TY - JOUR A1 - Esch, Thomas A1 - Salber, W. A1 - Kemper, Hans A1 - Staay, F. van der T1 - Der elektromechanische Ventiltrieb - Systembaustein für zukünftige Antriebskonzepte, Teil 2. JF - Motortechnische Zeitschrift (MTZ). Y1 - 2001 U6 - https://doi.org/10.1007/bf03227081 SN - 0024-8525 VL - 62 IS - 1 SP - 44 EP - 55 PB - Springer Nature CY - Basel ER - TY - JOUR A1 - Esch, Thomas A1 - Salber, W. A1 - Kemper, Hans A1 - Staay, F. van der T1 - Der elektromechanische Ventiltrieb - Systembaustein für zukünftige Antriebskonzepte, Teil 1. JF - Motortechnische Zeitschrift (MTZ). Y1 - 2000 U6 - https://doi.org/10.1007/bf03227081 SN - 0024-8525 VL - 61 IS - 12 SP - 826 EP - 836 PB - Springer Nature CY - Basel ER - TY - JOUR A1 - Esch, Thomas A1 - Funke, Harald A1 - Roosen, Peter A1 - Jarolimek, Ulrich T1 - Biogene Automobilkraftstoffe in der allgemeinen Luftfahrt JF - Motortechnische Zeitschrift (MTZ). Y1 - 2011 SN - 0024-8525 U6 - https://doi.org/10.1365/s35146-011-0013-7 VL - 72 IS - 1 SP - 54 EP - 59 PB - Springer Nature CY - Basel ER - TY - JOUR A1 - Esch, Thomas T1 - Trends in der Nutzfahrzeugantriebstechnik JF - Motortechnische Zeitschrift (MTZ) Y1 - 2010 SN - 0024-8525 U6 - https://doi.org/10.1007/bf03225608 VL - 71 IS - 10 SP - 652 EP - 658 PB - Springer Nature CY - Basel ER - TY - JOUR A1 - Atlas, Glen A1 - Brealey, David A1 - Dhar, Sunil A1 - Dikta, Gerhard A1 - Singer, Meryvn T1 - Additional hemodynamic measurements with an esophageal Doppler monitor: a preliminary report of compliance, force, kinetic energy, and afterload in the clinical setting JF - Journal of clinical monitoring and computing N2 - The esophageal Doppler monitor (EDM) is a minimally-invasive hemodynamic device which evaluates both cardiac output (CO), and fluid status, by estimating stroke volume (SV) and calculating heart rate (HR). The measurement of these parameters is based upon a continuous and accurate approximation of distal thoracic aortic blood flow. Furthermore, the peak velocity (PV) and mean acceleration (MA), of aortic blood flow at this anatomic location, are also determined by the EDM. The purpose of this preliminary report is to examine additional clinical hemodynamic calculations of: compliance (C), kinetic energy (KE), force (F), and afterload (TSVRi). These data were derived using both velocity-based measurements, provided by the EDM, as well as other contemporaneous physiologic parameters. Data were obtained from anesthetized patients undergoing surgery or who were in a critical care unit. A graphical inspection of these measurements is presented and discussed with respect to each patient’s clinical situation. When normalized to each of their initial values, F and KE both consistently demonstrated more discriminative power than either PV or MA. The EDM offers additional applications for hemodynamic monitoring. Further research regarding the accuracy, utility, and limitations of these parameters is therefore indicated. KW - Acceleration KW - Velocity KW - Kinetic energy KW - Force KW - Compliance KW - Afterload KW - Contractility KW - Volume status KW - Esophageal Doppler monitor Y1 - 2012 SN - 1573-2614 U6 - https://doi.org/10.1007/s10877-012-9386-5 IS - 26 SP - 473 EP - 482 PB - Springer Nature CY - London ER - TY - JOUR A1 - Kurz, R. A1 - Linder, Peter A1 - Trzewik, Jürgen A1 - Rüffer, M. A1 - Artmann, Gerhard A1 - Digel, Ilya A1 - Rothermel, A. A1 - Robitzki, A. A1 - Temiz Artmann, Aysegül T1 - Contractile tension and beating rates of self-exciting monolayers and 3D-tissue constructs of neonatal rat cardiomyocytes JF - Medical and Biological Engineering and Computing N2 - The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocytes. Cells were grown either within flexible, circular collagen gels or as monolayer on top of respective 1-mum thin silicone membranes. Membrane and cells were bulged outwards by air pressure. This biaxial strain distribution is rather similar the beating, blood-filled heart. The setup allowed presetting the mechanical residual stress level externally by adjusting the centre deflection, thus, mimicking hypertension in vitro. Tension was measured as oscillating differential pressure change between chamber and environment. A 0.5-mm thick collagen-cardiac myocyte tissue construct induced after 2 days of culturing (initial cell density 2 x 10(4) cells/ml), a mechanical tension of 1.62 +/- 0.17 microN/mm(2). Mechanical load is an important growth regulator in the developing heart, and the orientation and alignment of cardiomyocytes is stress sensitive. Therefore, it was necessary to develop the CellDrum technology with its biaxial stress-strain distribution and defined mechanical boundary conditions. Cells were exposed to strain in two directions, radially and circumferentially, which is similar to biaxial loading in real heart tissues. Thus, from a biomechanical point of view, the system is preferable to previous setups based on uniaxial stretching. Y1 - 2010 U6 - https://doi.org/10.1007/s11517-009-0552-y SN - 1741-0444 VL - 48 IS - 1 SP - 59 EP - 65 PB - Springer Nature CY - Cham ER - TY - JOUR A1 - Srivastava, A. A1 - Lahiri, S. A1 - Maiti, M. A1 - Knolle, F. A1 - Hoyler, Friedrich A1 - Scherer, Ulrich W. A1 - Schnug, E. W. T1 - Study of naturally occurring radioactive material (NORM) in top soil of Punjab State from the North Western part of India JF - Journal of Radioanalytical and Nuclear Chemistry Y1 - 2014 U6 - https://doi.org/0.1007/s10967-014-3450-1 SN - 1588-2780 (E-Journal); 0022-4081 (Print); 0134-0719 (Print); 0236-5731 (Print); 1417-2097 (Print) VL - 2014 IS - 302 SP - 1049 EP - 1052 PB - Springer Nature CY - Basel ER - TY - JOUR A1 - Ratke, Lorenz A1 - Milow, Barbara A1 - Lisinski, Susanne A1 - Hoepfner, Sandra T1 - On an effect of fine ceramic particles on the structure of aerogels JF - Microgravity science and technology Y1 - 2014 U6 - https://doi.org/10.1007/s12217-014-9380-2 SN - 0938-0108 ; 1875-0494 VL - 26 SP - 103 EP - 110 PB - Springer Nature CY - Heidelberg ER - TY - JOUR A1 - Leandro, J. A1 - Bung, Daniel Bernhard A1 - Carvalho, R. T1 - Measuring void fraction and velocity fields of a stepped spillway for skimming flow using non-intrusive methods JF - Experiments in fluids Y1 - 2014 U6 - https://doi.org/10.1007/s00348-014-1732-6 SN - 0723-4864 (Print) ; 1432-1114 (Online) IS - 55 SP - Art. 1732 PB - Springer Nature CY - Heidelberg ER - TY - JOUR A1 - Eilmann, Britta A1 - Dobbertin, Matthias A1 - Rigling, Andreas T1 - Growth response of Scots pine with different crown transparency status to drought release JF - Annals of Forest Science Y1 - 2013 U6 - https://doi.org/10.1007/s13595-013-0310-z SN - 1286-4560 (Print) SN - 1297-966X (Online) VL - 70 IS - 7 SP - 685 EP - 693 PB - Springer CY - Cham ER -