TY - CHAP A1 - Fuchs, Britta A1 - Ritz, Thomas A1 - Strauch, Jakob ED - Obaidat, Mohammad S. T1 - Usability of mobile applications : dissemination of usability engineering in small and medium enterprises T2 - Proceedings of the International Conference on Data Communication Networking, e-Business and Optical Communication Systems : Rome, Italy, 24 - 27 July, 2012 ; [integrated in the ICETE (International Conference on e-Business and Telecommunications)] Y1 - 2012 SN - 978-989-8565-23-5 N1 - Nebentitel: DCNET; ICE-B; OPTICS SP - 272 EP - 277 PB - SciTePress CY - [Lissabon] ER - TY - JOUR A1 - Ferrein, Alexander A1 - Fritz, Christian A1 - Lakemeyer, Gerhard T1 - Using Golog for Deliberation and Team Coordination in Robotic Soccer / Ferrein, Alexander ; Fritz, Christian ; Lakemeyer, Gerhard JF - Künstliche Intelligenz : KI. 19 (2005), H. 1 Y1 - 2005 SN - 0933-1875 SP - 24 EP - 30 ER - TY - CHAP A1 - Rausch, Lea A1 - Friesen, John A1 - Altherr, Lena A1 - Pelz, Peter F. ED - Kliewer, Natalia ED - Ehmke, Jan Fabian ED - Borndörfer, Ralf T1 - Using mixed-integer programming for the optimal design of water supply networks for slums T2 - Operations Research Proceedings 2017 N2 - The UN sets the goal to ensure access to water and sanitation for all people by 2030. To address this goal, we present a multidisciplinary approach for designing water supply networks for slums in large cities by applying mathematical optimization. The problem is modeled as a mixed-integer linear problem (MILP) aiming to find a network describing the optimal supply infrastructure. To illustrate the approach, we apply it on a small slum cluster in Dhaka, Bangladesh. Y1 - 2018 SN - 978-3-319-89919-0 (Print) SN - 978-3-319-89920-6 (Online) U6 - https://doi.org/10.1007/978-3-319-89920-6_68 N1 - International Conference of the German Operations Research Society (GOR), Freie Universiät Berlin, Germany, September 6-8, 2017. SP - 509 EP - 516 PB - Springer CY - Cham ER - TY - JOUR A1 - Hüning, Felix T1 - Using Trench PowerMOSFETs in Linear Mode JF - Power Electronics Europe (2012) N2 - If we think about applications for modern Power MOSFETs using trench technology, running them in linear mode may not be top of the priority list. Yet there are multiple uses for Trench Power MOSFETs in linear mode. In fact, even turning the device on and off in switching applications is a form of linear operation. Also, these components can be run in linear mode to protect the device against voltage surges. This article will illustrate the factors that need to be considered for linear operation and show how Trench Power MOSFETs are suited to it. Y1 - 2012 SN - 1748-3530 SP - 27 EP - 29 PB - DFA Media CY - Tonbridge ER - TY - JOUR A1 - Hagemann, Hans-Jürgen A1 - Ihrig, H. T1 - Valence change and phase stability of 3d-doped BaTiO3 annealed in oxygen and hydrogen. Hagemann, H. J.; Ihrig, H. JF - Physical Review B.. 20 (1979), H. 9 Y1 - 1979 SN - 1095-3795 SP - 3871 EP - 3878 ER - TY - CHAP A1 - Müller, Tim M. A1 - Schmitt, Andreas A1 - Leise, Philipp A1 - Meck, Tobias A1 - Altherr, Lena A1 - Pelz, Peter F. A1 - Pfetsch, Marc E. T1 - Validation of an optimized resilient water supply system T2 - Uncertainty in Mechanical Engineering N2 - Component failures within water supply systems can lead to significant performance losses. One way to address these losses is the explicit anticipation of failures within the design process. We consider a water supply system for high-rise buildings, where pump failures are the most likely failure scenarios. We explicitly consider these failures within an early design stage which leads to a more resilient system, i.e., a system which is able to operate under a predefined number of arbitrary pump failures. We use a mathematical optimization approach to compute such a resilient design. This is based on a multi-stage model for topology optimization, which can be described by a system of nonlinear inequalities and integrality constraints. Such a model has to be both computationally tractable and to represent the real-world system accurately. We therefore validate the algorithmic solutions using experiments on a scaled test rig for high-rise buildings. The test rig allows for an arbitrary connection of pumps to reproduce scaled versions of booster station designs for high-rise buildings. We experimentally verify the applicability of the presented optimization model and that the proposed resilience properties are also fulfilled in real systems. KW - Optimization KW - Mixed-integer nonlinear programming KW - Water distribution system KW - Resilience KW - Validation Y1 - 2021 SN - 978-3-030-77255-0 SN - 978-3-030-77256-7 U6 - https://doi.org/10.1007/978-3-030-77256-7_7 N1 - Proceedings of the 4th International Conference on Uncertainty in Mechanical Engineering (ICUME 2021), June 7–8, 2021 SP - 70 EP - 80 PB - Springer CY - Cham ER - TY - JOUR A1 - Yazdanbakhsh, Pedram A1 - Solbach, Klaus A1 - Bitz, Andreas T1 - Variable power combiner for RF mode shimming in 7-T MR imaging JF - IEEE Transaction on Biomedical Engineering N2 - This contribution discusses the utilization of RF power in an MRI system with RF mode shimming which enables the superposition of circularly polarized modes of a transmit RF coil array driven by a Butler matrix. Since the required power for the individual modes can vary widely, mode-shimming can result in a significant underutilization of the total available RF power. A variable power combiner (VPC) is proposed to improve the power utilization: it can be realized as a reconfiguration of the MRI transmit system by the inclusion of one additional matrix network which receives the power from all transmit amplifiers at its input ports and provides any desired (combined) power distribution at its output ports by controlling the phase and amplitude of the amplifiers’ input signals. The power distribution at the output ports of the VPC is then fed into the “mode” ports of the coil array Butler matrix in order to superimpose the spatial modes at the highest achievable power utilization. The VPC configuration is compared to the standard configuration of the transmit chain of our MRI system with 8 transmit channels and 16 coils. In realistic scenarios, improved power utilization was achieved from 17% to 60% and from 14% to 55% for an elliptical phantom and a region of interest in the abdomen, respectively, and an increase of the power utilization of 1 dB for a region of interest in the upper leg. In general, it is found that the VPC allows significant improvement in power utilization when the shimming solution demands only a few modes to be energized, while the technique can yield loss in power utilization in cases with many modes required at high power level. Y1 - 2012 U6 - https://doi.org/10.1109/TBME.2012.2205926 SN - 1558-2531 VL - 59 IS - 9 SP - 2549 EP - 2557 PB - IEEE CY - New York ER - TY - JOUR A1 - Heuermann, Holger A1 - Ibrahim, Irfan A1 - Hillebrand, J. T1 - Vector-Signal-Generator with Two ¿¿-PLL's / Ibrahim, I. ; Hillebrand, J. ; Heuermann, H. JF - European Conference on Wireless Technologies, 2007. ECWT 2007 ; 8 - 10 October 2007 Munich, Germany Y1 - 2007 SN - 978-2-87487-003-3 SP - 1 EP - 4 ER - TY - JOUR A1 - Heuermann, Holger T1 - Verringerung des Phasenrauschens von Oszillatoren durch Dual-Mode-Resonatoren JF - HF-Report. 20 (2006), H. 5-6 Y1 - 2006 SN - 1431-827X SP - 43 EP - 48 ER - TY - JOUR A1 - Theysohn, Jens M. A1 - Kraff, Oliver A1 - Eilers, Kristina A1 - Andrade, Dorian A1 - Gerwig, Marcus A1 - Timmann, Dagmar A1 - Schmitt, Franz A1 - Ladd, Mark E. A1 - Ladd, Susanne C. A1 - Bitz, Andreas T1 - Vestibular effects of a 7 Tesla MRI examination compared to 1.5 T and 0 T in healthy volunteers JF - PLoS one N2 - Ultra-high-field MRI (7 Tesla (T) and above) elicits more temporary side-effects compared to 1.5 T and 3 T, e.g. dizziness or “postural instability” even after exiting the scanner. The current study aims to assess quantitatively vestibular performance before and after exposure to different MRI scenarios at 7 T, 1.5 T and 0 T. Sway path and body axis rotation (Unterberger's stepping test) were quantitatively recorded in a total of 46 volunteers before, 2 minutes after, and 15 minutes after different exposure scenarios: 7 T head MRI (n = 27), 7 T no RF (n = 22), 7 T only B₀ (n = 20), 7 T in & out B₀ (n = 20), 1.5 T no RF (n = 20), 0 T (n = 15). All exposure scenarios lasted 30 minutes except for brief one minute exposure in 7 T in & out B₀. Both measures were documented utilizing a 3D ultrasound system. During sway path evaluation, the experiment was repeated with eyes both open and closed. Sway paths for all long-lasting 7 T scenarios (normal, no RF, only B₀) with eyes closed were significantly prolonged 2 minutes after exiting the scanner, normalizing after 15 minutes. Brief exposure to 7 T B₀ or 30 minutes exposure to 1.5 T or 0 T did not show significant changes. End positions after Unterberger's stepping test were significantly changed counter-clockwise after all 7 T scenarios, including the brief in & out B₀ exposure. Shorter exposure resulted in a smaller alteration angle. In contrast to sway path, reversal of changes in body axis rotation was incomplete after 15 minutes. 1.5 T caused no rotational changes. The results show that exposure to the 7 Tesla static magnetic field causes only a temporary dysfunction or “over-compensation” of the vestibular system not measurable at 1.5 or 0 Tesla. Radiofrequency fields, gradient switching, and orthostatic dysregulation do not seem to play a role. Y1 - 2014 U6 - https://doi.org/10.1371/journal.pone.0092104 SN - 1932-6203 VL - 9 IS - 3 PB - PLOS CY - San Francisco ER -