TY - JOUR A1 - Döring, Bernd A1 - Reger, Vitali A1 - Kuhnhenne, Markus A1 - Feldmann, Markus A1 - Kesti, Jyrki A1 - Lawson, Mark A1 - Botti, Andrea T1 - Steel solutions for enabling zero-energy buildings JF - Steel Construction - Design and Research Y1 - 2015 U6 - https://doi.org/10.1002/stco.201510029 SN - 1867-0539 N1 - The 13th Nordic Steel Construction Conference, Tampere, 2015 (NSCC-2015) VL - 8 IS - 3 SP - 194 EP - 200 PB - Ernst & Sohn CY - Berlin ER - TY - JOUR A1 - Fellin, Wolfgang A1 - King, Julian A1 - Kirsch, Ansgar A1 - Oberguggenberger, Michael T1 - Uncertainty modelling and sensitivity analysis of tunnel face stability JF - Structural safety N2 - This paper proposes an approach to the choice and evaluation of engineering models with the aid of a typical application in geotechnics. An important issue in the construction of shallow tunnels, especially in weak ground conditions, is the tunnel face stability. Various theoretical and numerical models for predicting the necessary support pressure have been put forth in the literature. In this paper, we combine laboratory experiments performed at the University of Innsbruck with current methods of uncertainty and sensitivity analysis for assessing adequacy, predictive power and robustness of the models. The major issues are the handling of the twofold uncertainty of test results and of model predictions as well as the decision about what are the influential input parameters. Y1 - 2010 U6 - https://doi.org/10.1016/j.strusafe.2010.06.001 SN - 0167-4730 VL - 32 IS - 6 SP - 402 EP - 410 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kirsch, Ansgar T1 - Experimental investigation of the face stability of shallow tunnels in sand JF - Acta Geotechnica N2 - Various models have been proposed for the prediction of the necessary support pressure at the face of a shallow tunnel. To assess their quality, the collapse of a tunnel face was modelled with small-scale model tests at single gravity. The development of the failure mechanism and the support force at the face in dry sand were investigated. The observed displacement patterns show a negligible influence of overburden on the extent and evolution of the failure zone. The latter is significantly influenced, though, by the initial density of the sand: in dense sand a chimney-wedge-type collapse mechanism developed, which propagated towards the soil surface. Initially, loose sand did not show any discrete collapse mechanism. The necessary support force was neither influenced by the overburden nor the initial density. A comparison with quantitative predictions by several theoretical models showed that the measured necessary support pressure is overestimated by most of the models. Those by Vermeer/Ruse and Léca/Dormieux showed the best agreement to the measurements. Y1 - 2010 U6 - https://doi.org/10.1007/s11440-010-0110-7 SN - 1861-1125 VL - 5 IS - 1 SP - 43 EP - 62 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kolymbas, Dimitrios A1 - Fellin, W. A1 - Kirsch, Ansgar T1 - Squeezing due to stress relaxation in foliated rock JF - International journal for numerical and analytical methods in geomechanics Y1 - 2006 U6 - https://doi.org/10.1002/nag.530 SN - 1096-9853 (E-Journal); 0363-9061 (Print) VL - Vol. 30 IS - Iss. 13 SP - 1357 EP - 1367 ER - TY - JOUR A1 - Bayon, Arnau A1 - Valero, Daniel A1 - Garcia-Bartual, Rafael A1 - Vallés-Morán, Francisco José A1 - López-Jiménez, P. Amparo T1 - Performance assessment of OpenFOAM and FLOW-3D in the numerical modeling of a low Reynolds number hydraulic jump JF - Environmental Modelling & Software N2 - A comparative performance analysis of the CFD platforms OpenFOAM and FLOW-3D is presented, focusing on a 3D swirling turbulent flow: a steady hydraulic jump at low Reynolds number. Turbulence is treated using RANS approach RNG k-ε. A Volume Of Fluid (VOF) method is used to track the air–water interface, consequently aeration is modeled using an Eulerian–Eulerian approach. Structured meshes of cubic elements are used to discretize the channel geometry. The numerical model accuracy is assessed comparing representative hydraulic jump variables (sequent depth ratio, roller length, mean velocity profiles, velocity decay or free surface profile) to experimental data. The model results are also compared to previous studies to broaden the result validation. Both codes reproduced the phenomenon under study concurring with experimental data, although special care must be taken when swirling flows occur. Both models can be used to reproduce the hydraulic performance of energy dissipation structures at low Reynolds numbers. Y1 - 2016 SN - 1364-8152 U6 - https://doi.org/10.1016/j.envsoft.2016.02.018 VL - 80 SP - 322 EP - 335 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Zhang, G. A1 - Valero, Daniel A1 - Bung, Daniel Bernhard A1 - Chanson, H. T1 - On the estimation of free-surface turbulence using ultrasonic sensors JF - Flow Measurement and Instrumentation N2 - Accurate determination of free-surface dynamics has attracted much research attention during the past decade and has important applications in many environmental and water related areas. In this study, the free-surface dynamics in several turbulent flows commonly found in nature were investigated using a synchronised setup consisting of an ultrasonic sensor and a high-speed video camera. Basic sensor capabilities were examined in dry conditions to allow for a better characterisation of the present sensor model. The ultrasonic sensor was found to adequately reproduce free-surface dynamics up to the second order, especially in two-dimensional scenarios with the most energetic modes in the low frequency range. The sensor frequency response was satisfactory in the sub-20 Hz band, and its signal quality may be further improved by low-pass filtering prior to digitisation. The application of the USS to characterise entrapped air in high-velocity flows is also discussed. Y1 - 2018 U6 - https://doi.org/10.1016/j.flowmeasinst.2018.02.009 SN - 0955-5986 VL - 60 SP - 171 EP - 184 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bung, Daniel Bernhard A1 - Erpicum, Sébastien A1 - Tullis, Blanke P. T1 - Advances in hydraulic structures engineering JF - Journal of Hydraulic Engineering Y1 - 2020 U6 - https://doi.org/10.1061/(ASCE)HY.1943-7900.0001851 SN - 0733-9429 (Druckausgabe) SN - 1943-7900 (Online-Ausgabe) VL - 147 IS - 1 PB - ASCE CY - Reston, Va. ER - TY - JOUR A1 - Valero, Daniel A1 - Chanson, Hubert A1 - Bung, Daniel Bernhard T1 - Robust estimators for turbulence properties assessment Y1 - 2019 SP - 1 EP - 24 ER - TY - JOUR A1 - Hagenkamp, Markus A1 - Blanke, Tobias A1 - Döring, Bernd T1 - Thermoelectric building temperature control: a potential assessment JF - International Journal of Energy and Environmental Engineering N2 - This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants. Y1 - 2021 U6 - https://doi.org/10.1007/s40095-021-00424-x N1 - Corresponding author: Markus Hagenkamp VL - 13 SP - 241 EP - 254 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kerpen, Nils B. A1 - Bung, Daniel Bernhard A1 - Valero, Daniel A1 - Schlurmann, Torsten T1 - Energy dissipation within the wave run-up at stepped revetments JF - Journal of Ocean University of China Y1 - 2017 U6 - https://doi.org/10.1007/s11802-017-3355-z SN - 1993-5021 VL - 16 IS - 4 SP - 649 EP - 654 PB - Springer CY - Berlin ER -