TY - CHAP A1 - Altherr, Lena A1 - Ederer, Thorsten A1 - Schänzle, Christian A1 - Lorenz, Ulf A1 - Pelz, Peter F. T1 - Algorithmic system design using scaling and affinity laws T2 - Operations Research Proceedings 2015 N2 - Energy-efficient components do not automatically lead to energy-efficient systems. Technical Operations Research (TOR) shifts the focus from the single component to the system as a whole and finds its optimal topology and operating strategy simultaneously. In previous works, we provided a preselected construction kit of suitable components for the algorithm. This approach may give rise to a combinatorial explosion if the preselection cannot be cut down to a reasonable number by human intuition. To reduce the number of discrete decisions, we integrate laws derived from similarity theory into the optimization model. Since the physical characteristics of a production series are similar, it can be described by affinity and scaling laws. Making use of these laws, our construction kit can be modeled more efficiently: Instead of a preselection of components, it now encompasses whole model ranges. This allows us to significantly increase the number of possible set-ups in our model. In this paper, we present how to embed this new formulation into a mixed-integer program and assess the run time via benchmarks. We present our approach on the example of a ventilation system design problem. KW - Optimal Topology KW - Piecewise Linearization KW - Ventilation System KW - Similarity Theory Y1 - 2017 SN - 978-3-319-42901-4 SN - 978-3-319-42902-1 U6 - http://dx.doi.org/10.1007/978-3-319-42902-1 N1 - International Conference of the German, Austrian and Swiss Operations Research Societies (GOR, ÖGOR, SVOR/ASRO), University of Vienna, Austria, September 1-4, 2015 SP - 605 EP - 611 PB - Springer CY - Cham ER - TY - CHAP A1 - Schänzle, Christian A1 - Altherr, Lena A1 - Ederer, Thorsten A1 - Lorenz, Ulf A1 - Pelz, Peter F. T1 - As good as it can be: Ventilation system design by a combined scaling and discrete optimization method T2 - Proceedings of FAN 2015 N2 - The understanding that optimized components do not automatically lead to energy-efficient systems sets the attention from the single component on the entire technical system. At TU Darmstadt, a new field of research named Technical Operations Research (TOR) has its origin. It combines mathematical and technical know-how for the optimal design of technical systems. We illustrate our optimization approach in a case study for the design of a ventilation system with the ambition to minimize the energy consumption for a temporal distribution of diverse load demands. By combining scaling laws with our optimization methods we find the optimal combination of fans and show the advantage of the use of multiple fans. Y1 - 2015 N1 - Proceedings of FAN 2015, Lyon (France), 15 – 17 April 2015 SP - 1 EP - 11 ER - TY - JOUR A1 - Pöttgen, Philipp A1 - Ederer, Thorsten A1 - Altherr, Lena A1 - Pelz, Peter F. T1 - Developing a control strategy for booster stations under uncertain load JF - Applied Mechanics and Materials N2 - Booster stations can fulfill a varying pressure demand with high energy-efficiency, because individual pumps can be deactivated at smaller loads. Although this is a seemingly simple approach, it is not easy to decide precisely when to activate or deactivate pumps. Contemporary activation controls derive the switching points from the current volume flow through the system. However, it is not measured directly for various reasons. Instead, the controller estimates the flow based on other system properties. This causes further uncertainty for the switching decision. In this paper, we present a method to find a robust, yet energy-efficient activation strategy. KW - Technical Operations Research (TOR) KW - Booster Station KW - Pump System KW - Discrete Optimization Y1 - 2015 SN - 1662-7482 U6 - http://dx.doi.org/10.4028/www.scientific.net/AMM.807.241 N1 - Ebenfalls weltweit einsehbar unter: http://wl.fst.tu-darmstadt.de/wl/publications/paper_151123_SFB805_ ICUME_Developing_a_Control_Strategy_for_Booster_Stations_under_Uncertain_Load_poettgen_ederer_pelz_altherr.pdf VL - 807 IS - 807 SP - 241 EP - 246 PB - Trans Tech Publications CY - Bäch ER - TY - JOUR A1 - Pöttgen, Philipp A1 - Ederer, Thorsten A1 - Altherr, Lena A1 - Lorenz, Ulf A1 - Pelz, Peter F. T1 - Examination and optimization of a heating circuit for energy-efficient buildings JF - Energy Technology N2 - The conference center darmstadtium in Darmstadt is a prominent example of energy efficient buildings. Its heating system consists of different source and consumer circuits connected by a Zortström reservoir. Our goal was to reduce the energy costs of the system as much as possible. Therefore, we analyzed its supply circuits. The first step towards optimization is a complete examination of the system: 1) Compilation of an object list for the system, 2) collection of the characteristic curves of the components, and 3) measurement of the load profiles of the heat and volume-flow demand. Instead of modifying the system manually and testing the solution by simulation, the second step was the creation of a global optimization program. The objective was to minimize the total energy costs for one year. We compare two different topologies and show opportunities for significant savings. KW - energy transfer KW - heating system KW - programming KW - system optimization KW - technical operations research Y1 - 2015 SN - 2194-4296 U6 - http://dx.doi.org/10.1002/ente.201500252 VL - 4 IS - 1 SP - 136 EP - 144 PB - WILEY-VCH Verlag CY - Weinheim ER - TY - CHAP A1 - Altherr, Lena A1 - Ederer, Thorsten A1 - Farnetane, Lucas S. A1 - Pöttgen, Philipp A1 - Vergé, Angela A1 - Pelz, Peter F. T1 - Multicriterial design of a hydrostatic transmission system via mixed-integer programming T2 - Operations Research Proceedings 2015 N2 - In times of planned obsolescence the demand for sustainability keeps growing. Ideally, a technical system is highly reliable, without failures and down times due to fast wear of single components. At the same time, maintenance should preferably be limited to pre-defined time intervals. Dispersion of load between multiple components can increase a system’s reliability and thus its availability inbetween maintenance points. However, this also results in higher investment costs and additional efforts due to higher complexity. Given a specific load profile and resulting wear of components, it is often unclear which system structure is the optimal one. Technical Operations Research (TOR) finds an optimal structure balancing availability and effort. We present our approach by designing a hydrostatic transmission system. Y1 - 2017 SN - 978-3-319-42901-4 SN - 978-3-319-42902-1 U6 - http://dx.doi.org/10.1007/978-3-319-42902-1_41 N1 - International Conference of the German, Austrian and Swiss Operations Research Societies (GOR, ÖGOR, SVOR/ASRO), University of Vienna, Austria, September 1-4, 2015 SP - 301 EP - 307 PB - Springer CY - Cham ER - TY - JOUR A1 - Altherr, Lena A1 - Ederer, Thorsten A1 - Pöttgen, Philipp A1 - Lorenz, Ulf A1 - Pelz, Peter F. ED - Pelz, Peter F. ED - Groche, Peter T1 - Multicriterial optimization of technical systems considering multiple load and availability scenarios JF - Applied Mechanics and Materials N2 - Cheap does not imply cost-effective -- this is rule number one of zeitgeisty system design. The initial investment accounts only for a small portion of the lifecycle costs of a technical system. In fluid systems, about ninety percent of the total costs are caused by other factors like power consumption and maintenance. With modern optimization methods, it is already possible to plan an optimal technical system considering multiple objectives. In this paper, we focus on an often neglected contribution to the lifecycle costs: downtime costs due to spontaneous failures. Consequently, availability becomes an issue. KW - sustainability KW - availability KW - energy efficiency KW - mixed-integer linear programming KW - system synthesis Y1 - 2015 SN - 1660-9336 U6 - http://dx.doi.org/10.4028/www.scientific.net/AMM.807.247 VL - 807 SP - 247 EP - 256 ER - TY - CHAP A1 - Altherr, Lena A1 - Leise, Philipp T1 - Resilience as a concept for mastering uncertainty T2 - Mastering Uncertainty in Mechanical Engineering Y1 - 2021 SN - 978-3-030-78353-2 U6 - http://dx.doi.org/10.1007/978-3-030-78354-9 N1 - Unterkapitel 6.3.1 des Kapitels "Strategies for Mastering Uncertainty" SP - 412 EP - 417 PB - Springer CY - Cham ER - TY - CHAP A1 - Altherr, Lena A1 - Leise, Philipp A1 - Pfetsch, Marc E. A1 - Schmitt, Andreas T1 - Optimal design of resilient technical systems on the example of water supply systems T2 - Mastering Uncertainty in Mechanical Engineering Y1 - 2021 SN - 978-3-030-78356-3 N1 - Unterkapitel des Kapitels "Strategies for Mastering Uncertainty" SP - 429 EP - 433 PB - Springer CY - Cham ER - TY - CHAP A1 - Leise, Philipp A1 - Altherr, Lena T1 - Experimental evaluation of resilience metrics in a fluid system T2 - Mastering Uncertainty in Mechanical Engineering Y1 - 2021 SN - 978-3-030-78356-3 N1 - Unterkapitel des Kapitels "Strategies for Mastering Uncertainty" SP - 442 EP - 447 PB - Springer CY - Cham ER - TY - CHAP A1 - Lorenz, Imke-Sophie A1 - Altherr, Lena A1 - Pelz, Peter F. T1 - Resilience enhancement of critical infrastructure – graph-theoretical resilience analysis of the water distribution system in the German city of Darmstadt T2 - 14th WCEAM Proceedings N2 - Water suppliers are faced with the great challenge of achieving high-quality and, at the same time, low-cost water supply. Since climatic and demographic influences will pose further challenges in the future, the resilience enhancement of water distribution systems (WDS), i.e. the enhancement of their capability to withstand and recover from disturbances, has been in particular focus recently. To assess the resilience of WDS, graph-theoretical metrics have been proposed. In this study, a promising approach is first physically derived analytically and then applied to assess the resilience of the WDS for a district in a major German City. The topology based resilience index computed for every consumer node takes into consideration the resistance of the best supply path as well as alternative supply paths. This resistance of a supply path is derived to be the dimensionless pressure loss in the pipes making up the path. The conducted analysis of a present WDS provides insight into the process of actively influencing the resilience of WDS locally and globally by adding pipes. The study shows that especially pipes added close to the reservoirs and main branching points in the WDS result in a high resilience enhancement of the overall WDS. KW - Resilient infrastructure KW - Resilience assessment KW - Resilience metric graph theory KW - Water distribution system KW - Case study Y1 - 2020 SN - 978-3-030-64228-0 SN - 978-3-030-64227-3 U6 - http://dx.doi.org/10.1007/978-3-030-64228-0_13 N1 - 14th WCEAM Proceedings. World Congress on Engineering Asset Management, 28-31 July 2019, Singapore Part of the Lecture Notes in Mechanical Engineering book series (LNME) SP - 137 EP - 149 PB - Springer CY - Cham ER -