TY - JOUR A1 - Šakić, Bogdan A1 - Marinković, Marko A1 - Butenweg, Christoph A1 - Klinkel, Sven ED - Yang, J. T1 - Influence of slab deflection on the out-of-plane capacity of unreinforced masonry partition walls JF - Engineering Structures N2 - Severe damage of non-structural elements is noticed in previous earthquakes, causing high economic losses and posing a life threat for the people. Masonry partition walls are one of the most commonly used non-structural elements. Therefore, their behaviour under earthquake loading in out-of-plane (OOP) direction is investigated by several researches in the past years. However, none of the existing experimental campaigns or analytical approaches consider the influence of prior slab deflection on OOP response of partition walls. Moreover, none of the existing construction techniques for the connection of partition walls with surrounding reinforced concrete (RC) is investigated for the combined slab deflection and OOP loading. However, the inevitable time-dependent behaviour of RC slabs leads to high values of final slab deflections which can further influence boundary conditions of partition walls. Therefore, a comprehensive study on the influence of slab deflection on the OOP capacity of masonry partitions is conducted. In the first step, experimental tests are carried out. Results of experimental tests are further used for the calibration of the numerical model employed for a parametric study. Based on the results, behaviour under combined loading for different construction techniques is explained. The results show that slab deflection leads either to severe damage or to a high reduction of OOP capacity. Existing practical solutions do not account for these effects. In this contribution, recommendations to overcome the problems of combined slab deflection and OOP loading on masonry partition walls are given. Possible interaction of in-plane (IP) loading, with the combined slab deflection and OOP loading on partition walls, is not investigated in this study. KW - Masonry partition walls KW - Earthquake KW - Out-of-plane capacity KW - Slab deflection Y1 - 2023 U6 - http://dx.doi.org/10.1016/j.engstruct.2022.115342 SN - 0141-0296 VL - 276 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Brüssermann, Klaus A1 - Bonnenberg, H. A1 - Söhngen, K. T1 - Ingenieurberatung zur Erfüllung umweltrechtlicher Vorschriften / Bonnenberg, H.; Brüssermann, K.; Söhngen, K. JF - Erfahrungen mit Techniken der städtischen Energieversorgung : Tagung Stuttgart, 25. u. 26. Sept. 1985 / VDI-Gesellschaft Energietechnik Y1 - 1985 SN - 3-18-090573-5 N1 - VDI-Berichte 573 SP - 271 EP - 285 PB - VDI-Verl. CY - Düsseldorf ER - TY - JOUR A1 - Thielemann, Frank A1 - Schaffner, M. T1 - Innovationswiderstände bei der Einführung neuer Tech­nologien. Schaffner, M.; Thielemann, F. JF - Deutscher Drucker. 1992/93 (1993), H. 42 Y1 - 1993 SN - 0012-1096 SP - g15 EP - ff ER - TY - JOUR A1 - Thielemann, Frank A1 - Schaffner, M. T1 - Innovationswiderstände bei der Einführung neuer Tech­nologien. Schaffner, M.; Thielemann, F. JF - Deutscher Drucker. 1992/93 (1993), H. 38 Y1 - 1993 SN - 0012-1096 SP - g12 EP - ff ER - TY - JOUR A1 - Marinkovic, Marko A1 - Butenweg, Christoph T1 - Innovative decoupling system for the seismic protection of masonry infill walls in reinforced concrete frames JF - Engineering Structures Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.engstruct.2019.109435 SN - 0141-0296 VL - 197 IS - Article 109435 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Butenweg, Christoph A1 - Gellert, Christoph T1 - Integrale Gebäudeplanung am Beispiel eines Geschossbaus in Ziegelmauerwerk JF - Mauerwerk : European journal of masonry N2 - Moderne Mauerwerksbauten müssen nach heutigen Anforderungen architektonisch, statisch, energetisch sowie schall- und brandschutztechnisch optimal ausgelegt sein. Aufgrund der Komplexität und engen Verzahnung der einzelnen Anforderungen ist eine integrale Gebäudeplanung zur Erzielung einer qualitativ hochwertigen Bauwerkslösung unbedingt notwendig. Diese erfordert von den Fachplanern vertieftes Spezialwissen in den verschiedenen Bereichen, um insbesondere die Schnittstellen und Bauwerksdetails korrekt zu planen und auszuführen. Der Beitrag stellt die integrale Gebäudeplanung am Beispiel eines Geschossbaus in Ziegelbauweise mit Lösungen für wesentliche Detailpunkte vor Y1 - 2012 U6 - http://dx.doi.org/10.1002/dama.201200550 SN - 1437-1022 (E-Journal); 1432-3427 (Print) VL - Volume 16 IS - 5 SP - 247 EP - 254 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Helsper, Christoph T1 - Integritätsprüfung an LF-Anlagen mit Hilfe von Prüfaerosolen JF - Pharma-Technologie-Journal. 14 (1993), H. 2 Y1 - 1993 SN - 0931-9700 SP - 36 EP - 42 ER - TY - JOUR A1 - Helsper, Christoph A1 - Dreiling, V. A1 - Haller, P. A1 - Kaminski, U. T1 - Intercomparison of Eleven Condensation Nucleus Counters / Dreiling, V. ; Haller, P. ; Helsper, C.; Kaminski, U. ; Plomp, A. ; Raes, F. ; Roth, C. ; Schier, J. ; Schürmann, G. JF - Journal of Aerosol Science. 17 (1986), H. 3 Y1 - 1986 SN - 0021-8502 SP - 565 EP - 570 ER - TY - JOUR A1 - Helsper, Christoph A1 - Horn, Hans-Georg A1 - Schneider, Friedhelm A1 - Wehner, Birgit T1 - Intercomparison of five mobility size spectrometers for measuring atmospheric submicrometer aerosol particles / Helsper, Christoph ; Horn, Hans-Georg ; Schneider, Friedhelm ; Wehner, Birgit ; Wiedensohler, Alfred JF - Gefahrstoffe, Reinhaltung der Luft. Air Quality Control. 68 (2008), H. 11-12 Y1 - 2008 SN - 0949-8036 SP - 475 EP - 481 ER - TY - JOUR A1 - Wettingfeld, Jürgen A1 - Kern, Alexander A1 - Krämer, Heinz-Josef A1 - Thormählen, Reyno T1 - International anerkannte Blitzschutznormen : Ausgewogener und sicherer Schutz N2 - Die Einleitung zur Norm DIN EN 62305-3 beschreibt klar und ein - deutig: Der vorliegende Teil der IEC 62305 behandelt den Schutz von baulichen Anlagen gegen materielle Schäden und den Schutz von Personen gegen Verletzungen durch Berührungs- und Schrittspannungen. Als das wesentlichste und effektivste Mittel zum Schutz von baulichen Anlagen gegen materielle Schäden gilt das Blitz - schutzsystem (LPS). KW - Blitzschutz KW - lightning protection Y1 - 2009 PB - Fachhochschule Aachen CY - Aachen ER -