TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael T1 - The restricted influence of kinematic hardening on shakedown loads N2 - Structural design analyses are conducted with the aim of verifying the exclusion of ratcheting. To this end it is important to make a clear distinction between the shakedown range and the ratcheting range. In cyclic plasticity more sophisticated hardening models have been suggested in order to model the strain evolution observed in ratcheting experiments. The hardening models used in shakedown analysis are comparatively simple. It is shown that shakedown analysis can make quite stable predictions of admissible load ranges despite the simplicity of the underlying hardening models. A linear and a nonlinear kinematic hardening model of two-surface plasticity are compared in material shakedown analysis. Both give identical or similar shakedown ranges. Structural shakedown analyses show that the loading may have a more pronounced effect than the hardening model. KW - Biomedizinische Technik KW - Einspielen KW - Shakedown KW - Ratcheting KW - Bruchmechanik KW - shakedown KW - material shakedown KW - linear kinematic hardening KW - nonlinear kinematic hardening KW - ratchetting Y1 - 2002 ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael A1 - Hicken, E. F. T1 - LISA - ein europäisches Projekt zur FEM-basierten Traglast- und Einspielanalyse T1 - LISA - a European project for FEM-based limit and shakedown analysis N2 - Traglast- und Einspielanalysen sind vereinfachte doch exakte Verfahren der Plastizität, die neben ausreichender Verformbarkeit keine einschränkenden Voraussetzungen beinhalten. Die Vereinfachungen betreffen die Beschaffung der Daten und Modelle für Details der Lastgeschichte und des Stoffverhaltens. Anders als die klassische Behandlung nichtlinearer Probleme der Strukturmechanik führt die Methode auf Optimierungsprobleme. Diese sind bei realistischen FEM-Modellen sehr groß. Das hat die industrielle Anwendung der Traglast- und Einspielanalysen stark verzögert. Diese Situation wird durch das Brite-EuRam Projekt LISA grundlegend geändert. In LISA entsteht auf der Basis des industriellen FEM-Programms PERMAS ein Verfahren zur direkten Berechnung der Tragfähigkeit duktiler Strukturen. Damit kann der Betriebsbereich von Komponenten und Bauwerken auf den plastischen Bereich erweitert werden, ohne den Aufwand gegenüber elastischen Analysen wesentlich zu erhöhen. Die beachtlichen Rechenzeitgewinne erlauben Parameterstudien und die Berechnung von Interaktionsdiagrammen, die einen schnellen Überblick über mögliche Betriebsbereiche vermitteln. Es zeigt sich, daß abhängig von der Komponente und ihren Belastungen teilweise entscheidende Sicherheitsgewinne zur Erweiterung der Betriebsbereiche erzielt werden können. Das Vorgehen erfordert vom Anwender oft ein gewisses Umdenken. Es werden keine Spannungen berechnet, um damit Sicherheit und Lebensdauer zu interpretieren. Statt dessen berechnet man direkt die gesuchte Sicherheit. Der Post-Prozessor wird nur noch zur Modell- und Rechenkontrolle benötigt. Das Vorgehen ist ähnlich der Stabilitätsanalyse (Knicken, Beulen). Durch namhafte industrielle Projektpartner werden Validierung und die Anwendbarkeit auf eine breite Palette technischer Probleme garantiert. Die ebenfalls in LISA entwickelten Zuverlässigkeitsanalysen sind nichlinear erst auf der Basis direkter Verfahren effektiv möglich. Ohne Traglast- und Einspielanalyse ist plastische Strukturoptimierung auch heute kaum durchführbar. Auf die vorgesehenen Erweiterungen der Werkstoffmodellierung für nichtlineare Verfestigung und für Schädigung konnte hier nicht eingegangen werden. Es herrscht ein deutlicher Mangel an Experimenten zum Nachweis der Grenzen zwischen elastischem Einspielen und dem Versagen durch LCF oder durch Ratchetting. KW - Einspielen KW - Traglast KW - Finite-Elemente-Methode KW - LISA KW - limit analysis KW - shakedown analysis Y1 - 1999 ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael A1 - Reinders, H. A1 - Schubert, F. T1 - Einspielen und Ratchetting bei Zug- und Torsionsbelastung: Analyse und Experimente T1 - Shakedown and ratchetting under tension-torsion loadings: analysis and experiments N2 - Traglast- und Einspielanalysen sind vereinfachte doch exakte Verfahren der klassischen Plastizitätstheorie, die neben ausreichender Verformbarkeit keine einschränkenden Voraussetzungen beinhalten. Die Vereinfachungen betreffen die Beschaffung der Daten und Modelle für Details der Lastgeschichte und des Stoffverhaltens. Eine FEM-basierte Traglast- und Einspielanalyse für ideal plastisches Material wurde auf ein kinematisch verfestigendes Materialgesetz erweitert und in das Finite Element Programm PERMAS implementiert. In einem einfachen Zug-Torsionsexperiment wurde eine Hohlprobe mit konstanter Torsion und zyklischer Zugbelastung beansprucht, um die neue Implementierung zu verifizieren. Es konnte gezeigt werden, dass die Einspielanalyse gut mit den experimentellen Ergebnissen übereinstimmt. Bei Verfestigung lassen sich wesentlich größere Sicherheiten nachweisen. Dieses Potential bedarf weiterer experimenteller Absicherung. Parallel dazu ist die Eisnpieltheorie auf fortschrittliche Verfestigungsansätze zu erweitern. KW - Zug-Druck-Beanspruchung KW - Einspielen KW - Ratcheting KW - Torsion KW - Zug-Druck-Belastung KW - Torsionsbelastung KW - shakedown KW - ratchetting KW - tension–torsion loading Y1 - 2001 ER - TY - CHAP A1 - Staat, Manfred A1 - Szelinski, E. A1 - Heitzer, Michael T1 - Kollapsanalyse von längsfehlerbehafteten Rohren und Behältern T1 - Collapse analysis of longitudinally flawed pipes and vessels N2 - Es werden verbesserte Kollapsanalysen von dickwandigen, mit axialen Oberflächenfehlern behafteten Rohren und Behältern vorgeschlagen. KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohr KW - Rohrbruch KW - Fehlerstellen KW - pipes KW - vessels KW - load limit KW - burst tests KW - burst pressure KW - flaw Y1 - 2001 ER - TY - CHAP A1 - Surtees, A. J. A1 - Gillespie, A. A1 - Kern, Alexander A1 - Rousseau, A. T1 - DEVELOPMENT OF A RISK ASSESSMENT CALCULATOR BASED ON A SIMPLIFIED FORM OF THE IEC 62305-2 STANDARD ON LIGHTNING PROTECTION N2 - Neue Blitzschutznorm IEC 62305. Entwicklung einer einfachen Software zur Risikoabwägung N2 - IEC Technical Committee 81 is currently creating the new IEC 62305 series of standards on Lightning Protection. Working Group 9 is responsible for Part 2 of this series, which deals with the assessment and management of risk its CDV (Committee Draft for Voting) stage and has been circulated to National Committees for comment. The paper details the development of the Simplified IEC Risk Assessment Calculator software tool as described in Informative Annex J of IEC62305-2 Ed.1/CDV 2. This tool is intended as a simplified implementation of the more rigorous treatment of risk management found in the written document. It is designed to be relatively intuitive for users who wish to obtain an initial assessment of risk sensitivity, but should not be considered a substitute to a full understanding of the methods provided in the standard when dealing with more complicated structures or those where greater risks to personal or system operation are involved. KW - Risiko KW - Risikoabwägung KW - Blitzrisiko KW - Blitzschutz KW - Risk KW - Risk Management KW - Risk Assessment KW - Lightning Risk KW - Lightning Protection Y1 - 2004 ER - TY - CHAP A1 - Zischank, Wolfgang J. A1 - Heidler, Fridolin A1 - Kern, Alexander A1 - Metwally, I. A. A1 - Wiesinger, J. A1 - Seevers, M. T1 - Laboratory simulation of direct lightning strokes to a modelled building - measurement of magnetic fields and induced voltages N2 - In IEC 61312-2 equations for the assessment of the magnetic fields inside structures due to a direct lightning strike are given. These equations are based on computer simulations for shields consisting of a single-layer steel grid of a given mesh width. Real constructions, however, contain at least two layers of reinforcement steel grids. The objective of this study was to experimentally determine the additional shielding effectiveness of a second reinforcement layer compared to a single-layer grid. To this end, simulated structures were set up in the high current laboratory. The structures consisted of cubic cages of 2 m side length with one or with two reinforcement grids, respectively. The structures were exposed to direct lightning currents representing the variety of anticipated lightning current waveforms. The magnetic fields and their derivatives at several positions inside the structure as well as the voltage between “floor” and “roof” in the center were determined for different current injection points. From these data the improvement of the shielding caused by a second reinforcement layer is derived. KW - Direkter Blitzschlag KW - Elektromagnetischer Schutzschild KW - Magnetische Felder KW - Induzierte Spannungen KW - Stahlbetonkonstruktion KW - Lightning KW - electromagnetic shielding KW - magnetic field KW - reinforced concrete KW - induced voltage Y1 - 2002 ER - TY - CHAP A1 - Zischank, Wolfgang J. A1 - Heidler, Fridolin A1 - Wiesinger, J. A1 - Stimper, K. A1 - Kern, Alexander A1 - Seevers, M. T1 - Magnetic Fields and Induced Voltages inside LPZ 1 Measured at a 1:6 Scale Model Building N2 - Laborexperimente zu Blitzschutzzonen in Stahlbetongebäuden anhand eines Modells im Maßstab 1:6 N2 - For the application of the concept of Lightning Protection Zones (LPZ), the knowledge of the magnetic fields and induced voltages inside a structure is necessary. Laboratory experiments have been conducted at a downscaled model of a building (scale factor 1:6) to determine these electromagnetic quantities in case of a direct strike to the structure. The model (3 m x 2 m x 2 m) represented a small industrial building using the reinforcement of the concrete as electromagnetic shield. The magnetic fields and magnetic field derivatives were measured at several location inside the scaled model. Further, the voltages induced on three typical cable routes inside the model was determined. The influence of the lightning current waveshape, point-of-strike, bonding of the cable routes, and bridging of an expansion joint in the middle of the building on these quantities was studied. KW - Blitzschlag KW - Elektromagnetischer Schutzschild KW - Stahlbeton KW - Maßstabsgetreues Modell KW - Lightning KW - electromagnetic shielding KW - reinforced concrete KW - scaled model Y1 - 2004 ER - TY - CHAP A1 - Zischank, Wolfgang J. A1 - Kern, Alexander A1 - Frentzel, Ralf A1 - Heidler, Fridolin A1 - Seevers, M. T1 - Assessment of the lightning transient coupling to control cables interconnecting structures in large industrial facilities and power plants N2 - Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I&C-cables. KW - Blitzschutz KW - Elektromagnetische Kopplung KW - Überspannung KW - Kraftwerke KW - Industrieanlagen KW - Lightning KW - current distribution KW - electromagnetic coupling KW - overvoltages Y1 - 2000 ER -