TY - CHAP A1 - Broenner, Simon A1 - Höfken, Hans-Wilhelm A1 - Schuba, Marko T1 - Streamlining extraction and analysis of android RAM images T2 - Proceedings of the 2nd international conference on information systems security and privacy Y1 - 2016 SN - 978-989-758-167-0 U6 - https://doi.org/10.5220/0005652802550264 SP - 255 EP - 264 ER - TY - JOUR A1 - Kolditz, Melanie A1 - Albin, Thivaharan A1 - Abel, Dirk A1 - Fasse, Alessandro A1 - Brüggemann, Gert-Peter A1 - Albracht, Kirsten T1 - Evaluation of foot position and orientation as manipulated variables to control external knee adduction moments in leg extension training JF - Computer methods and programs in biomedicine N2 - Background and Objective Effective leg extension training at a leg press requires high forces, which need to be controlled to avoid training-induced damage. In order to avoid high external knee adduction moments, which are one reason for unphysiological loadings on knee joint structures, both training movements and the whole reaction force vector need to be observed. In this study, the applicability of lateral and medial changes in foot orientation and position as possible manipulated variables to control external knee adduction moments is investigated. As secondary parameters both the medio-lateral position of the center of pressure and the frontal-plane orientation of the reaction force vector are analyzed. Methods Knee adduction moments are estimated using a dynamic model of the musculoskeletal system together with the measured reaction force vector and the motion of the subject by solving the inverse kinematic and dynamic problem. Six different foot conditions with varying positions and orientations of the foot in a static leg press are evaluated and compared to a neutral foot position. Results Both lateral and medial wedges under the foot and medial and lateral shifts of the foot can influence external knee adduction moments in the presented study with six healthy subjects. Different effects are observed with the varying conditions: the pose of the leg is changed and the direction and center of pressure of the reaction force vector is influenced. Each effect results in a different direction or center of pressure of the reaction force vector. Conclusions The results allow the conclusion that foot position and orientation can be used as manipulated variables in a control loop to actively control knee adduction moments in leg extension training. KW - External knee adduction moments KW - Manipulated variables KW - Inverse dynamic problem KW - Inverse kinematic problem KW - Musculoskeletal model Y1 - 2016 U6 - https://doi.org/10.1016/j.cmpb.2016.09.005 SN - 0169-2607 N1 - Part of special issue: "SI: Personalised Models and System Identification" VL - 171 SP - 81 EP - 86 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Belavy, Daniel L. A1 - Albracht, Kirsten A1 - Bruggemann, Gert-Peter A1 - Vergroesen, Pieter-Paul A. A1 - Dieen, Jaap H. van T1 - Can exercise positively influence the intervertebral disc? JF - Sports Medicine N2 - To better understand what kinds of sports and exercise could be beneficial for the intervertebral disc (IVD), we performed a review to synthesise the literature on IVD adaptation with loading and exercise. The state of the literature did not permit a systematic review; therefore, we performed a narrative review. The majority of the available data come from cell or whole-disc loading models and animal exercise models. However, some studies have examined the impact of specific sports on IVD degeneration in humans and acute exercise on disc size. Based on the data available in the literature, loading types that are likely beneficial to the IVD are dynamic, axial, at slow to moderate movement speeds, and of a magnitude experienced in walking and jogging. Static loading, torsional loading, flexion with compression, rapid loading, high-impact loading and explosive tasks are likely detrimental for the IVD. Reduced physical activity and disuse appear to be detrimental for the IVD. We also consider the impact of genetics and the likelihood of a ‘critical period’ for the effect of exercise in IVD development. The current review summarises the literature to increase awareness amongst exercise, rehabilitation and ergonomic professionals regarding IVD health and provides recommendations on future directions in research. KW - Intradiscal Pressure KW - Annulus Fibrosus KW - Disc Degeneration KW - Nucleus Pulposus KW - Intervertebral Disc Y1 - 2016 U6 - https://doi.org/10.1007/s40279-015-0444-2 SN - 1179-2035 VL - 46 IS - 4 SP - 473 EP - 485 PB - Springer CY - Berlin ER - TY - CHAP A1 - Kessler, Julia A1 - Balc, Nicolae A1 - Gebhardt, Andreas T1 - Basic research on lattice structures focused on the strut shape and welding beads T2 - Physics Procedia Y1 - 2016 U6 - https://doi.org/10.1016/j.phpro.2016.08.086 SN - 1875-3884 N1 - Laser Assisted Net Shape Engineering 9th International Conference on Photonic Technologies Proceedings of the LANE 2016 VL - Vol. 83 SP - 833 EP - 838 ER - TY - JOUR A1 - Miyamoto, Ko-Ichiro A1 - Sato, Takuya A1 - Abe, Minami A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Light-addressable potentiometric sensor as a sensing element in plug-based microfluidic devices JF - Micromachines N2 - A plug-based microfluidic system based on the principle of the light-addressable potentiometric sensor (LAPS) is proposed. The LAPS is a semiconductor-based chemical sensor, which has a free addressability of the measurement point on the sensing surface. By combining a microfluidic device and LAPS, ion sensing can be performed anywhere inside the microfluidic channel. In this study, the sample solution to be measured was introduced into the channel in a form of a plug with a volume in the range of microliters. Taking advantage of the light-addressability, the position of the plug could be monitored and pneumatically controlled. With the developed system, the pH value of a plug with a volume down to 400 nL could be measured. As an example of plug-based operation, two plugs were merged in the channel, and the pH change was detected by differential measurement. KW - light-addressable potentiometric sensor KW - plug-based microfluidic device KW - chemical sensor Y1 - 2016 U6 - https://doi.org/10.3390/mi7070111 SN - 2072-666X N1 - This article belongs to the Special Issue "Micro/Nano Devices for Chemical Analysis" VL - 7 IS - 7 SP - 111 PB - MDPI CY - Basel ER - TY - CHAP A1 - Rieper, Harald A1 - Gebhardt, Andreas A1 - Stucker, Brent T1 - Process parameters for Selective Laser Melting of AgCu7 T2 - DDMC, Fraunhofer Direct Digital Manufacturing Conference, 3 Y1 - 2016 SN - 978-3-8396-1001-5 N1 - DDMC, 2016, Fraunhofer Direct Digital Manufacturing Conference, 3rd, Berlin, DE, 2016-03-16 - 2016-03-17 SP - 171 EP - 176 PB - Fraunhofer-Verlag CY - Stuttgart ER - TY - JOUR A1 - Scheer, Nico A1 - Wilson, Ian D. T1 - A comparison between genetically humanized and chimeric liver humanized mouse models for studies in drug metabolism and toxicity JF - Drug Discovery Today N2 - Mice that have been genetically humanized for proteins involved in drug metabolism and toxicity and mice engrafted with human hepatocytes are emerging and promising in vivo models for an improved prediction of the pharmacokinetic, drug–drug interaction and safety characteristics of compounds in humans. The specific advantages and disadvantages of these models should be carefully considered when using them for studies in drug discovery and development. Here, an overview on the corresponding genetically humanized and chimeric liver humanized mouse models described to date is provided and illustrated with examples of their utility in drug metabolism and toxicity studies. We compare the strength and weaknesses of the two different approaches, give guidance for the selection of the appropriate model for various applications and discuss future trends and perspectives. Y1 - 2016 U6 - https://doi.org/10.1016/j.drudis.2015.09.002 SN - 1359-6446 VL - 21 IS - 2 SP - 250 EP - 263 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Scheer, Nico A1 - Chu, Xiaoyan A1 - Salphati, Laurent A1 - Zamek-Gliszczynski, Maciej J. ED - Nicholls, Glynis T1 - Knockout and humanized animal models to study membrane transporters in drug development T2 - Drug Transporters: Volume 1: Role and Importance in ADME and Drug Development Y1 - 2016 SN - 978-1-78262-379-3 U6 - https://doi.org/10.1039/9781782623793-00298 SP - 298 EP - 332 PB - Royal Society of Chemistry CY - Cambridge ER - TY - CHAP A1 - Wu, Ziyi A1 - Kemper, Hans T1 - The optimal 48 V – battery pack for a specific load profile of a heavy duty vehicle T2 - 8. Internationale Fachtagung Kraftwerk Batterie : 26. – 27. April 2016, Münster, Deutschland Y1 - 2016 ER - TY - CHAP A1 - Neu, Eugen A1 - Janser, Frank A1 - Khatibi, Akbar A. A1 - Orifici, Adrian C. T1 - In-flight vibration-based structural health monitoring of aircraft wings T2 - 30th Congress of the internatonal council of the aeronautical sciences : 25.-30. September 2016, Daejeon, Korea N2 - This work presents a methodology for automated damage-sensitive feature extraction and anomaly detection under multivariate operational variability for in-flight assessment of wings. The method uses a passive excitation approach, i. e. without the need for artificial actuation. The modal system properties (natural frequencies and damping ratios) are used as damage-sensitive features. Special emphasis is placed on the use of Fiber Bragg Grating (FBG) sensing technology and the consideration of Operational and Environmental Variability (OEV). Measurements from a wind tunnel investigation with a composite cantilever equipped with FBG and piezoelectric sensors are used to successfully detect an impact damage. In addition, the feasibility of damage localisation and severity estimation is evaluated based on the coupling found between damageand OEV-induced feature changes. Y1 - 2016 ER -