TY - JOUR A1 - Weber, Tobias A1 - Arent, Jan-Christoph A1 - Münch, Lukas A1 - Duhovic, Miro A1 - Balvers, Johannes M. T1 - A fast method for the generation of boundary conditions for thermal autoclave simulation JF - Composites Part A N2 - Manufacturing process simulation enables the evaluation and improvement of autoclave mold concepts early in the design phase. To achieve a high part quality at low cycle times, the thermal behavior of the autoclave mold can be investigated by means of simulations. Most challenging for such a simulation is the generation of necessary boundary conditions. Heat-up and temperature distribution in an autoclave mold are governed by flow phenomena, tooling material and shape, position within the autoclave, and the chosen autoclave cycle. This paper identifies and summarizes the most important factors influencing mold heat-up and how they can be introduced into a thermal simulation. Thermal measurements are used to quantify the impact of the various parameters. Finally, the gained knowledge is applied to develop a semi-empirical approach for boundary condition estimation that enables a simple and fast thermal simulation of the autoclave curing process with reasonably high accuracy for tooling optimization. Y1 - 2016 U6 - http://dx.doi.org/10.1016/j.compositesa.2016.05.036 SN - 1359-835X VL - 88 SP - 216 EP - 225 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Weber, Tobias A1 - Ruff-Stahl, Hans-Joachim K. T1 - Advances in Composite Manufacturing of Helicopter Parts JF - International Journal of Aviation, Aeronautics, and Aerospace Y1 - 2017 U6 - http://dx.doi.org/10.15394/ijaaa.2017.1153 SN - 2374-6793 VL - 4 IS - 1 ER - TY - CHAP A1 - Otten, D. A1 - Schmidt, M. A1 - Weber, Tobias T1 - Advances in Determination of Material Parameters for Functional Simulations Based on Process Simulations T2 - SAMPE Europe Conference 16 Liege Y1 - 2016 SN - 978-1-5108-3800-0 SP - 570 EP - 577 ER - TY - CHAP A1 - Otten, D. A1 - Schmid, M. A1 - Weber, Tobias T1 - Advances In Sheet Metal-Forming: Reduction Of Tooling Cost By Methodical Optimization T2 - Proceedings of SAMPE Europe Conference, Amiens , France Y1 - 2015 ER - TY - JOUR A1 - Weber, Tobias A1 - Englhard, Markus A1 - Arent, Jan-Christoph A1 - Hausmann, Joachim T1 - An experimental characterization of wrinkling generated during prepreg autoclave manufacturing using caul plates JF - Journal of Composite Materials Y1 - 2019 U6 - http://dx.doi.org/10.1177/0021998319846556 SN - 1530-793X VL - 53 IS - 26-27 SP - 3757 EP - 3773 ER - TY - CHAP A1 - Weber, Tobias A1 - Tellis, Jane J. A1 - Duhovic, Miro T1 - Characterization of tool-part-interaction an interlaminar friction for manufacturing process simulation T2 - ECCM 17, 17th European Conference on Composite Materials, München, DE, Jun 26-30, 2016 Y1 - 2016 SN - 978-3-00-053387-7 SP - 1 EP - 7 ER - TY - JOUR A1 - Richter, Charlotte A1 - Braunstein, Bjoern A1 - Staeudle, Benjamin A1 - Attias, Julia A1 - Suess, Alexander A1 - Weber, Tobias A1 - Mileva, Katya N. A1 - Rittweger, Joern A1 - Green, David A. A1 - Albracht, Kirsten T1 - Contractile behavior of the gastrocnemius medialis muscle during running in simulated hypogravity JF - npj Microgravity N2 - Vigorous exercise countermeasures in microgravity can largely attenuate muscular degeneration, albeit the extent of applied loading is key for the extent of muscle wasting. Running on the International Space Station is usually performed with maximum loads of 70% body weight (0.7 g). However, it has not been investigated how the reduced musculoskeletal loading affects muscle and series elastic element dynamics, and thereby force and power generation. Therefore, this study examined the effects of running on the vertical treadmill facility, a ground-based analog, at simulated 0.7 g on gastrocnemius medialis contractile behavior. The results reveal that fascicle−series elastic element behavior differs between simulated hypogravity and 1 g running. Whilst shorter peak series elastic element lengths at simulated 0.7 g appear to be the result of lower muscular and gravitational forces acting on it, increased fascicle lengths and decreased velocities could not be anticipated, but may inform the development of optimized running training in hypogravity. However, whether the alterations in contractile behavior precipitate musculoskeletal degeneration warrants further study. Y1 - 2021 U6 - http://dx.doi.org/10.1038/s41526-021-00155-7 SN - 2373-8065 N1 - Corresponding author: Charlotte Richter VL - 7 IS - Article number: 32 PB - Springer Nature CY - New York ER - TY - JOUR A1 - Hailer, Benjamin A1 - Weber, Tobias A1 - Neveling, Sebastian A1 - Dera, Samuel A1 - Arent, Jan-Christoph A1 - Middendorf, Peter T1 - Development of a test device to determine the frictional behavior between honeycomb and prepreg layers under realistic manufacturing conditions JF - Journal of Sandwich Structures & Materials N2 - In the friction tests between honeycomb with film adhesive and prepreg, the relative displacement occurs between the film adhesive and the prepreg. The film adhesive does not shift relative to the honeycomb. This is consistent with the core crush behavior where the honeycomb moves together with the film adhesive, as can be seen in Figure 2(a). The pull-through forces of the friction measurements between honeycomb and prepreg at 1 mm deformation are plotted in Figure 17(a). While the friction at 100°C is similar to the friction at 120°C, it decreases significantly at 130°C and exhibits a minimum at 140°C. At 150°C, the friction rises again slightly and then sharply at 160°C. Since the viscosity of the M18/1 prepreg resin drops significantly before it cures [23], the minimum friction at 140°C could result from a minimum viscosity of the mixture of prepreg resin and film adhesive before the bond subsequently cures. Figure 17(b) shows the mean value curve of the friction measurements at 140°C. The error bars, which represent the standard deviation, reveal the good repeatability of the tests. The force curve is approximately horizontal between 1 mm and 2 mm. The friction then slightly rises. As with interlaminar friction measurements, this could be due to the fact that resin is removed by friction and the proportion of boundary lubrication increases. Figure 18 shows the surfaces after the friction measurement. The honeycomb cell walls are clearly visible in the film adhesive. There are areas where the film adhesive is completely removed and the carrier material of the film adhesive becomes visible. In addition, the viscosity of the resin changes as the curing progresses during the friction test. This can also affect the force-displacement curve. Y1 - 2020 U6 - http://dx.doi.org/10.1177/1099636220923986 SN - 1530-7972 IS - Volume 23, Issue 7 SP - 3017 EP - 3043 PB - Sage CY - London ER - TY - CHAP A1 - Englhard, Markus A1 - Weber, Tobias A1 - Arent, Jan-Christoph T1 - Efficiency enhancement for CFRP-Prepregautoclave manufacturing by means of simulation-assisted loading optimization T2 - Proceedings of SAMPE Europe Conference 2021 N2 - A new method for improved autoclave loading within the restrictive framework of helicopter manufacturing is proposed. It is derived from experimental and numerical studies of the curing process and aims at optimizing tooling positions in the autoclave for fast and homogeneous heat-up. The mold positioning is based on two sets of information. The thermal properties of the molds, which can be determined via semi-empirical thermal simulation. The second information is a previously determined distribution of heat transfer coefficients inside the autoclave. Finally, an experimental proof of concept is performed to show a cycle time reduction of up to 31% using the proposed methodology. Y1 - 2021 ER - TY - JOUR A1 - Richter, Charlotte A1 - Braunstein, Björn A1 - Stäudle, Benjamin A1 - Attias, Julia A1 - Süss, Alexander A1 - Weber, Tobias A1 - Mileva, Katya N. A1 - Rittweger, Jörn A1 - Green, David A. A1 - Albracht, Kirsten T1 - Gastrocnemius medialis contractile behavior during running differs between simulated Lunar and Martian gravities JF - Scientific reports N2 - The international partnership of space agencies has agreed to proceed forward to the Moon sustainably. Activities on the Lunar surface (0.16 g) will allow crewmembers to advance the exploration skills needed when expanding human presence to Mars (0.38 g). Whilst data from actual hypogravity activities are limited to the Apollo missions, simulation studies have indicated that ground reaction forces, mechanical work, muscle activation, and joint angles decrease with declining gravity level. However, these alterations in locomotion biomechanics do not necessarily scale to the gravity level, the reduction in gastrocnemius medialis activation even appears to level off around 0.2 g, while muscle activation pattern remains similar. Thus, it is difficult to predict whether gastrocnemius medialis contractile behavior during running on Moon will basically be the same as on Mars. Therefore, this study investigated lower limb joint kinematics and gastrocnemius medialis behavior during running at 1 g, simulated Martian gravity, and simulated Lunar gravity on the vertical treadmill facility. The results indicate that hypogravity-induced alterations in joint kinematics and contractile behavior still persist between simulated running on the Moon and Mars. This contrasts with the concept of a ceiling effect and should be carefully considered when evaluating exercise prescriptions and the transferability of locomotion practiced in Lunar gravity to Martian gravity. KW - Bone quality and biomechanics KW - Environmental impact KW - Skeletal muscle KW - Tendons KW - Ultrasound Y1 - 2021 U6 - http://dx.doi.org/10.1038/s41598-021-00527-9 SN - 2045-2322 N1 - Corresponding author: Charlotte Richter VL - 11 IS - Article number: 22555 PB - Springer Nature CY - London ER -