Michael Josef A1 - Wagner, Patrick A1 - Thoelen, Roland A1 - Weil, Maryam A1 - Ingebrandt, Sven T1 - Impedimetric immunosensor for the detection of histamine based on reduced graphene oxide JF - Physica status solidi (a) Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431863 SN - 1862-6319 VL - 212 IS - 6 SP - 1327 EP - 1334 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Kürten, Sylvia A1 - Mottaghy, Darius A1 - Ziegler, Martin T1 - Besonderheiten bei der Planung und Berechnung von oberflächennahen thermo-aktiven Bauteilen JF - Geotechnik Y1 - 2015 U6 - http://dx.doi.org/10.1002/gete.201500002 SN - 2190-6653 VL - 38 IS - 2 SP - 107 EP - 119 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Butenweg, Christoph A1 - Gellert, Christoph T1 - Integrale Gebäudeplanung am Beispiel eines Geschossbaus in Ziegelmauerwerk JF - Mauerwerk : European journal of masonry N2 - Moderne Mauerwerksbauten müssen nach heutigen Anforderungen architektonisch, statisch, energetisch sowie schall- und brandschutztechnisch optimal ausgelegt sein. Aufgrund der Komplexität und engen Verzahnung der einzelnen Anforderungen ist eine integrale Gebäudeplanung zur Erzielung einer qualitativ hochwertigen Bauwerkslösung unbedingt notwendig. Diese erfordert von den Fachplanern vertieftes Spezialwissen in den verschiedenen Bereichen, um insbesondere die Schnittstellen und Bauwerksdetails korrekt zu planen und auszuführen. Der Beitrag stellt die integrale Gebäudeplanung am Beispiel eines Geschossbaus in Ziegelbauweise mit Lösungen für wesentliche Detailpunkte vor Y1 - 2012 U6 - http://dx.doi.org/10.1002/dama.201200550 SN - 1437-1022 (E-Journal); 1432-3427 (Print) VL - Volume 16 IS - 5 SP - 247 EP - 254 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Butenweg, Christoph A1 - Gellert, Christoph T1 - Nichtlinearer Nachweis von Mauerwerksbauten JF - Mauerwerk : European journal of masonry Y1 - 2013 U6 - http://dx.doi.org/10.1002/dama.201300575 SN - 1437-1022 (E-Journal); 1432-3427 (Print) VL - Volume 17 IS - Issue 3 SP - 166 EP - 171 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Taddei, Francesca A1 - Butenweg, Christoph A1 - Klinkel, S. T1 - Parametric investigation of the soil-structure interaction effects on the dynamic behaviour of a shallow foundation supported wind turbine considering a layered soil JF - Wind energy : an international journal for progress and applications in wind power conversion technology Y1 - 2015 U6 - http://dx.doi.org/10.1002/we.1703 SN - 1099-1824 (E-Journal); 1095-4244 (Print) VL - Volume 18 IS - Issue 3 SP - 399 EP - 417 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Butenweg, Christoph A1 - Fehling, Ekkehard T1 - Hintergrund für die vereinfachten Regeln bei Mauerwerksgebäuden im Erdbebenfall JF - Mauerwerk : European journal of masonry N2 - Bei der Ausarbeitung des nationalen Anwendungsdokumentes zur DIN EN 1998-1 waren die in der ENV-Fassung enthaltenen vereinfachten Regeln im Lichte aktueller Forschungsergebnisse zu überprüfen und zu überarbeiten. Die gleiche Aufgabe stellte sich auch für die Neufassung der DIN 4149. In beiden Fällen sind neben konstruktiven Regeln für die Art und Anordnung der zur Gebäudeaussteifung heranzuziehenden Wände im Grundriss Tabellen enthalten, die unter bestimmten Bedingungen den Entfall eines rechnerischen Nachweises der Tragwände im Erdbebenfall ermöglichen. Dies ist für Schwachbebengebiete, wie sie in Deutschland und anderen Ländern Mitteleuropas anzutreffen sind, sinnvoll, um unnötigen Rechenaufwand sowie Probleme mit der Führbarkeit von Nachweisen so weit wie möglich auszuschalten. Im vorliegenden Beitrag werden die Hintergründe der vereinfachten Regeln diskutiert und die Ergebnisse der Anwendung mit verschiedenen Rechenverfahren verglichen und bewertet. Y1 - 2012 U6 - http://dx.doi.org/10.1002/dama.201200537 SN - 1437-1022 (E-Journal); 1432-3427 (Print) VL - Volume 16 IS - Issue 3 SP - 127 EP - 137 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Laumann, Jörg A1 - Mainz, Stefan T1 - Direkte Ermittlung der erforderlichen Einspanntiefe von I‑förmigen Stahlquerschnitten in Betonkonstruktionen N2 - Für die Ermittlung der erforderlichen Einspanntiefe von eingespannten Stahlquerschnitten in Betonkonstruktionen existieren verschiedene Bemessungsmodelle. Diese basieren vorwiegend auf Grundlage nationaler Normen wie z. B. DIN 18800 [1] und DIN 1045 [2], die durch die europäische Normung ersetzt wurden. Aus diesem Grund wird in diesem Aufsatz ein Berechnungsmodell für die erforderliche Einspanntiefe von eingespannten Stahlquerschnitten in Betonkonstruktionen auf Grundlage des Eurocodes vorgestellt. Das Grundgerüst für dieses Berechnungsmodell bildet das Verfahren nach Kindmann und Laumann, welches in [3] behandelt wurde. Gleichzeitig werden neue Formeln zur direkten Ermittlung der Mindesteinspanntiefe vorgestellt. Behandelt werden gewalzte I-Profile für einachsige Biegung um die starke Achse (y-y) mit Drucknormalkraft. Y1 - 2012 U6 - http://dx.doi.org/10.1002/stab.201201620 SN - 1437-1049 VL - 81 IS - 11 SP - 850 EP - 860 PB - Wiley CY - Weinheim ER -