TY - JOUR A1 - Hagenkamp, Markus A1 - Blanke, Tobias A1 - Döring, Bernd T1 - Thermoelectric building temperature control: a potential assessment JF - International Journal of Energy and Environmental Engineering N2 - This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants. Y1 - 2021 U6 - https://doi.org/10.1007/s40095-021-00424-x N1 - Corresponding author: Markus Hagenkamp VL - 13 SP - 241 EP - 254 PB - Springer CY - Berlin ER - TY - JOUR A1 - Kerpen, Nils B. A1 - Bung, Daniel Bernhard A1 - Valero, Daniel A1 - Schlurmann, Torsten T1 - Energy dissipation within the wave run-up at stepped revetments JF - Journal of Ocean University of China Y1 - 2017 U6 - https://doi.org/10.1007/s11802-017-3355-z SN - 1993-5021 VL - 16 IS - 4 SP - 649 EP - 654 PB - Springer CY - Berlin ER - TY - JOUR A1 - Valero, Daniel A1 - Bung, Daniel Bernhard T1 - Development of the interfacial air layer in the non-aerated region of high-velocity spillway flows: Instabilities growth, entrapped air and influence on the self-aeration onset JF - International Journal of Multiphase Flow N2 - Self-aeration is traditionally explained by the water turbulent boundary layer outer edge intersection with the free surface. This paper presents a discussion on the commonly accepted hypothesis behind the computation of the critical point of self-aeration in spillway flows and a new formulation is proposed based on the existence of a developing air flow over the free surface. Upstream of the inception point of self-aeration, some surface roughening has been often reported in previous studies which consequently implies some entrapped air transport and air–water flows coupling. Such air flow is proven in this study by presenting measured air velocities and computing the air boundary layer thickness for a 1V:2H smooth chute flow. Additionally, the growth rate of free surface waves has been analysed by means of Ultrasonic Sensors measurements, obtaining also the entrapped air concentration. High-speed camera imaging has been used for qualitative study of the flow perturbations. Y1 - 2016 U6 - https://doi.org/10.1016/j.ijmultiphaseflow.2016.04.012 SN - 0301-9322 VL - 84 SP - 66 EP - 74 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bung, Daniel Bernhard T1 - Non-intrusive detection of air–water surface roughness in self-aerated chute flows JF - Journal of hydraulic research Y1 - 2013 SN - 1814-2079 (E-Journal); 0022-1686 (Print) VL - Vol. 51 IS - Iss. 3 SP - 322 EP - 329 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Bung, Daniel Bernhard T1 - Extreme flooding in Western Germany: some thoughts on hazards, return periods and risk JF - Hydrolink N2 - The low-pressure system Bernd involved extreme rainfalls in the Western part of Germany in July 2021, resulting in major floods, severe damages and a tremendous number of casualties. Such extreme events are rare and full flood protection can never be ensured with reasonable financial means. But still, this event must be starting point to reconsider current design concepts. This article aims at sharing some thoughts on potential hazards, the selection of return periods and remaining risk with the focus on Germany. Y1 - 2021 IS - 4 SP - 108 EP - 113 PB - International Association for Hydro-Environment Engineering and Research (IAHR) CY - Madrid ER - TY - JOUR A1 - Bung, Daniel Bernhard T1 - Developing flow in skimming flow regime on embankment stepped spillways JF - Journal of hydraulic research Y1 - 2011 SN - 1814-2079 (E-Journal); 0022-1686 (Print) VL - Vol. 49 IS - Iss. 5 SP - 639 EP - 648 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Wolisz, Henryk A1 - Schütz, Thomas A1 - Blanke, Tobias A1 - Hagenkamp, Markus A1 - Kohrn, Markus A1 - Wesseling, Mark A1 - Müller, Dirk T1 - Cost optimal sizing of smart buildings' energy system components considering changing end-consumer electricity markets JF - Energy Y1 - 2017 U6 - https://doi.org/10.1016/j.energy.2017.06.025 VL - 137 SP - 715 EP - 728 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Blanke, Tobias A1 - Hagenkamp, Markus A1 - Döring, Bernd A1 - Göttsche, Joachim A1 - Reger, Vitali A1 - Kuhnhenne, Markus T1 - Net-exergetic, hydraulic and thermal optimization of coaxial heat exchangers using fixed flow conditions instead of fixed flow rates JF - Geothermal Energy N2 - Previous studies optimized the dimensions of coaxial heat exchangers using constant mass fow rates as a boundary condition. They show a thermal optimal circular ring width of nearly zero. Hydraulically optimal is an inner to outer pipe radius ratio of 0.65 for turbulent and 0.68 for laminar fow types. In contrast, in this study, fow conditions in the circular ring are kept constant (a set of fxed Reynolds numbers) during optimization. This approach ensures fxed fow conditions and prevents inappropriately high or low mass fow rates. The optimization is carried out for three objectives: Maximum energy gain, minimum hydraulic efort and eventually optimum net-exergy balance. The optimization changes the inner pipe radius and mass fow rate but not the Reynolds number of the circular ring. The thermal calculations base on Hellström’s borehole resistance and the hydraulic optimization on individually calculated linear loss of head coefcients. Increasing the inner pipe radius results in decreased hydraulic losses in the inner pipe but increased losses in the circular ring. The net-exergy diference is a key performance indicator and combines thermal and hydraulic calculations. It is the difference between thermal exergy fux and hydraulic efort. The Reynolds number in the circular ring is instead of the mass fow rate constant during all optimizations. The result from a thermal perspective is an optimal width of the circular ring of nearly zero. The hydraulically optimal inner pipe radius is 54% of the outer pipe radius for laminar fow and 60% for turbulent fow scenarios. Net-exergetic optimization shows a predominant infuence of hydraulic losses, especially for small temperature gains. The exact result depends on the earth’s thermal properties and the fow type. Conclusively, coaxial geothermal probes’ design should focus on the hydraulic optimum and take the thermal optimum as a secondary criterion due to the dominating hydraulics. Y1 - 2021 U6 - https://doi.org/10.1186/s40517-021-00201-3 SN - 2195-9706 N1 - Corresponding author: Tobias Blanke VL - 9 IS - Article number: 19 PB - Springer CY - Berlin ER - TY - JOUR A1 - Cheenakula, Dheeraja A1 - Griebel, Kai A1 - Montag, David A1 - Grömping, Markus ED - Huang, Xiaowu T1 - Concept development of a mainstream deammonification and comparison with conventional process in terms of energy, performance and economical construction perspectives JF - Frontiers in Microbiology N2 - Deammonification for nitrogen removal in municipal wastewater in temperate and cold climate zones is currently limited to the side stream of municipal wastewater treatment plants (MWWTP). This study developed a conceptual model of a mainstream deammonification plant, designed for 30,000 P.E., considering possible solutions corresponding to the challenging mainstream conditions in Germany. In addition, the energy-saving potential, nitrogen elimination performance and construction-related costs of mainstream deammonification were compared to a conventional plant model, having a single-stage activated sludge process with upstream denitrification. The results revealed that an additional treatment step by combining chemical precipitation and ultra-fine screening is advantageous prior the mainstream deammonification. Hereby chemical oxygen demand (COD) can be reduced by 80% so that the COD:N ratio can be reduced from 12 to 2.5. Laboratory experiments testing mainstream conditions of temperature (8–20°C), pH (6–9) and COD:N ratio (1–6) showed an achievable volumetric nitrogen removal rate (VNRR) of at least 50 gN/(m3∙d) for various deammonifying sludges from side stream deammonification systems in the state of North Rhine-Westphalia, Germany, where m3 denotes reactor volume. Assuming a retained Norganic content of 0.0035 kgNorg./(P.E.∙d) from the daily loads of N at carbon removal stage and a VNRR of 50 gN/(m3∙d) under mainstream conditions, a resident-specific reactor volume of 0.115 m3/(P.E.) is required for mainstream deammonification. This is in the same order of magnitude as the conventional activated sludge process, i.e., 0.173 m3/(P.E.) for an MWWTP of size class of 4. The conventional plant model yielded a total specific electricity demand of 35 kWh/(P.E.∙a) for the operation of the whole MWWTP and an energy recovery potential of 15.8 kWh/(P.E.∙a) through anaerobic digestion. In contrast, the developed mainstream deammonification model plant would require only a 21.5 kWh/(P.E.∙a) energy demand and result in 24 kWh/(P.E.∙a) energy recovery potential, enabling the mainstream deammonification model plant to be self-sufficient. The retrofitting costs for the implementation of mainstream deammonification in existing conventional MWWTPs are nearly negligible as the existing units like activated sludge reactors, aerators and monitoring technology are reusable. However, the mainstream deammonification must meet the performance requirement of VNRR of about 50 gN/(m3∙d) in this case. KW - anammox KW - energy efficiency KW - mainstream deammonification KW - nitrogen elimination KW - wastewater Y1 - 2023 U6 - https://doi.org/10.3389/fmicb.2023.1155235 SN - 1664-302X VL - 14 IS - 11155235 SP - 1 EP - 15 PB - Frontiers ER - TY - JOUR A1 - Krause, Thomas T1 - Schalung und Gerüste JF - Beispiele für die Baubetriebspraxis / Hoffmann, Manfred ; Kuhlmann, Willy [Hrsg.]. Y1 - 2006 SN - 978-3-8351-0002-2 N1 - Kapitel 7 SP - 122 EP - 131 PB - Teubner CY - Wiesbaden ER -