TY - JOUR A1 - Ringers, Christa A1 - Bialonski, Stephan A1 - Ege, Mert A1 - Solovev, Anton A1 - Hansen, Jan Niklas A1 - Jeong, Inyoung A1 - Friedrich, Benjamin M. A1 - Jurisch-Yaksi, Nathalie T1 - Novel analytical tools reveal that local synchronization of cilia coincides with tissue-scale metachronal waves in zebrafish multiciliated epithelia JF - eLife N2 - Motile cilia are hair-like cell extensions that beat periodically to generate fluid flow along various epithelial tissues within the body. In dense multiciliated carpets, cilia were shown to exhibit a remarkable coordination of their beat in the form of traveling metachronal waves, a phenomenon which supposedly enhances fluid transport. Yet, how cilia coordinate their regular beat in multiciliated epithelia to move fluids remains insufficiently understood, particularly due to lack of rigorous quantification. We combine experiments, novel analysis tools, and theory to address this knowledge gap. To investigate collective dynamics of cilia, we studied zebrafish multiciliated epithelia in the nose and the brain. We focused mainly on the zebrafish nose, due to its conserved properties with other ciliated tissues and its superior accessibility for non-invasive imaging. We revealed that cilia are synchronized only locally and that the size of local synchronization domains increases with the viscosity of the surrounding medium. Even though synchronization is local only, we observed global patterns of traveling metachronal waves across the zebrafish multiciliated epithelium. Intriguingly, these global wave direction patterns are conserved across individual fish, but different for left and right noses, unveiling a chiral asymmetry of metachronal coordination. To understand the implications of synchronization for fluid pumping, we used a computational model of a regular array of cilia. We found that local metachronal synchronization prevents steric collisions, i.e., cilia colliding with each other, and improves fluid pumping in dense cilia carpets, but hardly affects the direction of fluid flow. In conclusion, we show that local synchronization together with tissue-scale cilia alignment coincide and generate metachronal wave patterns in multiciliated epithelia, which enhance their physiological function of fluid pumping. Y1 - 2023 U6 - https://doi.org/10.7554/eLife.77701 SN - 2050-084X VL - 12 PB - eLife Sciences Publications ER - TY - JOUR A1 - Monakhova, Yulia A1 - Diehl, Bernd W.K. T1 - Novel approach of qNMR workflow by standardization using 2H integral: Application to any intrinsic calibration standard JF - Talanta N2 - Quantitative nuclear magnetic resonance (qNMR) is routinely performed by the internal or external standardization. The manuscript describes a simple alternative to these common workflows by using NMR signal of another active nuclei of calibration compound. For example, for any arbitrary compound quantification by NMR can be based on the use of an indirect concentration referencing that relies on a solvent having both 1H and 2H signals. To perform high-quality quantification, the deuteration level of the utilized deuterated solvent has to be estimated. In this contribution the new method was applied to the determination of deuteration levels in different deuterated solvents (MeOD, ACN, CDCl3, acetone, benzene, DMSO-d6). Isopropanol-d6, which contains a defined number of deuterons and protons, was used for standardization. Validation characteristics (precision, accuracy, robustness) were calculated and the results showed that the method can be used in routine practice. Uncertainty budget was also evaluated. In general, this novel approach, using standardization by 2H integral, benefits from reduced sample preparation steps and uncertainties, and can be applied in different application areas (purity determination, forensics, pharmaceutical analysis, etc.). KW - qNMR KW - Deuterium NMR KW - Deuterated solvents KW - Standardization Y1 - 2021 SN - 0039-9140 U6 - https://doi.org/10.1016/j.talanta.2020.121504 VL - 222 IS - Article number: 121504 PB - Elsevier ER - TY - JOUR A1 - Schöning, Michael Josef T1 - Novel approaches to design siliconbased field-effect sensors JF - Electrochemical Microsystem Technologies, New Trends in Electrochemistry Vol. 2 Y1 - 2002 SP - 384 EP - 408 PB - Taylor & Francis CY - London New York ER - TY - JOUR A1 - Heuermann, Holger A1 - Sadeghfam, Arash T1 - Novel balanced inductor for compact differential systems / Sadeghfam, Arash; Heuermann, Holger JF - Conference proceedings : Tuesday 12th, Wednesday 13th and Thursday 14th October, [RAI International Exhibition and Congress Centre, Amsterdam ; part of European Microwave Week 2004] / EuMA, European Microwave Association Y1 - 2004 SN - 1-580-53992-0 N1 - European Microwave Conference ; (34, 2004, Amsterdam) ; European Microwave Week ; (7, 2004, Amsterdam) SP - 709 EP - 712 PB - Horizon House Publ. CY - London ER - TY - JOUR A1 - Biselli, Manfred A1 - Jelinek, N. A1 - Schmidt, S. A1 - Hilbert, U. T1 - Novel bioreactors for the ex vivo cultivation of hematopoietic cells / Jelinek, N. ; Schmidt, S. ; Hilbert, U. ; Thoma, S. ; Biselli, M. ; Wandrey, C. JF - Engineering in Life Sciences. 2 (2002), H. 1 Y1 - 2002 SN - 1618-0240 SP - 15 EP - 18 ER - TY - JOUR A1 - Wagner, Torsten A1 - Miyamoto, Ko-ichiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Novel combination of digital light processing (DLP) and light-addressable potentiometric sensors (LAPS) for flexible chemical imaging JF - Procedia Engineering N2 - Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach of read out in a light-addressable potentiometric sensor (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device which allows fast and flexible generation of light patterns. With the help of these light patterns the sensor surface of the LAPS device can be read out sequentially in a raster like scheme (scanning LAPS). The DLP approach has several advantages compared to conventional scanning LAPS set-ups, e.g., the spot size, the shape and the intensity of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of measurement. Y1 - 2010 U6 - https://doi.org/10.1016/j.proeng.2010.09.161 SN - 1877-7058 N1 - Eurosensor XXIV Conference, 5-8 September 2010, Linz, Austria VL - 5 SP - 520 EP - 523 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Heuermann, Holger A1 - Hillebrand, Jürgen A1 - Sadeghfam, Arash T1 - Novel Concept of a Digital SigmaDelta-PLL-Phase-Shift-Modulator / Hillebrand, Jürgen ; Sadeghfam, Arash ; Heuermann, Holger Y1 - 2008 SN - 978-3-8007-3086-5 N1 - Microwave Conference (GeMIC), 2008 German SP - 123 EP - 126 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Berndsen, Lars A1 - Lüth, Hans A1 - Schöning, Michael Josef T1 - Novel concepts for flow-rate and flow-direction determination by means of pH-sensitive ISFETs JF - Proceedings of SPIE. 4560 (2001) Y1 - 2001 SP - 19 EP - 27 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Lüth, H. T1 - Novel concepts for silicon-based biosensors JF - Physica Status Solidi (A) (2001) Y1 - 2001 SN - 0031-8965 SP - 65 EP - 77 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Malkoc, Ü. A1 - Thust, M. A1 - Steffen, A. A1 - Kordos, P. A1 - Lüth, H. T1 - Novel electrochemical sensors with structured and porous semiconductor/insulator capacitors JF - Sensors and Actuators B. 65 (2000), H. 1-3 Y1 - 2000 SN - 0925-4005 SP - 288 EP - 290 ER -