TY - JOUR A1 - Molinnus, Denise A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Katz, Evgeny A1 - Schöning, Michael Josef T1 - Coupling of Biomolecular Logic Gates with Electronic Transducers: From Single Enzyme Logic Gates to Sense/Act/Treat Chips JF - Electroanalysis N2 - The integration of biomolecular logic principles with electronic transducers allows designing novel digital biosensors with direct electrical output, logically triggered drug-release, and closed-loop sense/act/treat systems. This opens new opportunities for advanced personalized medicine in the context of theranostics. In the present work, we will discuss selected examples of recent developments in the field of interfacing enzyme logic gates with electrodes and semiconductor field-effect devices. Special attention is given to an enzyme OR/Reset logic gate based on a capacitive field-effect electrolyte-insulator-semiconductor sensor modified with a multi-enzyme membrane. Further examples are a digital adrenaline biosensor based on an AND logic gate with binary YES/NO output and an integrated closed-loop sense/act/treat system comprising an amperometric glucose sensor, a hydrogel actuator, and an insulin (drug) sensor. Y1 - 2017 U6 - https://doi.org/10.1002/elan.201700208 SN - 1521-4109 VL - 29 IS - 8 SP - 1840 EP - 1849 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Katz, Evgeny A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Enzyme-based logic gates and circuits - analytical applications and interfacing with electronics JF - Analytical and Bioanalytical Chemistry N2 - The paper is an overview of enzyme-based logic gates and their short circuits, with specific examples of Boolean AND and OR gates, and concatenated logic gates composed of multi-step enzyme-biocatalyzed reactions. Noise formation in the biocatalytic reactions and its decrease by adding a “filter” system, converting convex to sigmoid response function, are discussed. Despite the fact that the enzyme-based logic gates are primarily considered as components of future biomolecular computing systems, their biosensing applications are promising for immediate practical use. Analytical use of the enzyme logic systems in biomedical and forensic applications is discussed and exemplified with the logic analysis of biomarkers of various injuries, e.g., liver injury, and with analysis of biomarkers characteristic of different ethnicity found in blood samples on a crime scene. Interfacing of enzyme logic systems with modified electrodes and semiconductor devices is discussed, giving particular attention to the interfaces functionalized with signal-responsive materials. Future perspectives in the design of the biomolecular logic systems and their applications are discussed in the conclusion. Y1 - 2017 U6 - https://doi.org/10.1007/s00216-016-0079-7 SN - 1618-2650 VL - 409 SP - 81 EP - 94 PB - Springer CY - Berlin ER - TY - JOUR A1 - Laack, Walter van T1 - Neurophysiologisch ist das nicht alles zu erklären : Nahtoderfahrungen aus wissenschaftlicher Sicht JF - Der Allgemeinarzt Y1 - 2017 SN - 0172-7249 VL - 38 IS - 1 SP - 4 EP - 7 PB - Universimed Deutschland GmbH CY - Mainz ER - TY - JOUR A1 - Baringhaus, Ludwig A1 - Gaigall, Daniel T1 - On Hotelling’s T² test in a special paired sample case JF - Communications in Statistics - Theory and Methods N2 - In a special paired sample case, Hotelling’s T² test based on the differences of the paired random vectors is the likelihood ratio test for testing the hypothesis that the paired random vectors have the same mean; with respect to a special group of affine linear transformations it is the uniformly most powerful invariant test for the general alternative of a difference in mean. We present an elementary straightforward proof of this result. The likelihood ratio test for testing the hypothesis that the covariance structure is of the assumed special form is derived and discussed. Applications to real data are given. KW - complete block symmetry KW - Hotelling’s T² test KW - likelihood ratio test KW - uniformly most powerful invariant test Y1 - 2017 U6 - https://doi.org/10.1080/03610926.2017.1408828 SN - 1532-415X VL - 48 IS - 2 SP - 257 EP - 267 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Finger, Felix T1 - Vergleichende Leistungs- und Nutzenbewertung von VTOL- und CTOL-UAVs JF - Luft- und Raumfahrt : informieren, vernetzen, fördern / Hrsg.: Deutsche Gesellschaft für Luft- und Raumfahrt Y1 - 2017 SN - 0173-6264 VL - 38 IS - 1 SP - 44 EP - 47 ER - TY - JOUR A1 - Wilson, Ian D. A1 - Wilson, Claire E. A1 - Scheer, Nico A1 - Dickie, A.P. A1 - Schreiter, K. A1 - Wilson, E. M. A1 - Riley, R. J. A1 - Wehr, R. A1 - Bial, J. T1 - The Pharmacokinetics and Metabolism of Lumiracoxib in Chimeric Humanized and Murinized FRG Mice JF - Biochemical pharmacology Y1 - 2017 U6 - https://doi.org/10.1016/j.bcp.2017.03.015 SN - 1873-2968 VL - Volume 135 SP - 139 EP - 150 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Baringhaus, Ludwig A1 - Gaigall, Daniel T1 - Hotelling’s T² tests in paired and independent survey samples: An efficiency comparison JF - Journal of Multivariate Analysis N2 - Hotelling’s T² tests in paired and independent survey samples are compared using the traditional asymptotic efficiency concepts of Hodges–Lehmann, Bahadur and Pitman, as well as through criteria based on the volumes of corresponding confidence regions. Conditions characterizing the superiority of a procedure are given in terms of population canonical correlation type coefficients. Statistical tests for checking these conditions are developed. Test statistics based on the eigenvalues of a symmetrized sample cross-covariance matrix are suggested, as well as test statistics based on sample canonical correlation type coefficients. Y1 - 2017 U6 - https://doi.org/10.1016/j.jmva.2016.11.004 SN - 0047-259X VL - 2017 IS - 154 SP - 177 EP - 198 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Damm, Marc André A1 - Sauerborn, Markus A1 - Fend, Thomas A1 - Herrmann, Ulf T1 - Optimisation of a urea selective catalytic reduction system with a coated ceramic mixing element JF - Journal of ceramic science and technology Y1 - 2017 SN - 2190-9385 (Print) U6 - https://doi.org/10.4416/JCST2016-00056 SN - 2190-9385 (Online) VL - 8 IS - 1 SP - 19 EP - 24 PB - Göller CY - Baden-Baden ER - TY - JOUR A1 - Schüller, K. A1 - Kowalski, Julia A1 - Raback, P. T1 - Curvilinear melting – A preliminary experimental and numerical study JF - International Journal of Heat and Mass Transfer N2 - When exploring glacier ice it is often necessary to take samples or implement sensors at a certain depth underneath the glacier surface. One way of doing this is by using heated melting probes. In their common form these devices experience a straight one-dimensional downwards motion and can be modeled by standard close-contact melting theory. A recently developed melting probe however, the IceMole, achieves maneuverability by simultaneously applying a surface temperature gradient to induce a change in melting direction and controlling the effective contact-force by means of an ice screw to stabilize its change in attitude. A modeling framework for forced curvilinear melting does not exist so far and will be the content of this paper. At first, we will extend the existing theory for quasi-stationary close-contact melting to curved trajectories. We do this by introducing a rotational mode. This additional unknown in the system implies yet the need for another model closure. Within this new framework we will focus on the effect of a variable contact-force as well as different surface temperature profiles. In order to solve for melting velocity and curvature of the melting path we present both an inverse solution strategy for the analytical model, and a more general finite element framework implemented into the open source software package ELMER. Model results are discussed and compared to experimental data conducted in laboratory tests. Y1 - 2016 U6 - https://doi.org/10.1016/j.ijheatmasstransfer.2015.09.046 SN - 0017-9310 IS - 92 SP - 884 EP - 892 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Arreola, Julio A1 - Mätzkow, Malte A1 - Durán, Marlena Palomar A1 - Greeff, Anton A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Optimization of the immobilization of bacterial spores on glass substrates with organosilanes JF - Physica status solidi (A) : Applications and materials science N2 - Spores can be immobilized on biosensors to function as sensitive recognition elements. However, the immobilization can affect the sensitivity and reproducibility of the sensor signal. In this work, three different immobilization strategies with organosilanes were optimized and characterized to immobilize Bacillus atrophaeus spores on glass substrates. Five different silanization parameters were investigated: nature of the solvent, concentration of the silane, silanization time, curing process, and silanization temperature. The resulting silane layers were resistant to a buffer solution (e.g., Ringer solution) with a polysorbate (e.g., Tween®80) and sonication. KW - silanization KW - organosilanes KW - immobilization KW - endospores KW - biosensors KW - Bacillus atrophaeus Y1 - 2016 U6 - https://doi.org/10.1002/pssa.201532914 SN - 1862-6319 VL - 213 IS - 6 SP - 1463 EP - 1470 PB - Wiley-VCH CY - Weinheim ER -