TY - JOUR A1 - Doll, Theodor A1 - Wagner, Torsten A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Engineering of functional interfaces / Theodor Doll ; Torsten Wagner ; Patrick Wagner ; Michael J. Schöning (eds.) JF - Physica status solidi (a) Y1 - 2016 U6 - https://doi.org/10.1002/pssa.201670641 SN - 1862-6319 VL - 213 IS - 6 SP - 1393 EP - 1394 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Ghosch, S. A1 - Baier, M. A1 - Schütz, J. A1 - Schneider, Felix A1 - Scherer, Ulrich W. T1 - Analysis of electronic autoradiographs by mathematical post-processing JF - Radiation Effects and Defects in Solids: Incorporating plasma science and plasma technology N2 - Autoradiography is a well-established method of nuclear imaging. When different radionuclides are present simultaneously, additional processing is needed to distinguish distributions of radionuclides. In this work, a method is presented where aluminium absorbers of different thickness are used to produce images with different cut-off energies. By subtracting images pixel-by-pixel one can generate images representing certain ranges of β-particle energies. The method is applied to the measurement of irradiated reactor graphite samples containing several radionuclides to determine the spatial distribution of these radionuclides within pre-defined energy windows. The process was repeated under fixed parameters after thermal treatment of the samples. The greyscale images of the distribution after treatment were subtracted from the corresponding pre-treatment images. Significant changes in the intensity and distribution of radionuclides could be observed in some samples. Due to the thermal treatment parameters the most significant differences were observed in the ³H and ¹⁴C inventory and distribution. Y1 - 2016 U6 - https://doi.org/10.1080/10420150.2016.1155587 SN - 1029-4953 VL - 171 IS - 1-2 SP - 161 EP - 172 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Seynnes, O. R. A1 - Bojsen-Moller, J. A1 - Albracht, Kirsten A1 - Arndt, A. A1 - Cronin, N. J. A1 - Finni, T. A1 - Magnusson, S. P. T1 - Ultrasound-based testing of tendon mechanical properties: a critical evaluation JF - Journal of Applied Physiology Y1 - 2015 U6 - https://doi.org/10.1152/japplphysiol.00849.2014 SN - 8750-7587 VL - 118 IS - 2 SP - 133 EP - 141 ER - TY - JOUR A1 - Albracht, Kirsten A1 - Arampatzis, Adamantios T1 - Exercise-induced changes in triceps surae tendon stiffness and muscle strength affect running economy in humans JF - European Journal of Applied Physiology Y1 - 2013 U6 - https://doi.org/10.1007/s00421-012-2585-4 SN - 1439-6327 VL - 113 IS - 6 SP - 1605 EP - 1615 PB - Springer CY - Berlin ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Peper, Andreas A1 - Bierbaum, Stefanie A1 - Albracht, Kirsten T1 - Plasticity of human Achilles tendon mechanical and morphological properties in response to cyclic strain JF - Journal of Biomechanics N2 - The purpose of the current study in combination with our previous published data (Arampatzis et al., 2007) was to examine the effects of a controlled modulation of strain magnitude and strain frequency applied to the Achilles tendon on the plasticity of tendon mechanical and morphological properties. Eleven male adults (23.9±2.2 yr) participated in the study. The participants exercised one leg at low magnitude tendon strain (2.97±0.47%), and the other leg at high tendon strain magnitude (4.72±1.08%) of similar frequency (0.5 Hz, 1 s loading, 1 s relaxation) and exercise volume (integral of the plantar flexion moment over time) for 14 weeks, 4 days per week, 5 sets per session. The exercise volume was similar to the intervention of our earlier study (0.17 Hz frequency; 3 s loading, 3 s relaxation) allowing a direct comparison of the results. Before and after the intervention ankle joint moment has been measured by a dynamometer, tendon–aponeurosis elongation by ultrasound and cross-sectional area of the Achilles tendon by magnet resonance images (MRI). We found a decrease in strain at a given tendon force, an increase in tendon–aponeurosis stiffness and tendon elastic modulus of the Achilles tendon only in the leg exercised at high strain magnitude. The cross-sectional area (CSA) of the Achilles tendon did not show any statistically significant (P>0.05) differences to the pre-exercise values in both legs. The results indicate a superior improvement in tendon properties (stiffness, elastic modulus and CSA) at the low frequency (0.17 Hz) compared to the high strain frequency (0.5 Hz) protocol. These findings provide evidence that the strain magnitude applied to the Achilles tendon should exceed the value, which occurs during habitual activities to trigger adaptational effects and that higher tendon strain duration per contraction leads to superior tendon adaptational responses. Y1 - 2010 U6 - https://doi.org/10.1016/j.jbiomech.2010.08.014 SN - 0021-9290 VL - 43 IS - 16 SP - 3073 EP - 3079 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Aggeloussis, Nickos A1 - Giannakou, Erasmia A1 - Albracht, Kirsten A1 - Arampatzis, Adamantios T1 - Reproducibility of fascicle length and pennation angle of gastrocnemius medialis in human gait in vivo JF - Gait and Posture N2 - The purpose of the current study was to examine the reproducibility of fascicle length and pennation angle of gastrocnemius medialis while human walking. To the best of our knowledge, this is the first study of the reproducibility of fascicle length and pennation angle of gastrocnemius medialis in vivo during human gait. Twelve males performed 10 gait trials on a treadmill, in 2 separate days. B-mode ultrasonography, with the ultrasound probe firmly adjusted in the transverse and frontal planes using a special cast, was used to measure the fascicle length and the pennation angle of the gastrocnemius medialis (GM). A Vicon 624 system with three cameras operating at 120 Hz was also used to record the ankle and knee joint angles. The results showed that measurements of fascicle length and pennation angle showed high reproducibility during the gait cycle, both within the same day and between different days. Moreover, the root mean square differences between the repeated waveforms of both variables were very small, compared with their ranges (fascicle length: RMS = ∼3 mm, range: 38–63 mm; pennation angle: RMS = ∼1.5°, range: 22–32°). However, their reproducibility was lower compared to the joint angles. It was found that representative data have to be derived by a wide number of gait trials (fascicle length ∼six trials, pennation angle more than 10 trials), to assure the reliability of the fascicle length and pennation angle in human gait. Y1 - 2010 U6 - https://doi.org/10.1016/j.gaitpost.2009.08.249 SN - 0966-6362 VL - 31 IS - 1 SP - 73 EP - 77 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Karamanidis, Kiros A1 - Mademli, Lida A1 - Albracht, Kirsten T1 - Plasticity of the human tendon to short and long-term mechanical loading JF - Exercise and Sport Sciences Reviews Y1 - 2009 U6 - https://doi.org/10.1097/JES.0b013e31819c2e1d SN - 1538-3008 VL - 37 IS - 2 SP - 66 EP - 72 ER - TY - JOUR A1 - Miyamoto, Ko-Ichiro A1 - Sato, Takuya A1 - Abe, Minami A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Light-addressable potentiometric sensor as a sensing element in plug-based microfluidic devices JF - Micromachines N2 - A plug-based microfluidic system based on the principle of the light-addressable potentiometric sensor (LAPS) is proposed. The LAPS is a semiconductor-based chemical sensor, which has a free addressability of the measurement point on the sensing surface. By combining a microfluidic device and LAPS, ion sensing can be performed anywhere inside the microfluidic channel. In this study, the sample solution to be measured was introduced into the channel in a form of a plug with a volume in the range of microliters. Taking advantage of the light-addressability, the position of the plug could be monitored and pneumatically controlled. With the developed system, the pH value of a plug with a volume down to 400 nL could be measured. As an example of plug-based operation, two plugs were merged in the channel, and the pH change was detected by differential measurement. KW - light-addressable potentiometric sensor KW - plug-based microfluidic device KW - chemical sensor Y1 - 2016 U6 - https://doi.org/10.3390/mi7070111 SN - 2072-666X N1 - This article belongs to the Special Issue "Micro/Nano Devices for Chemical Analysis" VL - 7 IS - 7 SP - 111 PB - MDPI CY - Basel ER - TY - JOUR A1 - Mahmoudi, Mohammad A1 - Fleischhaker, Robert A1 - Sahrai, Mostafa A1 - Evers, Jörg T1 - Group velocity control in the ultraviolet domain via interacting dark-state resonances JF - Journal of physics B: Atomic, molecular and optical physics Y1 - 2008 U6 - https://doi.org/10.1088/0953-4075/41/2/025504 SN - 0953-4075 SN - 1361-6455 VL - 41 IS - 2 SP - 25504 EP - 25600 ER - TY - JOUR A1 - Fleischhaker, Robert A1 - Krauß, Nico A1 - Schättiger, Farina A1 - Dekorsy, Thomas T1 - Consistent characterization of semiconductor saturable absorber mirrors with singe-pulse and pump-probe spectroscopy JF - Optics Express Y1 - 2013 U6 - https://doi.org/10.1364/OE.21.006764 SN - 1094-4087 VL - 21 IS - 6 SP - 6764 EP - 6776 PB - Optica CY - Washington, DC ER -